Kidde Airsense EST-XAUDIO-48-RS Function Card 4 IN 8 OUT Audio RS485 Kidde Airsense EST-XAUDIO-48-RS Function Card 4 IN 8 OUT Audio RS485This audio intputoutput card is designed for use with a ESTCU-8LCD function slot. It offers 4-line audio inputs via an RJ45 connector as well as 8 symmetrical outputs via an RJ45 connector for leading out audio signals to the external devices or amplifiers of the EST ENT VES system. The card is also equipped with an RS485 interface with the help of which the EST ENT VES system can be controlled or integrated with devices offered by other producers.Key FeaturesCurrent consumption typically 100 mA at 48 VOperating temperature 0C to 70CStandards EN54-16RS485 interface GBP 673.73 1
Gent VIG-NC-SMF Fibre Optic Network Card for VIG1-24 and VIG1-72 Vigilon Panels Gent VIG-NC-SMF Fibre Optic Network Card for VIG1-24 and VIG1-72 Vigilon PanelsThe Single Mode Fibre Network Card VIG-NC-SMF allows a fast and reliable network over distances of up to 20km between Vigilon Plus Panels VIGPLUS-24 VIGPLUS-72 Network Nodes VIGPLUS-NODE.The Single Mode Fibre Network card is designed to plug into the backplane of a panel or node in dedicated slots.Key FeaturesFibre optic connects directly to the sockets on the card.Up to 31 panelsnodes on a single network.Up to 200 panelsnodes on a complex networkEN54 V3 Single-Mode FibreConnection is by means of the ST sockets on the SM Fibre Network card.100g weight approximateOperating Temperature 0C to 45CStorage Temperature -10C to 55C GBP 843.34 1
Patol LHDC 1 Meter Commissioning amp Maintenance Test Oven Patol LHDC 1 Meter Commissioning Maintenance Test OvenCommissioning and routine maintenance testing of the Patol Analogue Linear Heat Detection Cable systems can be conducted at site using a calibrated 1 metre test oven.The portable 1 metre test oven concept of testing allows accessible one metre installed lengths of sensor cable to be subjected to temperatures within the alarm range. Thus confirming correct calibration setting selection and alarm levels in accordance with project specification requirements.Where sensor cable is installed within hazardous classified areas or may be inaccessible for oven use an additional one metre length may be series wired with existing cable sensor andor interconnecting cables to allow testing to be carried out local to the electronic interface unit in the safe area. Without adversely affecting system performance levels.Key FeaturesDimensions 1070 x 150 x 130mmWeight 13.55kgOperating Voltage 230115V ac fuse rated 10ATemperature Range 0C to 200CMaterial Rugged Aluminium GBP 5196.24 1
Notifier Honeywell ABT-EKB-20M Microphone Keyboard Extension Notifier Honeywell ABT-EKB-20M Microphone Keyboard ExtensionThe ABT-EKB-20M is compatible with all ambient microphones designed with a view to a possibility of its versatile application it is extremely suitable for both decentralized and centralized systems. The architecture of this system is based on fibre optic Ethernet connections between control units and other elements of the system which allows for its application in structures most extensive in terms of area and functionality such as air terminals oil fields and refineries commercial centers and office complexes. The system fully complies with a European mandatory standard EN54-16.DetailsPower supply RJ45 from DFMS or DMSDegree of protection IP 31Number of keys 20Number of LED 20x RGB 20x greenLED colour RGB red green blue separate LED greenOperating temperature 0C to 60CStorage temperature -20C to 70COperating humidity 15 to 80Storage humidity 5 to 95Weight 14 kgDimensions of the space for the description of the buttons 15x25 mm GBP 897.54 1
Kidde Airsense Air Heat Box 9-30422 Kidde Airsense Air Heat Box 9-30422The Stratos range of High Sensitivity Aspirating Smoke Detectors are suitable for installation within an area only if the ambient temperature is expected to be above 0C the minimum operating temperature of a Stratos detector is typically -10C check the specification of the particular detector in question. Where the air temperature in the protected area is consistently below this temperature it is imperative that the detector is mounted outside the protected area in an environment where the temperature meets that specified for the detector.However the sampled air from the protected area must be conditioned before it is passed into the detector. The Air Heater Box is designed to raise the temperature of the air drawn from a very cold environment by passing it across a heating element before it passes into the detector. In this manner the problem of condensation on sampling pipework external to the protected area is minimised. Warming the air sample will also ensure the components of the detector operate within the specified temperature tolerances and it reduces the possibility of surface condensation. GBP 1192.28 1
