2.419 results (0,13398 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

C-Tec XFP510-32 XFP Repeater Panel 32 Zone

C-Tec XFP510-32 XFP Repeater Panel 32 Zone

C-Tec XFP510-32 XFP Repeater Panel 32 ZoneCan be used to repeat the functions of an XFP Main panel at remote parts of a site e.g. all potential fire service entrances. Offers all of the functions and controls of an XFP Main panel access levels 1 2 and 3. Includes an on-board fault relay. Requires its own dedicated Mains power and battery back-up supply.A maximum of eight XFP Repeaters can be connected to one non-networked XFP Main panel. Communication between the XFP Main panel and Repeater requires an AFP711 network driver card fitted as standard in all XFP510-32s available as an optional extra on Main XFP 32 Zone panels. Repeater network wired in 1.5 mm2 two-core screened fire resistant cable. Network length must not exceed 500 metres.Key FeaturesCan be used to repeat the functions of an XFP Main panel at remote parts of a site e.g. all potential fire service entrances.Offers all of the functions and controls of an XFP Main panel access levels 1 2 and 3.Includes an on-board fault relay.Requires its own dedicated Mains power and battery back-up supply.A maximum of eight XFP Repeaters can be connected to one non-networked XFP Main panel.Communication between the XFP Main panel and Repeater requires an AFP711 network driver card fitted as standard in all XFP510-32s available as an optional extra on Main XFP 32 Zone panels.Repeater network is non-redundant and wired in 1.5 mm2 two-core screened fire resistant cable. Network length must not exceed 500 metres.

GBP 433.36
1

Cranford Controls VSO-32-C Cream Platform Sounder 24v 32 Tone EN54-3 Approved

Haes 32 Zone Excel-32 Conventional Control Panel with Networking XL32-32

Haes 32 Zone Excel-32 Conventional Control Panel with Networking XL32-32

Haes 32 Zone Excel-32 Conventional Control Panel with Networking XL32-32Quality reliability ease of use and feature rich are attributes that are consistent across the entire range of Haes fire alarm control panels. The Haes Excel-32 encompasses all of these attributes to provide the fire alarm engineers panel of choice. For the fire alarm engineer the Excel-32 has been designed to minimise labour costs by providing ample room for tasks such as wiring and changing batteries. Activation is via key switch or access code which means you should always be able to work on the panel and the one man walk tests will help reduce the cost of maintaining the fire alarm system.Simplicity is one of the most important aspects when considering the end user of a fire alarm panel. The colour coded buttons and the 3 step silence functionality gives non-technical people the confidence to correctly manage their fire alarm system. All inputs and outputs are fully programmable and there are options to have delays to the outputs. The programming features of the Excel-32 also include 3 different modes to help reduce false alarms. Local fire authorities are demanding this type of functionality to reduce unwanted callouts from alarm receiving centresAs standard all Excel-32 panels provide four monitored sounder circuits Fire Fault VFCO relays Fire Fault switched negative outputs class change and an alert input. Excel-32 panels are approved to European standards EN54-2 4 Fire Detection and Alarm Systems Control Indicating Equipment.Key Features16 - 32 zones3 modes to manage false alarmsApproved to EN54-2 43 year warrantyFour monitored sounder circuitsClass change alert programmable inputsProgrammable relays outputsFire alarm routing outputOne man walk testKey-switch or code entry for activation of controlsFully functional LCD remote display units

