12.780 results (0,17605 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

Vox Ignis ViLX-TMS3-AB Adaptor Board To Connect The ViLX-ACR To The ViLX-TMS3

Aritech GS960-TR GS960 Tester And Calibration Tool For Optimal Functioning Of The Sensor In The Acoustic Space

The Fireray One Reflective Auto-Aligning Beam Detector 5m-50m

The Fireray One Reflective Auto-Aligning Beam Detector 5m-50m

The Fireray One Reflective Auto-Aligning Beam Detector 5m-50mPlease Note The standard detection range is 0 to 50m to achieve 0 to 120m you will need to buy the Reflective Long Range Kit. The Fireray One is a standalone beam detector that prioritises ease of installation. The new Fireray One is a beam detector that keeps simplicity at the forefront of design.Considering that beam detectors are often only a small part of the overall fire system we recognise that fire professionals need a simple beam detector that is accessible to anyone from experts to generalists system designers to field engineers while ensuring that the beam detector is going to perform perfectly in a variety of environments.For ease of design the Fireray One can be installed in places that could be exposed to sunlight such as skylights and glass atriums thanks to our patented Light Cancellation Technology. An extended detection range of 5m to 120m using the reflective long range kit allows installation of beam detectors into both large and small spaces. Its white minimalistic look fits well into modern architecture.The Fireray One BenefitsOne Minute Auto-Alignment The Fireray Ones one-minute auto-alignment feature not only saves time during installation the quality of alignment is also guaranteed by the automation protocol. Using the Fireray One a high level of protection is always achieved.One standalone product The Fireray One is a standalone reflective beam detector that requires no specialist tools or prior knowledge or training to get it up and working.One personal installation All of the internal and external features of the Fireray One ensure that anyone can align the beam detector perfectly because the experience and expert knowledge of beam detection has been engineered into the productMovement Tracker The Fireray One contains Building Movement Tracking that maintains its own alignment once installed. Its optics are fully enclosed in an IP-rated casing with a flat surface for easy cleaning without affecting alignment. An integrated user-interface at the front of the product allows realignment and programming without having to dismount the detector.

GBP 730.80
1

RGL Electronics GD2600 Glass Door Bracket To Work With The MSL2600 Range Of Shearlocks

Scope PTPRO2LM PageTek Pro 2 Paging Transmitter For The Hard Of Hearing - With Serial

Scope PTPRO2LM PageTek Pro 2 Paging Transmitter For The Hard Of Hearing - With Serial

Please note The image is for illustrative purposes only - thistransmitter does not come with an aerial included. Compatible aerials can bepurchased separately please see related products below.Scope PTPRO2LM PageTek Pro 2 Paging Transmitter For The Hard Of Hearing - With SerialThe PTPRO2LM is a PageTek Pro 2 Paging Transmitter For The Hard Of Hearing - With Serial.Scope PageTek Pro 2 Industrial Strength paging systems designed for use with professional Fire and Security systems installed in commercialindustrial premises. The system is primarily designed to alert the hearing impaired in the event of a fire or other emergency where an audible sounder is the normal means of indication. Main users include factories offices universities schools hospitals hotels and public buildings.The Pagetek Pro System is designed to comply with the recommendations detailed in BS5839-1 2013 for alerting the hearing impaired to the activation of a Fire Alarm System. The system can also be used in conjunction with a security alarm panel to alert guards who might be located remote from the main premises.The interface to the host Fire alarm system comprises of multiple prioritised Fire inputs and a further input to provide for fault indication from the Fire panel. For ease of installation a monitored interface cable is provided with the system which also includes a common fault relay output back to the host Fire alarm panel. This will activate if the PageTek Pro suffers a mains failure transmitter fault antenna mismatch link failure low battery or missing battery condition.Upon activation of any Fire Zone input the PageTek Pro system will enter the fire alert condition prioritising and transmitting the Fire message to all pagers. The transmissions will be repeated until the fire condition is reset. Special format Scope pagers ensure that users are alerted by distinct vibrate patterns and clear text messages.Key FeaturesUHF radio link for maximum licensable protectionUnique coding avoids neighbouring system clashesSelf-monitoring of system healthRugged steel enclosure to IP65Backlit 2 line Text Display continuously reports system statusAdditional Visible Audible status indicatorsPrioritised Fire Alarm Inputs and Fault inputsAutomated test calls alert pagers to loss of radio signalFault notification to the host Control Equipment via monitored linkKey locked System Test facility for routine confidence checkingOver 90 hours backup operation with internally fitted batteryAdd on AnswerTek Pro receiver system for additional monitoring reporting of radio signal IntegrityRS232 serial input for other messagingOptional Ethernet card and additional RS232 inputHigh power transmitter provides 2w ERP RF output for enhanced coverage of large sites

