Solo 371 Replacement Smoke Generator Solo 371 Replacement Smoke Generator A replacement smoke generator for use with Solo 365.Key FeaturesField replaceable partEasily fits within Solo 365 GBP 309.34 1
Testifire XTR2 TESTIFIRE-GEN-1PK-001 Smoke Generator Pack of 1 Testifire XTR2 TESTIFIRE-GEN-1PK-001 Smoke Generator Pack of 1A replacement smoke generator for the Testifire XTR2 smoke and heat tester. GBP 297.08 1
C-Tec FPROSG Calibrated Audio Signal Generator C-Tec FPROSG Calibrated Audio Signal GeneratorEnsure your induction loop systems meet current British standards with C-Tecs innovative and very cost-effective new FPROSG Audio Signal Generator. Factory calibrated to provide a fixed audio signal the generator includes all of the test tones required to test an AFILS to BS 7594 1 kHz sine wave frequency response and metal compensation plus speech and music tracks to assist with subjective testing. GBP 252.58 1
Baldwin Boxall Ambient Noise Sensor BVRAMB Baldwin Boxall Ambient Noise Sensor BVRAMBWhen designing a voice alarm system for areas of variable levels of ambient noise which could cause problems with audibility noise sensors should be included. Correctly placed ambient noise sensors will ensure that all announcements are clearly heard.Key FeaturesTwo versions are available BVRAMB - standard version. BVRAMBIP - IP65 rated version.Monitors the ambient noise in a given area.Automatically adjusts the power of the amplifiers depending on noise level.When the area is at its quietest the level of the announcements or music will reduce.During busynoisy periods the volume level adjusts to suit.Used in conjunction with a BVRDCI CANBUS interface module which connects to the VIGIL EVAS routers.Uses a dynamic microphone capsule the output of which is amplified and converted to produce a variable current.This output is used by the BVRDCI module to produce a voltage that is proportional to the ambient noise.Band pass filtering ensures that the system only responds to ambient noise affecting the intelligibility of announcements.An on-board surveillance tone generator permanently monitors the microphone capsule. A system fault will be indicated should the microphone capsule or on-board amplifier fail.The BVRAMB includes an option to allow one of three response speeds to be selected SLOW - the system will only respond to an average change of ambient noise. MEDIUM - suitable for most installations. FAST - the system will react to short duration changes in ambient noise.Two units can be wired in parallel on the same input to monitor the ambient noise over a larger area. GBP 313.90 1
C-Tec EP203 3 Zone Automatic Extinguisher Panel LPCB Certified - EP203 C-Tec EP203 3 Zone Automatic Extinguisher Panel LPCB Certified - EP203The EP203 three zone automatic extinguisher panel has been specifically designed for use in areas housing expensive dangerous or irreplaceable items of equipment. Third-party approved by the LPCB to EN 12094-1 the European standard for Fixed Firefighting Systems - Components for Gas Extinguishing Systems and EN54 parts 2 and 4 the panel epitomises quality durability and reliability.Featuring an intuitive 128 x 64 pixel two-colour graphic display that gives clear and concise feedback to the user installer and commissioning engineer the panel also includes six monitored inputs including hold and abort a time stamped log adjustable flood times and volt-free changeover relays for fire local fire 1st stage active 2nd stage active extractor fan and fault.The panel is supplied in an elegantly styled durable enclosure with all of its electronics - apart from its powerful 3A EN54-4 switch mode PSU - mounted on a detachable metal bridge plate for ease of installation. A wide range of ancillaries are also available including remote status units hold-off and abort buttons line terminators and output expansion relay boards.Key FeaturesThird-party LPCB certificated to EN 12094 part 1 and EN54 parts 2 and 4Functions as a standard three zone fire panel with additional circuitry for controlling the release of fire-suppressing gas into protected areasUnique 128 x 64 pixel graphical display facilitates straightforward system programmingAny combination of activated zones can be programmed to automatically start the panels extinguishant release sequenceIncludes a pull-down front-panel manual release button and two keyswitches for accessing the panels functions and toggling between automanual modeThree conventional sounder circuits two x 1st stage one x 2nd stagePowerful 3A EN54-4 compliant switch mode PSULow quiescent current - less than 40mA on mains failWide range of monitored inputs and auxiliary outputs see schematicAbort and hold inputs allow the panels release sequence to be cancelled or suspended at any timeTime-stamped event logRS485 connections for up to eight flush or surface remote status units with their own LCDs manual release and mode automanual switches. Single gang economy status units without an LCD are also available.Extensive range of commissioning and engineering functionsOptional relay expansion boards and single gang abort and hold buttonsIdeal for use in computer rooms telecommunication centres archive storage areas chemical plants generator rooms museums etc..System line terminator included with all panels GBP 399.43 1