GBP 1322.57
1

Advanced QuickZone XL 32 Zone Conventional Control Panel - QZXL-32

Advanced QuickZone XL 32 Zone Conventional Control Panel - QZXL-32

Advanced QuickZone XL 32 Zone Conventional Control Panel - QZXL-32The QuickZone XL 32 is a 16 to 32 Zone Conventional Control Panel with integral power supply and space for appropriate standby batteries. The panel extends the QuickZone range with the same high levels of quality and reliability as well as remaining easy to install maintain and simple to use for the end user. Up to 32 fire zone circuits are provided as well as four monitored sounder circuits complete with 500mA resettable fuses.Fire and fault VFCO relays along with fire fault disablement and reset programmable switched negative outputs. Class change and alert inputs are also available.DIL switches within the panel are used to allow Zone Interface setting and also to allow access to level 3. Dependency modes A B and C are available to help reduce false alarms. The panel is very cost effective and even allows for one man walk tests.Key Features16 24 or 32 Zones3 Modes to manage false alarmsOne man walk testKey-switch or code entry for accessThree year warranty as standardSpace for two 18AHr batteriesIntegral 5 Amp switch mode PSUProgrammable relays outputsApproved to EN54-2 4Network up to 8 control panelsFour monitored sounder circuitsClass change alert programmable inputsFire alarm routing outputTest mode with or without soundersIntegral detector removal monitoringSpacious enclosure for easy installation and cablingThree year warranty as standard

GBP 1875.49
1

C-Tec XFP502H XFP Addressable Two Loop 32 Zone Panel - Hochiki Protocol

C-Tec XFP502H XFP Addressable Two Loop 32 Zone Panel - Hochiki Protocol

C-Tec XFP502H XFP Addressable Two Loop 32 Zone Panel - Hochiki ProtocolC-TECs XFP two loop 32 zone addressable fire alarm panel offers high performance at a very competitive price.LPCB certified to EN54 parts 2 4 it is supplied in durable metal enclosure offers combined keypad or keyswitch entry to Access Levels 2 and 3 and is compatible with Hochikis ESP protocol.Ideal for use in small stand-alone applications or in larger applications due to its ability to sit on network of up to 8 XFP master panels it is one of Europes best-selling addressable fire panels.Packed full of engineering features please refer to the feature list below the XFP502H is also fully compatible with C-TECs Hush Button fire alarm solution.Key FeaturesThird-party certified to EN54-24 by the Loss Prevention Certification Board LPCB.Compatibility with Hochikis ESP protocol.Two independently programmable conventional sounder circuits.Two programmable inputs.A fault output relay and three programmable relay outputs with voltage free changeover contacts.A selection of zone dependencycoincidence functions.A daynight building occupiedunoccupied function.An investigation delay period function.Phased evacuation facility.An alarm counter that records how many times the panel has been in alarm state.Powerful short circuit protected loop drivers capable of supporting up to 40 loop powered 10mA sounders per loop.An integral EN54-4A2 switch mode power supply.Adjustable contamination levels.Earth fault monitoring.Combined keypad keyswitch entry to Access Levels 2 and 3.999 event monitoring.An intuitive Windows based upload-download PC program.Optional flush-mounting bezel and glazed stainless steel enclosure also available.Up to eight XFP main panels any variant can be connected onto a two-wire RS485 non-redundant network. Alternatively up to eight XFP repeaters can be connected to any non-networked main panel.

