Kidde Airsense EST-XLOGOUT-8F 8 Logical Outputs Card Function Slot Kidde Airsense EST-XLOGOUT-8F 8 Logical Outputs Card Function SlotThe logical output card has eight fully programmable relays which can be used for acknowledging the various states of the EST ENT VES outside to other systems. The channels from 1 to 4 are equipped with NC and channels from 5 to 8 with NO type of relays.Key FeaturesCurrent consumption 10 mA at 48 VStandards EN54-16Operating temperature 0C to 60C GBP 301.28 1
Vesda Xtralis KA-1 Steam Trap Vesda Xtralis KA-1 Steam TrapIf the Compact ASD is operated in environments where condensate can form in the pipe system then a condensate trap is used. To collect the condensate the steam trap is fitted at the lowest point of the pipe system between the air filter and the smoke detection system. Using 45 angles gives optimum wall distance.The steam trap can be operated in a temperature range of 0C to 50C. The sinter filter in the condensate trap has a pore width of 50 m and additionally absorbs coarse dust particles.The condensate trap is used in the following areasAreas with severely oscillating temperatures and high air humidityExternal areasSauna areas GBP 280.10 1
Kidde Airsense EST-XAUDIO-48-RS Function Card 4 IN 8 OUT Audio RS485 Kidde Airsense EST-XAUDIO-48-RS Function Card 4 IN 8 OUT Audio RS485This audio intputoutput card is designed for use with a ESTCU-8LCD function slot. It offers 4-line audio inputs via an RJ45 connector as well as 8 symmetrical outputs via an RJ45 connector for leading out audio signals to the external devices or amplifiers of the EST ENT VES system. The card is also equipped with an RS485 interface with the help of which the EST ENT VES system can be controlled or integrated with devices offered by other producers.Key FeaturesCurrent consumption typically 100 mA at 48 VOperating temperature 0C to 70CStandards EN54-16RS485 interface GBP 673.73 1
Morley KA-1 Steam Trap Morley KA-1 Steam TrapIf the Honeywell Compact ASD is operated in environments where condensate can form in the pipe system then a condensate trap is used. To collect the condensate the steam trap is fitted at the lowest point of the pipe system between the air filter and the smoke detection system. Using 45 angles gives optimum wall distance.The steam trap can be operated in a temperature range of 0C to 50C. The sinter filter in the condensate trap has a pore width of 50 m and additionally absorbs coarse dust particles. The condensate trap is used in the following areas Areas of application l Areas with severely oscillating temperatures and high air humidity l External areas l Sauna areas. GBP 280.10 1
Gent VIG-NC-SMF Fibre Optic Network Card for VIG1-24 and VIG1-72 Vigilon Panels Gent VIG-NC-SMF Fibre Optic Network Card for VIG1-24 and VIG1-72 Vigilon PanelsThe Single Mode Fibre Network Card VIG-NC-SMF allows a fast and reliable network over distances of up to 20km between Vigilon Plus Panels VIGPLUS-24 VIGPLUS-72 Network Nodes VIGPLUS-NODE.The Single Mode Fibre Network card is designed to plug into the backplane of a panel or node in dedicated slots.Key FeaturesFibre optic connects directly to the sockets on the card.Up to 31 panelsnodes on a single network.Up to 200 panelsnodes on a complex networkEN54 V3 Single-Mode FibreConnection is by means of the ST sockets on the SM Fibre Network card.100g weight approximateOperating Temperature 0C to 45CStorage Temperature -10C to 55C GBP 843.34 1
Patol LHDC 1 Meter Commissioning amp Maintenance Test Oven Patol LHDC 1 Meter Commissioning Maintenance Test OvenCommissioning and routine maintenance testing of the Patol Analogue Linear Heat Detection Cable systems can be conducted at site using a calibrated 1 metre test oven.The portable 1 metre test oven concept of testing allows accessible one metre installed lengths of sensor cable to be subjected to temperatures within the alarm range. Thus confirming correct calibration setting selection and alarm levels in accordance with project specification requirements.Where sensor cable is installed within hazardous classified areas or may be inaccessible for oven use an additional one metre length may be series wired with existing cable sensor andor interconnecting cables to allow testing to be carried out local to the electronic interface unit in the safe area. Without adversely affecting system performance levels.Key FeaturesDimensions 1070 x 150 x 130mmWeight 13.55kgOperating Voltage 230115V ac fuse rated 10ATemperature Range 0C to 200CMaterial Rugged Aluminium GBP 5196.24 1
