Aritech AS250 Internal Speaker White Plastic 8 Ohm impedance 10W Aritech AS250 Internal Speaker White Plastic 8 Ohm impedance 10WAn indoor speaker for vocal communication.Key FeaturesSpeaker for indoor applicationsSuitable for vocal communicationAccessory group SirenType Indoor sirenDimensions W x H x D 110 x 100 x 55 mmColour WhitePower rating 10 WImpedance 8 ohmsMaterial Plastic GBP 17.06 1
Elmdene TS443-8T 8 Ohm Ext Speaker cw Tamper - White Polycarbonate - 110 x 110 x 55 Elmdene TS443-8T 8 Ohm Ext Speaker cw Tamper - White Polycarbonate - 110 x 110 x 55The TS443-8T is apart of a range of Extension Speakers for intruder alarm systems.8 Ohm units available rated at 20W and housed in a polycarbonate enclosure.Key Features8 and 16 Ohm units available20W ratingPolycarbonate enclosure3 year warrantyDimensions 110 H x 110 W x 55 D GBP 10.78 1
Cooper Menvier EF-CS6-130-PASB 130mm 6W Ceiling Loudspeaker PA Cooper Menvier EF-CS6-130-PASB 130mm 6W Ceiling LoudspeakerPAEconomical one-piece ceiling speaker for public addressapplications. 6W flush mount ceiling loudspeaker. The speaker is fitted with a100V70V transformer which has three power adjustment tappings. This modern speaker has a powder coated metal chassis andgrill that provides long term resistance to corrosion. The flat constructionallows a low mounting depth of only 70mm. Quick and easy ceiling mounting isprovided using spring clamps suitable for ceiling thickness of 2mm to 42mm. Please note Because of the many different types of ceilingmaterials and ceiling strengths it should be ensured that the ceiling strengthis suitable for the weight of the speaker.Key FeaturesQuick mount easy installation100V70V line transformer GBP 16.37 1
Electro-Detectors EDA-Q740 Call Point Body Electro-Detectors EDA-Q740 Call Point BodyA spare or replacement Call Point Body for use with the Electro Detectors Zerio Plus wireless fire alarm system call points. GBP 10.54 1
Electro-Detectors EDA-Q665 Detector Battery Board Red For Millennium amp Zerio Detectors Electro-Detectors EDA-Q665 Detector Battery Board Red For Millennium Zerio DetectorsThe EDA-Q665 is a replacement 2 cell lithium battery pack for use with Electro Detectors wireless fire alarm system detectors.Older versions of this battery pack had the code ED8291 marking on it. GBP 14.58 1
Cooper Fulleon 587025FULL-0243 Squashni Micro Base Sounder - 12V DC - White Housing - Cover Included Cooper Fulleon 587025FULL-0243 Squashni Micro Base Sounder - 12V DC - White Housing - Cover IncludedThe Fulleon Squashni Micro is an extremely efficient base fire alarm sounder that offers low power operation in a discrete 35mm housing. Delivering a low power requirement and a high quality clean finish without compromising on safety.The Squashni Micro which also acts as a fixing platform for detector bases is available in red and white housing.Transducer speaker technology allows the Squashni micro to generate an SPL of up to 97dB or can be used on a lower SPL setting to reduce the current draw to only 3mA.Key FeaturesCertified to EN54White HousingCover Included12V DCVdS approvedA compact design for unobtrusive indoor applicationsUniversal point detector platform allows a discreet ceiling installation GBP 15.50 1
KAC M2A-R680SG-K013-01 Red Surface Break Glass Indoor Call Point Flame 680 OHM KAC M2A-R680SG-K013-01 Red Surface Break Glass Indoor Call Point Flame 680 OHMThe KAC range of Call Points are fully compliant with the latest standards is essential and the new MCP indoor call point range is fully approved to the latest EN54-11 standard compliant markings only. All MCP2 products are supplied with an LED indicator as standard.Key FeaturesUnique Plug Play installation conceptTotal Flex-Ability in the choice of operating elementAnti-Tamper facilityEnhanced aesthetics and compact designFully approved to the latest standardsBackward compatibilityCPD Approved GBP 16.01 1
