76 results (0,13452 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

Klaxon SLF-0008 Duty Hand Operated Siren 95cm

Aritech ATS1192X4 ATS Heavy Duty Smart Card Reader x 4

Aritech ATS1192X4 ATS Heavy Duty Smart Card Reader x 4

Aritech ATS1192X4 ATS Heavy Duty Smart Card Reader x 4The ATS1192 smart card reader connect directly on the RS485 data bus of the control panel or 4-Door Controller and may be configured and addressed via a LCD keypad. Some security options Site code 4-byte security code are only programmable via TITAN and configuration cards.The ATS1192 is mainly used for outdoor applications and due to the waterproof construction it is suitable for use in harsh environments.High quality cards key fobsBoth the smart chip and antenna are embedded inside the cards fobs. Printing is possible on the cards using any industry standard printer. The ATS1476 cards feature a programmable magnetic stripe for Time Attendance or other applications.Security featuresThe ATS smart card technology has the ability to program a unique 268 million 4-byte combination security code values from 0 through 127 are applicable for EMEA. This allows the memory card to unlockopendisarm based on three keys the card number the Site code and the 4-byte security code. Once a 4-byte security code has been created downloaded to the programmer and the cards it is not possible to read the memory on the card or even recognise the card memory at any other reader or TITAN and programmer combination. Communications between TITAN and the programmer may also be password protected to prevent the 4-byte security code from being uploaded from the programmer into another PC running TITAN.ReadWrite encryptionThe ATS Smart card technology also features an exclusive readwrite encryption. When a card is presented at a reader data are downloaded into the reader encrypted and re-written back into the card. The readers can also be configured to operate in stand-alone or connected to control devices like office equipment or vending machines. This function enables credits to be assigned on user cards and deducted by the readers purely on a usage basis. Up to 65535 credits may be allocated in up to 4 different banks with 16 access levels and 4 locations. The reader determines of which bank credits have to be deducted and the number of credits per valid presentation.Key FeaturesFull epoxy filled weather proof constructionHeavy-duty versionCompatible with Axon and Advisor Advanced panelsPack of 4

GBP 793.42
1

Scope RTESTPB Range Testing Kit For Pendant PEN4 Wave Track amp PB1BPB2B Panic Buttons With Transponder

STI EM362408WA Grey Metal Cabinet Window Door - 110V AH

STI EM362408WA Grey Metal Cabinet Window Door - 110V AH

STI EM362408WA Grey Metal Cabinet Window Door - 110V AHThis ACheated enclosure allows alarm control panels to be protected from extreme temperatures or other areas requiring UL Type 4 protection.The extra large super tough heavy-duty metal enclosure guards against vandalism either accidental or intentional as well as dirt dust and grime. Its size allows the enclosure to house significantly sized electronic devices with space to spare. This UL Type 4 enclosure mounts to the wall enabling the units to be protected in their designated location.Unlike competitive models this enclosure is available with a clear window allowing the unit within to be quickly identified. Both the enclosure and ACheater unit have a durable finish to help protect against corrosion. The enclosure has two turn latches to help prevent unauthorized entry.Key FeaturesLocks sold separatelyConstructed of super tough heavy-duty 14 gauge metal with baked enamel finishProtects fire alarm control panels and large electronic devices from extreme temperaturesACHeater unit is externally mounted to minimize space intrusionACHeater unit cycles and a fan runs continuously to sustain a uniform temperature inside the enclosureCost effective low maintenance and compact designIncludes mounting plateTwo 14 turn latches help prevent unauthorized entryMounts to the wall enabling units to be protected in their designated locationCabinet is Type 4 UL Listed CEACHeater unit ULcUL Listed CE36 in H x 24 in W x 8 in D

GBP 6600.86
1

Cooper CF800PROG Intelligent Addressable Device Programmer

Teal Products WMU836800-2 WMU 836-2 0800 Chain Actuator SYNC. 24V 800MM 300N 1A SAA

Teal Products WMU841000 WMU 842-1 1000 Chain Actuator 24V 1000MM 400N 2A SAA

Teal Products WMU8361000 WMU 836-1 1000 Chain Actuator 24V 1000MM 300N 1A SAA

Teal Products WMU84750 WMU 842-1 0750 Chain Actuator 24V 750MM 400N 2A SAA

Teal Products WMU8361000-2 WMU 836-2 1000 Chain Actuator SYNC. 24V 1000MM 300N 1A SAA

Teal Products WMU836800 WMU 836-1 0800 Chain Actuator 24V 800MM 300N 1A SAA

Baldwin Boxall CARE2 Type A Green Steward Emergency Telephone with Lock Door C2ETGL

