Wagner UK-10-0001 3 Amp EN54 Power Supply Unit Wagner UK-10-0001 3 Amp EN54 Power Supply UnitThe UK-10-0001 is a 3 Amp PSU suitable for 2x 12v 12Ah batteries. GBP 235.37 1
Wagner AD-10-5230 Detector Module TT for ProSensnet amp Silent Wagner AD-10-5230 Detector Module TT for ProSensnet SilentThe AD-10-5230 is a detector module TT which has been designed for use with ProSensnet. It features a super high sensitivity four sensitivity levels 0.015 m 0.03 m 0.06 m 0.12 m and supports up to 32 air sampling openings for each detector module.Titanus ProSensnet is Wagners universal air sampling smoke detector for monitoring large areas of up to 6000 m.By combining cutting-edge HPLS light technology with the patented LogicSens smoke development pattern recognition Titanus ProSensnet provides maximum sensitivity and immunity to false alarms at the same time even under tough conditions.The use of a second detector module enables the establishment of dual detector dependency or monitoring of a second independent area.Key FeaturesSensitivity adjustable down to 0.015 light obscurationm in main alarm depending on detector moduleUp to two detector modules with up to three alarm stages each can be evaluatedPrepared for accepting a network card for linking via Ethernet or SNMPUp to 1 x 100 or 2 x 72 air sampling points depending on versionOptional connection of remote display unitsTitanusProSensnet is available in the following versionsStandardCold Storage -F usable at temperatures down to -40 CSilent SL at 23 dB A and up for noise-sensitive areas GBP 1241.58 1
Wagner AD-05-5200 Housing for TITANUS Accessories Wagner AD-05-5200 Housing for TITANUS AccessoriesThe AD-05-5200 is a Housing Unit designed for use with Titanus accessories. GBP 138.97 1
Wagner AD-05-4820 Bargraph for Titanus RackSens Wagner AD-05-4820 Bargraph for Titanus RackSensThe AD-05-4820 is a Bargraph which has been designed for use with the Titanus RackSens. GBP 353.58 1
Wagner AD-05-0530 Extension Kit for IP52 Rating Wagner AD-05-0530 Extension Kit for IP52 RatingThe AD-05-0530 is an Extension Kit for IP52 rating. It is designed for use with Wagners range of standard aspirating systems. GBP 118.27 1
Wagner AD-05-4800 Mains Supply for Titanus RackSens Wagner AD-05-4800 Mains Supply for Titanus RackSensThe AD-05-4800 is a Mains Supply for use with the Titanus RackSens. GBP 877.52 1
Wagner AD-05-5035 Temperature Sensor for Titanus RackSens Wagner AD-05-5035 Temperature Sensor for Titanus RackSensThe AD-05-5035 Temperature Sensor has been designed for use with the Titanus RackSens. GBP 77.24 1
Wagner AD-05-4810 Temperature-Module for Titanus RackSens Wagner AD-05-4810 Temperature-Module for Titanus RackSensThe AD-05-4810 is a Temperature-Module which has been designed for use with the Titanus RackSens. GBP 353.58 1
Wagner AD-05-2000 Response Alarm Indicator for RackSENS Wagner AD-05-2000 Response Alarm Indicator for RackSENSThe AD-05-2000 is a Response Alarm Indicator which has been designed for use with the Wagner RackSENS air sampling smoke detector. GBP 80.22 1
Wagner AD-10-5250 Detector Module TT f. Pro Sensnet amp SILENT Wagner AD-10-5250 Detector Module TT f. Pro Sensnet SILENTTITANUS PROSENSnet is WAGNERs universal air sampling smoke detector for monitoring large areas of up to 6000 m.By combining cutting-edge HPLS light technology with the patented LOGICSENSsmoke development pattern recognition TITANUS PROSENSnet provides maximum sensitivity and immunity to false alarms at the same time even under tough conditions.The use of a second detector module enables the establishment of dual detector dependency or monitoring of a second independent area.Key FeaturesSensitivity adjustable down to 0.015 light obscurationm in main alarm depending on detector moduleUp to two detector modules with up to three alarm stages each can be evaluatedPrepared for accepting a network card for linking via Ethernet or SNMPUp to 1 x 100 or 2 x 72 air sampling points depending on versionOptional connection of remote display unitsTITANUS PROSENSnet is available in the following versionsStandardCold Storage -F usable at temperatures down to -40 CSilent SL at 23 dB A and up for noise-sensitive areas GBP 442.70 1
