12 results (0,14010 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

Heatmiser UH4 4 Zone 230V Wiring Centre

Heatmiser UH8 230v 8 Zone Wiring Centre

Heatmiser UH8 RF 230v 8 Zone Wiring Centre

Panasonic Aquarea HT Mono-Bloc air to Water Heat Pump

Panasonic Aquarea HT Mono-Bloc air to Water Heat Pump

Panasonic Aquarea HT Mono-Bloc air to Water Heat Pump G Generation Heating only with R407C refrigerant                                 Panasonic air to water heat pump is an eco-friendly, affordable, and safe way to heat your home when compared to traditional electrical, gas and oil heating systems that are now being phased out of production due to climate change regulations The HT (High Temperature) unit is Ideal for retrofitting to a house with old high-temperature radiators and can provide output water temperatures of 65° even at outdoor temperatures as low as -15° The Monobloc configuration keeps all components of the heat pump within a single outdoor enclosure. Two pipes carry water between the outdoor unit and the interior portions of the overall system. As there are no external refrigerant pipes the units are pre-charged and would provide the simplest installation This system will also benefit with the additional use of a DUE Pre-Plumbed water cylinder and buffer tank T-Cap are suitable for Min outdoor temperature of -28° and can supply 35° hot water/ heating @ -20° Market-leading Seven-year Parts and Labour warranty on Panasonic heat pumps if installed and serviced by an approved Panasonic engineer HT benefit Ideal for replacement of conventional high-temperature boilers 7-year Parts and Labour Warranty* 9kW to 12kW Passive house approved and suitable for NZEB buildings Recommend being used with DUE Pre-plumbed water cylinder Aquarea manager or BMS integration Aquarea Smart Cloud is the most advanced heating control for today and for the future. Aquarea can be connected to the Cloud with CZ-TAW1, enabling both end-user control and remote maintenance by service partners. Panasonic All in One air to water heat pumps should be installed by a qualified installer and preferably an approved Panasonic heat pump engineer To purchase this heat pump, we will require the installers details and current F-Gas number before it is dispatched If you are an installer, please sign up with us to become an approved Panasonic installer and receive free training, Rewards and be able to provide up to a 7-year parts and labour warranty to your customers and possible sales leads and installation work * Market leading Seven-year Parts and Labour warranty on Panasonic heat pumps if installed and serviced by an approved Panasonic engineer

GBP 4703.64
1

Vent Matika EKA standard duct heater

Vent Matika EKA standard duct heater

Vent Matika EKA standard duct heater Description The Vent Matika EKA range of electric duct heaters are Used in ventilation systems as heaters for comfort, or preheaters, to protect the ventilation unit from frost. The Vent Matika EKA standard range have no integrated control BPC Ventilation are the largest independent MVHR specialists and supply lifetime technical support on our top-quality systems, KEY FEATURES – Vent Matika EKA standard heater No integrated control Internal temperature regulator May be used as a Pre Heater or a Post Heater Twin overheating protection Easy to use screw terminals Rubber sealed ductwork connections Can be installed both horizontally and vertically Stainless steel heating element Aluzinc Casing CE, RoSH & Reach certified Control Options No integrated control feature on this unit and we recommend connection to a EKR electric heater control and sensors or 3rd party control panel with fused supply  (electrician installation recommended) Overheating Protection The EKA has two overheat protection thermostats installed in the electrical circular heater The first one with automatic reset, turns off the heating when the temperature reaches 50 °C and turns on when the temperature drops below 50 °C. The second with manual safety reset, turns off the heating when the temperature reaches 100 °C. In this case you need to figure the cause of the overheating of the heater. Eliminate the overheating cause and press the RESET button on the heaters cover. Construction Manufactured of from Aluzinc coated steel which is high temperature proof Mounting Heaters can only be installed inside away from moisture and mounted horizontally with the electrical connection box facing upwards or sideways and vertically (only if the air flow direction upwards). Temperature The maximum temperature of the output is 50 °C. Dimensions Models These models are kept in stock, but other sizes and power outputs are available to order and please contact our team for cost and availability 100mm - 0.6kw Electric Duct Heater - EKA-100-0.6 125mm - 1.2kw Electric Duct Heater - EKA-125-1.2 160mm - 1.2kw Electric Duct Heater - EKA-160-1.2 160mm - 2.4kw Electric Duct Heater - EKA-160-2.4 200mm - 3.0kw Electric Duct Heater - EKA-200-3.0 250mm - 3.0kw Electric Duct Heater - EKA-250-3.0 Optional Accessories EKR 6.1 - electric heater controller for single phase electric heaters up to 6 kw. Controls by supply* or room temperature. Has an internal temperature sensor in casing, an additional TJ-K10K duct mounted supply air temperature sensor is also required for operation in both modes.  BPC Support We don’t sell boxes; we provide a service that few can match Free Lifetime Technical support on purchased items Largest independent MVHR suppliers Lowest cost on full systems guaranteed Inhouse design Team Inhouse certified training Largest range and stock available Worldwide delivery options MVHR Solutions available from Value to Prestige housing

