24 results (0,14489 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

Ziton ACA-BI20-025 Bracket quotIquot - 200mm 7.9quot Zintec cw Silicon sleeve - Pack of 25

Ziton ACA-TW17-025 Tie Wrap PA66 170C 338F - Pack of 25

Ziton ACA-TWSS-100 Tie Wrap Stainless Steel - Pack of 100

Nittan Programming Kit Complete

Carrier UVP-C60 60cm Ceiling Mount for UltraView PTZ Dome - Cable Management - 32 mm

Carrier UVP-C30 30cm Ceiling Mount for UltraView PTZ Dome - Cable Management - 32 mm

Aritech FE110US Ecoline Magnetic Lock 150kgs Surface Mount Unmonitored

Aritech TVP-PME-01 TruVision Multi Imager And PM Series IP PTZ Extendable Pendant Mount Bracket

Commander CS33-AC Double Tubular Extinguisher Stand - Antique Copper

Ziton ACA-BL05-100 quotLquot Bracket 50mm 2quot Zintec cw Silicon Sleeve - Pack of 100

Ziton ACA-BL20-025 quotLquot Bracket 200mm 7.9quot Zintec cw Silicon Sleeve - Pack of 25

Aritech FE130MM Ecoline Magnetic Lock 300kgs Mortice Mount Monitored

Aritech FE160MS Ecoline Magnetic Lock 600kgs Surface Mount Monitored

Carrier 6943AMP Outdoor Wired Dual Technology Curtain Detector With Antimasking 24GHz

Carbon Dioxide Extinguisher 5Kg - 5CX

Notifier M721E Analogue Addressable Dual Input Monitor and Single Output Relay Module

Notifier M721E Analogue Addressable Dual Input Monitor and Single Output Relay Module

Notifier M721E Analogue Addressable Dual Input Monitor and Single Output Relay ModuleThe M721E is designed for use with any Notifier protocol fire alarm control panel.Comes complete with end of line resistors plug-in screw connections direct decade address entry and tri-colour LEDs complete with Isolator.The newly designed platform of M700 family of InputOutput modules completes the NFXI line of wired spot detectors with unaltered family feeling and undisputed continuity.The new M700 look and feel combine maximum reliability with top-end functionality all enriched by a cutting-edge modern design.Single and multi-way models are available within the renewed mechanical package reducing both the cost of installation and the mounting space required.Their unique mechanical design allows each module to be mounted in either a common wall box on a DIN rail or its dedicated enclosure. The DIN rail mounting option is possible thanks to smart DIN brackets directly built-in the enclosure. Irrespective of the mounting methods chosen the address switch is always visible and accessible for selection.Each module has built-in short circuit protection for the communications loop however to increase application flexibility the isolators can be selecteddeselected on an individual module basis.To help technicians in the maintenance and fault-finding process light pipes have been enlarged to increase visibility even in the most challenging space constrained application. Both the status LED and the rotary switch selection can be viewed on the two sides without having to remove the cover of the surface mounting box.The multi-colour status LED provide diagnostic information regarding the status of each individual inputoutput. For ease of installation testing and maintenance modules have been equipped with quick connectors. The renovated aesthetics offers data finely engraved on the enclosures surface by laser for lifetime durability and resistance to degradation.

GBP 150.07
1

Notifier M720E Analogue Addressable Dual Input Monitor Module

Notifier M720E Analogue Addressable Dual Input Monitor Module

Notifier M720E Analogue Addressable Dual Input Monitor ModuleThe M702E is designed for use with any Notifier protocol fire alarm control panel.Comes complete with end of line resistors plug-in screw connections direct decade address entry and tri-colour LEDs complete with Isolator..The newly designed platform of M700 family of InputOutput modules completes the NFXI line of wired spot detectors with unaltered family feeling and undisputed continuity.The new M700 look and feel combine maximum reliability with top-end functionality all enriched by a cutting-edge modern design.Single and multi-way models are available within the renewed mechanical package reducing both the cost of installation and the mounting space required.Their unique mechanical design allows each module to be mounted in either a common wall box on a DIN rail or its dedicated enclosure. The DIN rail mounting option is possible thanks to smart DIN brackets directly built-in the enclosure. Irrespective of the mounting methods chosen the address switch is always visible and accessible for selection.Each module has built-in short circuit protection for the communications loop however to increase application flexibility the isolators can be selecteddeselected on an individual module basis.To help technicians in the maintenance and fault-finding process light pipes have been enlarged to increase visibility even in the most challenging space constrained application. Both the status LED and the rotary switch selection can be viewed on the two sides without having to remove the cover of the surface mounting box.The multi-colour status LED provide diagnostic information regarding the status of each individual inputoutput. For ease of installation testing and maintenance modules have been equipped with quick connectors. The renovated aesthetics offers data finely engraved on the enclosures surface by laser for lifetime durability and resistance to degradation.

