105 results (0,14043 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

Ziton A45E-2 Addressable Interface Module

Ziton A45E-2 Addressable Interface Module

Ziton A45E-2 Addressable Interface ModuleThe A45E-2 addressable interface is designed for installation within the enclosures of equipment associated with fire detection systems. The unit is installed directly onto the ZP loop wiring carries a system address and enables signals from associated equipment to be interfaced into the fire alarm system. Input signals are fully displayed at the control panel and can be programmed to activate any system output. By routing loop wiring and installing interfaces adjacent to input equipment system integrity is decreased and the need for long spur wiring between equipment terminals and the fire alarm interface is eliminated.Complying with EN54 Part 18 the A45E-2 can be installed singly or used in groups to provide multiway inputs from equipment such as volt free zonal outputs from conventional fire alarm systems or flow valves from sprinkler installations. Housed in a low profile single width moulding the interface is designed to clip directly onto a standard DIN rail fixing or be installed in a SMB-DIN100 box two unit capacity or a SMB-DIN200 box four unit capacity.A red LED indicator positioned on the front moulding flashes when the interface has operated providing clear identification of the input signal source. Installed as part of an analogue addressable system up to 127 line devices sensors callpoints or interface units can be connected to each of the control panel loops. All loop devices incorporate switch settings enabling them to be assigned a unique address which is polled by the panel every two seconds.Key FeaturesAddressable input interface unitComplies with EN54 Part18Low profileDIN rail mountedAccepts normally open input circuitsMonitors input circuit wiring for open or short circuit faults

GBP 35.50
1

Ziton A70E-2 Conventional Zone Interface

Ziton A70E-2 Conventional Zone Interface

Ziton A70E-2 Conventional Zone InterfaceThe A70E-2 zone interface is fully loop powered and enables existing or new conventional zones to be interfaced to an analogue system allowing all areas of a site to be controlled by the ZP analogue panel. Through its interface each zone is assigned a unique address. Zones are monitored for fire and fault conditions and status is reported to the ZP control panel every 2 seconds. Zones of up to 15 Ziton Z600 conventional trigger devices can be connected to the interface with a maximum of 127 interface units installed on each ZP loop.The A70E monitors its conventional zone wiring for open and short circuit faults via end of line resistors supplied with the unit. When detectors are installed with Z6-BS5 bases the interface maintains complete operation of all other zone devices should a detector from within the zone be emoved from its base. Clear visual indication is shown on the front of the A70E moulding for alarm red LED and fault amber LED.Deriving power directly from the loop wiring and with a low current consumption in addition to zonal connection the interface has many system applications ranging from the interface of equipment for hazardous areas to the operation of magnetic door retainers via an interposing relay and linear beam detectors. Housed in low profile mouldings the interface is designed to clip directly onto a standard DIN35 rail fixing or be installed in a SMB-DIN100 box one unit capacity or a SMB-DIN200 box two unit capacity. In systems where numerous interfaces are installed or current requirement is excessive the A70E can be powered from an external power supply.Key FeaturesInterfaces up to 15 Ziton Z600 conventional devices to the ZP loopAddressable - reports status every 2 secondsMonitors conventional zone wiringDetector removal monitoring with Z6-BS5 basesDIN35 rail mountedUp to 127 conventional zones interfaced to each ZP loop with external PSU

