Fireray 5000 Auto-Aligning Optical Beam Smoke Detector 50m Fireray 5000 Auto-Aligning Optical Beam Smoke Detector 50mThe FIRERAY 5000 motorised auto aligning infrared optical beam smoke detector can now be installed with up to two detector heads per system thus saving on installation time and costs.This innovative system has been designed from the ground up to include pioneering technology that fully addresses the needs of the installer and user both now and in the future.Key BenefitsUp to 2 optical beam detectors per system controllerEasifit Fix SystemGround Level ControlLaser Assisted AlignmentAuto-Optimise Beam AlignmentContamination CompensationBuilding Shift CompensationApproved to EN5412 and UL268 GBP 1191.90 1
Fireray 5000 Single Detector Pack 100m Fireray 5000 Single Detector Pack 100mThe FIRERAY 5000 motorised auto aligning infrared optical beam smoke detector can now be installed with up to four detector heads per system thus saving on installation time and costs.This innovative system has been designed from the ground up to include pioneering technology that fully addresses the needs of the installer and user both now and in the future.Key BenefitsUp to 2 optical beam detectors per system controllerEasifit Fix SystemGround Level ControlLaser Assisted AlignmentAuto-Optimise Beam AlignmentContamination CompensationBuilding Shift CompensationApproved to EN5412 and UL268 GBP 1078.80 1
Fireray 5000 Single Detector Pack 50m Fireray 5000 Single Detector Pack 50mThe FIRERAY 5000 motorised auto aligning infrared optical beam smoke detector can now be installed with up to four detector heads per system thus saving on installation time and costs.This innovative system has been designed from the ground up to include pioneering technology that fully addresses the needs of the installer and user both now and in the future.Key BenefitsUp to 2 optical beam detectors per system controllerEasifit Fix SystemGround Level ControlLaser Assisted AlignmentAuto-Optimise Beam AlignmentContamination CompensationBuilding Shift CompensationApproved to EN5412 and UL268 GBP 948.30 1
Fireray 5000 Auto-Aligning Optical Beam Smoke Detector 100m Fireray 5000 Auto-Aligning Optical Beam Smoke Detector 100mThe FIRERAY 5000 motorised auto aligning infrared optical beam smoke detector can now be installed with up to two detector heads per system thus saving on installation time and costs.This innovative system has been designed from the ground up to include pioneering technology that fully addresses the needs of the installer and user both now and in the future.Key BenefitsUp to 2 optical beam detectors per system controllerEasifit Fix SystemGround Level ControlLaser Assisted AlignmentAuto-Optimise Beam AlignmentContamination CompensationBuilding Shift CompensationApproved to EN5412 and UL268 GBP 1313.70 1
Fireray 3000 Transmitter amp Receiver Fireray 3000 Transmitter ReceiverThe FIRERAY 3000 End to End Infrared Optical Beam Smoke Detector OBSD has been designed using the latest optical technology incorporating modern industrial electronics and software techniques. This detector offers cost effective protection of large open area spaces with high ceilings. It is also very suited to applications where access to ceiling mounted smoke detectors presents practical difficulties.Key BenefitsSeparate Transmitter and Receiver HeadsRange 5 to 120 metres configurable per set of DetectorsIntegral Laser Alignment in Receiver2-wire Interface between Controller and ReceiverSingle and Twin Detector optionsSeparate Fire and Fault Relays per DetectorLow Level Controller with LCD displayProgrammable Sensitivity and Fire ThresholdAutomatic Gain Control AGC for drift compensationFirst Fix concept for Transmitter Receiver and ControllerMultiple cable gland knockouts for ease of wiringOptional Transmitter powering from Controller5-year Warranty GBP 1113.60 1
Fireray 3000 End to End Infrared Optical Beam Detector Fireray 3000 End to End Infrared Optical Beam DetectorThe FIRERAY 3000 End to End Infrared Optical Beam Smoke Detector OBSD has been designed using the latest optical technology incorporating modern industrial electronics and software techniques.This detector offers cost effective protection of large open area spaces with high ceilings. It is also very suited to applications where access to ceiling mounted smoke detectors presents practical difficulties.Key BenefitsSeparate Transmitter and Receiver HeadsRange 5 to 120 metres configurable per set of DetectorsIntegral Laser Alignment in Receiver2-wire Interface between Controller and ReceiverSingle and Twin Detector optionsSeparate Fire and Fault Relays per DetectorLow Level Controller with LCD displayProgrammable Sensitivity and Fire ThresholdAutomatic Gain Control AGC for drift compensationFirst Fix concept for Transmitter Receiver and ControllerMultiple cable gland knockouts for ease of wiringOptional Transmitter powering from Controller5-year Warranty GBP 1392.00 1