C-Tec EAP28CAEA EAP 2L 8Z 5A CAST C-TEC EACIE Complete With Cabinet

C-Tec FF388-2 FP8 8 Zone Fire Panel

Baldwin Boxall CARE2 Type A Stainless Steel Fire Telephone with Lock Door C2FTSL

Howler SH05 SafetyHub With Automatic Sanitiser Dispenser And 5L Of Sanitiser

Apollo XP95 Intrinsically Safe Red Manual Call Point MEDC Style 55000-961APO

Klaxon Syrex EXD Buzzer ATEX 230v AC - TCA-0001 17-970220

Klaxon Syrex EXD Buzzer ATEX 24v DC - TCA-0005 17-970236

Klaxon Syrex EXD Buzzer ATEX 110v AC - TCA-0069 17-970235

Morley FSL100 UV Flame Detector

Commander BUN-CON-05 Flat-pack Construction Fire Point Stand Bundle amp Wireless Alarm

Patol N4587A-R02 Fibresense LHD - 2km LHD Interrogator Multimode MM Sensor

Patol N4587A-R02 Fibresense LHD - 2km LHD Interrogator Multimode MM Sensor

Patol N4587A-R02 Fibresense LHD - 2km LHD Interrogator Multimode MM SensorThe Linear Heat Detection LHD N45 Series technology detects fire quickly and identifies the location of the fire with maximum accuracy and reliability by using a fibre optic cable as a precise distributed heat sensor.The advanced LHD N45 Series goes far beyond conventional fire detection systems. This technology measures an accurate temperature profile every few seconds along a fibre optic cable up to 16km varies by model. It is unaffected by air currents and hence accurately determines the size and direction of a spreading fire. In large scale infrastructures the sensor cable typically runs through different areas under various temperature conditions. The fibre optic LHD solution lets you configure the appropriate alarm criteria in hundreds of zones along the same cable run regardless of how long your sensor cable actually is. The industrys fastest fire detection and lowest false alarm rate are in balance even under challenging conditions regardless of the application. The system is immune to dirt dust corrosive environments organic vapours extreme temperatures or radiation. Larger facilities have challenging installation and commissioning requirements and higher maintenance efforts. LHD N45 addresses these problems by using a standard fibre optic cable as a precise distributed heat sensor.With LHD N45 Series fire-fighting countermeasures can be used effectively before and throughout the fire event.Ideal for use in infrastructures and buildings such as rail and road tunnels airports mining shafts parking stations and warehouses.Each fibre optic LHD instrument is individually tested before shipping and must pass strict test limits. This ensures that every fibre optic LHD unit will meet or exceed the specifications in this data sheet. Adhering to our stringent quality control measures guarantees optimal performance and a long product life. Key FeaturesLong range coverageGapless fire detectionPrecise temperature monitoring fast fire detectionContinuously monitors the temperature at every point along the assetRack wall mounted optionUp to 4 channels0.5m spatial resolutionWeb based programming wit state of the art IT security standardsRugged housing design for outdoor and heavy duty applications

GBP 32615.52
1

Patol N4517A-R10 Fibre Optic Linear Heat Detection LHD Interrogator Multimode MM Sensor

Patol N4517A-R10 Fibre Optic Linear Heat Detection LHD Interrogator Multimode MM Sensor

Patol N4517A-R10 Fibre Optic Linear Heat Detection LHD Interrogator Multimode MM SensorThe Linear Heat Detection LHD N45 Series technology detects fire quickly and identifies the location of the fire with maximum accuracy and reliability by using a fibre optic cable as a precise distributed heat sensor.The advanced LHD N45 Series goes far beyond conventional fire detection systems. This technology measures an accurate temperature profile every few seconds along a fibre optic cable up to 16km varies by model. It is unaffected by air currents and hence accurately determines the size and direction of a spreading fire. In large scale infrastructures the sensor cable typically runs through different areas under various temperature conditions. The fibre optic LHD solution lets you configure the appropriate alarm criteria in hundreds of zones along the same cable run regardless of how long your sensor cable actually is. The industrys fastest fire detection and lowest false alarm rate are in balance even under challenging conditions regardless of the application. The system is immune to dirt dust corrosive environments organic vapours extreme temperatures or radiation. Larger facilities have challenging installation and commissioning requirements and higher maintenance efforts. LHD N45 addresses these problems by using a standard fibre optic cable as a precise distributed heat sensor.With LHD N45 Series fire-fighting countermeasures can be used effectively before and throughout the fire event.Ideal for use in infrastructures and buildings such as rail and road tunnels airports mining shafts parking stations and warehouses.Each fibre optic LHD instrument is individually tested before shipping and must pass strict test limits. This ensures that every fibre optic LHD unit will meet or exceed the specifications in this data sheet. Adhering to our stringent quality control measures guarantees optimal performance and a long product life. Key FeaturesLong range coverageGapless fire detectionPrecise temperature monitoring fast fire detectionContinuously monitors the temperature at every point along the assetRack wall mounted optionUp to 4 channels0.5m spatial resolutionWeb based programming wit state of the art IT security standardsRugged housing design for outdoor and heavy duty applications

GBP 72698.64
1