KAC MCP1A-R-470-SR-IS Red Intrinsically Safe Call Point - Surface - 470Ohm KAC MCP1A-R-470-SR-IS Red Intrinsically Safe Call Point - Surface - 470OhmThe MCP1A-R-470-SR-IS is a Red Intrinsically Safe Call Point.Installation efficiency flexibility and full compliance with the latest standards are at the heart of the new MCP indoor call point range.Installation time and ultimately cost are of paramount importance to any fire or security installer. The MCP range directly reflects this need by providing a unique plug and play concept designed specifically to reduce installation time. All new MCP products utilise a special terminal block where all initial installation cabling is terminated. This terminal block is then simply connected to the back of the MCP. Simple but effective with no re-termination required and no time wasted.Through new standards and legislation both break glass and resettable operating elements can now be used within a manual call point. To provide you with the greatest flex-ability the new MCP range can be configured as either a break glass or resettable unit by simply changing from one element to another. No other additional parts or alternative products need to be ordered.All MCP indoor call point products also help preserve the integrity of the overall system as illegal removal of the product lid will result in the call point operating and the system going into alarm.Full compliance with the latest standards is essential and the new MCP indoor call point range is fully approved to the latest EN54-11 standard Compliant markings only.The MCP1A product version is supplied with both a resistor and normally open clean contact electrical options.Key FeaturesColour Red470OhmUnique Plug Play installation conceptTotal Flex-Ability in the choice of operating elementAnti-Tamper facilityEnhanced aestheticsFully approved to the latest standardsBackward compatibility GBP 14.01 1
KAC M2A-R470SG-K013-01 Red Break Glass Call Point with LED - 470 Ohm Surface KAC M2A-R470SG-K013-01 Red Break Glass Call Point with LED - 470 Ohm SurfaceInstallation efficiency flexibility and full compliance with the latest standards are at the heart of the new MCP indoor call point range.Installation time and ultimately cost are of paramount importance to any fire or security installer. The MCP range directly reflects this need by providing a unique plug and play concept designed specifically to reduce installation time. All new MCP products utilise a special terminal block where all initial installation cabling is terminated. This terminal block is then simply connected to the back of the MCP. Simple but effective with no re-termination required and no time wasted.Through new standards and legislation both break glass and resettable operating elements can now be used within a manual call point. To provide you with the greatest flex-ability the new MCP range can be configured as either a break glass or resettable unit by simply changing from one element to another. No other additional parts or alternative products need to be ordered.All MCP indoor call point products also help preserve the integrity of the overall system as illegal removal of the product lid will result in the call point operating and the system going into alarm.Full compliance with the latest standards is essential and the new MCP indoor call point range is fully approved to the latest EN54-11 standard compliant markings only.All MCP2 products are supplied with an LED indicator as standard.The MCP2A Product version is supplied with both an LEDresistor and normally open clean contact electrical options. These options are simply utilised by attaching the terminal block to the required connection in the back of the MCP product.Key FeaturesColour Red470OhmUnique Plug Play installation conceptTotal Flex-Ability in the choice of operating elementAnti-Tamper facilityEnhanced aestheticsFully approved to the latest standardsBackward compatibilityCPD Approved GBP 14.22 1
KAC MCP1A-R-470-SR-R Red Manual Call Point - 470 Ohm Surface - Resettable KAC MCP1A-R-470-SR-R Red Manual Call Point - 470 Ohm Surface - ResettableThe MCP1A-R-470-SR-R is a Red Resettable Manual Call Point.Installation efficiency flexibility and full compliance with the latest standards are at the heart of the new MCP indoor call point range.Installation time and ultimately cost are of paramount importance to any fire or security installer. The MCP range directly reflects this need by providing a unique plug and play concept designed specifically to reduce installation time. All new MCP products utilise a special terminal block where all initial installation cabling is terminated. This terminal block is then simply connected to the back of the MCP. Simple but effective with no re-termination required and no time wasted.Through new standards and legislation both break glass and resettable operating elements can now be used within a manual call point. To provide you with the greatest flex-ability the new MCP range can be configured as either a break glass or resettable unit by simply changing from one element to another. No other additional parts or alternative products need to be ordered.All MCP indoor call point products also help preserve the integrity of the overall system as illegal removal of the product lid will result in the call point operating and the system going into alarm.Full compliance with the latest standards is essential and the new MCP indoor call point range is fully approved to the latest EN54-11 standard Compliant markings only.The MCP1A product version is supplied with both a resistor and normally open clean contact electrical options.Key FeaturesColour Red470OhmResettableUnique Plug Play installation conceptTotal Flex-Ability in the choice of operating elementAnti-Tamper facilityEnhanced aestheticsFully approved to the latest standardsBackward compatibilityCPD Approved GBP 11.15 1