Morley MA-LCD7 Max 7quot Touchscreen RepeaterZonal Mimic Morley MA-LCD7 Max 7 Touchscreen RepeaterZonal MimicThe MA-LCD7 is compact with a sleek low profile modern design which incorporates a 7 TFT 256 colour touchscreen display. Utilising Morley-IAS Maxs intuitive tabs and navigational user interface UI. The MA-LCD7 includes a unique colour coding system to increase users situational awareness of events and alarms.Key FeaturesSingle hardware with dual functionality programmable as a Repeater or a MimicFull network visibility and control Reset SilenceResound and Mute BuzzerUSB port for firmware upgrades and event history retrievalModern compact designUp to 16 Repeaters per pane80 zones Mimic on a single repeater up to 1120 zones at maximum configurationMorley-IAS Max unique User Interface for improved situational awarenessIncludes Easy Fix Plate for fast installationFits most standard single or double electrical backboxes. Suitable for surface mountDownload network event history via a USB memory drive GBP 532.21 1
Cranford Controls WTA-KIT Toilet Alarm Kit Transmitter amp Receiver Cranford Controls WTA-KIT Toilet Alarm Kit Transmitter ReceiverThe wireless toilet alarm is designed to meet the needs of the Disability Discrimination Act DDA in all public buildings and to provide a fully featured system at an economical cost. The installation of this type of system is very simple requiring only two screws to fix each unit in its required place. The basic system comprises a ceiling mounted pull cord unit with a reassurance LED and an over-door sounderlight unit. Both units run on self-contained battery power with a long life battery and automatic battery monitoring.Key FeaturesFully programmable ISs in both units for multiple onsite installationsComplies with EN 300 220-3 and EN 301 489-3Battery life minimum of 1 year with low battery warning built inMaximum range 30-50 metres internally 100-150 externally65dBa measured at one metrePull cord once for alert and twice to reset the unit GBP 519.08 1
Notifier PRL-LED-EN Pearl Fixed 2 Loop Intelligent Fire Alarm Control Panel with 64 LEDs Notifier PRL-LED-EN Pearl Fixed 2 Loop Intelligent Fire Alarm Control Panel with 64 LEDsThe Pearl fire alarm control panel from Notifier by Honeywell is a robust and easy to use networkable 1 or 2 loop panel. It exploits Notifiers class leading Opal digital protocol to maximise the speed and efficiency of fire detection and alarm. The large display with its intuitive interface and menu driven features allows quick and easy operation of the system.Coupled with more power and devices on the loop than other panels in its class the simple design will allow for trouble-free first fix installation. Compatible with the ID2net network used by the ID3000 the Pearl panel is supported by an integrated tools suite to enhance and simplify the system management.Extended capacityThe Pearl supports up to 636 loop devices 159 detectors plus 159 modules per loopLonger loops but fewer of them will give the opportunity to save on installation time cost and wiringHighly resilient Opal system able to pinpoint a loop fault whilst maintaining full system operationPowerful networking capability - Up to 16 Pearl panels controlling over 10000 devices can be networked via the superfast ID2net prioritising a fire signal to communicate across a network in under three secondsEase of useIntuitive on-site management - backlit buttons for fast error free situation management and large display giving complete information at a glanceSimpler diagnostics and maintenance - panel control of detector LEDs enabling confirmation of detector statusText programming via MS Excel spread sheetUser permissions set per individual passwordFlexibilityUnique first fix bracket with adaptations for 19 rack or flush mounting.Fast system set up and commissioning via the panel loop Autolearn and advanced PC tools suiteComprehensive Cause Effect programming capabilityPanel sounder and beacon synchronisationSystem extensions and adaptations can be made quickly without compromising fire cover and without extensive re-cablingSeparate text change without risk to Cause Effect or system configuration.Ability to run BS5839 part 6 system for HMO GBP 2044.22 1
Notifier PRL-LED-EN-1 Pearl Fixed 1 Loop Intelligent Fire Alarm Control Panel with 64 LEDs Notifier PRL-LED-EN-1 Pearl Fixed 1 Loop Intelligent Fire Alarm Control Panel with 64 LEDsThe Pearl fire alarm control panel from Notifier by Honeywell is a robust and easy to use networkable 1 or 2 loop panel. It exploits Notifiers class leading Opal digital protocol to maximise the speed and efficiency of fire detection and alarm. The large display with its intuitive interface and menu driven features allows quick and easy operation of the system.Coupled with more power and devices on the loop than other panels in its class the simple design will allow for trouble-free first fix installation. Compatible with the ID2net network used by the ID3000 the Pearl panel is supported by an integrated tools suite to enhance and simplify the system management.Extended capacityThe Pearl supports up to 636 loop devices 159 detectors plus 159 modules per loopLonger loops but fewer of them will give the opportunity to save on installation time cost