Wagner AD-10-5210 Detector Module TT f. Pro Sensnet amp SILENT Wagner AD-10-5210 Detector Module TT f. Pro Sensnet SILENTTITANUS PROSENSnet is WAGNERs universal air sampling smoke detector for monitoring large areas of up to 6000 m.By combining cutting-edge HPLS light technology with the patented LOGICSENSsmoke development pattern recognition TITANUS PROSENSnet provides maximum sensitivity and immunity to false alarms at the same time even under tough conditions.The use of a second detector module enables the establishment of dual detector dependency or monitoring of a second independent area.Key FeaturesSensitivity adjustable down to 0.015 light obscurationm in main alarm depending on detector moduleUp to two detector modules with up to three alarm stages each can be evaluatedPrepared for accepting a network card for linking via Ethernet or SNMPUp to 1 x 100 or 2 x 72 air sampling points depending on versionOptional connection of remote display unitsTITANUS PROSENSnet is available in the following versionsStandardCold Storage -F usable at temperatures down to -40 CSilent SL at 23 dB A and up for noise-sensitive areas GBP 621.89 1
Wagner AD-05-0462 Basic Device Pro Sens net 2 Alarm per Detector Wagner AD-05-0462 Basic Device Pro Sens net 2 Alarm per DetectorTITANUS PROSENSnet is WAGNERs universal air sampling smoke detector for monitoring large areas of up to 6000 m.By combining cutting-edge HPLS light technology with the patented LOGICSENSsmoke development pattern recognition TITANUS PROSENSnet provides maximum sensitivity and immunity to false alarms at the same time even under tough conditions.The use of a second detector module enables the establishment of dual detector dependency or monitoring of a second independent area.Key FeaturesSensitivity adjustable down to 0.015 light obscurationm in main alarm depending on detector moduleUp to two detector modules with up to three alarm stages each can be evaluatedPrepared for accepting a network card for linking via Ethernet or SNMPUp to 1 x 100 or 2 x 72 air sampling points depending on versionOptional connection of remote display unitsTITANUS PROSENSnet is available in the following versionsStandardCold Storage -F usable at temperatures down to -40 CSilent SL at 23 dB A and up for noise-sensitive areas GBP 1263.40 1
Wagner AD-10-0550 Test Pipe For Air Sampling Systems Wagner AD-10-0550 Test Pipe For Air Sampling SystemsA Test Pipe designed for Wagner Air Sampling Systems. GBP 85.15 1
Wagner 01-10-9330 Marking Tape for Aspiration-Reducing Film Wagner 01-10-9330 Marking Tape for Aspiration-Reducing FilmThe 01-10-9330 is a Marking Tape designed for aspiration-reducing film. GBP 1.19 1
Wagner AD-10-0330 Replacement Filter Element for LF-AD Filter Wagner AD-10-0330 Replacement Filter Element for LF-AD FilterTheWagner LF-AD-E is a replacement filter element for the LF-AD filter for the Wagner ASD aspirator range.Key FeaturesDesigned for use with LF-AD Filter GBP 57.67 1
Wagner AD-05-4700 Titanus RackSens 1U - 0.50m Sensitivity Wagner AD-05-4700 Titanus RackSens 1U - 0.50m SensitivityThe Titanus RackSens is Wagners air sampling smoke detector for monitoring 19 equipment such as server and control cabinets. The fire detection unit can also be expanded to include fire suppression using either integrated or externally attached extinguishing gas cylinders. Ten air sampling points provide cost-effective false alarm-proof monitoring of up to five server cabinets. This special fire detector is available in two different installation heights one or two U and using either NovecTM or nitrogen as its extinguishing gas.A three-stage safety concept provides a combination of early fire detection and fire suppression.The earliest possible high-sensitivity smoke detection - Minimise fire damage by getting a maximum head start.Automatic system shut down - Withdrawal of necessary support energy required to prevent fires from spreading and data backup via soft shutdown or virtual server management live migration.Optimised gas extinguishing - Targeted extinguishing at the exact source of the fire.Key FeaturesThe