Patol FBS 25 Small Filter Box 25mm PC 50-0500143-01-02P Patol FBS 25 Small Filter Box 25mm PC 50-0500143-01-02PThe filter box small is used as an accessory part for aspirating smoke detectors in areas with low temperature conditions below 0C and high dust levels to prevent false alarms and to increase the lifespan of the smoke sensors substantially.The filter insert is designed for the separation of particles and impurities. Due their particle size smoke particles can pass through this filter unhindered. Reliable and fast fire detection is thus ensured.The air polluted with dust particles is also aspirated by the aspirating smoke detector. To prevent false alarms the aspirated air must be purified of these particles. The filter box small can be used for this purpose as an additional accessory component.Key FeaturesPrevention or substantial reduction of false alarmsLengthening of lifespan of smoke sensorsVery low installation costsSubsequent installation possible at any timeLow operating costsApplicable for all aspirating smoke detectorsQuick clean and inexpensive solutionField of application deep freeze areaPipe Connection Diameter 25mmMaterial PC GBP 184.38 1
Notifier Honeywell ABT-EKB-20M Microphone Keyboard Extension Notifier Honeywell ABT-EKB-20M Microphone Keyboard ExtensionThe ABT-EKB-20M is compatible with all ambient microphones designed with a view to a possibility of its versatile application it is extremely suitable for both decentralized and centralized systems. The architecture of this system is based on fibre optic Ethernet connections between control units and other elements of the system which allows for its application in structures most extensive in terms of area and functionality such as air terminals oil fields and refineries commercial centers and office complexes. The system fully complies with a European mandatory standard EN54-16.DetailsPower supply RJ45 from DFMS or DMSDegree of protection IP 31Number of keys 20Number of LED 20x RGB 20x greenLED colour RGB red green blue separate LED greenOperating temperature 0C to 60CStorage temperature -20C to 70COperating humidity 15 to 80Storage humidity 5 to 95Weight 14 kgDimensions of the space for the description of the buttons 15x25 mm GBP 897.54 1
Zeta CO200 Standalone Carbon Monoxide Detector Zeta CO200 Standalone Carbon Monoxide DetectorThe CO200 is the new standalone CO detector from Zeta Alarm Systems. It has been designed with the same dimensions as a standard 2 gang fitting so can be installed either surface mounted with its own backbox or with a standard recessed box for semi-flush mounting.It can be powered either from 230V AC mains or from a DC supply 9-28V DC.It has a built-in bar graph display to show the current CO level reading and has a 2-stage relay output which operates at first alarm level 100ppm second alarm level 200ppm.There is also a 5-volt alarm output capable of supplying 200mA.It has power fault alarm indications as well as a control button for mute press and reset Press hold for 5 seconds.Key FeaturesSupply Voltage 230V 5060Hz AC or 9 -28V DCQuiescent Current 20 mAStart-up Current 40 mAAlarm Current 300mA excluding Alarm outputBuzzer Output 85dB 3mOperating Temperature 0C to 50CMax Humidity 95 RH NCResponse Time 30 SECONDSSensitivity 50 ppm within 90 minutes100 ppm within 30 minutes 300 ppm within 3 minutes GBP 96.22 1
Kidde Airsense Air Heat Box 9-30422 Kidde Airsense Air Heat Box 9-30422The Stratos range of High Sensitivity Aspirating Smoke Detectors are suitable for installation within an area only if the ambient temperature is expected to be above 0C the minimum operating temperature of a Stratos detector is typically -10C check the specification of the particular detector in question. Where the air temperature in the protected area is consistently below this temperature it is imperative that the detector is mounted outside the protected area in an environment where the temperature meets that specified for the detector.However the sampled air from the protected area must be conditioned before it is passed into the detector. The Air Heater Box is designed to raise the temperature of the air drawn from a very cold environment by passing it across a heating element before it passes into the detector. In this manner the problem of condensation on sampling pipework external to the protected area is minimised. Warming the air sample will also ensure the components of the detector operate within the specified temperature tolerances and it reduces the possibility of surface condensation. GBP 1192.28 1
Zeta SP-REP Simplicity Plus Addressable Full Function Repeater Zeta SP-REP Simplicity Plus Addressable Full Function RepeaterThe Simplicity Plus is the ideal introduction to the world of addressable fire alarm panels.As its name suggests it has been designed with ease of use in mind using pre-programmed values for its programming options. The installer simply needs to configure the loop and enter text labels via the built in keypad optional.The Simplicity Plus has user definable zones option for zonal or common alarm operation options for IO operation alarm verification and user selectable languages.The SP-REP can be connected to all Simplicity Plus panels.Key FeaturesCertified to EN54 parts 2 4User definable zonesOption for zonal or common alarm operationOptions for IO operationAlarm verification help prevent false alarmsUser selectable languagesSet of changeover relay contacts for fault conditionSet of changeover relay contacts for fire condition2048 event log fire faultZone or device disablementOne man test modePlug play no need for any special tools or laptop for commissioningFully integrated keypadAll associated devices are loop poweredFull Fire Information and silence relaySupply Voltage 24V DCSystem Voltage 19 to 30V DCOperating Temp -0C to 50CEnclosure Size 375W x 335H x 75D GBP 515.45 1
