Haes ESEN-2MAR-B MED Approved Esento 2 Zone Control Panel - Black Haes ESEN-2MAR-B MED Approved Esento 2 Zone Control Panel - BlackA 2 zone marine approved fire alarm control panel available in grey and black. Esento Marine control panels are approved by MED Lloyds Register ABS for use in all seafaring vessels. The 2 zone includes muster alarm zone settings false alarm management mode and non latching zones. N.B. No networking or repeater panelsKey Features2 zonesActivate controls via key switch or code entryCompatible with Apollo Orbis Marine detectorsIntegral detector removal monitoringEarth fault monitoring1.25 Amp switch mode power supply Nom 27V DC2 monitored sounder outputs2 Aux CO relays 1 x Fire 1 x Fault. voltage freeClass change IPAlert IPFire fault switched -ve outputsFalse alarm modeMuster alarm featureTest mode with or without soundersDisable zones sounder OPs aux OPsAlarm load 800mA shared between all sounder outputsAll sounder circuits are fused 500mA with resettable fuses GBP 318.82 1
STI STI-7531MED MED Polycarbonate Enclosure With Wire Rack amp Thumblock STI STI-7531MED MED Polycarbonate Enclosure With Wire Rack ThumblockA polycarbonate defibrillator enclosure with thumb lock access.These AED Protective Cabinets allow AED units to remain protected but still highly visible in the event of an emergency. They mount on the wall enabling appliances to be stored in a central location and are capable of housing CPR accessories. These cabinets are secured with a thumb lock allowing instant access. To further protect against misuse vandalism and accidental damage these models are fitted with a sounder and strobe light drawing immediate attention to the area.Key FeaturesClear UV-stabilised Polycarbonate EnclosureAllows visibility at almost every angleIncludes thumb lock BackplateAdjustable wire shelf GBP 296.38 1
STI STI-7533MED MED Polycarbonate Enclosure With Wire Rack Siren amp Thumblock STI STI-7533MED MED Polycarbonate Enclosure With Wire Rack Siren ThumblockA polycarbonate defibrillator enclosure with alarm facility and thumb lock access.These AED Protective Cabinets allow AED units to remain protected but still highly visible in the event of an emergency. They mount on the wall enabling appliances to be stored in a central location and are capable of housing CPR accessories. These cabinets are secured with a thumb lock allowing instant access. To further protect against misuse vandalism and accidental damage these models are fitted with a sounder and strobe light drawing immediate attention to the area.Key FeaturesClear UV-stabilised Polycarbonate EnclosureAlarm feature to prevent malicious access to enclosure contentsAllows visibility at almost every angleIncludes thumb lock BackplateAdjustable wire shelf GBP 376.75 1
STI STI-7535MED MED Protective Cabinet With Wire Rack SirenStrobe Alarm Thumblock STI STI-7535MED MED Protective Cabinet With Wire Rack SirenStrobe Alarm ThumblockA polycarbonate defibrillator enclosure with alarm facility flashing strobe and thumblock access.These AED Protective Cabinets allow AED units to remain protected but still highly visible in the event of an emergency. They mount on the wall enabling appliances to be stored in a central location and are capable of housing CPR accessories. These cabinets are secured with a thumb lock allowing instant access. To further protect against misuse vandalism and accidental damage these models are fitted with a sounder and strobe light drawing immediate attention to the area.Key FeaturesClear UV-stabilised Polycarbonate EnclosureAlarmed feature with flashing strobe to prevent malicious access to enclosure contentsAllows visibility at almost every angleIncludes thumb lock BackplateAdjustable wire shelf GBP 349.61 1
Haes ESEN-R-12MAR 12 Zone Conventional Esento MED Marine Approved Repeater Panel Haes ESEN-R-12MAR 12 Zone Conventional Esento MED Marine Approved Repeater PanelThe Esento Marine 12 way repeater panels have the same easy to use controls and indications as the main control panel. The repeaters are fully functional with Silence Resound and Reset controls as well as Disable and Test Mode functions. It is also possible to disable the controls for each or all repeater panels to make them passive indication only.The main circuit board has 2 switch ve inputs which can be used to sound or pulse the alarms. These inputs can also be re-programmed for use as PSU fault inputs. The internal comms PCB has 6 switch ve programmable outputs. The repeaters are supplied with a 1.25 amp internal power supply module. This module complies with the requirements of EN54-4 1988 and provides temperature compensated battery management charging.Key Features12 zonal fire and fault indicationsActivate controls via keyswitch or code entry1.25 Amp switch mode power supply Nom 27V DCClass change IPAlert IP6 programmable switched -ve outputsTest mode with or without soundersDisable zones sounder OPs aux OPs delays GBP 365.94 1