GBP 121.73
1

Vent Matika EKA NIS duct heater

Vent Matika EKA NIS duct heater

Vent Matika EKA NIS duct heater Description The Vent Matika EKA NIS range of electric duct heaters are Used in ventilation systems as heaters for comfort, or preheaters, to protect the ventilation unit from frost The Vent Matika EKA NIS range of electric duct heaters are controlled by an external 0 to 10v DC signal from a compatible MVHR unit or independent controller BPC Ventilation are the largest independent MVHR specialists and supply lifetime technical support on our top-quality systems, Key Features Controlled via a 0 to 10v DC signal Internal temperature regulator May be used as a Pre Heater or a Post Heater Twin overheating protection Easy to use screw terminals Rubber sealed ductwork connections Can be installed both horizontally and vertically Stainless steel heating element Aluzinc Casing CE, RoSH & Reach certified Control Options 0-10v sensor from a compatible MVHR unit or independent controller will allow 0-100% control of the heaters power Overheating Protection Two overheat protection thermostats are installed in the electrical circular heater EKA. The first one with automatic reset, turns off the heating when the temperature reaches 50 °C and turns on when the temperature drops below 50 °C. The second with manual safety reset, turns off the heating when the temperature reaches 100 °C. In this case you need to figure the cause of the overheating of the heater. Eliminate the overheating cause and press the RESET button on the heaters cover. Construction Manufactured of from Aluzinc coated steel which is high temperature proof Mounting Heaters can only be installed inside away from moisture and mounted horizontally with the electrical connection box facing upwards or sideways and vertically (only if the air flow direction upwards). Installation Temperature The maximum temperature of the output is 50 °C. Dimensions Models These models are kept in stock, but other sizes and power outputs are available to order and please contact our team for cost and availability 100mm - 0.6kw Electric Duct Heater - EKA-NIS 100-0.6 125mm - 1.2kw Electric Duct Heater - EKA-NIS-125-1.2 160mm - 1.2kw Electric Duct Heater - EKA-NIS-160-1.2 160mm - 2.4kw Electric Duct Heater - EKA-NIS-160-2.4 200mm - 3.0kw Electric Duct Heater - EKA-NIS-200-3.0 250mm - 3.0kw Electric Duct Heater - EKA-NIS-250-3.0 Optional accessories PTC Airflow sensor– Unit mounted sensor for electronic protection from insufficient airflow. The heater is only allowed to work if the airflow velocity is 1,5m/s or higher PS Differential Pressure Switch – a unit mounted pressure switch that provides mechanical protection against loss or insufficient airflow. The heater if not allowed to heat unless a minimum airflow of 1,5m/s is reached.   (Note -due to required velocity the PTC or PS option may not work on some smaller domestic MVHR or MEV systems with low airflow rates) PTC/PS – Sensor for minimum air velocity detection and diff. pressure switch for air flow detection PTC/K – Sensor for minimum air velocity detection and contactor for overheating protection 2NTC – 2 sensors for the air temperature measuring PTC/2NTC – Sensor for min. air velocity detection and 2 sensors for the air temperature measuring By ordering the PS, an internal contactor for power supply is added to the heater as well.  BPC Support We don’t sell boxes; we provide a service that few can match Free Lifetime Technical support on purchased items Largest independent MVHR suppliers Lowest cost on full systems guaranteed Inhouse design Team Inhouse certified training Largest range and stock available Worldwide delivery options