Zeta SP-REP Simplicity Plus Addressable Full Function Repeater Zeta SP-REP Simplicity Plus Addressable Full Function RepeaterThe Simplicity Plus is the ideal introduction to the world of addressable fire alarm panels.As its name suggests it has been designed with ease of use in mind using pre-programmed values for its programming options. The installer simply needs to configure the loop and enter text labels via the built in keypad optional.The Simplicity Plus has user definable zones option for zonal or common alarm operation options for IO operation alarm verification and user selectable languages.The SP-REP can be connected to all Simplicity Plus panels.Key FeaturesCertified to EN54 parts 2 4User definable zonesOption for zonal or common alarm operationOptions for IO operationAlarm verification help prevent false alarmsUser selectable languagesSet of changeover relay contacts for fault conditionSet of changeover relay contacts for fire condition2048 event log fire faultZone or device disablementOne man test modePlug play no need for any special tools or laptop for commissioningFully integrated keypadAll associated devices are loop poweredFull Fire Information and silence relaySupply Voltage 24V DCSystem Voltage 19 to 30V DCOperating Temp -0C to 50CEnclosure Size 375W x 335H x 75D GBP 515.45 1
Zeta SP-126M Simplicity Plus 126 Addressable Fire Alarm Panel - 1 Loop 126 Devices Zeta SP-126M Simplicity Plus 126 Analogue Addressable Fire Alarm Panel - 1 Loop 126 DevicesMetal EnclosureThe Simplicity Plus is the ideal introduction to the world of addressable fire alarm panels.As its name suggests it has been designed with ease of use in mind using pre-programmed values for its programming options. The installer simply needs to configure the loop and enter text labels via the built-in keypad optional.The Simplicity Plus has user definable zones option for zonal or common alarm operation options for IO operation alarm verification and user selectable languages.It can be connected to an RS232 desktop printer for real time event log printing Epson LQ300 recommended and it can also drive a serial repeater model SPREP Part No. 37-179.Alarm VerificationTo help prevent false alarm causing a full evacuation any smoke detector can be set to alarm verification mode with a time delay of between 30 seconds and 4 minutes. Should any of these detectors go into alarm then only the detectors LEDs and soundflasher base if connected will activate. Should the alarm not be cleared with this time delay then a common alarm will occur.Zonal AddressingAll devices are assigned to a specific zone based on their address. This removes a programming step and helps to streamline the commissioning process.Key Features1 Loop 126 DevicesCertified to EN54 parts 2 4User definable zonesOption for zonal or common alarm operationOptions for IO operationAlarm verification help prevent false alarmsUser selectable languagesSet of changeover relay contacts for fault conditionSet of changeover relay contacts for fire condition2048 event log fire faultZone or device disablementOne-man test modePlug play no need for any special tools or laptop for commissioningFully integrated keypadAll associated devices are loop poweredSupply Voltage 230V AC - 10System Voltage 24V DC NominalOperating Temperature -0C to 50CEnclosure Size 375mm x 335mm x 125mm GBP 725.08 1
STI STI-1229HTR240 Weather Strobe Dome Stopper Heated - 240V STI STI-1229HTR240 Weather Strobe Dome Stopper Heated - 240VNEMA 4X heated environmental enclosures for signalling appliance unit UL cUL listed. The Environmental Enclosures for Strobes are an excellent way to protect your signalling device located where temperature or environmental conditions exceed the suggested operation range. This protective cover with heater assembly for strobe appliances is ULcULULC Listed to NEMA 4X standards. Thermostatically controlled heaters and a continuous duty fan maintain a uniform temperature in the cover when located in a cold environment. Applications include but are not limited to refrigerators freezers meat packaging plants arctic environments ocean rigs etc. ULULC Listed down to -57C -70F applicable for indoor and outdoor.PLEASE NOTEThe enclosure is used to protect UL Listed 1638 and 1971 visual notification appliances at temperatures down to -57C -70F. It is the installers responsibility to comply with NFPA 72 NEC and other applicable fire and electrical codes. Conduit or raceway paths need to be sealed as near to the enclosure as possible. Installer should have maintained supervision over the low temperature thermostat. The low temperate monitoring thermostat makes the circuit at 0C 32F and clears the circuit at 10C 50F. This listing requires that the fire alarm supervisory control module be only of the latching type. The heater assembly and gasket have a life of 5 years. After such date a replacement heater assembly can be purchased STI-HK2A. There is a label on the heater assembly to record the installation date. In hazardous areas all sources of power must be shutdown before accessing cover per NEC.Details Protective cover for strobe only 240 VAC heated enclosure Type 4X Enclosed back box 3 year guarantee 1 yr on electronics Please note Due to the curvature of this model the depth stated will vary 184 mm H x 184 mm W x 73 mm D GBP 957.26 1