KAC M1A-R680SG-STCK-01 Red Break Glass Call Point - 680Ohm - Surface - House Flame KAC M1A-R680SG-STCK-01 Red Break Glass Call Point - 680Ohm - Surface - House FlameThe M1A-R680SG-STCK-01 is a Red Break Glass Call Point.Installation efficiency flexibility and full compliance with the latest standards are at the heart of the new MCP indoor call point range.Installation time and ultimately cost are of paramount importance to any fire or security installer. The MCP range directly reflects this need by providing a unique plug and play concept designed specifically to reduce installation time. All new MCP products utilise a special terminal block where all initial installation cabling is terminated. This terminal block is then simply connected to the back of the MCP. Simple but effective with no re-termination required and no time wasted.Through new standards and legislation both break glass and resettable operating elements can now be used within a manual call point. To provide you with the greatest flex-ability the new MCP range can be configured as either a break glass or resettable unit by simply changing from one element to another. No other additional parts or alternative products need to be ordered.All MCP indoor call point products also help preserve the integrity of the overall system as illegal removal of the product lid will result in the call point operating and the system going into alarm.Full compliance with the latest standards is essential and the new MCP indoor call point range is fully approved to the latest EN54-11 standard Compliant markings only.The MCP1A product version is supplied with both a resistor and normally open clean contact electrical options.Key FeaturesColour Red680OhmUnique Plug Play installation conceptTotal Flex-Ability in the choice of operating elementAnti-Tamper facilityEnhanced aestheticsFully approved to the latest standardsBackward compatibilityCPD Approved GBP 13.44 1
KAC M1A-B470SF-K013-11 Blue Break Glass Call Point - 470 Ohm Surface - Resettable KAC M1A-B470SF-K013-11 Blue Break Glass Call Point - 470 Ohm Surface - ResettableThe M1A-B470SF-K013-11 is a resettable Blue Break Glass Call Point.Installation efficiency flexibility and full compliance with the latest standards are at the heart of the new MCP Indoor Call Point range. Installation time and ultimately cost are of paramount importance to any fire or security installer. The MCP range directly reflects this need by providing a unique plug and play concept designed specifically to reduce installation time. All new MCP products utilise a special terminal block where all initial installation cabling is terminated. This terminal block is then simply connected to the back of the MCP. Simple but effective with no re-termination required and no time wasted.Both break glass and resettable operating elements can now be used within a manual call point. To provide you with the greatest flex-ability the new MCP range can be configured as either a break glass or resettable unit by simply changing from one element to another. No other additional parts or alternative products need to be ordered.All MCP Indoor Call Point products also help preserve the integrity of the overall system as illegal removal of the product lid will result in the call point operating and the system going in to alarm.The MCP1A product version is supplied with both a resistor and normally open clean contact electrical options. These options are easily utilised by simply connecting the terminal block to the required connection in the back of the MCP1 product. A variety of resistor versions are available with both 470W and 680W offered as standard. However other resistor types can be provided upon request.Key FeaturesColour BlueResettableUnique Plug Play installation conceptTotal Flex-Ability in the choice of operating elementAnti-Tamper facilityEnhanced aestheticsFully approved to the latest standardsBackward compatibilityPlease note The image is for illustative purposes only. GBP 17.18 1
