10 results (0,13198 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

Morley ECO1000RTUA Remote LASER Tester for Vision Detectors

Carrier R5815NT-ART ShatterPro 3 Sensor With quotPattern Recognition Technologyquot Round Non UL Approved

Carrier R5815NT ShatterPro 3 Sensor With quotPattern Recognition Technologyquot Round UL Approved

Aritech GS903N ShatterPro 2 Acoustic Glassbreak Sensor Surface Mount - Range Up To 7.5m Radius

Aritech GS903N ShatterPro 2 Acoustic Glassbreak Sensor Surface Mount - Range Up To 7.5m Radius

Aritech GS903N ShatterPro 2 Acoustic Glassbreak Sensor Surface Mount - Range Up To 7.5m RadiusThe GS903N acoustic glassbreak sensor combines high false alarmimmunity and excellent detection by recognizing the exact frequencypattern generated by glass breaking. Instead of listening for a loudsound at one or two characteristic frequencies the GS903N listens at30 points across the glassbreak frequency spectrum. This not onlyenables it to discriminate common false alarm sources but alsoensures detection of even the quietest of breaks so it can be used withblinds or light curtains. The GS903N is recommended for perimeterloops and is designed to function in occupied areas. In 24-hour loopapplications where the detector is armed all day and all night thefalse alarm technology will be pushed to its limit. Some sounds canduplicate the points on the glassbreak pattern that the GS903 detects.Install the GS903N on a perimeter loop which is armed whenever thedoor and window contacts are armed. The GS903N false alarmimmunity is best in rooms with only moderate noise. For 24-houroccupied area protection use our Shock Detectors. The GS903N maynot consistently detect cracks in glass or bullets which break throughthe glass. Glassbreak detectors should always be backed up byinterior protection.Easy to install and testAvailable in both surface and flush mount versions GS913Ninstallation is quick and easy. There are no sensitivity adjustments toworry about and a new test feature means only one trip up the ladder.Simply activate the tester next to the GS903N and the unit goes intotest mode.A unique test assures end-users that the unit is powered and ready todetect. The sensor will blink twice but will not trip when a loud hardclap is made close to the unit.Pattern Recognition TechnologyThe GS903N detects in a full 360 coverage pattern with a 7.5 mrange from detector to glass. By listening at more than 30 frequencypoints the GS903N can tell the difference between common falsealarm sources and the noise of breaking glass.Key FeaturesNo sensitivity adjustment requiredDetects through blinds and light curtainsEnd user can test sensor operation with a clap of the hands GS903NGS913NRated for all types of glass including plate laminated tempered and wiredListens for the pattern of breaking glass across the frequency spectrumConsistent detection even of soft quiet glass breaks

GBP 72.73
1

Carrier 5822A-W Recessed ShatterPro II With quotPattern Recognition Technologyquot 360 - 75 m Radius Range

Carrier 5822A-W Recessed ShatterPro II With quotPattern Recognition Technologyquot 360 - 75 m Radius Range

Carrier 5822A-W Recessed ShatterPro II With Pattern Recognition Technology 360 - 75 m Radius RangeThe 5810 series acoustic glass break sensor combines high false alarm immunity and excellent detection by recognizing the exact frequency pattern generated by glass breaking. Instead of listening for a loud sound at one or two characteristic frequencies the 5810 series listens at 30 points across the glass break frequency spectrum. This not only enables it to discriminate common false alarm sources but also ensures detection of even the quietest of breaks so it can be used with blinds or light curtains. The 5810 series are recommended for perimeter loops and is designed to function in occupied areas. In 24-hour loop applications where the detector is armed all day and all night the false alarm technology will be pushed to its limit. Some sounds can duplicate the points on the glass break pattern that the 5810 series detects. Install the sensor on a perimeter loop that is armed whenever the door and window contacts are armed. The false alarm immunity is best in rooms with only moderate noise. For 24-hour occupied area protection use Sentrol shock detectors. The sensor may not consistently detect cracks in glass or bullets that break through the glass. Glass break detectors should always be backed up by interior protection.Easy to install and testAvailable in both surface and flush mount versions 5820 series installation is quick and easy. There are no sensitivity adjustments to worry about and a new test feature means only one trip up the ladder. Simply activate the tester next to the sensor and the unit goes into test mode.A unique test assures end-users that the unit is powered and ready to detect. The sensor will blink twice but will not trip when a loud hard clap is made close to the unit.Pattern Recognition TechnologyThe 5810 series detects in a full 360-coverage pattern with a 7.5 m range from detector to glass. By listening at more than 30 frequency points the sensor can tell the difference between common false alarm sources and the noise of breaking glass.Key FeaturesNew EZ design for quick and easy installationPattern Recognition Technology for superior detection and false alarm immunitySuitable for quiet occupied areas on a perimeter loopAutomatic test and user verification