GBP 108.70
1

C-Tec BF562-1 Switch Mode 24v 1.5A EN54-4 Boxed Metal PSU

C-Tec BF562-1 Switch Mode 24v 1.5A EN54-4 Boxed Metal PSU

C-Tec BF562-1 Switch Mode 24v 1.5A EN54-4 Boxed Metal PSUThe BF562-1 is certified to EN54-4A2 by the LPCB and VdS AFNOR pending. It comes with a plastic cover on PSU PCB which guards against touching live parts. Includes a single-pole voltfree changeover relay that switches for any fault condition.Key FeaturesMultiple indicators - supply present general fault fault type aux. equipment faultTwo selectable battery charge currentsBattery fault impedance limits can be optimised to suit load current helps extend battery lifeMains fail simulation modeImproved on-board temperature sensor with optional remote sensorElectronic functions comply with EN50131-6 grades 1-4 for security applicationsBF562-1E caged BF562-1C PCB-only versions availableTYPICAL USESIdeal for poweringbeam detectors auto-dial communicators aspirating smoke detectors auto-open vent systems auxiliary sounder systems or any other device performing a mandatory function of a fire alarm system.PSU CUSTOMISATIONThe BF562-1can be customised to suit your exact requirements using a BF423 configurator PC. Configurable parameters include float voltage temperature compensation battery charge rate mA battery impedance and configurableInputOutput settings. It is important to note changing the PSUs parameters in this way isoutside the scope of EN54-4 and any changes mustbe tested by the responsible person for correctoperation.PSU STATUS LEDlocated on the PSU PCB1 flash Mains Failure.2 flashes Battery Voltage Low.3 flashes Battery Voltage Critical.4 flashes Charger Failure.5 flashes Charger OK Battery is either actively charging or in float charge.6 flashes No Batteries Fitted indicating DIP Switch 4 position.7 flashes Battery Resistance Fault Level set by DIP Switch 2 position.8flashes Output Over Voltage.BATTERY FAULT MONITORINGThe BF562-1 complies with EN54-4A2 and therefore must monitor battery resistance. The fault threshold is directly related to the ability of the battery to deliver the rated current to the load. For example batteries stored uncharged for long periods during shipment andor distribution degrade leading to increased internal resistance. If a degraded battery is fitted a fault will be shown by the PSU as mandated by EN54-4A2.DATA PORTData on the BF562-1s status can be extracted from the PSUsbi-directional data port. The data availableincludes thermistor measurements battery terminal voltage system voltage at load terminals battery charge current load current battery impedanceandASCII text string status messages. Extracting this data requires additional equipment and permissions - contact C-TEC for details.

GBP 155.72
1

C-Tec BF560-12 Switch Mode 12v 2A EN54-4 Boxed PSU

C-Tec BF560-12 Switch Mode 12v 2A EN54-4 Boxed PSU

C-Tec BF560-12 Switch Mode 12v 2A EN54-4 Boxed PSUThe C-Tec BF560-12 12V 2A EN54-4 Switch Mode PSU is ideal for connecting to 12V security STUs to provide BS5839-1 compliant remote monitoring facilities. It is certified to EN54-4A2 by the LPCB VdS AFNOR pending.Key FeaturesMultiple indicators - supply present general fault fault type aux. equipment fault.Two selectable battery charge currents.Battery fault impedance limits can be optimised to suit load current helps extend battery life.Mains fail simulation mode.Improved on-board temperature sensor with optional remote sensor.Ideal for connecting to 12V security STUs to provide BS5839-1 compliant remote monitoring facilities.Electronic functions comply with EN50131-6 grades 1-4 for security applications.BF560-12E Caged BF560-12C PCB-only versions available.Plastic cover on PSU PCB guards against touching live parts.Includes a single-pole voltfree changeover relay that switches for any fault condition.Additional InformationPSU CUSTOMISATIONThe BF560-12can be customised to suit your exact requirements using a BF423 configurator PC. Configurable parameters include float voltage temperature compensation battery charge rate mA battery impedance and configurableInputOutput settings. It is important to note changing the PSUs parameters in this way isoutside the scope of EN54-4 and any changes mustbe tested by the responsible person for correctoperation.12V SECURITY STUUSED PURELY FOR FIRE ALARM SIGNALLINGThe BF560-12 can help combat an area of fire alarm system non-compliance that is often overlooked - their connection to remote monitoring centres via 12V security STUs or autodiallers. Firesystems that require such monitoring are typically connected to 12V security STUs. Unfortunately PSUs used to power these STUs normally only offer 12 hours standby are notconnected to a dedicated mains supply and do not include the features demanded by EN54-4 such as battery impedance monitoring temperature compensated charging CPR compliance etc. TheBF560-12 solves these problems by allowing the use of 12V STUs with a cost-effective EN54-4 compliant PSU thereby facilitating compliance with BS5839-1 or European equivalents. Tofurther assist this application an optional STU mounting plate is available for inside the BF560-12 order code BF360SP.PSU STATUS LEDlocated on the PSU PCB1 flash Mains Failure.2 flashes Battery Voltage Low.3 flashes Battery Voltage Critical.4 flashes Charger Failure.5 flashes Charger OK Battery is either actively charging or in float charge.6 flashes No Batteries Fitted indicating DIP Switch 4 position.7 flashes Battery Resistance Fault Level set by DIP Switch 2 position.8flashes Output Over Voltage.BATTERY FAULT MONITORINGThe BF560-12 complies with EN54-4A2 and therefore must monitor battery resistance. The fault threshold is directly related to the ability of the battery to deliver the rated current to the load. For example batteries stored uncharged for long periods during shipment andor distribution degrade leading to increased internal resistance. If a degraded battery is fitted a fault will be shown by the PSU as mandated by EN54-4A2.EN50131-6 POWER SUPPLIES FOR INTRUSION HOLD UP ALARMS CAPABILITYThe power supply inside the BF560-12 has all the electrical functions required to comply with EN50131-6 Grade 4which includes Grades 3 2 and 1. However the BF560-12s enclosure isnot designed to comply with the standardsrequirements totriggeranalarm if someone tries to force the box open. OEM security companies interested in utilising the BF560-12s PSUPCB inside their own EN50131-6 compliant tamper-resistant enclosures should contact our marketing departmentfor further detailson costs and approvals.DATA PORTData on the BF560-12s status can be extracted from the PSUsbi-directional data port. The data availableincludes thermistor measurements battery terminal voltage system voltage at load terminals battery charge current load current battery impedanceandASCII text string status messages. Extracting this data requires additional equipment and permissions -call C-TEC for details.

GBP 113.64
1