Apollo Marine Isolating Base 45681-286MAR Apollo Marine Isolating Base 45681-286MARThe Isolating Base senses and isolates short circuit faults on XP95 and Discovery loops and spurs.OperationUnder normal operating conditions a low impedance is present between the IN and OUT terminals of the base so that power and signals pass to the next base in line. If a short-circuit or abnormally low impedance occurs the fall in voltage is sensed and the base isolates the negative supply in the direction of the fault.The isolated section is tested using a current pulse every five seconds. When the short-circuit is removed the power will automatically be restored. If it is a requirement that no device is lost in the event of a single short-circuit fault every detector should be fitted to an isolating base. In applications where it is not necessary to use an isolating base for each detector up to twenty detectors or equivalent surge current may be installed between isolating bases.Key FeaturesUp to 20 detectors or their equivalent load may be installed between isolating basesHigh-brightness LEDDetects wiring short-circuitsMinimises disruption from short-circuits GBP 16.81 1
KAC M3A-R000SG-STCK-01 Red Break Glass Call Point - NONC Surface - House Flame KAC M3A-R000SG-STCK-01 Red Break Glass Call Point - NONC Surface - House FlameInstallation efficiency flexibility and full compliance with the latest standards are at the heart of the new MCP indoor call point range.Installation time and ultimately cost are of paramount importance to any fire or security installer. The MCP range directly reflects this need by providing a unique plug and play concept designed specifically to reduce installation time. All new MCP products utilise a special terminal block where all initial installation cabling is terminated. This terminal block is then simply connected to the back of the MCP. Simple but effective with no re-termination required and no time wasted.Through new standards and legislation both break glass and resettable operating elements can now be used within a manual call point. To provide you with the greatest flex-ability the new MCP range can be configured as either a break glass or resettable unit by simply changing from one element to another. No other additional parts or alternative products need to be ordered.All MCP indoor call point products also help preserve the integrity of the overall system as illegal removal of the product lid will result in the call point operating and the system going into alarm.Full compliance with the latest standards is essential and the new MCP indoor call point range is fully approved to the latest EN54-11 standard compliant markings only.The MCP3A product version is supplied with one normally open and one normally closed contact. Selecting either the Normally Open or Normally Closed contact is easily achieved by simply connecting the terminal block to the required connection in the back of the MCP3 Product. Single pole changeover switching can be achieved with the use of two terminal blocks.Key FeaturesUnique Plug Play installation conceptTotal Flex-Ability in the choice of operating elementAnti-Tamper facilityEnhanced aestheticsFully approved to the latest standardsBackward compatibilityCPD Approved GBP 12.05 1
KAC M3A-Y000FG-K013-54 Yellow NONC Contact Model Flush Glass Indoor Manual Call Point Extinguishant Release Marking And Hinge Cover KAC M3A-Y000FG-K013-54 Yellow NONC Contact Model Flush Glass Indoor Manual Call Point Extinguishant Release Marking And Hinge CoverInstallation efficiency flexibility and full compliance with the latest standards are at the heart of the new MCP indoor call point range.Installation time and ultimately cost are of paramount importance to any fire or security installer. The MCP range directly reflects this need by providing a unique plug and play concept designed specifically to reduce installation time. All new MCP products utilise a special terminal block where all initial installation cabling is terminated. This terminal block is then simply connected to the back of the MCP. Simple but effective with no re-termination required and no time wasted.Through new standards and legislation both break glass and resettable operating elements can now be used within a manual call point. To provide you with the greatest flex-ability the new MCP range can be configured as either a break glass or resettable unit by simply changing from one element to another. No other additional parts or alternative products need to be ordered.All