Aico RadioLINK Alarm Controller Ei450 Aico RadioLINK Alarm Controller Ei450The Ei450 is used to control all the alarms in a system from one place. We highly recommend fitting a control switch if you have smoke heatand carbon monoxide alarms on the same system as its essential that you can tell which alarm has sounded. From then you can identifywhich danger is present and the action you should take.The Ei450 contains LEDs which clearly display which danger has activated the alarm helping to you take the appropriate action as quickly as possible.Control Switchs increases the flexibility and user friendliness of the alarms by allowing the user to remotely Test Locate and Silencealarms in the systemTestThe alarm systemLocate The alarm that has been activatedSilence Any nuisance alarmsThe Ei450 is powered by a tamper proof sealed in lithium cell giving a completely wire free installation with a 10 year life and connects wirelessly usingRadioLINK interconnection technology so once in place you will need toHouse Codethe switch into the alarm system.Technical SpecificationSupply Voltage 3V Lithium Battery Powered for life.Battery Life 10 years normal operating conditions.Communication 868.499Mhz RadioLINK protocol.Fixing Wall mounting fixtures supplied.Operating Temperature 0C to 40C.Humidity Range 15 to 95 relative humidity.Button functionsTest Test alarms.Locate Identify triggered alarms.Silence Silence alarms.IndicatorsFire Illuminates when fire detected.CO Illuminates when CO detected.EOL illuminates to indicate End of Life.Memory Identifies previously triggered alarms.Diagnostics Walk round test Extended two minute test.Plastic Material UL94HB.Dimensions Product 90mm x 90mm x 30mm.Dimensions Boxed 153mm x 153mm x 40mm.Weight 110g product only 185g boxed.Guarantee 5 years.Approvals CE certified RF EN 300 220-2 EMC EN 301 489-1 EN 301 489-3 EMC. GBP 85.26 1
Zeta SP-126M Simplicity Plus 126 Addressable Fire Alarm Panel - 1 Loop 126 Devices Zeta SP-126M Simplicity Plus 126 Analogue Addressable Fire Alarm Panel - 1 Loop 126 DevicesMetal EnclosureThe Simplicity Plus is the ideal introduction to the world of addressable fire alarm panels.As its name suggests it has been designed with ease of use in mind using pre-programmed values for its programming options. The installer simply needs to configure the loop and enter text labels via the built-in keypad optional.The Simplicity Plus has user definable zones option for zonal or common alarm operation options for IO operation alarm verification and user selectable languages.It can be connected to an RS232 desktop printer for real time event log printing Epson LQ300 recommended and it can also drive a serial repeater model SPREP Part No. 37-179.Alarm VerificationTo help prevent false alarm causing a full evacuation any smoke detector can be set to alarm verification mode with a time delay of between 30 seconds and 4 minutes. Should any of these detectors go into alarm then only the detectors LEDs and soundflasher base if connected will activate. Should the alarm not be cleared with this time delay then a common alarm will occur.Zonal AddressingAll devices are assigned to a specific zone based on their address. This removes a programming step and helps to streamline the commissioning process.Key Features1 Loop 126 DevicesCertified to EN54 parts 2 4User definable zonesOption for zonal or common alarm operationOptions for IO operationAlarm verification help prevent false alarmsUser selectable languagesSet of changeover relay contacts for fault conditionSet of changeover relay contacts for fire condition2048 event log fire faultZone or device disablementOne-man test modePlug play no need for any special tools or laptop for commissioningFully integrated keypadAll associated devices are loop poweredSupply Voltage 230V AC - 10System Voltage 24V DC NominalOperating Temperature -0C to 50CEnclosure Size 375mm x 335mm x 125mm GBP 725.08 1
