Zeta ZT-DU2 Zeta Duct Unit Enclosure cw 2 x Sampling Probes Zeta ZT-DU2 Zeta Duct Unit Enclosure cw 2 x Sampling ProbesThe Zeta Duct unit allows air in a ventilation duct to be monitored for smoke via a smoke detector mounted outside the duct - in a sealed chamber.The unit comes supplied with 2 sampling probes one in one out which are mounted through the duct in the centre of the airflow.For a reliable smoke detection the airspeed in the duct must be at least 2.5 ms. The unit can be powered from either 230V AC or a separate 24V power supply. The unit has form C relay outputs for Alarm and for fault.Key FeaturesFeatures Fire and Fault relaysOption for latching or non-latchingManual reset latching option GBP 68.38 1
Zeta ZT-DU2CB Zeta Duct Unit Enclosure cw Detector Base and 2 x Sampling Probes Zeta ZT-DU2CB Zeta Duct Unit Enclosure cw Detector Base and 2 x Sampling ProbesThe Zeta Duct unit allows air in a ventilation duct to be monitored for smoke via a smoke detector mounted outside the duct - in a sealed chamber.The unit comes supplied with 2 sampling probes one in one out which are mounted through the duct in the centre of the airflow.For a reliable smoke detection the airspeed in the duct must be at least 2.5 ms. The unit can be powered from either 230V AC or a separate 24V power supply. The unit has form C relay outputs for Alarm and for fault.Key FeaturesFeatures Fire and Fault relaysOption for latching or non-latchingManual reset latching option GBP 70.44 1
Zeta ZT-DU2CBAR Zeta Duct Unit Enclosure cw 12V Auto Relay Base and 2 x Sampling Probes Zeta ZT-DU2CBAR Zeta Duct Unit Enclosure cw 12V Auto Relay Base and 2 x Sampling ProbesThe Zeta Duct unit allows air in a ventilation duct to be monitored for smoke via a smoke detector mounted outside the duct - in a sealed chamber.The unit comes supplied with 2 sampling probes one in one out which are mounted through the duct in the centre of the airflow.For a reliable smoke detection the airspeed in the duct must be at least 2.5 ms. The unit can be powered from either 230V AC or a separate 24V power supply. The unit has form C relay outputs for Alarm and for fault.Key FeaturesFeatures Fire and Fault relaysOption for latching or non-latchingManual reset latching option GBP 80.41 1
Zeta ZAZM-MIMARK1 Zone Monitoring Unit Zeta ZAZM-MIMARK1 Zone Monitoring UnitThe Zeta ZAZM-MIMARK1 is an addressable zone monitoring unit that can be used for conventional devices andor for special detectors. Supplied with a back box for surface mounting indoors. Meets EN54-18 2005 EN54-17 2005. 2 gang box size enclosure.Key FeaturesZone monitoring unitMKI protocolIndoorSurface mount GBP 79.06 1
Zeta ZT-DU2RB48 Zeta Duct Unit Enclosure cw 48V Dual Auto Relay Base and 2 x Sampling Probes Zeta ZT-DU2RB48 Zeta Duct Unit Enclosure cw 48V Dual Auto Relay Base and 2 x Sampling ProbesThe Zeta Duct unit allows air in a ventilation duct to be monitored for smoke via a smoke detector mounted outside the duct - in a sealed chamber.The unit comes supplied with 2 sampling probes one in one out which are mounted through the duct in the centre of the airflow.For a reliable smoke detection the airspeed in the duct must be at least 2.5 ms. The unit can be powered from either 230V AC or a separate 24V power supply. The unit has form C relay outputs for Alarm and for fault.Key FeaturesFeatures Fire and Fault relaysOption for latching or non-latchingManual reset latching option GBP 85.91 1
Zeta ZAZM-MI Fyreye MkII Addressable Zone Monitoring Unit With SC Isolator Zeta ZAZM-MI Fyreye MkII Addressable Zone Monitoring Unit With SC IsolatorThe Zeta ZAZM-MI is an addressable zone monitoring unit that can be used for a zone of conventional devices andor for special detectors that are not available in addressable form such as UV detectors aspirating detectors etc.The ZAZM-MI is supplied in a modern enclosure 2 gang box size with well protected electronic circuit board to minimize any damages during installation. It is supplied with a back box suitable for surface mount indoor installation. Designed and manufactured to meet the requirements of EN54-18 2005 and EN54-17 2005.Key FeaturesThis is a loop powered device however loop load calculation must be performed to determine the permissible quantity of ZAZM-MI per loopHand-addressed using the 8 way dip switch ORSoft addressed using a handheld MKII Programmer part no. 48-004Equipped with short circuit line isolatorExtensive front unit indications GBP 57.38 1