GBP 796.78
1

C-Tec XFP501H XFP Addressable Single Loop 32 Zone Panel - Hochiki Protocol

C-Tec XFP501H XFP Addressable Single Loop 32 Zone Panel - Hochiki Protocol

C-Tec XFP501H XFP Addressable Single Loop 32 Zone Panel - Hochiki ProtocolC-TECs XFP single loop 32 zoneaddressable fire alarm panel offers high performance at a very competitive price. LPCBcertified to EN54 parts 2 4 it is supplied in durable metal enclosure offers combined keypad or keyswitch entry to Access Levels 2 and 3 and is compatible with Apollos XP95Discovery protocol.Ideal for use in small stand-alone applications orin larger applications dueto its ability to sit on network of up to 8 XFP master panelsit is one of Europes best-selling addressable fire panels. Packed full of engineering features- please refer to the feature list below -the XFP501X is also fully compatible with C-TECs Hush Button fire alarm solution and its new range of EN54 certified addressable sounders and VADs.Key FeaturesThird-party certified to EN54-24 by the Loss Prevention Certification Board LPCB.Compatibility with Apollos XP95Discovery protocol.Two independently programmable conventional sounder circuits.Two programmable inputs.A fault output relay and three programmable relay outputs with voltage free changeover contacts.A selection of zone dependencycoincidence functions.A daynight building occupiedunoccupied function.An investigation delay period function.Phased evacuation facility.An alarm counter that records how many times the panel has been in alarm state.Powerful short circuit protected loop drivers capable of supporting up to 40 loop powered 10mA sounders per loop.An integral EN54-4A2 switch mode power supply.Adjustable contamination levels.Earth fault monitoring.Combined keypad keyswitch entry to Access Levels 2 and 3.999 event monitoring.An intuitive Windows based upload-download PC program.Optional flush-mounting bezel and glazed stainless steel enclosure also available.Up to eight XFP main panels any variant can be connected onto a two-wire RS485 network. Alternatively up to eight XFP repeaters can be connected to any non-networked main panel.

GBP 633.78
1

C-Tec BF3593S Stainless Steel Glazed Enclosure

C-TEC XFP502CA XFP 2 loop 32 Zone Panel C-TEC CAST. Max. 2 x 7Ah batteries

C-TEC XFP502CA XFP 2 loop 32 Zone Panel C-TEC CAST. Max. 2 x 7Ah batteries

C-TEC XFP502CA XFP 2 loop 32 Zone Panel C-TEC CAST. Max. 2 x 7Ah batteriesC-TECs tried and trusted XFP two loop 32 zoneaddressable fire alarm panel - now available with C-TECs own digital fire alarm system protocol CAST and fully certified to EN54 parts 2 4 13.With two powerful 40V 450mA loop drivers allowing the connection of up to 255 CAST devices per loop the installation of a robust feature-packed addressable fire alarm system has never been easier.Always thought of the XFP as an entry-level fire panel Think again. Thanks to CASTs multiple type codes high speed data transmission and two speedy soft addressing options automatic via the panel or manually via a handheld programmerdevice tester it is undoubtedly one of the most powerful two loop fire panels around. This and its ability to sit on a network of up to 8 XFP master panels makes it ideal for use in small to medium sized stand-alone applications and larger more sophisticated installations alike.Protocol FeaturesCAST is the worlds most-advanced distributed intelligence fire alarm system protocol. Conceived designed and realised by C-TEC as part of a five-year multi-million pound project it involved the creation of a powerful proprietary communication protocol C-TEC Addressable System Technology CAST and multiple control panels field devices. Key features include 255 devices per loop. Autonomous decision-making for faster response times. Multiple type codes. 40V loop drive voltage. Two soft addressing options automatic via the panel or manual via a powerful handheld programmer. Powerful multi-level addressing facilitates easy device addition and swapped device identification. Multiple functionality at a single address integrated devices - due 2021. Volumes tones detector modes can be changed at compatible panels. High-speed data transmission and robust data transfer. Provides geographical location of short and open circuit faults a short circuit isolator is included as standard in every CAST field device. Replace device function. Programmable multi-function status LED. Future seamless integration with other CAST life safety systems reducing energy servicing installation and repair costs. ENVISION Enabled - fully compliant with our new ENVISION Cloud-based Fire IoT Remote Access System Test and Site Management software package. Designed and manufactured in the UK.Panel Features Certifiedto EN54-24 by the Loss Prevention Certification Board LPCB and EN54-13 by Kiwa Telefication. Two independently programmable conventional sounder circuits. Two programmable inputs. A fault output relay and three programmable relay outputs with voltage free changeover contacts. A selection of zone dependencycoincidence functions. A daynight building occupiedunoccupied function. An investigation delay period function. Phased evacuation facility. An alarm counter that records how many times the panel has been in alarm state. Powerful short circuit protected loop drivers. An integral EN54-4A2 switch mode. Adjustable contamination levels. Earth fault monitoring. Combined keypad keyswitch entry to Access Levels 2 and 3. 500 event monitoring. An intuitive Windows based upload-download PC program. Up to eight XFP main panels any variant can be connected onto a two-wire RS485 non-redundantnetwork. Alternatively up to eight XFP repeaters can be connected to any non-networked main panel.Cast Commissioning Services available with this Equipment