Titanus RackSens combines fire detection and suppression into a single unit 88.9 mm construction height 2UThanks to HPLS light source technology this air sampling smoke detector reaches sensitivity levels of 0.1 obs.m making it up to 400 times more sensitive than conventional smoke detectorsProven Logic.Sens fire pattern recognition technology provides excellent security against false alarmsA second detector module can also be incorporated into a dual detector dependency configuration each with two alarm stages providing maximum flexibility in system response behaviourMaintenance and interactive diagnostics can be performed without interrupting operationsA network interface card slot allows central monitoring remote diagnostics and remote maintenance via Ethernet SNMP GBP 2103.90 1
Wagner AD-05-4705 Titanus RackSens 1U - 0.10m Sensitivity Wagner AD-05-4705 Titanus RackSens 1U - 0.10m SensitivityThe Titanus RackSens is Wagners air sampling smoke detector for monitoring 19 equipment such as server and control cabinets. The fire detection unit can also be expanded to include fire suppression using either integrated or externally attached extinguishing gas cylinders. Ten air sampling points provide cost-effective false alarm-proof monitoring of up to five server cabinets. This special fire detector is available in two different installation heights one or two U and using either NovecTM or nitrogen as its extinguishing gas.A three-stage safety concept provides a combination of early fire detection and fire suppression.The earliest possible high-sensitivity smoke detection - Minimise fire damage by getting a maximum head start.Automatic system shut down - Withdrawal of necessary support energy required to prevent fires from spreading and data backup via soft shutdown or virtual server management live migration.Optimised gas extinguishing - Targeted extinguishing at the exact source of the fire.Key FeaturesThe Titanus RackSens combines fire detection and suppression into a single unit 88.9 mm construction height 2UThanks to HPLS light source technology this air sampling smoke detector reaches sensitivity levels of 0.1 obs.m making it up to 400 times more sensitive than conventional smoke detectorsProven Logic.Sens fire pattern recognition technology provides excellent security against false alarmsA second detector module can also be incorporated into a dual detector dependency configuration each with two alarm stages providing maximum flexibility in system response behaviourMaintenance and interactive diagnostics can be performed without interrupting operationsA network interface card slot allows central monitoring remote diagnostics and remote maintenance via Ethernet SNMP GBP 2806.93 1
Wagner AD-05-4840 Novec Extension Cylinder for 2U RackSens Wagner AD-05-4840 Novec Extension Cylinder for 2U RackSensThe AD-05-4840 is a Novec Extension Cylinder which has been designed for use with the 2U RackSens. GBP 1048.87 1
Wagner AD-10-0335 Filter Element For LF-AD-10 Wagner AD-10-0335 Filter Element For LF-AD-10The AD-10-0335 from the Wagner range of products is a filter element designed for use with the Wagner LF-AD-10 air filter. GBP 59.70 1
Wagner AD-10-0332 Filter Element For LF-AD-2 Wagner AD-10-0332 Filter Element For LF-AD-2The AD-10-0332 from the Wagner range of products is a filter element designed for use with the Wagner LF-AD-2 air filter. GBP 95.52 1
Wagner AD-05-0485 Connection Kit For Pro Sens Base Unit Wagner AD-05-0485 Connection Kit For Pro Sens Base UnitThe Wagner AD-05-0485 is a connection kit designed for use with the Pro Sens Base Unit. GBP 80.62 1
Wagner 1660292 Network Card - Titanus Top Sens and Datalogger for TPnet Wagner 1660292 Network Card - Titanus Top Sens and Datalogger for TPnetThe 1660292 is a Network Card and Datalogger which has been designed for use with the Titanus TopSens TPnet. GBP 522.85 1