GBP 62.60
1

Fike 204-0003-B Twinflex Multipoint ASD Detector - Black

Fike 204-0003-B Twinflex Multipoint ASD Detector - Black

Fike 204-0003-B Twinflex Multipoint ASD Detector - BlackThe Multipoint and ASD detectors have set new standards in detector technology. The TWINFLEX Multipoint head is a 2-wire device used with the TWINFLEX and TWINFLEX Pro systems whereas the addressable ASD detector is used on the Sita200plus Duonet and Quadnet systems. Using microprocessor control these devices offer the installer a full range of detection capabilities with audible and visual warning in one compact device for full DDA compliance.The detectors can be matched to the environment in which they are installed and changed any time during the lifetime of the installation. The mode of detection required can be changed simply by configuring the DIL switch in the detector electronics module configurable via commissioning software on addressable systems. All modes are compliant with European detector type specifications.The TWINFLEX two-wire Multipoint detector can be set to any one of 3 smoke modes 3 heat modes as well as a Combined Mode Smoke 2 and Heat 2 where a smoke or heat source can trigger a fire decision - see opposite. The end user is given optimum fire protection even if the installer is unsure of the use of the particular area where the detector is sited. All TWINFLEX products including the Multipoint detector feature an End of Line switch negating the need for end-of-line resistors.The Multipoint and ASD detectors have the unique benefit of an optional full specification integral sounder where 90dBA output can be achieved. The two-wire Multipoint detector can be set to 3 different sound patterns as well as switched off with 2 sound output levels. The addressable ASD detector has 7 different sound patterns and 3 volume settings as well as the option of a combined strobe.Key FeaturesIntegral Strobe - The Multipoint ASD can be ordered with an optional integral strobe allowing the 2-wire installation of an advanced smokeheat detector sounder and strobe in a single cost-saving device.Base LED - When the detector head is removed a base mounted LED flashes allowing users to easily identify which head is missing even from considerable distance e.g. in a high-ceiling building.Head Removal Tool - The Multipoint ASD detector removal tool fits the Solo Detector Tester pole for easy testing and maintenance at height.Optical Chamber - The Multipoint ASD detector incorporates a new advanced optical chamber for enhanced smoke detection.Colour- BlackModes of DetectionSmoke 1 Used where ionisation detectors are normally fitted especially when there are high ceilings or a risk of free burning fires chemical stores etc. or fires that need to be detected extremely quickly.Smoke 2Used where optical detectors are normally fitted when there is a risk of a smouldering fire and for escape routes.Smoke 3Designed for use in areas that are prone to nuisance alarms. The reduced sensitivity linked with a time delay feature means that a higher concentration of smoke needs to be present for a constant time period before a fire decision is made. For example this setting is ideal for hotel bedrooms with en-suite shower rooms. The installer or service engineer can change the setting from smoke 2 to smoke 3 if nuisance alarms are a problem whilst still offering optimum protection of a smoke detection setting.Heat 1 Rate of RiseUsed where a standard rate of rise detector would normally be used.Heat 2 Standard Fixed Temperature - 58C approx. Used where a standard fixed temperature heat detector would normally be fitted suitable for kitchens etc.Heat 3 High Fixed Temperature - 90C approx. Used where a high fixed temperature heat detector would normally be fitted. Suitable for commercial kitchens boiler rooms etc.