GBP 1731.60
1

Aritech 2010-2-PAK-900 Addressable Fire Panel Accessory LP Protocol - Enables The 900 Series Protocol

Scope PTPRO2L PageTek Pro 2 Paging Transmitter For The Hard Of Hearing - 1.0W RF Output

Scope PTPRO2L PageTek Pro 2 Paging Transmitter For The Hard Of Hearing - 1.0W RF Output

Please note The image is for illustrative purposes only - this transmitter does not come with an aerial included. Compatible aerials can be purchased separately please see related products below.Scope PTPRO2L PageTek Pro 2 Paging Transmitter For The Hard Of Hearing - 1.0W RF OutputThe PTPRO2L is a PageTek Pro 2 Paging Transmitter For The Hard Of Hearing - 1.0W RF Output.Scope PageTek Pro 2 Industrial Strength paging systems designed for use with professional Fire and Security systems installed in commercialindustrial premises. The system is primarily designed to alert the hearing impaired in the event of a fire or other emergency where an audible sounder is the normal means of indication. Main users include factories offices universities schools hospitals hotels and public buildings.The Pagetek Pro System is designed to comply with the recommendations detailed in BS5839-1 2013 for alerting the hearing impaired to the activation of a Fire Alarm System. The system can also be used in conjunction with a security alarm panel to alert guards who might be located remote from the main premises.The interface to the host Fire alarm system comprises of multiple prioritised Fire inputs and a further input to provide for fault indication from the Fire panel. For ease of installation a monitored interface cable is provided with the system which also includes a common fault relay output back to the host Fire alarm panel. This will activate if the PageTek Pro suffers a mains failure transmitter fault antenna mismatch link failure low battery or missing battery condition.Upon activation of any Fire Zone input the PageTek Pro system will enter the fire alert condition prioritising and transmitting the Fire message to all pagers. The transmissions will be repeated until the fire condition is reset. Special format Scope pagers ensure that users are alerted by distinct vibrate patterns and clear text messages.Key FeaturesUHF radio link for maximum licensable protectionUnique coding avoids neighbouring system clashesSelf-monitoring of system healthRugged steel enclosure to IP65Backlit 2 line Text Display continuously reports system statusAdditional Visible Audible status indicatorsPrioritised Fire Alarm Inputs and Fault inputsAutomated test calls alert pagers to loss of radio signalFault notification to the host Control Equipment via monitored linkKey locked System Test facility for routine confidence checkingOver 90 hours backup operation with internally fitted batteryAdd on AnswerTek Pro receiver system for additional monitoring reporting of radio signal IntegrityRS232 serial input for other messagingOptional Ethernet card and additional RS232 inputHigh power transmitter provides 2w ERP RF output for enhanced coverage of large sites

GBP 1638.00
1

Gent ALD-302 Anti Ligature Base for the S-Quad Sensor Requires S4-700 Base

Gent 19104-52 Din Rail Mounting Polarised Relay for Mounting Inside the Interface