Kidde Airsense AAE-0500 Alarmline II Analogue Linear Heat Detection Cable PVC Coated 500m Roll Kidde Airsense AAE-0500 Alarmline II Analogue Linear Heat Detection Cable PVC Coated 500m RollThe Kidde Alarmline II analogue sensor cable is designed for use with the AAECU EN54 control unit only.It is PVC coated and suitable for indoor use.Operating Temperature Limits -40 to 125 Degrees CelsiusContinuous Operating temperature -40 to 90 Degrees CelsiusColour RedCable Diameter 4.57mm - 0.075mm Diameter 430 x 140dWeight 11.85kg GBP 3591.02 1
Kidde Airsense AAE-0100 Alarmline II Analogue Linear Heat Detection Cable PVC Coated 100m Roll Kidde Airsense AAE-0100 Alarmline II Analogue Linear Heat Detection Cable PVC Coated 100m RollThe Kidde Alarmline II analogue sensor cable is designed for use with the AAECU EN54 control unit only.It is PVC coated and suitable for indoor use.Operating Temperature Limits -40 to 125 Degrees CelsiusContinuous Operating temperature -40 to 90 Degrees CelsiusCable Diameter mm 300 Diameter x 100dWeight 2.37kg GBP 777.67 1
Crowcon S012016-II-4 Display PCB For Four-Channel Model Crowcon S012016-II-4 Display PCB For Four-Channel ModelA Display PCB For Four-Channel Model.Crowcon specialises in providing gas detection solutions for various industries and applications. As part of their product offerings Crowcon also provides an extensive range of spare parts and accessories specifically designed for their gas detection systems. GBP 611.52 1
Crowcon S012016-II-1 Display PCB For Single-Channel Model Crowcon S012016-II-1 Display PCB For Single-Channel ModelA Display PCB For Single-Channel Model.Crowcon specialises in providing gas detection solutions for various industries and applications. As part of their product offerings Crowcon also provides an extensive range of spare parts and accessories specifically designed for their gas detection systems. GBP 611.52 1
STI STI-1200A-HTR240 -- Stopper II Heated Enclosure 240 VAC With 4in Deep Backbox STI STI-1200A-HTR240 -- Stopper II Heated Enclosure 240 VAC With 4in Deep BackboxLarger cover helps prevent malicious or accidental false fire alarms. The Stopper II is a unique device which has helped prevent false fire alarms around the world for more than 30 years without restricting legitimate operation of devices such as fire alarm break glass call points. It is ideal for schools colleges hospitals nursing homes hotels and all public buildings where there is a history or a threat of false fire alarms.How It WorksThe Stopper II consists of a clear tamperproof tough polycarbonate cover and frame that retrofits over the break glass call point. When lifted to gain access to the break glass its optional battery powered integral sounder emits a piercing 95 dB or 105 dB at 1 metre. Immediate attention is drawn to the area and the prankster will either run or be caught.Details The clear protective polycarbonate cover is UV-stabilized Fan runs continuously to maintain a uniform temperature inside the enclosure Heater units cycle as required to maintain the correct range of operating temperatures 240 VAC heater Rated for indoor and outdoor applications Please note Due to the curvature of this model the depth stated will vary 158 mm H x 104 mm W x 31 mm D GBP 1338.48 1
Kidde Airsense ADLCU-2 AlarmLine II - Dual Zone Digital Location Control Unit Kidde Airsense ADLCU-2 AlarmLine II - Dual Zone Digital Location Control UnitThe digital location control unit is a dual zone module for monitoring upto two zones of AlarmLine Digital Linear Heat Detection Cable. If anoverheat or fire situation triggers either zone of the digital cable theunit automatically calculates and displays the distance along the cablein feet and metres to the alarm point.The two zones can operate independently of each other or in interlockmode. A separate alarm and normally conducting fault output areprovided for each zone. The unit is intended to be installed betweenthe AlarmLine digital linear heat detection cable and a conventional oraddressable fire alarm control panel. It has power fault and alarmindicators as well as free outputs for fault and alarm corresponding toeach zone. It may also be connected to a industrial process controlsystem using the two wire RS-485 Modbus RTU output.Key Features BenefitsDual Zone - used as Independent or InterlockDesigned for Alarmline II digital linear heat cableEasy to installIP65RoHS Compliant and CE CertifiedModbus support3km of cable supported per zoneWide supply voltageLow current consumption GBP 729.76 1