and wiringHighly resilient Opal system able to pinpoint a loop fault whilst maintaining full system operationPowerful networking capability - Up to 16 Pearl panels controlling over 10000 devices can be networked via the superfast ID2net prioritising a fire signal to communicate across a network in under three secondsEase of useIntuitive on-site management - backlit buttons for fast error free situation management and large display giving complete information at a glanceSimpler diagnostics and maintenance - panel control of detector LEDs enabling confirmation of detector statusText programming via MS Excel spread sheetUser permissions set per individual passwordFlexibilityUnique first fix bracket with adaptations for 19 rack or flush mounting.Fast system set up and commissioning via the panel loop Autolearn and advanced PC tools suiteComprehensive Cause Effect programming capabilityPanel sounder and beacon synchronisationSystem extensions and adaptations can be made quickly without compromising fire cover and without extensive re-cablingSeparate text change without risk to Cause Effect or system configuration.Ability to run BS5839 part 6 system for HMO GBP 1619.16 1
Fireray 3000-007 Fireray 3000 Controller Fireray 3000-007 Fireray 3000 ControllerThe Fireray 3000 is ideal for applications where line of sight for the IR infra-red detection path is narrow and where the building structure uses reflective surfaces. It has also been designed to be aesthetically pleasing and thus can equally suit modern architectural buildings as well as heritage sites particularly where ornate ceilings exist.The Fireray 3000 optical beam smoke detectors together with a battery backed power supply can be connected to a zone of a conventional fire alarm control panel or interfaced to an analogue-addressable system via an addressable input module.The Fireray 3000 has been designed so that it can be installed by one operator with its laser assisted alignment methods combined with easy-to-use alignment LEDs offering a visual feedback. Integrated laser alignment aid can be activated at the controller or at the Receiver head.Key FeaturesAllows for 2 Detectors per System ControllerRange 5 to 120 metres configurable per set of DetectorsIntegral Laser Alignment in Receiver2-wire Interface between Controller and ReceiverSeparate Fire and Fault Relays per DetectorLow Level Controller with LCD displayProgrammable Sensitivity and FireFault delayAutomatic Gain Control AGC for drift compensationFirst Fix concept for Transmitter Receiver and ControllerMultiple cable gland knockouts for ease of wiringTransmitter can be powered from ControllerPatented Light Cancellation Technology LCT cancels unwanted light including sunlight sodium lamps and fluorescent lighting GBP 1044.00 1
Kidde Airsense Micra 10 Single Pipe Aspiration Smoke Detector 9-30725 Kidde Airsense Micra 10 Single Pipe Aspiration Smoke Detector 9-30725The AirSense Micra 10 is designed to provide very high sensitivity smoke detection in a small package. ClassiFire Perceptive Artificial Intelligence ensures that the detector operates at optimum sensitivity for the protected environment without the need for complex setup. This means the product will configure itself to provide high sensitivity in a computer room or reduced sensitivity in a smoky area.The detector is designed to fit into a Docking Station. All sampling pipes and cables are connected to the Docking Station as a first fix operation leaving the detector to be fitted during the final commissioning phase if required. This ensures that detectors are less likely to be damaged during the installation. Upgradable volt-free Fire and Fault relay outputs are available for remote monitoring by local fire detection or BMS systems.ApplicationsData storage unitsPrison cellsPlant roomsAir conditioning unitsEquipment racksComputer roomsAir duct protectionHeritage property protectionCritical equipmentAnti-smoking enforcementMotor roomsKey FeaturesUltra-small low-cost aspirating smoke detector for easy and discreet installationHigh sensitivity provided by laser based forward light scatter for reliable early warningSingle sampling pipe up to 50m in length still airUnique ClassiFire Perceptive Artificial Intelligence system that dynamically adjusts the detectors operating parameters allowing for day to day changes in the protected environment and dust separation system contaminationUnwanted alarms from dust are avoided using patented Dual Technology LDD 3D3 Laser Dust Discrimination and elimination system GBP 888.07 1