Zeta 10-061 Wi-Fyre Wireless InputOutput Unit With Batteries White Zeta 10-061 Wi-Fyre Wireless InputOutput Unit With Batteries WhiteThe Wi-Fyre Wireless InputOutput Module has been designed to provide a means to trigger an alarm or fault from ancillary input operations andor to switch remote equipment in the event of an alarm condition. When operating together with a transponder set to mode 5 it can also be used as a reflective inputoutput device to wirelessly interconnect two or more stand-alone fire alarm panels together.Key FeaturesEN54-25 approved868 870 MHz operating frequencyPowered by lithium metal batteriesSufficient cable spaceAvailable in red or white GBP 252.09 1
Zeta 10-060 Wi-Fyre Wireless InputOutput Unit With Batteries Red Zeta 10-060 Wi-Fyre Wireless InputOutput Unit With Batteries RedThe Wi-Fyre Wireless InputOutput Module has been designed to provide a means to trigger an alarm or fault from ancillary input operations andor to switch remote equipment in the event of an alarm condition. When operating together with a transponder set to mode 5 it can also be used as a reflective inputoutput device to wirelessly interconnect two or more stand-alone fire alarm panels together.Key FeaturesEN54-25 approved868 870 MHz operating frequencyPowered by lithium metal batteriesSufficient cable spaceAvailable in red or white GBP 252.09 1
Zeta ZAIO230STD Mains Switching IO Unit Zeta ZAIO230STD Mains Switching IO UnitThe Mains IO Modules are fully monitored loop powered devices which permit the interfacing of third-party equipment with the Fire Alarm Control panel using normally open dry contact connections.The connection to the input is monitored for fault open or short circuit and Alarm conditions.The interface is used to monitor the contacts of an external system which must be interfaced to the Fire Alarm System for example a Flow Switch in a sprinkler system to indicate if the sprinklers have been activated or extinguishant level monitoring in Gas Extinguishing systems etc.Module is provided with a loop short-circuit isolator and with a voltage free single pole change over mains rated output. The output relay is always powered directly from the detection loop. It is not required to use an external 24V DC power supply. Relay operation is confirmed by an on-board red LED.Key FeaturesFast Activation ResponseLoop PoweredFive Status LEDs providedLow Power ConsumptionModule features an integral short-circuit loop isolatorSingle mains rated relay contact GBP 57.38 1
Zeta GSM-COM GSM Communicator Zeta GSM-COM GSM CommunicatorZeta GSM communicator is an interface that allows a fire alarm panel to send a SMS text message in the event of an alarm or a fault.The communicator accepts a standard Mobile Phone SIM card and is then programmed with the alarm information phone numbers via a PC.The unit can run on any power supply between 9 24V DC.The unit has 4 inputs 2 user definable outputs.The outputs can be manually operated by dialling the GSM communicator then entering a password. GBP 301.03 1
Zeta SCM-PM Printer Module Zeta SCM-PM Printer ModuleThe plug-in RS232 module will give a Smart Connect Multiloop panel the ability to interface the RS232 serial equipment and devices. This is most commonly used to connect the Smart Connect Multiloop to an RS232 panel printer or a desktop printer for real time event log printing. The module also has a 5V aux output that is used to provide power to the panels internal printer.Key FeaturesDesigned to EN54 Part 2Use to interface to RS232 devices5V aux output for use with panel printer onlyExtensive front unit indicationsQuick and easy to install by plugging the RJ45 cable into the module and control panel cable supplied with Unit GBP 161.52 1
Zeta MKII-TOOL Handheld Programming Tool Zeta MKII-TOOL Handheld Programming ToolThe MkII Handheld Programmer is designed to compliment all MkII devices and to assist the commissioning engineer on site.Smoke and heat detectors can be tested when plugged on the programmer and alarm LEDs can be verified prior to installation.The unit will softly address all devices without using the incorporated dip-switch on the field devices.The MkII Programmer can re-program the opto-heat detectors to either heat or smoke detector.Key Features2 LED indications. One to indicate that the unit is charging the other one indicates the status of the detectors remote LED outputBattery Charge state indicatorAuto-Off when the programmer is not operated for two minutesExternal Reset Function20x4 Character LCD Display GBP 140.89 1