GBP 701.32
1

C-TEC XFP501CA XFP 1 loop 32 Zone Panel C-TEC CAST. Max. 2 x 7Ah Batteries

C-TEC XFP501CA XFP 1 loop 32 Zone Panel C-TEC CAST. Max. 2 x 7Ah Batteries

C-TEC XFP501CA XFP 1 loop 32 Zone Panel C-TEC CAST. Max. 2 x 7Ah BatteriesC-TECs tried and trusted XFP oneloop 32 zoneaddressable fire alarm panel - now available with C-TECs own digital fire alarm system protocol CAST and fully certified to EN54 parts 2 4 and 13.With a powerful 40V 450mA loop driver allowing the connection of up to 255 CAST devices the installation of a robust feature-packed addressable fire alarm system has never been easier.Always thought of the XFP as an entry-level fire panel Think again. Thanks to CASTs multiple type codes high speed data transmission and two speedy soft addressing options automatic via the panel or manually via a handheld programmerdevice tester it is undoubtedly one of the most powerful one loop fire panels around. This and its ability to sit on a network of up to 8 XFP master panels makes it ideal for use in small to medium sized stand-alone applications and larger more sophisticated installations alike.Protocol FeaturesCAST is the worlds most-advanced distributed intelligence fire alarm system protocol. Conceived designed and realised by C-TEC as part of a five-year multi-million pound project it involved the creation of a powerful proprietary communication protocol C-TEC Addressable System Technology CAST and multiple control panels field devices.Key Features 255 devices per loop. Autonomous decision-making for faster response times. Multiple type codes. 40V loop drive voltage. Two soft addressing options automatic via the panel or manual via a powerful handheld programmer. Powerful multi-level addressing facilitates easy device addition and swapped device identification. Multiple functionality at a single address integrated devices - due 2021. Volumes tones detector modes can be changed at compatible panels. High-speed data transmission and robust data transfer. Provides geographical location of short and open circuit faults a short circuit isolator is included as standard in every CAST field device. Replace device function. Programmable multi-function status LED. Future seamless integration with other CAST life safety systems reducing energy servicing installation and repair costs. ENVISION Enabled - fully compliant with our new ENVISION Cloud-based Fire IoT Remote Access System Test and Site Management software package. Designed and manufactured in the UK.Panel Features Certifiedto EN54-24 by the Loss Prevention Certification Board LPCB and EN54-13 by Kiwa Telefication. Two independently programmable conventional sounder circuits. Two programmable inputs. A fault output relay and three programmable relay outputs with voltage free changeover contacts. A selection of zone dependencycoincidence functions. A daynight building occupiedunoccupied function. An investigation delay period function. Phased evacuation facility. An alarm counter that records how many times the panel has been in alarm state. Powerful short circuit protected loop drivers. An integral EN54-4A2 switch mode. Adjustable contamination levels. Earth fault monitoring. Combined keypad keyswitch entry to Access Levels 2 and 3. 500 event monitoring. An intuitive Windows based upload-download PC program. Up to eight XFP main panels any variant can be connected onto a two-wire RS485 non-redundantnetwork. Alternatively up to eight XFP repeaters can be connected to any non-networked main panel.Cast Commissioning Services available with this Equipment

GBP 557.02
1

C-Tec XFP501X XFP Addressable Single Loop 32 Zone Panel - Apollo XP95 Discovery Protocol

C-Tec XFP501X XFP Addressable Single Loop 32 Zone Panel - Apollo XP95 Discovery Protocol