Fireclass 508.033.751FC Prescient III Extinguishing Control Panel Fireclass 508.033.751FC Prescient III Extinguishing Control PanelThe Prescient III gaseous extinguishant control panel is powerful yet user-friendly and is designed and manufactured to a high standard. The panel features approval to BSEN 12094-12003 BSEN 54-2 and 4 and is designed to BS7273 part 1.The panel has extensive configuration options but is easy to install programme and operate. The removable chassis enables the engineer to first fix an empty cabinet and then fit the chassis at the commissioning stage. This is supported by comprehensive documentation on commissioning operating maintenance and fault finding. In addition there is a comprehensive range of compatible accessories available to meet most customer requirements.Key FeaturesComprehensive facilities for gaseous extinguishing systemsApproval to BSEN 12094-12003 additional optionsApproval to BSEN 54-2 and 4Designed to BS7273-12000Monitored inputs for gas discharged gas low isolation valve closedabnormal gas trapped in manifoldControl inputs for automanual gas hold gas abort1 minute actuator cut off optionMonitored actuatorsolenoid releaseExtensive disablement optionsCommon fire fault relay monitored output facilities1st stage 2nd stage 3rd stage and gas discharged relay monitored output facilitiesReset relay facilitiesIntrinsically safe barrier settingsMetron or solenoid compatibleSingle or double knock operationPre-discharge delay adjustable from 0 to 60 secondsDischarged indication with or without pressure switchInhibit silence alarms until gas dischargedLatching or non latching fault indication optionOption for rapid buzzer pulse when gas imminentSemi-flush bezel and fully-flush cabinet options availableOne man zone and sounder testEasily removable chassis GBP 671.05 1
Advanced Touch Screen Terminal Touch-10 Advanced Touch Screen Terminal Touch-10TouchControl is a 10 high-resolution touch screen Remote Control Terminal with active maps and zone plans. It is a fire panel and network node in its own right and works on Advanceds standard and fault tolerant networks. It is compatible with our MxPro and Axis EN fire panels. Zone information is presented via the units colour coded easy-to-navigate interface and the active maps that are easily configured using the Dynamix Tools Map App. Using TouchControls colour-coded easy-to-navigate interface users canEvacuateMuteSilenceResound ResetView fires faults disablementsalarms inputs outputs supervisory and network via instant filtersViewenabledisable zonesViewenabledisable devicesEnabledisable outputs by typeEnable Walk Test modeTest displayzonesoutputsbuzzer and LEDsQuickly access all zones in firefaultdisablementtest via instant filters and where allowed change statusView 1000 general and 500 Fire event logSet network time and dateUsers can choose from five pre-set background images or upload their own. The relevant zone plan to the units position can be displayed and users can run presentations on the display which defaults to normal operation in the event of a fire condition or if the screen is touched. TouchControl enhances public areas and provides new levels of control and oversight.Key Features2 Part enclosure for easy first fix and slide-in installation.10high resolution screen designed to work with firemans glove At a glance system status immediately identify zones and devices in Fire Test Supervisory and FaultInteractive site maps and zone plans capability built-inMonitored external input for external PSU faultsTwo-core connection to the network fault tolerant or standardLow-profile bezel for flush fittingSelect from a number of background images or add a customised imageLow profile installationDedicated status indicators for Fire Fault System Fault Disabled Test and PowerZone plan display an essential part of BS5839-1Dual Power Supply inputs independently monitored to allow redundant power feeds GBP 2147.28 1
Kidde 9-30780-KID Kidde Senator Modulaser Minimum Display Module Kidde 9-30780-KID Kidde Senator Modulaser Minimum Display ModuleModuLaser is a scalable aspirating smoke detection solution thatmakes installation easier maintenance quicker and takes applicationsfurther than traditional air sampling detectors. Two basic module typescomprise the ModuLaser solution a display module and a detectormodule. Each detector module can accommodate up to 250 meterscombined sampling pipe. Display modules and detector modulescommunicate by RS-485 interconnections.Display modules are available in three configurations Standard withTFT colour display status LEDs and navigation buttons Minimum withonly status LEDs and Command which is similar to the Standard butwith the added functionality to control various modules overSenseNET. The Minimum and Standard Display Modules can eachsupport up to 8 detector modules while the Command Display Modulecan support up to 127 modules across the SenseNET network.Key FeaturesModular Design Separate centrally-controllable detector modules allow efficient piping and discrete zones with no overlap.Zoned aspirating smoke detection Individual detector modules provide detection for individual areas or zones specific zone alarm information can be transmitted to the main fire alarm panel via a common APIC address card in the display module or through dedicated alarm relays within each detector module.Simplified installation Ingenious docking station design allows detectors to be easily connected together as a group. Sensitive electronics are easily removed to ensure they will not be damaged during first fix installation. Aspirating pipework and cable entries can easily be made into either the top or the bottom of the unit.Intuitive user interface Bright easy-to-see color TFT display and universal navigation and control buttons take the guesswork out of programming and diagnostics.Easy pipe connection The quick fit pipe adaptor system locks down securely yet leaves plenty of room for easy pipe connection and removal.Quick location of smoke Each detector module is self-contained which means no delays in determining in which zone sampling pipe smoke is present. GBP 487.51 1