GBP 195.38
1

Vent Matika EKA NV duct heater

Vent Matika EKA NV duct heater

Vent Matika EKA NV duct heater Description The Vent Matika EKA NV range of electric duct heaters are Used in ventilation systems as heaters for comfort, or preheaters, to protect the ventilation unit from frost. The EKA NV is controlled by a duct temperature sensor and unit mounted set point controller BPC Ventilation are the largest independent MVHR specialists and supply lifetime technical support on our top-quality systems, Key Features Controlled via unit mounted set point controller Internal temperature regulator May be used as a Pre Heater or a Post Heater Twin overheating protection Easy to use screw terminals Rubber sealed ductwork connections Can be installed both horizontally and vertically Stainless steel heating element Aluzinc Casing CE, RoSH & Reach certified Control Options The EKA NV unit uses a duct mounted temperature sensor and is controlled via the set point potentiometer on the top of the heater casing. Overheating Protection Two overheat protection thermostats are installed in the electrical circular heater EKA. The first one with automatic reset, turns off the heating when the temperature reaches 50 °C and turns on when the temperature drops below 50 °C. The second with manual safety reset, turns off the heating when the temperature reaches 100 °C. In this case you need to figure the cause of the overheating of the heater. Eliminate the overheating cause and press the RESET button on the heaters cover. Construction Manufactured of from Aluzinc coated steel which is high temperature proof Mounting Heaters can only be installed inside away from moisture and mounted horizontally with the electrical connection box facing upwards or sideways and vertically (only if the air flow direction upwards). Installation Temperature The maximum temperature of the output is 50 °C. Dimensions Models These models are kept in stock, but other sizes and power outputs are available to order and please contact our team for cost and availability 100mm - 0.6kw Electric Duct Heater - EKA-NV-100-0.6 125mm - 1.2kw Electric Duct Heater - EKA-NV-125-1.2 160mm - 1.2kw Electric Duct Heater - EKA-NV-160-1.2 160mm - 2.4kw Electric Duct Heater - EKA-NV-160-2.4 200mm - 3.0kw Electric Duct Heater - EKA-NV-200-3.0 250mm - 3.0kw Electric Duct Heater - EKA-NV-250-3.0 Optional accessories PTC Airflow sensor– Unit mounted sensor for electronic protection from insufficient airflow. The heater is only allowed to work if the airflow velocity is 1,5m/s or higher PS Differential Pressure Switch – a unit mounted pressure switch that provides mechanical protection against loss or insufficient airflow. The heater if not allowed to heat unless a minimum airflow of 1,5m/s is reached.   (Note -due to required velocity the PTC or PS option may not work on some smaller domestic MVHR or MEV systems with low airflow rates) PTC/PS – Sensor for minimum air velocity detection and diff. pressure switch for air flow detection PTC/K – Sensor for minimum air velocity detection and contactor for overheating protection 2NTC – 2 sensors for the air temperature measuring PTC/2NTC – Sensor for min. air velocity detection and 2 sensors for the air temperature measuring By ordering the PS, an internal contactor for power supply is added to the heater as well.   BPC Support We don’t sell boxes; we provide a service that few can match Free Lifetime Technical support on purchased items