Kidde Airsense ADELCU-2 Alarmline II Digital LHD EN54-28 Dual Zone Location Control Unit Kidde Airsense ADELCU-2 Alarmline II Digital LHD EN54-28 Dual Zone Location Control UnitThe ADELCU-2 digital location control unit is a dual zone module for monitoring up to two zones of AlarmLine II Digital EN Linear Heat Detection Cable. If an overheat or fire situation triggers either zone of the digital cable the unit automatically calculates and displays the distance along the cable in feet and metres to the alarm point.The two zones can operate independently of each other or in interlock mode. A separate alarm and normally conducting fault output are provided for each zone. The unit is intended to be installed between the AlarmLine II digital EN linear heat detection cable and a conventional or addressable fire alarm control panel. It has power fault and alarm indicators as well as free outputs for fault and alarm corresponding to each zone. It may also be connected to a industrial process control system using the two wire RS-485 Modbus RTU output.Modbus communicationThe unit includes a two wire RS-485 Modbus output which can be enabled to output the status of each zone of the digital location control unit via Modbus RTUASCII protocol. In case of an alarm the location in distance along the cable is also communicated via Modbus.Interconnecting cableThe unit supports the use of a interconnecting cable leader cable in between the control unit and the linear heat detection cable. The interconnecting cable is used in applications where the control unit is not located in the detection zone. The interconnecting cable is then used to connect the control unit in one location with the linear heat detection cable in the protected area. The interconnecting cable is available in 100 m lengths under the product code AAI-0100.Key FeaturesDual Zone - used as Independent or InterlockDesigned for AlarmLine II Digital EN linear heat cableEasy to installIP Rating IP65RoHS compliant CE EN54-282016 certifiedModbus support1km of cable supported per zoneWide supply voltageLow current consumption GBP 1253.77 1
Kidde Airsense AAECU EN 54-22 Analogue LHD Composite Control Unit Alarmline II EN54 Kidde Airsense AAECU EN 54-22 Analogue LHD Composite Control Unit Alarmline II EN54The AAECU analogue control unit is provided with an LCD and internal control buttons to be able to calibrate and configure the control unit without a laptop.Key FeaturesSensor cable length - Min 30.5m Max 500mSupply voltage 20-28VDCCurrent consumption Quiescent - 70mA maxAlarm - 100mA max 2 x Volt free outputs Alarm Pre-Alarm rated 2A 30VDC0.25A 250VAC1 x Opto Isolated output Fault rated 20mA 50VDC1 x Isolated input Reset requires 20-28VDC pulse for min 5sAlarm and Pre-Alarm temperature range 54 - 100 Deg C 129 - 212 Deg F4 LED indicators Red - Alarm Red Pre-Alarm Amber - Fault Power GreenPolycarbonate enclosureIngress rating IP66 Dimensions mm 182w x 182h x 90d MUST be used with AAE cable GBP 1309.99 1
Notifier 843090-0210 Bose FreeSpace 3 Series II Acoustimass Bass Module - White - Flush Mount Notifier 843090-0210 Bose FreeSpace 3 Series II Acoustimass Bass Module - White - Flush MountDesigned to provide flush-mount bass augmentation for new and existing background music systems. Features one 5.25 133 mm woofer that delivers deep bass down to 40 Hz without audible distortion.For indoor applications only.Key FeaturesLow-frequency loudspeaker featuring one 5.25 133 mm woofer that delivers deep non-localized bass support down to 40 Hz without audible distortion. For flush ceiling pendant and wall-mount applicationsAcoustimass speaker technology filters out audible distortion to deliver non-localized bassDesigned to work with the FreeSpace 3 flush and surface satellite speakers or existing systems where additional bass reinforcement is desiredModule design allows parallel connection of multiple bass modules and can accommodate two or four FreeSpace 3 satellites per bass modulePlenum rated for use in air handling spaces with optional plenum coverSelectable 70100V or low impedance with transformer tap adjustment under speaker grille GBP 1067.26 1
International Gas Detectors BEXCS11005D24V Beacon Sounder International Gas Detectors BEXCS11005D24V Beacon SounderThe BEXCS11005D24V is a beacon sounder combined II 2 G EEx d IIB T4 32 Tone 110DB 5 Joule Supplied with Certificate. GBP 1369.29 1