Advanced Touch Screen Terminal Fault Tolerant Network Touch-10FT Advanced Touch Screen Terminal Fault Tolerant Network Touch-10FTTouchControl is a 10 high-resolution touch screen Remote Control Terminal with active maps and zone plans. It is a fire panel and network node in its own right and works on Advanceds standard and fault tolerant networks. It is compatible with our MxPro and Axis EN fire panels. Zone information is presented via the units colour coded easy-to-navigate interface and the active maps that are easily configured using the Dynamix Tools Map App. Using TouchControls colour-coded easy-to-navigate interface users canEvacuateMuteSilenceResound ResetView fires faults disablementsalarms inputs outputs supervisory and network via instant filtersViewenabledisable zonesViewenabledisable devicesEnabledisable outputs by typeEnable Walk Test modeTest displayzonesoutputsbuzzer and LEDsQuickly access all zones in firefaultdisablementtest via instant filters and where allowed change statusView 1000 general and 500 Fire event logSet network time and dateUsers can choose from five pre-set background images or upload their own. The relevant zone plan to the units position can be displayed and users can run presentations on the display which defaults to normal operation in the event of a fire condition or if the screen is touched. TouchControl enhances public areas and provides new levels of control and oversight.Key Features2 Part enclosure for easy first fix and slide-in installation.10high resolution screen designed to work with firemans glove At a glance system status immediately identify zones and devices in Fire Test Supervisory and FaultInteractive site maps and zone plans capability built-inMonitored external input for external PSU faultsTwo-core connection to the network fault tolerant or standardLow-profile bezel for flush fittingSelect from a number of background images or add a customised imageLow profile installationDedicated status indicators for Fire Fault System Fault Disabled Test and PowerZone plan display an essential part of BS5839-1Dual Power Supply inputs independently monitored to allow redundant power feeds GBP 2708.26 1
Ziton FD310H - Additional Detector Pair 5 - 120m for FD310 ZitonFD310H - Additional Detector Pair 5 - 120m for FD310The FD310 End to End infrared Optical Beam Smoke Detector OBSD has been designed using the latest optical technology incorporating modern industrial electronic and software techniques. This detector offers cost effective protection of large open area spaces with high ceilings. It is also very suited to applications where access to ceiling mounted smoke detectors presents practical difficulties.OperationThe system comprises a modern looking Transmitter head which emits a narrow beam of infra-red light to an associated Receiver head with a compact Low Level Controller. Once smoke crosses through and thus obscures the IR beam path the signal strength at the Receiver drops below a preset level which in turn results in an alarm condition. Both the detector heads Transmitter and Receiver have integrated alignment thumbwheels for ease of alignment. Using these thumbwheels provides a smooth and repeatable alignment process. The detector heads have up to 10 degrees of adjustment in both planes. For further adjustment a bespoke Adjustment Bracket is available which offers up to 180 degrees movement in both planes as well as a full 360-degree rotation.The FD310 has been designed so that it can be installed by one operator with its laser assisted alignment method combined with easy to use alignment LEDs offering a visual feedback. Integrated laser alignment aid can be activated at the Controller or at the Receiver head.The low level Controller incorporates a LCD display which offers a full icon-based easy-to-use interface unit. This Controller enables ease of commissioning testing and maintenance of the beam detection system. During commissioning the detector sensitivity and fire thresholds can be selected along with the user variable time to fire and time to fault settings.Key FeaturesSeparate Transmitter and Receiver HeadsRange 5 to 120 metres configurable per set of DetectorsIntegral Laser Alignment in Receiver2-wire Interface between Controller and ReceiverSingle and Twin Detector optionsSeparate Fire and Fault Relays per DetectorLow Level Controller with LCD displayProgrammable Sensitivity and Fire ThresholdAutomatic Gain Control AGC for drift compensationFirst Fix concept for Transmitter Receiver and ControllerMultiple cable gland knockouts for ease of wiringOptional Transmitter powering from Controller GBP 789.20 1