MCP indoor call point products also help preserve the integrity of the overall system as illegal removal of the product lid will result in the call point operating and the system going into alarm.Full compliance with the latest standards is essential and the new MCP indoor call point range is fully approved to the latest EN54-11 standard compliant markings only.The MCP3A product version is supplied with one normally open and one normally closed contact. Selecting either the Normally Open or Normally Closed contact is easily achieved by simply connecting the terminal block to the required connection in the back of the MCP3 Product. Single pole changeover switching can be achieved with the use of two terminal blocks.Key FeaturesUnique Plug Play installation conceptTotal Flex-Ability in the choice of operating elementAnti-Tamper facilityEnhanced aestheticsFully approved to the latest standards GBP 16.90 1
KAC M3A-R000SG-K013-81 Red Indoor Manual Call Point With House Flame Marking - Normally OpenNormally Close NONC- Surface - Break Glass KAC M3A-R000SG-K013-81 Red Indoor Manual Call Point With House Flame Marking - Normally OpenNormally Close NONC- Surface - Break GlassInstallation efficiency flexibility and full compliance with the latest standards are at the heart of the new MCP indoor call point range.Installation time and ultimately cost are of paramount importance to any fire or security installer. The MCP range directly reflects this need by providing a unique plug and play concept designed specifically to reduce installation time. All new MCP products utilise a special terminal block where all initial installation cabling is terminated. This terminal block is then simply connected to the back of the MCP. Simple but effective with no re-termination required and no time wasted.Through new standards and legislation both break glass and resettable operating elements can now be used within a manual call point. To provide you with the greatest flex-ability the new MCP range can be configured as either a break glass or resettable unit by simply changing from one element to another. No other additional parts or alternative products need to be ordered.All MCP indoor call point products also help preserve the integrity of the overall system as illegal removal of the product lid will result in the call point operating and the system going into alarm.Full compliance with the latest standards is essential and the new MCP indoor call point range is fully approved to the latest EN54-11 standard compliant markings only.The MCP3A product version is supplied with one normally open and one normally closed contact. Selecting either the Normally Open or Normally Closed contact is easily achieved by simply connecting the terminal block to the required connection in the back of the MCP3 Product. Single pole changeover switching can be achieved with the use of two terminal blocks.Key FeaturesUnique Plug Play installation conceptTotal Flex-Ability in the choice of operating elementAnti-Tamper facilityEnhanced aestheticsFully approved to the latest standardsBackward compatibilityCPD Approved GBP 16.99 1
KAC M3A-R000SF-STCK-01 Red NONC Contact Model Surface Flexi Element Indoor Manual Call Point With House Flame Marking KAC M3A-R000SF-STCK-01 Red NONC Contact Model Surface Flexi Element Indoor Manual Call Point With House Flame MarkingInstallation efficiency flexibility and full compliance with the latest standards are at the heart of the new MCP indoor call point range.Installation time and ultimately cost are of paramount importance to any fire or security installer. The MCP range directly reflects this need by providing a unique plug and play concept designed specifically to reduce installation time. All new MCP products utilise a special terminal block where all initial installation cabling is terminated. This terminal block is then simply connected to the back of the MCP. Simple but effective with no re-termination required and no time wasted.Through new standards and legislation both break glass and resettable operating elements can now be used within a manual call point. To provide you with the greatest flex-ability the new MCP range can be configured as either a break glass or resettable unit by simply changing from one element to another. No other additional parts or alternative products need to be ordered.All MCP indoor call point products also help preserve the integrity of the overall system as illegal removal of the product lid will result in the call point operating and the system going into alarm.Full compliance with the