GBP 114.34
1

Ziton 2010-2-PIB Interface Printer Circuit Board

Ziton 2010-2-PIB Interface Printer Circuit Board

Ziton 2010-2-PIB Interface Printer Circuit BoardThe 2010-2-PIB Peripherals Interface Board is an accessory of the small to medium size intelligent addressable life safety control systems. In total there are 4 variants of this board. The 2010-2-PIB is the most extended variant of the range and provides ways to interface other electronic equipment on site.The board can be plugged directly on the front of the main board inside the big size control panel variants on top of the new release 3 chassis. No additional wiring is required. You can use the pluggable connectors to make your connections to the field wiring. Connect an external power supply to the board directly to reduce the load of your system.The 2010-2-PIB Peripherals Interface Board provides eight inputs and outputs and four relay outputs for compatible control panels. The board is designed to support German marketplace requirements in control panels operating in VdS 2540 mode and provides an interface to the IFAM System 3000 network fire brigade equipment and other regional control and indicating equipment and devices. The board can be powered from the control panel or from an external power supply providing 24 VDC to each of the supervised outputs. Inputs and outputs excluding relay outputs are supervised for short circuit and open circuit faults.Key Features8 supervised inputs8 supervised outputs4 relay outputsOption to externally powerInterface to the IFAM System 3000 networkOperating in VdS 2540 modePluggable connectors

GBP 182.74
1

Ziton ZP3AB-SCB-R Serial Control Bus Interface

Ziton 2010-2-PIB-8O Interface Printer Circuit Board with 8 Outputs

Ziton 2010-2-PIB-8I Interface Printer Circuit Board with 8 Inputs

Ziton 2010-2-PIB-8I8O Interface Printer Circuit Board with 8 Inputs 8 Outputs

Ziton ZP2-F2 Addressable Fire Panel With User Interface 2 Loop

Ziton ZP2-F1 Addressable Fire Panel With User Interface 1 Loop

Ziton ZP752-2 Addressable Loop Interface Unit 13810-ZT

Ziton ZP752-2 Addressable Loop Interface Unit 13810-ZT

Ziton ZP752-2 Addressable Loop Interface Unit 13810-ZTThe ZP752-2 is a loop wired interface providing two conventional alarm circuits. It may programmed to operate from a single address a group or zone of devices or as a common output from any trigger device connected to the system.Power for the alarm circuits is supplied either from an external power supply unit or directly from the panels 24VDC supply via separate wiring. The ZP752-2 monitors its power supply and failure is reported to the main control panel automatically.On operation both sounder circuits are simultaneously activated. A red LED indicator is illuminated on the front of the unit to confirm operation.Fully monitored for open and short circuit faultsAny number of ZP752-2 units up to a max of 127 can be connected to the ZP loop. In systems complying with the recommendations of BS5839-1 where sounder response to the operation of a manual call point must be within 3 seconds up to 16 ZP752-2 output units assigned to the first 16 addresses on each loop can be operated within the time period.Wiring is monitored for open and short circuit faults by means of end of line resistors. Faults are automatically reported to the control panel together with the address of the ZP752-2 interface. An amber LED indicator on the front of the moulding is illuminated to indicate the fault condition.First and second fix installationDesigned for first and second fix installation the unit comprises an open back box containing all wiring terminals together with a front plate enclosure of high impact plastic housing all electronics printed circuit boards and selection switches. The two parts simply plug together prior to system completion.All loop devices incorporate switch settings enabling them to be assigned a unique address which is polled by the panel every two seconds.Key FeaturesTwo monitored sounder circuitsSupport for 3s response from manual call pointsAddressable - connects to ZP loopProgrammable for continuous or pulsed output

GBP 98.81
1

Ziton Conventional Network Interface Board 2010-1-NB

Ziton Conventional Network Interface Board 2010-1-NB

Ziton Conventional Network Interface Board 2010-1-NBThe 2010-1-NB RS485 FireNet network board allows for the creation of a bus mode class-B or redundant class-A 32 node network supporting up to 64 zones. Each node may be a fire panel or a fire panel repeater. When optical fibre is preferred when cable lengths above 1200 m between nodes are required or in cases where high levels of EMC are expected a standard RS485 to fibre converter may be used.The 2010-1-NB is connected directly to the main board of the panel. No cabling needs to be done between the network board and the main board.The ApplicationNetworking makes it possible to repeat the user interface of any panel as required. There could be various reasons for using a network e.g.If there are multiple exit doors in a building and at each exit door the status of the fire system is requiredWhere the load of the system needs to be spread to safeguard against failure of a single panelTo minimise cabling and installation costsFor larger installations where multiple panels are required but yet central control is required at a single location.Networking is also useful when an existing system needs to be expanded. Instead of replacing a perfectly good panel with a larger one simply install and additional panel and connect them together in a network. This makes it ideal for cost effective future expansion.Key FeaturesClass A or B network supportUp to 1200 m between nodesMay be used for panels and repeatersUp to 32 nodes 64 zonesPluggable connectorsConnects directly to the main boardAllows networking between conventional and addressable panels