Ziton FE590 Explosion Proof Wall Mount Door Magnet Ziton FE590 Explosion Proof Wall Mount Door MagnetThe FE590 is a surface mount explosion proof door holder in a cast housing which offers a 588N holding force.Key FeaturesExplosion proof surface mount body588N holding forceLow power - 3 WReverse polarity protectionATEX approval - EX IIG Eex me II T6 GBP 1741.42 1
Engineers Tool Kit ESTK Engineers Tool Kit ESTKThe ESTK is an Engineers Tool Kit. It features all the tools you need to service and maintain fire extinguishers.Included in the kitV-Clamp - Solid steel construction V Clamp. A great solution for gripping an extinguisher while removing the valve.Extinguisher Pressurising Bar - Pressurising extinguishers. Available for Jewel extinguishers.Filling Adapters Brass fittings set for pressurising most extinguishers.Digital Scale - Mains and battery powered plinth style digital scale. 60kg capacity 0.01kg increments. Auto battery save feature.Pressure Gauge Tester - Traditional gauge tester for use with gauges incorporating holes to allow pressure blow.Nitrogen Regulator Hose - Regulator with 25mm quick fit adaptor. Supplied with schrader fitting and hose tested to 200 BAR.Maintenance Labels - Our headcap removal spanner is the perfect tool for the job.Spring Balances - Ideal lightweight analogue scales for weighing fire extinguishers. GBP 992.64 1
Carrier ATS1204E 8-32 Zones DGP Input Expander 3A Power Supply Large Metal Housing EN Grade 3 Class II Carrier ATS1204E 8-32 Zones DGP Input Expander 3A Power Supply Large Metal Housing EN Grade 3 Class IIThe ATS1201E and ATS1204E expanders offer 8 standard inputs 8Open Collectors OC outputs and a siren driver. The expander can beextended to a total of 32 inputs and 32 outputs. It has a built-in 3 Aswitched mode power supply.ExpandersExpanders are used to expand the number of alarm inputs in anAdvisor Advanced system. Expanders allow inputs and outputsrelaysto be connected at a location remote from an Advisor Advanced panel.Expanders communicate via poll reply messages. Detectors doorcontacts and other detection devices are connected to expanders thatreport any change of state to the control panel for processing.Available expanders include support for conventional devices wirelessdevices as well as intelligent addressable devices. A special expanderis available providing expansion of four to eight intelligent doors or lifts.Key Features8 inputs on boardExpandable to 32 inputs8 Open Collector outputs on boardExpandable to 32 OC outputsrelays with optional cards1 siren outputSwitched mode power supply GBP 446.99 1
Klaxon Syrex EXD Buzzer ATEX 24v DC - TCA-0005 17-970236 Klaxon Syrex EXD Buzzer ATEX 24v DC - TCA-0005 17-970236The Exd Buzzer is an explosion proof buzzer designed for use in hazardous areas where a distinctive signal is required. Certified to ATEX II 2G Exd e IIC T6 it is suitable for use in Zone 1 and Zone 2 areas. Producing a tone with low frequency it cuts through background noise more effectively than many other devices of a similar output. Mounted in a rugged reinforced polyester case and weatherproof to IP66 it is suitable for use in the most arduous conditions.Key FeaturesRated for Category 2 use formerly Zone 1 2ATEX approvedII 2G Exd e IIC T6Heavy duty buzzerWeatherproof to IP66Rugged construction GBP 1685.24 1
Klaxon Syrex EXD Buzzer ATEX 110v AC - TCA-0069 17-970235 Klaxon Syrex Exd Buzzer ATEX 110v AC - TCA-0069 17-970235The Exd Buzzer is an explosion proof buzzer designed for use in hazardous areas where a distinctive signal is required. Certified to ATEX II 2G Exd e IIC T6 it is suitable for use in Zone 1 and Zone 2 areas. Producing a tone with low frequency it cuts through background noise more effectively than many other devices of a similar output. Mounted in a rugged reinforced polyester case and weatherproof to IP66 it is suitable for use in the most arduous conditions.Key FeaturesRated for Category 2 use formerly Zone 1 2ATEX approvedII 2G Exd e IIC T6Heavy duty buzzerWeatherproof to IP66Rugged construction GBP 1685.24 1
Klaxon Syrex EXD Buzzer ATEX 230v AC - TCA-0001 17-970220 Klaxon Syrex Exd Buzzer ATEX 230v AC - TCA-0001 17-970220The Exd Buzzer is an explosion proof buzzer designed for use in hazardous areas where a distinctive signal is required. Certified to ATEX II 2G Exd e IIC T6 it is suitable for use in Zone 1 and Zone 2 areas. Producing a tone with low frequency it cuts through background noise more effectively than many other devices of a similar output. Mounted in a rugged reinforced polyester case and weatherproof to IP66 it is suitable for use in the most arduous conditions.Key FeaturesRated for Category 2 use formerly Zone 1 2ATEX approvedII 2G Exd e IIC T6Heavy duty buzzerWeatherproof to IP66Rugged construction GBP 1685.24 1