GBP 291.68
1

Vent Axia Kinetic FH Heat Recovery Unit

Vent Axia Kinetic FH Heat Recovery Unit

Vent Axia Sentinel Kinetic FH Heat Recovery Unit Product Part Number Vent Axia Kinetic F Right Handed - 408167 Vent Axia Kinetic F Left Handed - 408169 Description The UK’s top selling MVHR unit for houses with a max floor area of 150m2 due to the combination of being easy to install with high-quality construction, SAP Appendix Q approval and has multiple control and commissioning options BPC Ventilation are the largest independent MVHR specialists and supply this unit with a 5-year parts warranty* and lifetime technical support on our top-quality systems. Key Features – Vent Axia FH Suitable for floor areas up to 185 m2 Delivers an airflow rate of up to 310 m³/hour @ 100 Pa Full 100% automatic summer bypass to supply unheated air in the summer Sap Appendix Q (BRE) approved Internal humidity sensor for automatic speed control Latest low energy EC/DC motors Digital controller on unit and optional wall mounted controller PVC Counterflow heat recovery core High heat recovery efficiency of up to 90%. Vertical or horizontal pipe connections Multiple Control options including three 0 to100% fan speed settings, nighttime quiet mode, Purge, Humidity, BMS, timer delay, 0-10v & 240v boost options 2 x G4 filters (optional M5) Low weight of only 18KG UK manufactured MVHR unit with 5 Year parts warranty through BPC Optional acoustic Top Box High Performance The Sentinel Kinetic Plus benefits from the latest high efficiency, ED/DC backward curved impeller design, ensuring the lowest possible energy consumption, ultra quiet operation and an exceptional performance range to houses with a floor area of up to 185m2 With a high performance of 310 m3/hr at 100Pa while still achieving almost 90% heat recovery. The fully automatic capability of the Kinetic range means that adequate ventilation is always achieved. Integral Humidity Sensor The integral humidity sensor increases speed in proportion to relative humidity levels, saving energy and reducing noise. The sensor also reacts to small but rapid increases in humidity, even if the normal trigger threshold is not reached. This unique feature ensures adequate ventilation, even for the smallest wet room. The nighttime relative humidity setback feature suppresses nuisance tripping as humidity gradually increases with falling temperature. Digital Controller A digital controller is supplied fitted to the unit allowing multiple options on programming and controllability, including 3 x Integral infinitely variable fan speed control on supply and extract there is also an optional LCD wall mounted controller available  Spigot Options Spigots may be re-positioned from vertical to give horizontal connection or a combination of vertical and horizontal connection. Orientation This unit is available in both a right hand (external pipes to the RHS) and left-hand version (external pipes to the LHS) it is also possible to convert the orientation on site by following our instruction manual 100% summer By-pass During hot weather you can activate the summer By-Pass that will only bring the filtered air in at external temperatures allowing you to naturally cool your home BMS The Kinetics’ BMS capability is also ideal for those commercial applications where landlords or property managers want to monitor and optimise building performance and maintenance. The Kinetic BMS can provide status information and its self-diagnostics can report if any fault is found. Filtration The unit comes supplied with G4 filters with an option of upgrading the air supply filter with a G5 filter that have tool free access As many systems are placed within cupboards the unique filter design folds as you remove it to ensure easy access in restricted spaces. Acoustic enclosure For scenarios where noise is a critical issue, an optional Acoustic Enclosure is available to reduce breakout noise and the Acoustic Top Box will reduce in-duct noise at key frequencies. Frost Protection Automatic frost protection effective to -20°C External Control Components Integral BMS input/output interfaces – 0-10V

GBP 1547.52
1

Vent Axia plus B

Vent Axia plus B

Vent Axia plus B Product Part Number Vent Axia Plus B Right Handed Unit - 443028 Vent Axia Plus B Left Handed Unit - 443028L(Special order only) Key Features – Vent Axia Plus B Suitable for floor areas up to 250m2 Delivers an airflow rate of up to 425 m³/hour @ 100 Pa Full 100% automatic summer bypass to supply unheated air in the summer Sap Appendix Q (BRE) approved Internal humidity sensor for automatic speed control Latest low energy EC/DC motors Digital controller on unit and optional wall mounted controller PVC Counterflow heat recovery core High heat recovery efficiency of up to 90%. Vertical or horizontal pipe connections Multiple Control options including three 0 to100% fan speed settings, nighttime quiet mode, Purge, Humidity, BMS, timer delay, 0-10v & 240v boost options 2 x G4 filters (optional M5) Low weight of only 24KG UK manufactured MVHR unit with 5 Year parts warranty through BPC Optional acoustic Top Box High Performance The Sentinel Kinetic Plus benefits from the latest high efficiency, ED/DC backward curved impeller design, ensuring the lowest possible energy consumption, ultra quiet operation and an exceptional performance range to houses with a floor area of up to 250m2 With a high performance of 425 m3/hr at 100Pa while still achieving almost 90% heat recovery. The fully automatic capability of the Kinetic range means that adequate ventilation is always achieved. Integral Humidity Sensor The integral humidity sensor increases speed in proportion to relative humidity levels, saving energy and reducing noise. The sensor also reacts to small but rapid increases in humidity, even if the normal trigger threshold is not reached. This unique feature ensures adequate ventilation, even for the smallest wet room. The nighttime relative humidity setback feature suppresses nuisance tripping as humidity gradually increases with falling temperature. Digital Controller A digital controller is supplied fitted to the unit allowing multiple options on programming and controllability, including 3 x Integral infinitely variable fan speed control on supply and extract there is also an optional LCD wall mounted controller available  Spigot Options Spigots may be re-positioned from vertical to give horizontal connection or a combination of vertical and horizontal connection. Optional 180mm/200mm spigots can simplify connection in commercial installations where larger diameter duct work has been used. Orientation This unit is available in both a right hand (external pipes to the RHS) and left-hand version (external pipes to the LHS) it is also possible to convert the orientation on site by following our instruction manual 100% summer By-pass During hot weather you can activate the summer By-Pass that will only bring the filtered air in at external temperatures allowing you to naturally cool your home BMS The Kinetics’ BMS capability is also ideal for those commercial applications where landlords or property managers want to monitor and optimise building performance and maintenance. The Kinetic BMS can provide status information and its self-diagnostics can report if any fault is found. Filtration The unit comes supplied with G4 filters with an option of upgrading the air supply filter with a G5 filter that have tool free access As many systems are placed within cupboards the unique filter design folds as you remove it to ensure easy access in restricted spaces. Acoustic enclosure For scenarios where noise is a critical issue, an optional Acoustic Enclosure is available to reduce breakout noise and the Acoustic Top Box will reduce in-duct noise at key frequencies. Frost Protection Automatic frost protection effective to -20°C External Control Components Integral BMS input/output interfaces – 0-10V proportional speed adjustment Volt free contacts 24V sensor supply Integral on/off or trickle boost function from remote switch, e.g. PIR occupancy detector Switched Live input with adjustable ‘delay-on’ feature Fan failure or component failure indicated via individual fault code display Running time counter