GBP 216.76
1

Ziton ZP2-F2-S Addressable Fire Panel With User Interface 2 Loop Small Cabinet

Ziton ZP2-F1-S Addressable Fire Panel With User Interface 1 Loop Small Cabinet

Ziton ZP1-F4 Conventional Fire Panel With User Interface 4 Zone

Ziton ZP1-F4 Conventional Fire Panel With User Interface 4 Zone

Ziton ZP1-F4 Conventional Fire Panel With User Interface 4 ZoneZP1 fire control panels offer state of the art architecture in configurations that deliver an uncomplicated solution for small to midsized conventional applications. They feature an attractive contemporary design that fits with any decor. The gently curved door front offers a distinctive flair. Operator controls are inset in a striking blue lexan.With support for multiple lines of conventional detectors and accessories these quick-to-configure systems offer versatility that benefits building owners and installationmaintenance companies alike.The ZP1-F4 is a conventional fire alarm control panel. It is supplied in local language with 4 zones that support up to 32 devices per zone as well as up to 4 supervised relay outputs dedicated to sounder control and fire routing. In addition 2 conventional relay outputs dedicated to common fire and fault conditions as well as two user configurable inputs for monitoring and control are available.The panels support 2 types of auxiliary relay boards one with 4 standard relays and one with 4 supervised relays. With these boards the panel outputs may be expanded with up to 16 additional outputs.Key FeaturesModern elegant designEasy removable parts for quick and clean installationDefault regional setup modesNormal head-out intrinsically safe zone supportSupervised alarm notification fire protection outputsEN54 compliant potential free fire fault relaysClass change daynight remote reset extended fire routing delay fire routing inhibit delay facilitiesAuxiliary 24VDC supply output with reset supportDefault support for special functions such as - EN54 compliant user access levels - mixed zones - full front panel diagnostics - one-man walk testAuxiliary standard supervised relay output boardsNetworkable up to 64 zones

GBP 235.15
1

Ziton ZP1-F2 Conventional Fire Panel With User Interface 2 Zone

Ziton ZP1-F2 Conventional Fire Panel With User Interface 2 Zone

Ziton ZP1-F2 Conventional Fire Panel With User Interface 2 ZoneZP1 fire control panels offer state of the art architecture in configurations that deliver an uncomplicated solution for small to midsized conventional applications. They feature an attractive contemporary design that fits with any decor. The gently curved door front offers a distinctive flair. Operator controls are inset in a striking blue lexan.With support for multiple lines of conventional detectors and accessories these quick-to-configure systems offer versatility that benefits building owners and installationmaintenance companies alike.The ZP1-F2 is a conventional fire alarm control panel. It is supplied in local language with 2 zones that support up to 32 devices per zone as well as up to 2 supervised relay outputs dedicated to sounder control and fire routing. In addition 2 conventional relay outputs dedicated to common fire and fault conditions as well as two user configurable inputs for monitoring and control are available.The panels support 2 types of auxiliary relay boards one with 4 standard relays and one with 4 supervised relays. With these boards the panel outputs may be expanded with up to 16 additional outputs.Key FeaturesModern elegant designEasy removable parts for quick and clean installationDefault regional setup modesNormal head-out intrinsically safe zone supportSupervised alarm notification fire protection outputsEN54 compliant potential free fire fault relaysClass change daynight remote reset extended fire routing delay fire routing inhibit delay facilitiesAuxiliary 24VDC supply output with reset supportDefault support for special functions such as - EN54 compliant user access levels - mixed zones - full front panel diagnostics - one-man walk testAuxiliary standard supervised relay output boardsNetworkable up to 64 zones

GBP 176.24
1