latest standards is essential and the new MCP indoor call point range is fully approved to the latest EN54-11 standard compliant markings only.The MCP3A product version is supplied with one normally open and one normally closed contact. Selecting either the Normally Open or Normally Closed contact is easily achieved by simply connecting the terminal block to the required connection in the back of the MCP3 Product. Single pole changeover switching can be achieved with the use of two terminal blocks.Key FeaturesUnique Plug Play installation conceptTotal Flex-Ability in the choice of operating elementAnti-Tamper facilityEnhanced aestheticsFully approved to the latest standards GBP 14.58 1
KAC M1A-R470SG-K013-81 Red Intrinsically Safe Break Glass Indoor Manual Call Point House Flame Logo KAC M1A-R470SG-K013-81 Red Intrinsically Safe Break Glass Indoor Manual Call Point House Flame LogoThese Intrinsically Safe version of call points are manufactured to protect against other hazards as defined in paragraph 1.2.7 of annex II of the ATEX Directive 949EC. They are intended for use within Intrinsically Safe I.S. systems using suitable I.S. barriers. For a list of suitable barriers see reverse.Installation efficiency flexibility and full compliance with the latest standards are at the heart of the new Indoor Call Point range. Installation time and ultimately cost are of paramount importance to any fire or security installer. The MCP range directly reflects this need by providing a unique plug and play concept designed specifically to reduce installation time. All new MCP products utilise a special terminal block where all initial installation cabling is terminated. This terminal block is then simply connected to the back of the MCP. Simple but effective with no re-termination required and no time wasted.Through new standards and legislation both break glass and resettable operating elements can now be used within a manual call point. To provide you with the greatest flex-ability the new MCP range can be configured as either a break glass or resettable unit by simply changing from one element to another. No other additional parts or alternative products need to be ordered.All MCP Indoor Call Point products also help preserve the integrity of the overall system as illegal removal of the product lid will result in the call point operating and the system going in to alarm.The MCP1A product version is supplied with both a resistor and normally open clean contact electrical options. These options are easily utilised by simply connecting the terminal block to the required connection in the back of the MCP1 product. A variety of resistor versions are available with both 470W and 680W offered as standard. However other resistor types can be provided upon request. The MCP1B product version allows for connection to Savwire systems.Key FeaturesUnique Plug Play installation conceptTotal Flex-Ability in the choice of operating elementAnti-Tamper facilityEnhanced aestheticsFully approved to the latest standardsBackward compatibility GBP 16.99 1
Apollo Series 65 Optical Smoke Detector - 55000-317APO Apollo Series 65 Optical Smoke Detector - 55000-317The Series 65 Optical Smoke Detector incorporates a pulsing LED located within the housing of the detector. The external detector moulding is identical to that of the ionisation detector but has an indicator LED which is clear in quiescent state but produces a red light in alarm. As part of the Apollo Series 65 Detector Range the 55000-317 Optical Conventional Smoke Detector offers a fire detection solution to many applications. The detector can be used with most modern conventional fire alarm panels.The Apollo Series 65 conventional optical smoke detector 55000-317 uses an internal pulsing LED and a photo-diode at an obtuse angle. In the event of smoke entering the chamber the light pulse from the LED will be scattered and registered by the photo-diode. The detector will then enter the alarm state and the indicator LED lights up. The Apollo Series 65 optical smoke detector housing is identical to that of the Apollo ionisation smoke detector but has an indicator LED which is clear in quiescent state but produces red light in alarm.Key Features Wide operating voltageAdvanced electronic technologyFlashing LEDoptionMagnetic test switch optionCan be used on security systemsElectrically compatible with Series 60Mechanically compatible with Series 60Proven detection performanceDesigned to meet approvals worldwideRange of bases available GBP 16.52 1