GBP 46.84
1

Fike Twinflex Multipoint ASD Detector with Sounder Strobe - 204-0012

Fike Twinflex Multipoint ASD Detector with Sounder Strobe - 204-0012

Fike Twinflex Multipoint ASD Detector with Sounder Strobe - 204-0012The Multipoint and ASD detectors have set new standards in detector technology. The TWINFLEX Multipoint head is a 2-wire device used with the TWINFLEX and TWINFLEX Pro systems whereas the addressable ASD detector is used on the Sita200plus Duonet and Quadnet systems. Using microprocessor control these devices offer the installer a full range of detection capabilities with audible and visual warning in one compact device for full DDA compliance. The detectors can be matched to the environment in which they are installed and changed any time during the lifetime of the installation. The mode of detection required can be changed simply by configuring the DIL switch in the detector electronics module configurable via commissioning software on addressable systems. All modes are compliant with European detector type specifications.The addressable ASD detector offers multiple choices for detection set to a single mode or a combination for a choice of up to 15 different settings. Programmable via a PC or at the panel Quadnet and Duonet only and also has an in-built loop isolator as well as IO for local control and switching.The TWINFLEX two-wire Multipoint detector can be set to any one of 3 smoke modes 3 heat modes as well as a Combined Mode Smoke 2 and Heat 2 where a smoke or heat source can trigger a fire decision - see opposite. The end user is given optimum fire protection even if the installer is unsure of the use of the particular area where the detector is sited. All TWINFLEX products including the Multipoint detector feature an End of Line switch negating the need for end-of-line resistors.The Multipoint and ASD detectors have the unique benefit of an optional full specification integral sounder where 90dBA output can be achieved. The two-wire Multipoint detector can be set to 3 different sound patterns as well as switched off with 2 sound output levels. The addressable ASD detector has 7 different sound patterns and 3 volume settings as well as the option of a combined strobe.Key FeaturesIntegral Strobe - The Multipoint ASD can be ordered with an optional integral strobe allowing the 2-wire installation of an advanced smokeheat detector sounder and strobe in a single cost-saving device.Base LED - When the detector head is removed a base mounted LED flashes allowing users to easily identify which head is missing even from considerable distance e.g. in a high-ceiling building.Head Removal Tool - The Multipoint ASD detector removal tool fits the Solo Detector Tester pole for easy testing and maintenance at height.Optical Chamber - The Multipoint ASD detector incorporates a new advanced optical chamber for enhanced smoke detection.Modes of DetectionSmoke 1 Used where ionisation detectors are normally fitted especially when there are high ceilings or a risk of free burning fires chemical stores etc. or fires that need to be detected extremely quickly.Smoke 2Used where optical detectors are normally fitted when there is a risk of a smouldering fire and for escape routes.Smoke 3Designed for use in areas that are prone to nuisance alarms. The reduced sensitivity linked with a time delay feature means that a higher concentration of smoke needs to be present for a constant time period before a fire decision is made. For example this setting is ideal for hotel bedrooms with en-suite shower rooms. The installer or service engineer can change the setting from smoke 2 to smoke 3 if nuisance alarms are a problem whilst still offering optimum protection of a smoke detection setting.Heat 1 Rate of RiseUsed where a standard rate of rise detector would normally be used.Heat 2 Standard Fixed Temperature - 58C approx. Used where a standard fixed temperature heat detector would normally be fitted suitable for kitchens etc.Heat 3 High Fixed Temperature - 90C approx. Used where a high fixed temperature heat detector would normally be fitted. Suitable for commercial kitchens boiler rooms etc.

GBP 60.25
1