GBP 1660.80
1

Vent Axia Sentinel Kinetic BH Heat Recovery Unit

Vent Axia Sentinel Kinetic BH Heat Recovery Unit

Vent Axia Sentinel Kinetic BH Heat Recovery Unit Product Part Number Vent Axia Kinetic BH Right Handed Unit - 443319 Vent Axia Kinetic BH Left Handed Unit - 443319L Description The UK’s top selling MVHR unit for houses with a max floor area of 150m2 due to the combination of being easy to install with high-quality construction, SAP Appendix Q approval and has multiple control and commissioning options BPC Ventilation are the largest independent MVHR specialists and supply this unit with a 5-year parts warranty* and lifetime technical support on our top-quality systems. Key Features – Vent Axia BH Suitable for floor areas up to 150m2 Delivers an airflow rate of up to 245 m³/hour @ 100 Pa Full 100% automatic summer bypass to supply unheated air in the summer Sap Appendix Q (BRE) approved Internal humidity sensor for automatic speed control Latest low energy EC/DC motors Digital controller on unit and optional wall mounted controller PVC Counterflow heat recovery core High heat recovery efficiency of up to 90%. Vertical or horizontal pipe connections Multiple Control options including three 0 to100% fan speed settings, nighttime quiet mode, Purge, Humidity, BMS, timer delay, 0-10v & 240v boost options 2 x G4 filters (optional M5) Low weight of only 15KG UK manufactured MVHR unit with 5 Year parts warranty through BPC Optional acoustic Top Box High Performance The Sentinel Kinetic Plus benefits from the latest high efficiency, ED/DC backward curved impeller design, ensuring the lowest possible energy consumption, ultra quiet operation and an exceptional performance range to houses with a floor area of up to 150m2 With a high performance of 245m3/hr at 100Pa while still achieving almost 90% heat recovery. The fully automatic capability of the Kinetic range means that adequate ventilation is always achieved. Integral Humidity Sensor The integral humidity sensor increases speed in proportion to relative humidity levels, saving energy and reducing noise. The sensor also reacts to small but rapid increases in humidity, even if the normal trigger threshold is not reached. This unique feature ensures adequate ventilation, even for the smallest wet room. The nighttime relative humidity setback feature suppresses nuisance tripping as humidity gradually increases with falling temperature. Digital Controller A digital controller is supplied fitted to the unit allowing multiple options on programming and controllability, including 3 x Integral infinitely variable fan speed control on supply and extract there is also an optional LCD wall mounted controller available  Spigot Options Spigots may be re-positioned from vertical to give horizontal connection or a combination of vertical and horizontal connection. Orientation This unit is available in both a right hand (external pipes to the RHS) and left-hand version (external pipes to the LHS) it is also possible to convert the orientation on site by following our instruction manual 100% summer By-pass During hot weather you can activate the summer By-Pass that will only bring the filtered air in at external temperatures allowing you to naturally cool your home BMS The Kinetics’ BMS capability is also ideal for those commercial applications where landlords or property managers want to monitor and optimise building performance and maintenance. The Kinetic BMS can provide status information and its self-diagnostics can report if any fault is found. Filtration The unit comes supplied with G4 filters with an option of upgrading the air supply filter with a G5 filter that have tool free access As many systems are placed within cupboards the unique filter design folds as you remove it to ensure easy access in restricted spaces. Acoustic enclosure For scenarios where noise is a critical issue, an optional Acoustic Enclosure is available to reduce breakout noise and the Acoustic Top Box will reduce in-duct noise at key frequencies. Frost Protection Automatic frost protection effective to -20°C External Control Components Integral BMS input/output interfaces – 0-10V proportional speed adjustment Volt free contacts 24V

GBP 1209.60
1