KAC M1B-R470SG-STCK-01 Break Glass Call Point Red SavWire Surface KAC M1B-R470SG-STCK-01 Break Glass Call Point Red SavWire SurfaceThe M1B-R470SG-STCK-01 is Twin wire call manual point. The KAC offer an unparalleled range of indoor and outdoor break glass re-settable and key operated call points.KAC Alarm Company is the Worlds largest manufacturer of manual call points used in commercial fire and security systems.With over 40 years industry experience they are one of the longest serving brands in emergency evacuation safety.The latest MCP ranges have dual connection options with the use of the patented plug play terminal block concept. After wiring the terminal connector plug into the appropriate position.The 1B models are supplied with a 470 resistor fitted in series but can also be connected without the resistor short cct. They have a Single Pole changeover contact rated at 30vdc. Normally Open only.3A models have no resistor fitted. They have a Single Pole changeover contact rated at 30vdc which can be wired Normally Open or Normally Closed.Key FeaturesUnique Plug Play installation conceptTotal Flex-Ability in the choice of operating elementAnti-Tamper facilityEnhanced aestheticsFully approved to the latest standardsBackward compatibilityCPD Approved GBP 16.60 1
KAC M3A-GC01SF-K013-12 Single Pole Changeover Contact Call Point - Green KAC M3A-GC01SF-K013-12 Single Pole Changeover Contact Call Point - GreenInstallation efficiency and flexibility are at the heart of the new MCP Indoor Call Pointrange.Installation time and ultimately cost are of paramount importance to any fire or securityinstaller. The MCP range directly reflects this need by providing a unique plug and playconcept designed specifically to reduce installation time. All new MCP products utilisea special terminal block where all initial installation cabling is terminated. This terminalblock is then simply connected to the back of the MCP. Simple but effective with nore-termination required and no time wasted.Both break glass and resettable operating elements can now be used within a manualcall point. To provide you with the greatest flex-ability the new MCP range can beconfigured as either a break glass or resettable unit by simply changing from one elementto another. No other additional parts or alternative products need to be ordered.All MCP Indoor Call Point products also help preserve the integrity of the overall systemas illegal removal of the product lid will result in the call point operating and the systemgoing in to alarm.Key FeaturesColour Green GBP 13.97 1
Nittan EVC-P Photoelectrical Optical Smoke Detector Nittan EVC-P Photoelectrical Optical Smoke Detector with 375 Ohm ResistorUsing a simple but effective technique the EVC-P Optical Detector incorporates a chamber housing an Infra-Red IR LED light and a photodiode light detector set at an obtuse angle preventing it from seeing the light. When smoke enters the chamber the light bounces off the smoke particles and strikes the photodiode causing it to generate an alarm condition when a set threshold value is met.The EVC-P Optical Detector is therefore more sensitive to larger smoke particles which tend to be caused by smouldering fires rather than fast flaming fires.OperationThe smoke chamber of the EVC-P is constructed so that light cannot enter from outside but smoke can pass through the chamber slots. The EVC-P utilises the light scatter sensing principle. The LED pulses every 8 seconds to maintain a low monitoring current. A quick charge time 20 seconds is also achieved. The detector incorporates an alarm verification function which requires two successive pulses before an alarm is given.The interval between the first and second pulse is automatically reduced to four seconds after the first alarm level is monitored. The detector design provides strong immunity to air velocities contamination and RF interference. The geometry of the smoke chamber and optics support assembly is designed to give the best possible signal to noise ratio resulting in excellent response characteristics.Key FeaturesOmniview 360 LEDInternal Alarm Current Limiting ResistorWide Operational Voltage Range 12v-32vOptical Detector GBP 15.60 1