Haes ESEN-4MAR 4 Zone Conventional Esento MED Marine Approved Control Panel Haes ESEN-4MAR 4 Zone Conventional Esento MED Marine Approved Control PanelThe Esento Marine 2-4 panel is available with 2 or 4 conventional zones. The programming features include programmable muster alarm zones and a false alarm management mode. As standard all Esento Marine 2-4 panels provide two monitored sounder circuits Fire Fault VFCO relays and inputs to ring and pulse the sounder circuits. A separate interface card is also available to connect the panel to a ships voyage data recorder system.The panels are supplied with a 1.25 amp internal power supply module. This module complies with the requirements of EN54-4 1988 and provides temperature compensated battery management charging. Esento Marine panels are approved to European standards EN54-2 4 Fire Detection and Alarm Systems Control Indicating Equipment.Essento Marine OverviewThe Esento Marine range from Haes has been exclusively developed to address the issues of limited form and function in the conventional panels market for use at sea. Designed with the severity of the potential situation in mind these new panels are equipped with programmable delays to outputs which allow time for an investigation before invoking a full evacuation or muster alarm.Not only does this new feature-rich panel mitigate false alarms with three false alarm management mode options it also contains additional components within the casing to ensure its not disrupted by increased vibrations encountered during a journey.The panels are available from 2 - 12 zones and offer a fully comprehensive suite of programmable features for the engineer. The display uses super bright clearly labelled LED indicators and the simple colour coded buttons give the end user the confidence to correctly manage their fire alarm system.Key Features2 or 4 zonesActivate controls via keyswitch or code entryCompatible with Apollo Orbis Marine detectorsIntegral detector removal monitoringEarth fault monitoring1.25 Amp switch mode power supply Nom 27V DC2 monitored sounder outputs2 Aux CO relays 1 x Fire 1 x Fault. voltage freeClass change IPAlert IPFire fault switched -ve outputsFalse alarm modeMuster alarm featureTest mode with or without soundersDisable zones sounder OPs aux OPsAlarm load 800mA shared between all sounder outputsAll sounder circuits are fused 500mA with resettable fuses.N.B. No networking or repeater panels GBP 379.13 1
Haes ESEN-2MAR 2 Zone Conventional Esento MED Marine Approved Control Panel Haes ESEN-2MAR 2 Zone Conventional Esento MED Marine Approved Control PanelThe Esento Marine 2-4 panel is available with 2 or 4 conventional zones. The programming features include programmable muster alarm zones and a false alarm management mode. As standard all Esento Marine 2-4 panels provide two monitored sounder circuits Fire Fault VFCO relays and inputs to ring and pulse the sounder circuits. A separate interface card is also available to connect the panel to a ships voyage data recorder system.The panels are supplied with a 1.25 amp internal power supply module. This module complies with the requirements of EN54-4 1988 and provides temperature compensated battery management charging. Esento Marine panels are approved to European standards EN54-2 4 Fire Detection and Alarm Systems Control Indicating Equipment.Essento Marine OverviewThe Esento Marine range from Haes has been exclusively developed to address the issues of limited form and function in the conventional panels market for use at sea. Designed with the severity of the potential situation in mind these new panels are equipped with programmable delays to outputs which allow time for an investigation before invoking a full evacuation or muster alarm.Not only does this new feature-rich panel mitigate false alarms with three false alarm management mode options it also contains additional components within the casing to ensure its not disrupted by increased vibrations encountered during a journey.The panels are available from 2 - 12 zones and offer a fully comprehensive suite of programmable features for the engineer. The display uses super bright clearly labelled LED indicators and the simple colour coded buttons give the end user the confidence to correctly manage their fire alarm system.Key Features2 or 4 zonesActivate controls via keyswitch or code entryCompatible with Apollo Orbis Marine detectorsIntegral detector removal monitoringEarth fault monitoring1.25 Amp switch mode power supply Nom 27V DC2 monitored sounder outputs2 Aux CO relays 1 x Fire 1 x Fault. voltage freeClass change IPAlert IPFire fault switched -ve outputsFalse alarm modeMuster alarm featureTest mode with or without soundersDisable zones sounder OPs aux OPsAlarm load 800mA shared between all sounder outputsAll sounder circuits are fused 500mA with resettable fuses. GBP 318.82 1
Hochiki Marine Conventional Infrared Flame Detector DRD-EM Hochiki DRD-EM Marine Conventional Infrared Flame DetectorThe DRD-EM is a marine-approved flame detector designed for internal use to detect large flames. The detector fits the CDX marine-approved standard mounting base YBN-R6M. The detection zone is a 90 cone and the detection range is up to and including 25 m.The flame detector is designed for use where open flaming fires may be expected. It responds to the light emitted from flames during combustion. The detector discriminates between flames and other light sources by responding only to particular optical wavelengths and flame flicker frequencies. This enables the detector to avoid false alarms due to such factors as flickering light sources.The DRD-E detector can detect IR radiated from flames. Flames radiated from a fire have an IR peak emission of 4.3um occurring during the CO2 formation due to the combustion of hydrocarbons from 2 to 15 Hz.Key FeaturesClass 1 performance as defined in BS EN54-102002 range up to 25 mSingle IR technologyRobust and slim designLow current consumptionEasy to installFits the CDX marine-approved standard baseTwin LEDs for 360 viewApproved by LPCB VdSApproved to MED by GLSIL Level 2 approved variantsApplicationsCoal handling plantAircraft hangarsAutomotive industry - spray booths parts manufacturePharmaceuticalEngine roomsWaste handlingPower plantsTransformer stationsPetrochemical GBP 427.88 1