Kidde AirSense Stratos ModuLaser Detector Module 9-30783 Kidde AirSense Stratos ModuLaser Detector Module 9-30783ModuLaser is a scalable aspirating smoke detection solution that makes installation easier maintenance quicker and takes applications further than traditional air sampling detectors. Two basic module types comprise the ModuLaser solution a display module and a detector module. Each detector module can accommodate up to 250 meters combined sampling pipe. Display modules and detector modules communicate by RS-485 interconnections.Display modules are available in three configurations Standard with TFT colour display status LEDs and navigation buttons Minimum with only status LEDs and Command which is similar to the Standard but with the added functionality to control various modules over SenseNET. The Minimum and Standard Display Modules can each support up to 8 detector modules while the Command Display Module can support up to 127 modules across the SenetNET network.Thanks to advanced features that make it virtually impervious to dust and dirt ModuLaser is ideal for use in hostile environments that would disable other kinds of smoke detectors. Forward scattering optical detection adds early warning capability without the risk of nuisance alarms normally associated with high sensitivity smoke detection while exclusive environmental compensation technology adds a high degree of reliability to an already solid detection solution.Key FeaturesModular Design Separate centrally-controllable detector modules allow efficient piping and discrete zones with no overlap.Zoned aspirating smoke detection Individual detector modules provide detection for individual areas or zones specific zone alarm information can be transmitted to the main fire alarm panel via a common APIC address card in the display module or through dedicated alarm relays within each detector module.Simplified installation Ingenious docking station design allows detectors to be easily connected together as a group. Sensitive electronics are easily removed to ensure they will not be damaged during first fix installation. Aspirating pipework and cable entries can easily be made into either the top or the bottom of the unit.Intuitive user interface Bright easy-to-see colour TFT display and universal navigation and control buttons take the guesswork out of programming and diagnostics.Easy pipe connection The quick fit pipe adaptor system locks down securely yet leaves plenty of room for easy pipe connection and removal.Quick location of smoke Each detector module is self-contained which means no delays in determining in which zone sampling pipe smoke is present. GBP 856.82 1
Kidde AirSense Stratos ModuLaser Minimum Display Module 9-30780 Kidde AirSense Stratos ModuLaser Minimum Display Module 9-30780ModuLaser is a scalable aspirating smoke detection solution that makes installation easier maintenance quicker and takes applications further than traditional air sampling detectors. Two basic module types comprise the ModuLaser solution a display module and a detector module. Each detector module can accommodate up to 250 meters combined sampling pipe. Display modules and detector modules communicate by RS-485 interconnections.Display modules are available in three configurations Standard with TFT colour display status LEDs and navigation buttons Minimum with only status LEDs and Command which is similar to the Standard but with the added functionality to control various modules over SenseNET. The Minimum and Standard Display Modules can each support up to 8 detector modules while the Command Display Module can support up to 127 modules across the SenetNET network.Thanks to advanced features that make it virtually impervious to dust and dirt ModuLaser is ideal for use in hostile environments that would disable other kinds of smoke detectors. Forward scattering optical detection adds early warning capability without the risk of nuisance alarms normally associated with high sensitivity smoke detection while exclusive environmental compensation technology adds a high degree of reliability to an already solid detection solution.Key FeaturesModular Design Separate centrally-controllable detector modules allow efficient piping and discrete zones with no overlap.Zoned aspirating smoke detection Individual detector modules provide detection for individual areas or zones specific zone alarm information can be transmitted to the main fire alarm panel via a common APIC address card in the display module or through dedicated alarm relays within each detector module.Simplified installation Ingenious docking station design allows detectors to be easily connected together as a group. Sensitive electronics are easily removed to ensure they will not be damaged during first fix installation. Aspirating pipework and cable entries can easily be made into either the top or the bottom of the unit.Intuitive user interface Bright easy-to-see colour TFT display and universal navigation and control buttons take the guesswork out of programming and diagnostics.Easy pipe connection The quick fit pipe adaptor system locks down securely yet leaves plenty of room for easy pipe connection and removal.Quick location of smoke Each detector module is self-contained which means no delays in determining in which zone sampling pipe smoke is present. GBP 948.44 1
