Ziton ZR455V-3RR Wireless Red Sounder with Red Beacon Ziton ZR455V-3RR Wireless Red Sounder with Red BeaconThe ZR455V-3RR is a RED addressable wireless sounderbeacon with a RED lens operating on 868 MHz. It is remotely controlled and supervised by an addressable wireless system controller allowing for both wireless and hardwired devices to be seamlessly located on the same fire system.ZR455V-3 sounderbeacons feature selectable tones for notification of alert evacuate security alert and class change with outputs up to 96 dBA as well as visual notification via an LED beacon located on the front of the unit.Key FeaturesFully addressableNo external aerialsWireless range in excess of 150 mTamper supervisionHigh output 32 selectable tonesAcoustic self-testDual battery supply5 year battery life at normal conditionsHarmonised European 868 MHz frequency bandCPD certified GBP 250.69 1
Ziton ZR432-2PA Wireless Smoke and Heat Detector with Sounder Base Polar White Ziton ZR432-2PA Wireless Smoke and Heat Detector with Sounder Base Polar WhiteThe ZR432-2PA is an addressable wireless POLAR WHITE multisensor capable of operating in optical temperature or multisensor modes. In addition it supports an integrated sounder all controlled from the main control panel via a wireless radio interface.Configurable Alarm ResponseDesigned to provide the earliest response to a wide range of fire types in locations where hard wiring is not an option ZR432 detectors combine optical smoke sensing and thermal monitoring to provide an accurate warning of fire. Smoke sensing may be isolated for areas where ambient smoke may exist at certain times of the day or used on a day night basis in premises where heat only is required whilst the building is occupied. Temperature and smoke sensitivity may be set on installation on each device.Device ControlThe ZR432-2PA is supervised and controlled from the main fire panel CIE. Every wireless device is assigned its own IDENT address with which the main control panel communicates providing the same system facilities as directly wired devices.The sounder may be configured during installation for high up to 87 dBA or low up to 74 dBA sound levels with selectable frequencies for two stage tone support both warning and alarm tones. The tones are controlled from the COE in the same way as for hardwired sounders.SupervisionCalibration and self-testing are carried out automatically. Removal or replacement of an incorrect devices is identified by the system and details displayed at the CIE. Sophisticated auto contamination adjustment compensates for any long-term drift in performance caused by dirt entering the sensing chamber.For ease of removal ZR432 detectors plug into the radio base by a simple twist and lock action. A selectable locking mechanism prevents unauthorised removal of the detector from its base.Key FeaturesNo external aerialsDual battery supply with up to 5 year battery lifeFull status monitoring batteries head supervision and tamperConfigurable as smoke only heat only or combination detection2-way wireless communication with variable power outputSounder with configurable tones and volumeSynchronised operationTwo stage evacuation operation supportETSI 300-220 approvedEN54357 and EN5425 compliant and CPR certified GBP 232.56 1
Ziton ZR432-2PAV Radio Dual Optical Heat Detector with Sounder Base Red Indicator Ziton ZR432-2PAV Radio Dual Optical Heat Detector with Sounder Base Red IndicatorThe ZR432-2PAV is an addressable wireless POLAR WHITE multisensor capable of operating in optical temperature or multisensor modes. In addition it supports an integrated sounder with visual indicator all controlled from the main control panel via a wireless radio interface.Configurable Alarm ResponseDesigned to provide the earliest response to a wide range of fire types in locations where hard wiring is not an option ZR432 detectors combine optical smoke sensing and thermal monitoring to provide an accurate warning of fire. Smoke sensing may be isolated for areas where ambient smoke may exist at certain times of the day or used on a day night basis in premises where heat only is required whilst the building is occupied. Temperature and smoke sensitivity may be set on installation on each device.Device ControlThe ZR432-2PAV is supervised and controlled from the main fire panel CIE. Every wireless device is assigned its own IDENT address with which the main control panel communicates providing the same system facilities as directly wired devices.The sounder may be configured during installation for high up to 87 dBA or low up to 74 dBA sound levels with selectable frequencies for two stage tone support both warning and alarm tones. The tones are controlled from the COE in the same way as for hardwired sounders. The red 360 visual indicator non EN5423 complaint allows for a 0.5 Hz flash rate and supports the sounder activation for noisy environments.SupervisionCalibration and self-testing are carried out automatically. Removal or replacement of an incorrect devices is identified by the system and details displayed at the CIE. Sophisticated auto contamination adjustment compensates for any long-term drift in performance caused by dirt entering the sensing chamber.For ease of removal ZR432 detectors plug into the radio base by a simple twist and lock action. A selectable locking mechanism prevents unauthorised removal of the detector from its base.Key FeaturesNo external aerialsDual battery supply with up to 5 year battery lifeFull status monitoring batteries head supervision and tamperConfigurable as smoke only heat only or combination detection2-way wireless communication with variable power outputSoundervisual indicator combination with configurable tones and volumeSynchronised operationTwo stage evacuation operation supportETSI 300-220 approvedEN54357 and EN5425 compliant and CPR certified GBP 318.46 1