Carrier 5150-W 2-Wire On-The-Glass Piezo Sensor With 30 cm Wire Leads NC Alarm Output Carrier 5150-W 2-Wire On-The-Glass Piezo Sensor With 30 cm Wire Leads NC Alarm OutputThe Sentrol 5150 series glass break detector has been designed using the latest electronic techniques. This enables the detector to contain all the necessary circuitry for excellent detection whilst filtering out and rejecting all unwanted signals that would normally result in a nuisance alarms e.g. ultra-sound radio frequency interference etc. The 5150 series will provide a 3 m radius of protection. Suitable for use on standard window glass plate wired tempered and laminated glass.Due to the design of the product the detector may be fitted as close as 2.5 cm from the window frame and still provide a full 3 m radius. The 5150 series detectors are passive sensors therefore any number of detectors may be installed on the same windowpane without the risk of interaction. The detectors use a fail-safe normally closed open to alarm relay contact enabling compatibility with any standard burglar alarm control equipment.The output from the relay contact should be connected via the alarm 24-hour tamper loop in order to provide early signalling at the control whether the alarm is switched on or off. The opening of the normally closed relay contact signals the alarm.Easily installs with pre-cut specially formulated 3M adhesive tape.Key Features3 m radius of coverage measured from the sensorProtects all glass types up to a standard thickness of 6.4 mm includingplate wired tempered and laminated glassIdeal for 24-hours loop protectionTwo wire sensor drawing no power from the loopCompatible with most wireless transmitters GBP 12.82 1
Carrier 5150-M 2-Wire On-The-Glass Piezo Sensor With 30 cm Wire Leads NC Alarm Output Carrier 5150-M 2-Wire On-The-Glass Piezo Sensor With 30 cm Wire Leads NC Alarm OutputThe Sentrol 5150 series glass break detector has been designed using the latest electronic techniques. This enables the detector to contain all the necessary circuitry for excellent detection whilst filtering out and rejecting all unwanted signals that would normally result in a nuisance alarms e.g. ultra-sound radio frequency interference etc. The 5150 series will provide a 3 m radius of protection. Suitable for use on standard window glass plate wired tempered and laminated glass.Due to the design of the product the detector may be fitted as close as 2.5 cm from the window frame and still provide a full 3 m radius. The 5150 series detectors are passive sensors therefore any number of detectors may be installed on the same windowpane without the risk of interaction. The detectors use a fail-safe normally closed open to alarm relay contact enabling compatibility with any standard burglar alarm control equipment.The output from the relay contact should be connected via the alarm 24-hour tamper loop in order to provide early signalling at the control whether the alarm is switched on or off. The opening of the normally closed relay contact signals the alarm.Easily installs with pre-cut specially formulated 3M adhesive tape.Key Features3 m radius of coverage measured from the sensorProtects all glass types up to a standard thickness of 6.4 mm includingplate wired tempered and laminated glassIdeal for 24-hours loop protectionTwo wire sensor drawing no power from the loopCompatible with most wireless transmitters GBP 13.24 1
Ziton Flush Mount Call Point 560ohm with Glass and LED DMN700L Please note This item is being phased out we have limited stockavailable.Ziton Flush Mount Call Point 560ohm with Glass and LED DMN700LInstallation efficiency flexibility and full compliance with the latest standards are at the heart of the new MCP indoor call point range.InstallationInstallation time and ultimately cost are of paramount importance. The MCP range directly reflects this need by providing a unique plug and play concept designed specifically to reduce installation time. All new MCP products utilise a special terminal block where all initial installation cabling is terminated. This terminal block is then simply connected to the back of the MCP. Simple but effective with no re-termination required and no time wasted.Options and approvalsThrough new standards and legislation both break glass and re-settable operating elements may now be used. To provide the greatest flex-ability the new MCP range can be configured as either a break glass or re-settable unit by simply changing from one element to another. No other additional parts or alternative products are required.Full compliance with the latest standards is essential and the new MCP indoor call point range is fully approved to the latest EN54-11 standardKey FeaturesEnhanced aestheticsEasy to install plug and playSurface mount optionsProtection hinged cover with Anti-Tamper facilityBackward compatibleKey test facilityMay be used with glass or resettable elementEasy to replace glassHigh quality micro switchFully approved to the latest standards GBP 12.97 1