Ziton FD310 End-to-End Beam Detector 5 to 120m Ziton FD310 End-to-End Beam Detector 5 to 120mOptical beam smoke detector consists of separate transmitter and receiver heads and a low level controller.The FD310 End to End infrared Optical Beam Smoke Detector OBSD has been designed using the latest optical technology incorporating modern industrial electronic and software techniques. This detector offers cost effective protection of large open area spaces with high ceilings. It is also very suited to applications where access to ceiling mounted smoke detectors presents practical difficulties.The system comprises a modern looking Transmitter head which emits a narrow beam of infra-red light to an associated Receiver head with a compact Low Level Controller. Once smoke crosses through and thus obscures the IR beam path the signal strength at the Receiver drops below a pre-set level which in turn results in an alarm condition. Both the detector heads Transmitter and Receiver have integrated alignment thumbwheels for ease of alignment. Using these thumbwheels provides a smooth and repeatable alignment process. The detector heads have up to 10 degrees of adjustment in both planes. For further adjustment a bespoke Adjustment Bracket is available which offers up to 180 degrees movement in both planes as well as a full 360-degree rotation.The FD310 has been designed so that it can be installed by one operator with its laser assisted alignment method combined with easy to use alignment LEDs offering a visual feedback. Integrated laser alignment aid can be activated at the Controller or at the Receiver head.The low level Controller incorporates a LCD display which offers a full icon-based easy-to-use interface unit. This Controller enables ease of commissioning testing and maintenance of the beam detection system. During commissioning the detector sensitivity and fire thresholds can be selected along with the user variable time to fire and time to fault settings.Range 5 to 120m integral laser alignment controller can support 2 pairs of transmitter and receivers additional pairs are available FD310H.Key FeaturesSeparate Transmitter and Receiver HeadsRange 5 to 120 metres configurable per set of DetectorsIntegral Laser Alignment in Receiver2-wire Interface between Controller and ReceiverSingle and Twin Detector optionsSeparate Fire and Fault Relays per DetectorLow Level Controller with LCD displayProgrammable Sensitivity and Fire ThresholdAutomatic Gain Control AGC for drift compensationFirst Fix concept for Transmitter Receiver and ControllerMultiple cable gland knockouts for ease of wiringOptional Transmitter powering from ControllerSupply voltage 12-36VDCCurrent Controller 14mA per transmitter head 8mAFire and Fault relays per detector head - rated 2A 30VDCDetector head dimensions per transmitter and receiver unit mm 74w x 74h x 161dController dimensions mm 203w x 124h x 73d GBP 947.02 1
Kidde AirSense Stratos ModuLaser Standard Display Module 9-30781 Kidde AirSense Stratos ModuLaser Standard Display Module 9-30781ModuLaser is a scalable aspirating smoke detection solution that makes installation easier maintenance quicker and takes applications further than traditional air sampling detectors. Two basic module types comprise the ModuLaser solution a display module and a detector module. Each detector module can accommodate up to 250 meters combined sampling pipe. Display modules and detector modules communicate by RS-485 interconnections.Display modules are available in three configurations Standard with TFT colour display status LEDs and navigation buttons Minimum with only status LEDs and Command which is similar to the Standard but with the added functionality to control various modules over SenseNET. The Minimum and Standard Display Modules can each support up to 8 detector modules while the Command Display Module can support up to 127 modules across the SenetNET network.Thanks to advanced features that make it virtually impervious to dust and dirt ModuLaser is ideal for use in hostile environments that would disable other kinds of smoke detectors. Forward scattering optical detection adds early warning capability without the risk of nuisance alarms normally associated with high sensitivity smoke detection while exclusive environmental compensation technology adds a high degree of reliability to an already solid detection solution.The Standard Display Module features a user interface which consist of a TFT colour display navigation buttons and status LEDs. Configuration of the Standard Display Module and associated detectors modules can be done via the user interface via a computer using Remote software or via SenseNET using a Command Display Module. The TFT colour display support simple operations like changing configuration options via a menu driven structure but