208 results (0,15004 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

Vimpex Single Loop Sounder Controller DINT1

Fireclass 557.202.612FC PMM840 - 40 V PSU - 40V Regulated Loop Supply Loop 3 and 4 Expansion

Fike Sita Loop Control Module 803-0022

C-Tec ML1K ML1 Hearing Loop System

Fike Sita Loop Input Output Module 803-0006

C-Tec CL1 Mini-Counter Hearing Loop Amplifier Only

Morley PL-LIB01S Morley-IAS Second Loop Card For PL-1000 V2

Aritech LC1502 12002000 2 Loop Extension Card With On Board Supply

Hyfire HFI-ABSB-23W-06 Intelligent Plus Loop Powered Base SounderVAD EN54 White Lens Altair

Hyfire HFI-ABSB-23R-06 Intelligent Plus Loop Powered Base SounderVAD EN54 Red lens - Altair

International Gas Detectors TOC-MA-ISO 4-20mA Loop Isolator - Single Channel

Aritech AS964WI 950 Series Intelligent Loop Powered Open-Area Sounder with Isolator White

Ziton ZP752-2 Addressable Loop Interface Unit 13810-ZT

Ziton ZP752-2 Addressable Loop Interface Unit 13810-ZT

Ziton ZP752-2 Addressable Loop Interface Unit 13810-ZTThe ZP752-2 is a loop wired interface providing two conventional alarm circuits. It may programmed to operate from a single address a group or zone of devices or as a common output from any trigger device connected to the system.Power for the alarm circuits is supplied either from an external power supply unit or directly from the panels 24VDC supply via separate wiring. The ZP752-2 monitors its power supply and failure is reported to the main control panel automatically.On operation both sounder circuits are simultaneously activated. A red LED indicator is illuminated on the front of the unit to confirm operation.Fully monitored for open and short circuit faultsAny number of ZP752-2 units up to a max of 127 can be connected to the ZP loop. In systems complying with the recommendations of BS5839-1 where sounder response to the operation of a manual call point must be within 3 seconds up to 16 ZP752-2 output units assigned to the first 16 addresses on each loop can be operated within the time period.Wiring is monitored for open and short circuit faults by means of end of line resistors. Faults are automatically reported to the control panel together with the address of the ZP752-2 interface. An amber LED indicator on the front of the moulding is illuminated to indicate the fault condition.First and second fix installationDesigned for first and second fix installation the unit comprises an open back box containing all wiring terminals together with a front plate enclosure of high impact plastic housing all electronics printed circuit boards and selection switches. The two parts simply plug together prior to system completion.All loop devices incorporate switch settings enabling them to be assigned a unique address which is polled by the panel every two seconds.Key FeaturesTwo monitored sounder circuitsSupport for 3s response from manual call pointsAddressable - connects to ZP loopProgrammable for continuous or pulsed output

GBP 98.81
1