STI STI-1229HTR240 Weather Strobe Dome Stopper Heated - 240V STI STI-1229HTR240 Weather Strobe Dome Stopper Heated - 240VNEMA 4X heated environmental enclosures for signalling appliance unit UL cUL listed. The Environmental Enclosures for Strobes are an excellent way to protect your signalling device located where temperature or environmental conditions exceed the suggested operation range. This protective cover with heater assembly for strobe appliances is ULcULULC Listed to NEMA 4X standards. Thermostatically controlled heaters and a continuous duty fan maintain a uniform temperature in the cover when located in a cold environment. Applications include but are not limited to refrigerators freezers meat packaging plants arctic environments ocean rigs etc. ULULC Listed down to -57C -70F applicable for indoor and outdoor.PLEASE NOTEThe enclosure is used to protect UL Listed 1638 and 1971 visual notification appliances at temperatures down to -57C -70F. It is the installers responsibility to comply with NFPA 72 NEC and other applicable fire and electrical codes. Conduit or raceway paths need to be sealed as near to the enclosure as possible. Installer should have maintained supervision over the low temperature thermostat. The low temperate monitoring thermostat makes the circuit at 0C 32F and clears the circuit at 10C 50F. This listing requires that the fire alarm supervisory control module be only of the latching type. The heater assembly and gasket have a life of 5 years. After such date a replacement heater assembly can be purchased STI-HK2A. There is a label on the heater assembly to record the installation date. In hazardous areas all sources of power must be shutdown before accessing cover per NEC.Details Protective cover for strobe only 240 VAC heated enclosure Type 4X Enclosed back box 3 year guarantee 1 yr on electronics Please note Due to the curvature of this model the depth stated will vary 184 mm H x 184 mm W x 73 mm D GBP 957.26 1
Aico RadioLINK Panel Interface Ei413 Aico RadioLINK Panel Interface Ei413The Ei413 is a RadioLINK Panel Interface Module that provides an interface between RadioLINK alarms and accessories and fire alarmsecurity alarm panels. The module will decode aFire Carbon Monoxide and fault signals from RadioLINK devices and activate the Panel accordingly and will also work the other way activating the domestic alarms if it receives a signal from the Panel.The module is powered either directly from the Panel Systemor from an external source.Operation of the Ei413 RadioLINK Panel Interference ModuleOn receiving a Volt-free switched hardwired signal from the panel the module will transmit a RadioLINK alarm signal to activate the alarms in the systemIf a fire alarm has activated the module will recognise the signal as a fire and switch the relevant contacts to activate the panelIf a Carbon Monoxidealarm has activated the module will recognise the signal as a Carbon Monoxideleak and switch the relevant contacts to activate the panelTechnical SpecificationEliminate the need for any cabling between the Ei413 and the smokeheatCO alarms used in the system.The Ei413 is conformant to EN300220-1 RF Performance in accordance with EN300220-2 and EN301489-1 EMC referencing EN301489-3.The unit is powered from the alarm panel and requires 11 to 30VDC. Unit current rating 15mA Standby 60mA Alarm Max.The unit has three sets Normally Open Normally Closed and Common of built-in wiring contacts for connection to the panel rated at 30V 1 Amp. On the contacts closing the unit will dependent on which set of contacts are connected indicate a fire CO leak or fault to the panel. The unit also has a Normally Open volt-free set of contacts to link from the panel to it so if the panel is activated the unit will transmit a RadioLINK signal to the alarms in the system to activate them they will sound.Radio frequency 868MHz band in accordance with RTTE Directive 19995EC this band has been designed for use with security products and only allows a 1 duty cycle so continuous transmission and interference from external sources is extremely remote and would be illegal.Up to 12 RadioLINK units can be used in one system. Range may be a limiting factor.RF Range The type of building will be the major limiting factor e.g. the number and type of wallsceilings that the radio signal has to pass through. As a guide 30m should be the maximum distance between any of the RadioLINK units in the system.Units are in factory code when received they will communicate with each other. They must be House Coded to eliminate the risk of adjacent properties communicating with each other. After House Coding they will only communicate with other RadioLINK units coded at the same time.House Code Operate the House Code Switch on all RadioLINK units in the system see the instructions supplied with the other RadioLINK units being used. The LED indicator on the front cover of the Ei413 will flash blue slowly this indicates that it is transmitting its unique serial number to all other RadioLINK units in House Code. After a short time the unit will flash to indicate the number of units in the system 2 flashes 2 units 3 flashes 3 units etc.. The Ei413 will return to normal standby mode automatically after 15 minutes. Pressing the House Code Switch again will return it to normal standby immediately.Designed for surface mounting or can be fitted into certain alarm panels provided the casing is not a metallic construction which may restrict RF signals.Dimensions 88mm x 88mm x 28mm.Weight 150g.Ambient Temperature Range 0C to 40C.5 year guarantee.Manufactured in Ireland. GBP 76.93 1