also advanced features like viewing the chart recording in graphical format.The Standard Display Module has two USB ports one master and one slave. The master is used to connect a pen drivememory stick which in turn can be used for storing the configuration the event logs or chart recordings or for firmware upgrade purposes. While the USB slave is used to connect to a computer.Key FeaturesModular Design Separate centrally-controllable detector modules allow efficient piping and discrete zones with no overlap.Zoned aspirating smoke detection Individual detector modules provide detection for individual areas or zones specific zone alarm information can be transmitted to the main fire alarm panel via a common APIC address card in the display module or through dedicated alarm relays within each detector module.Simplified installation Ingenious docking station design allows detectors to be easily connected together as a group. Sensitive electronics are easily removed to ensure they will not be damaged during first fix installation. Aspirating pipework and cable entries can easily be made into either the top or the bottom of the unit.Intuitive user interface Bright easy-to-see colour TFT display and universal navigation and control buttons take the guesswork out of programming and diagnostics.Easy pipe connection The quick fit pipe adaptor system locks down securely yet leaves plenty of room for easy pipe connection and removal.Quick location of smoke Each detector module is self-contained which means no delays in determining in which zone sampling pipe smoke is present. GBP 1066.99 1
Kidde AirSense Stratos ModuLaser Command Display Module 9-30782 Kidde AirSense Stratos ModuLaser Command Display Module 9-30782ModuLaser is a scalable aspirating smoke detection solution that makes installation easier maintenance quicker and takes applications further than traditional air sampling detectors. Two basic module types comprise the ModuLaser solution a display module and a detector module. Each detector module can accommodate up to 250 meters combined sampling pipe. Display modules and detector modules communicate by RS-485 interconnections.Display modules are available in three configurations Standard with TFT colour display status LEDs and navigation buttons Minimum with only status LEDs and Command which is similar to the Standard but with the added functionality to control various modules over SenseNET. The Minimum and Standard Display Modules can each support up to 8 detector modules while the Command Display Module can support up to 127 modules across the SenetNET network.Thanks to advanced features that make it virtually impervious to dust and dirt ModuLaser is ideal for use in hostile environments that would disable other kinds of smoke detectors. Forward scattering optical detection adds early warning capability without the risk of nuisance alarms normally associated with high sensitivity smoke detection while exclusive environmental compensation technology adds a high degree of reliability to an already solid detection solution.The Standard Display Module features a user interface which consist of a TFT colour display navigation buttons and status LEDs. Configuration of the Standard Display Module and associated detectors modules can be done via the user interface via a computer using Remote software or via SenseNET using a Command Display Module. The TFT colour display support simple operations like changing configuration options via a menu driven structure but also advanced features like viewing the chart recording in graphical format.The Standard Display Module has two USB ports one master and one slave. The master is used to connect a pen drivememory stick which in turn can be used for storing the configuration the event logs or chart recordings or for firmware upgrade purposes. While the USB slave is used to connect to a computer.Key FeaturesModular Design Separate centrally-controllable detector modules allow efficient piping and discrete zones with no overlap.Zoned aspirating smoke detection Individual detector modules provide detection for individual areas or zones specific zone alarm information can be transmitted to the main fire alarm panel via a common APIC address card in the display module or through dedicated alarm relays within each detector module.Simplified installation Ingenious docking station design allows detectors to be easily connected together as a group. Sensitive electronics are easily removed to ensure they will not be damaged during first fix installation. Aspirating pipework and cable entries can easily be made into either the top or the bottom of the unit.Intuitive user interface Bright easy-to-see colour TFT display and universal navigation and control buttons take the guesswork out of programming and diagnostics.Easy pipe connection The quick fit pipe adaptor system locks down securely yet leaves plenty of room for easy pipe connection and removal.Quick location of smoke Each detector module is self-contained which means no delays in determining in which zone sampling pipe smoke is present. GBP 1832.20 1