Zeta SCM-RM Relay Module - 6 Output Zeta SCM-RM Relay Module - 6 OutputThe SCM-RM is a relay module that is designed to be DIN mounted inside of a Smart Connect Multi-loop control panel. Its powered and is interfaced to the panel via a RJ45 connection. The module has three form C relays which can be typically used to control lift operation during an alarm start fire pumps or stop ventilation fans etc.Each relay output can be configured as a common alarm common fault common technical alarm or a programmable output via the Smart Connect Multi-loop settings.Key FeaturesDesigned to meet EN54 Part 2 requirements3 x Form C relay outputsEach relay can be programmed to activate on Alarm Technical Alarm or FaultExtensive front unit indicationsQuick and easy to install by plugging the RJ45 cable into the module and control panel cable supplied with Unit GBP 161.52 1
Zeta 400-210R Fire Alarm Safety Isolator Switch Zeta 400-210R Fire Alarm Safety Isolator SwitchThis product provides a secure method for safety isolating the mains voltage supply to fire control and indicating equipment CIE also suitable for security and access control and indicating equipment.Both the Live and Neutral supply is switched and a fuse is also provided.The supply can only be isolated by an authorized person by means of a keylock switch. The key is removable in both ONOFF positions.The fuse cannot be removed without taking the cover off.A neon indicator is provided to indicate mains present at the switched output.General InstallationThe unit is supplied in a complete enclosure. The enclosure is of a standard single gang format with preformed holes for mounting on a surface or 20mm conduit box. The unit can be accessed by rectangular surface trunking. Please follow the latest IEEE electrical wiring practices. GBP 21.12 1
Zeta EX-OER3 Premier EX Pro Output Expansion - 3 Relay PCB Zeta EX-OER3 Premier EX Pro Output Expansion - 3 Relay PCBThe EX-OER output expansion relay board can be mounted inside the EX Pro to provide voltage-free changeover relay contacts for reset mode discharged abort and additional 1st stage 2nd stage output and extract fan output. One unit can be used.Key FeaturesExpansion board with either 3 or 8 voltage-free changeover relay contactsMounted inside Premier Ex Pro panel GBP 76.28 1
Zeta EX-OER8 Premier EX Pro Output Expansion - 8 Relay PCB Zeta EX-OER8 Premier EX Pro Output Expansion - 8 Relay PCBThe EX-OER output expansion relay board can be mounted inside the EX Pro to provide voltage-free changeover relay contacts for reset mode discharged abort and additional 1st stage 2nd stage output and extract fan output. One unit can be used.Key FeaturesExpansion board with either 3 or 8 voltage-free changeover relay contactsMounted inside Premier Ex Pro panel GBP 130.58 1
Zeta ZRPBW Conventional Raptor Sounder Beacon White Plastic White Flash Zeta ZRPBW Conventional Raptor Sounder Beacon White plastic White FlashThe Raptor conventional sounder with beacon has a coverage pattern of W 2.9 - 8.5 and the sounder part has 22 selective tones. It has been designed to make an electronics free first fix and is available in red or white.Key FeaturesComplies with EN54 Pt 3 Type B EN54 Pt 23107dB - 3dB 1m sound output22 Tone patterns site selectableSuitable for surface mounting onlyHoused in UL V0 flame retardant ABS3 x 20mm cable entries 2 top 1 bottomFirst fix wire to back box technologyFlashing rate 0.5HzPart No. 42-633Voltage 17 - 30V DCCurrent 24V DC 70mA Max Flash ColourWhite Flash Frequency 0.5HzBody Colour WhiteSounder Type BIP Rating IP 65Operating Temperature -10C to 55CSound Output 1m 107dB - 3dBSize mm with back box 150 x 146 x 107.5Weight 550g GBP 52.92 1
Zeta SCM-NM Network Module Zeta SCM-NM Network ModuleThe Smart Connect Multiloop system network has the facility to monitor indicate and control the functions of a fire alarm installation thus allowing signals to be distributed around a large site.The network will accommodate up to 64 nodes. The network uses RS485 data communication and a total network cable length of up to 10km is possible.On a Smart Connect Multiloop running in a network all events are reported at all panels are able to remotely program other panels sitting on the network. Operation of outputs over the network is determined by the programmed cause effects. Any input on the network can be programmed to operate any output.Key FeaturesDesigned to EN54 requirementsPeer-to-peer networkingComprehensive cross network cause effectsUp to 64 panels may be networked togetherRemote programming over the networkThe network can be configured with either a ring or bus topologyFault tolerant designExtensive front unit status indicationsQuick and easy to install by plugging the RJ45 cable into the module and control panel Cable supplied with unit GBP 323.02 1