C-Tec XFP501X XFP Addressable Single Loop 32 Zone Panel - Apollo XP95 Discovery ProtocolC-TECs XFP single loop 32 zoneaddressable fire alarm panel offers high performance at a very competitive price. LPCBcertified to EN54 parts 2 4 it is supplied in durable metal enclosure offers combined keypad or keyswitch entry to Access Levels 2 and 3 and is compatible with Apollos XP95Discovery protocol.Ideal for use in small stand-alone applications orin larger applications dueto its ability to sit on network of up to 8 XFP master panelsit is one of Europes best-selling addressable fire panels. Packed full of engineering features- please refer to the feature list below -the XFP501X is also fully compatible with C-TECs Hush Button fire alarm solution and its new range of EN54 certified addressable sounders and VADs.Key FeaturesThird-party certified to EN54-24 by the Loss Prevention Certification Board LPCB.Compatibility with Apollos XP95Discovery protocol.Two independently programmable conventional sounder circuits.Two programmable inputs.A fault output relay and three programmable relay outputs with voltage free changeover contacts.A selection of zone dependencycoincidence functions.A daynight building occupiedunoccupied function.An investigation delay period function.Phased evacuation facility.An alarm counter that records how many times the panel has been in alarm state.Powerful short circuit protected loop drivers capable of supporting up to 40 loop powered 10mA sounders per loop.An integral EN54-4A2 switch mode power supply.Adjustable contamination levels.Earth fault monitoring.Combined keypad keyswitch entry to Access Levels 2 and 3.999 event monitoring.An intuitive Windows based upload-download PC program.Optional flush-mounting bezel and glazed stainless steel enclosure also available.Up to eight XFP main panels any variant can be connected onto a two-wire RS485 network. Alternatively up to eight XFP repeaters can be connected to any non-networked main panel.

GBP 633.78
1

C-Tec XFP502X XFP Addressable Two Loop 32 Zone Panel - Apollo XP95 Discovery Protocol

C-Tec XFP502X XFP Addressable Two Loop 32 Zone Panel - Apollo XP95 Discovery Protocol

C-Tec XFP502X XFP Addressable Two Loop 32 Zone Panel - Apollo XP95 Discovery ProtocolC-TECs XFP two loop 32 zoneaddressable fire alarm panel offers high performance at a very competitive price. LPCBcertified to EN54 parts 2 4 it is supplied in durable metal enclosure offers combined keypad or keyswitch entry to Access Levels 2 and 3 and is compatible with Apollos XP95Discovery protocol.Ideal for use in small stand-alone applications orin larger applications dueto its ability to sit on network of up to 8 XFP master panelsit is one of Europes best-selling addressable fire panels. Packed full of engineering features- please refer to the feature list below -the XFP501X is also fully compatible with C-TECs Hush Button fire alarm solution and its new range of EN54 certified addressable sounders and VADs.Key FeaturesThird-party certified to EN54-24 by the Loss Prevention Certification Board LPCB.Compatibility with Apollos XP95Discovery protocol.Two independently programmable conventional sounder circuits.Two programmable inputs.A fault output relay and three programmable relay outputs with voltage free changeover contacts.A selection of zone dependencycoincidence functions.A daynight building occupiedunoccupied function.An investigation delay period function.Phased evacuation facility.An alarm counter that records how many times the panel has been in alarm state.Powerful short circuit protected loop drivers capable of supporting up to 40 loop powered 10mA sounders per loop.An integral EN54-4A2 switch mode power supply.Adjustable contamination levels.Earth fault monitoring.Combined keypad keyswitch entry to Access Levels 2 and 3.999 event monitoring.An intuitive Windows based upload-download PC program.Optional flush-mounting bezel and glazed stainless steel enclosure also available.Up to eight XFP main panels any variant can be connected onto a two-wire RS485 network. Alternatively up to eight XFP repeaters can be connected to any non-networked main panel.

GBP 796.78
1

Ampac 4310-0086 FireFinder Plus 32 Zone Alarm Indicator Module

SmartCell SC-32-0210-0001-99 SmartCell SounderWall VAD - White Body - Red Flash