Apollo I.S. Conventional Triple IR Flame Detector 55000-063APO Apollo I.S. Conventional Triple IR Flame Detector 55000-063APOThe IS IR3 Flame Detector is designed for harsh environments in either indoor or outdoor applications. It is sensitive to low frequency flickering IR radiation emitted from flames during combustion.The sensor operates even through a layer of oil dust water vapour or ice. These detectors have been approved byBaseefa to standards EN50014 EN50020 and EN50284. The requirements of Directive 949EC the Atmosphere Explosives ATEX directive have also been met.Key Features ATEX IECEx certified II 1 GCENELECIEC Certified Ga Ex ia IIC T4Selectable output options Conventional two-wire 4-20mA Latching or Non-latching RelayContacts - FireFault Pre alarmClass 1 sensitivity to EN54-10 detects 0.1m2 fire at 25mHigh optical interference immunitySelectable response speedOptical self-testLow power consumptionIP65 ratedSupply voltage 14 to 30VdcOperating temperature -10C to 40C T4Operating temperature -10C to 55C GBP 2233.04 1
Klaxon TCB-0018 EXD Sounder 100-240v AC Klaxon EXD Sounder 100-240v AC - TCB-0018The EXD Sounder has been approved for use in potentially explosive atmospheres and very harsh environmental conditions. The unit incorporates a three stage alarm option with sixty three tones to choose from which includes four tones that can be recorded or customised by the installer. All tones can be pre-set during installation.The units also have the ability to be fitted with a telephone initiation function and can be used as the second ring output indicator for telephones when installed in very noisy environments. The design allows for termination inside the enclosure. The sounder is supplied with a mounting bracket as standard.Key FeaturesApproved by ATEX and CQST IMETRO and IECEXPendingATEX II 2G Exd IIC T4 - T6 incorporating IIA IIBZones 12 Zones 2122 PendingConforms to EN IEC 60079-0 EN IEC 60079-1 and EN54Volume controlDustproof Weatherproof GBP 975.95 1
Klaxon TCB-0017 EXD Sounder 24v DC Klaxon TCB-0017 EXD Sounder 24v DCThe EXD Sounder has been approved for use in potentially explosive atmospheres and very harsh environmental conditions. The unit incorporates a three stage alarm option with sixty three tones to choose from which includes four tones that can be recorded or customised by the installer. All tones can be pre-set during installation.The units also have the ability to be fitted with a telephone initiation function and can be used as the second ring output indicator for telephones when installed in very noisy environments. The design allows for termination inside the enclosure. The sounder is supplied with a mounting bracket as standard.Key FeaturesApproved by ATEX and CQST IMETRO and IECEXPendingATEX II 2G Exd IIC T4 - T6 incorporating IIA IIBZones 12 Zones 2122 PendingConforms to EN IEC 60079-0 EN IEC 60079-1 and EN54Volume controlDustproof Weatherproof GBP 948.26 1
Apollo Exd Conventional UV Dual IR Flame Detector 55000-065APO Apollo Exd Conventional UV Dual IR Flame Detector 55000-065APOThe Flameproof UVIR2 Flame Detector is designed for hazardous environments in either indoor or outdoor applications where open fires may be expected. False alarms from flickering sunlight arc welding or lightning are avoided by the combination of UV and dual IR signal processing techniques.It detects almost all flames including those invisible to the naked eye e.g. hydrogen fires. Certified by ISSOP for compliance with standards EN50014 EN50018 and EN50281. Key Features ATEX Certified II 2 G DCENELECIEC Certified EEx d - IIC T6- Zones 1 21 2 and 22Class 1 sensitivity to EN54-10 detects 0.1m2 fires at 25mHighest optical interference immunitySelectable output options Conventional two-wire 4-20mA Relay Contacts - FireFault Pre alarm Latching or Non-latchingSelectable response speedRemote control self-testLow power consumptionIP66 ratedSupply voltage 14 to 30VdcOperating temperature -10C to 55C GBP 2340.00 1