Zeta ZRPBR Conventional Raptor Sounder Beacon Red Plastic White Flash Zeta ZRPBR Conventional Raptor Sounder Beacon Red plastic White FlashThe Raptor conventional sounder with beacon has a coverage pattern of W 2.9 - 8.5 and the sounder part has 22 selective tones. It has been designed to make an electronics free first fix and is available in red or white.Key FeaturesComplies with EN54 Pt 3 Type B EN54 Pt 23107dB - 3dB 1m sound output22 Tone patterns site selectableSuitable for surface mounting onlyHoused in UL V0 flame retardant ABS3 x 20mm cable entries 2 top 1 bottomFirst fix wire to back box technologyFlashing rate 0.5HzBrand ZetaProduct Sounder BeaconModel ZRPBRPart No. 42-632Flash Colour White Body Colour RedVoltage 17 - 30V DC Current 30V DC 70mA MaxIP Rating IP65 certified to IP33C Sounder Type BOperating Temperature -25C to 70CSound Output 1m 107dB - 3dBSize mm with back box 150 x 146 x 107.5 Weight 550g GBP 52.92 1
Zeta MKII-RLC MKII Conventional Remote LED Indicator Ceiling Mounted Zeta MKII-RLC MKII Conventional Remote LED Indicator Ceiling MountedThere are two models for the Conventional Remote LED Indicator a wall type MKII-RLW and ceiling mounted type requires a base MKII-RLC.Each unit has 2 LEDs that light up to indicate an alarm. It has the 8 LED appearance to keep its family identity.Key FeaturesEach indicator can be programmed for one device or up to 12 devicesEach indicator will be connected directly on to the detection loopRequires a base GBP 8.59 1
Zeta SCM-LAN TCPIP Module Connection To Zeta Remote Zeta SCM-LAN TCPIP Module Connection To Zeta RemoteThe Local area network module provides a Smart Connect Multiloop CIE with a TCP IP connection that allows the panel to report events to an external monitoring system such as Data-Log or Zeta Remote.Key FeaturesDesigned to meet EN54 requirementsTCP-IP output via RJ45Zeta Remote monitoring via a desktop PC or smartphone via the cloudRemote control via the cloudResponsive web interfaceHeartbeat LED that shows communication between the module and the motherboardExtensive front unit indicationsQuick and simple to install GBP 345.01 1
Zeta TS-OSR Type A Telephone Outstation - Red Handset Zeta TS-OSR Type A Telephone Outstation - Red HandsetThe TS-OSR is a Type A Telephone Outstation with a red handset.The Type A Outstation is compatible with the ETS-CP system for use as a standard fire telephone or a disabled refuge call unit.The unit is housed in a metal enclosure allowing duplex communication with LED indication for incoming calls.Key FeaturesEnclosure suitable for either Flush or Surface mountStatus LEDFull duplex operationAutomatically dials the control panel when off hookDual purpose fire telephone or disabled refuge call pointIP23 suitable for indoor use GBP 323.02 1
Zeta MKII-RLW MKII Conventional Remote LED Indicator Wall Mounted Zeta MKII-RLW MKII Conventional Remote LED Indicator Wall MountedThere are two models for the Conventional Remote LED Indicator a wall type MKII-RLW and ceiling mounted type requires a base MKII-RLC.Each unit has 2 LEDs that light up to indicate an alarm. It has the 8 LED appearance to keep its family identity.The MKII-RLW is supplied with a backbox for surface mounting. It is also available without backbox for flush fitting.Key FeaturesEach indicator can be programmed for one device or up to 12 devicesEach indicator will be connected directly on to the detection loop GBP 7.21 1
Zeta ZASC-MI Sounder Control Module Zeta ZASC-MI Sounder Control ModuleThe ZASC-MI is supplied in a modern enclosure 2 gang box size with well protected electronic circuit board to minimize any damages during installation.It is supplied with a back box suitable for surface mount indoor installation. Designed and manufactured to meet the requirement of EN54-18 2005 and EN54-17 2005.Key FeaturesThis is not a loop powered device and an adequate 24Vdc input with battery backup is neededHand addressed using the 8 way dip switch OR Softly addressed using our handheld MKII Programmer part no. 48-004Equipped with short circuit line isolatorExtensive front unit indications GBP 54.65 1
Zeta ZT-MSH Zeta Mains Smoke amp Heat Detector with 9V Battery Backup LPCB Approved Zeta ZT-MSH Zeta Mains Smoke Heat Detector with 9V Battery Backup LPCB ApprovedZT-MS ACDC smoke alarms provide smoke detection and alarm functions within a single unit. Advanced electronics in conjunction with a photoelectric smoke sensing chamber provide early detection of smoke and high immunity against unwanted alarms.ZT-MS ACDC smoke alarms are mains powered with battery backup suitable for general residential applications. ZT-MS ACDC smoke alarms provide home owners and installers with an easy-to-install premium solution for life safety and property protection applications.Key FeaturesAudible and visual alarm indicatorsLow battery signalSmoke chamber fault signalAlarm memory featureInterconnection terminalsLPCB approved GBP 29.89 1