Klaxon EXD Beacon Amber 5W LED Lens 12-48v DC - TCB-0013 Klaxon EXD Beacon Amber 5W LED Lens 12-48v DC - TCB-0013The EXD Beacon range has been approved for use in potentially explosive atmospheres and very harsh environmental conditions. These beacons have a choice of two types of light source either Xenon strobe with multiple flash rate and power ratings or an LED array with three status type indication options and two power ratings.The design allows for termination inside the enclosure. The units also have the ability to be fitted with a telephone initiation function and can be used as the second ring output indicator for telephones when installed in very noisy environments.Key FeaturesApproved by ATEX and CQST IMETRO and IECEX PendingATEX II 2G Exd IIC T4 - T6 incorporating IIA IIBZones 12 Zones 2122 PendingConforms to EN IEC 60079-0 EN IEC 60079-1 and EN54360 degree light output around the vertical axisDustproof Weatherproof GBP 918.26 1
Klaxon Syrex Exd Bell ATEX 24v DC - TCA-0004 17-970234 Klaxon Syrex Exd Bell ATEX 24v DC - TCA-0004 17-970234The Exd Bell is designed for use in Zone 1 and 2 areas and for areas requiring a high degree of weatherproof protection. IP66 rated and certified to ATEX II 2G Exd e IIC T6 it can be used in almost any environment. With a sound output of up to 105dB it provides a clear signal which stands out against background noise.A telephone ringing version is also available. The housing is manufactured from glass fibre reinforced polyester with stainless steel fittings designed to cope in arduous conditions. In addition all DC versions are equipped with a non-wearing electronic contact breaker which gives a long and reliable life.Key FeaturesRated for Category 2 use formerly Zone 1 2ATEX approvedII 2G Exd e IIC T6Clear audible signal designed to penetrate background noiseWeatherproof to IP66Rugged constructionChoice of voltages GBP 1787.38 1
Klaxon EXD Beacon Red 10W LED Lens 100-240v AC - TCB-0016 Klaxon EXD Beacon Red 10W LED Lens 100-240v AC - TCB-0016The EXD Beacon range has been approved for use in potentially explosive atmospheres and very harsh environmental conditions. These beacons have a choice of two types of light source either Xenon strobe with multiple flash rate and power ratings or an LED array with three status type indication options and two power ratings.The design allows for termination inside the enclosure. The units also have the ability to be fitted with a telephone initiation function and can be used as the second ring output indicator for telephones when installed in very noisy environments.Key FeaturesApproved by ATEX and CQST IMETRO and IECEX PendingATEX II 2G Exd IIC T4 - T6 incorporating IIA IIBZones 12 Zones 2122 PendingConforms to EN IEC 60079-0 EN IEC 60079-1 and EN54360 degree light output around the vertical axisDustproof Weatherproof GBP 918.26 1
Klaxon EXD Beacon 20J Xenon Red Lens 12-48v DC TCB-0011 Klaxon EXD Beacon 20J Xenon Red Lens 12-48v DC TCB-0011The EXD Beacon range has been approved for use in potentially explosive atmospheres and very harsh environmental conditions. These beacons have a choice of two types of light source either Xenon strobe with multiple flash rate and power ratings or an LED array with three status type indication options and two power ratings.The design allows for termination inside the enclosure. The units also have the ability to be fitted with a telephone initiation function and can be used as the second ring output indicator for telephones when installed in very noisy environments.Key FeaturesApproved by ATEX and CQST IMETRO and IECEX PendingATEX II 2G Exd IIC T4 - T6 incorporating IIA IIBZones 12 Zones 2122 PendingConforms to EN IEC 60079-0 EN IEC 60079-1 and EN54360 degree light output around the vertical axisDustproof Weatherproof GBP 930.05 1
Klaxon Syrex Exd Bell ATEX 230v AC - TCA-0002 17-970232 Klaxon Syrex Exd Bell ATEX 230v AC - TCA-0002 17-970232The Exd Bell is designed for use in Zone 1 and 2 areas and for areas requiring a high degree of weatherproof protection. IP66 rated and certified to ATEX II 2G Exd e IIC T6 it can be used in almost any environment. With a sound output of up to 105dB it provides a clear signal which stands out against background noise.A telephone ringing version is also available. The housing is manufactured from glass fibre reinforced polyester with stainless steel fittings designed to cope in arduous conditions. In addition all DC versions are equipped with a non-wearing electronic contact breaker which gives a long and reliable life.Key FeaturesRated for Category 2 use formerly Zone 1 2ATEX approvedII 2G Exd e IIC T6Clear audible signal designed to penetrate background noiseWeatherproof to IP66Rugged constructionChoice of voltages GBP 1787.38 1