Wagner AD-05-4710 Titanus RackSens 2U - 0.50m Sensitivity cw Integral Novec 1230 Extinguishant Wagner AD-05-4710 Titanus RackSens 2U - 0.50m Sensitivity comes with Integral Novec 1230 ExtinguishantThe Titanus RackSens is Wagners air sampling smoke detector for monitoring 19 equipment such as server and control cabinets. The fire detection unit can also be expanded to include fire suppression using either integrated or externally attached extinguishing gas cylinders. Ten air sampling points provide cost-effective false alarm-proof monitoring of up to five server cabinets. This special fire detector is available in two different installation heights one or two U and using either NovecTM or nitrogen as its extinguishing gas.A three-stage safety concept provides a combination of early fire detection and fire suppression.The earliest possible high-sensitivity smoke detection - Minimise fire damage by getting a maximum head start.Automatic system shut down - Withdrawal of necessary support energy required to prevent fires from spreading and data backup via soft shutdown or virtual server management live migration.Optimised gas extinguishing - Targeted extinguishing at the exact source of the fire.Key FeaturesThe Titanus RackSens combines fire detection and suppression into a single unit 88.9 mm construction height 2UThanks to HPLS light source technology this air sampling smoke detector reaches sensitivity levels of 0.1 obs.m making it up to 400 times more sensitive than conventional smoke detectorsProven Logic.Sens fire pattern recognition technology provides excellent security against false alarmsA second detector module can also be incorporated into a dual detector dependency configuration each with two alarm stages providing maximum flexibility in system response behaviourMaintenance and interactive diagnostics can be performed without interrupting operationsA network interface card slot allows central monitoring remote diagnostics and remote maintenance via Ethernet SNMP GBP 4501.02 1
Wagner AD-05-4715 Titanus RackSens 2U - 0.10m Sensitivity cw Integral Novec 1230 Extinguishant Wagner AD-05-4715 Titanus RackSens 2U - 0.10m Sensitivity comes with Integral Novec 1230 ExtinguishantThe Titanus RackSens is Wagners air sampling smoke detector for monitoring 19 equipment such as server and control cabinets. The fire detection unit can also be expanded to include fire suppression using either integrated or externally attached extinguishing gas cylinders. Ten air sampling points provide cost-effective false alarm-proof monitoring of up to five server cabinets. This special fire detector is available in two different installation heights one or two U and using either NovecTM or nitrogen as its extinguishing gas.A three-stage safety concept provides a combination of early fire detection and fire suppression.The earliest possible high-sensitivity smoke detection - Minimise fire damage by getting a maximum head start.Automatic system shut down - Withdrawal of necessary support energy required to prevent fires from spreading and data backup via soft shutdown or virtual server management live migration.Optimised gas extinguishing - Targeted extinguishing at the exact source of the fire.Key FeaturesThe Titanus RackSens combines fire detection and suppression into a single unit 88.9 mm construction height 2UThanks to HPLS light source technology this air sampling smoke detector reaches sensitivity levels of 0.1 obs.m making it up to 400 times more sensitive than conventional smoke detectorsProven Logic.Sens fire pattern recognition technology provides excellent security against false alarmsA second detector module can also be incorporated into a dual detector dependency configuration each with two alarm stages providing maximum flexibility in system response behaviourMaintenance and interactive diagnostics can be performed without interrupting operationsA network interface card slot allows central monitoring remote diagnostics and remote maintenance via Ethernet SNMP GBP 4645.42 1
Wagner AD-05-4815 Additional Detector for Titanus RackSens - 050m Sensitivity Wagner AD-05-4815 Additional Detector for Titanus RackSens - 050m SensitivityThe AD-05-4815 is an additional detector designed for use with the Titanus RackSens - 050m sensitivity.The Titanus RackSens is Wagners air sampling smoke detector for monitoring 19 equipment such as server and control cabinets. The fire detection unit can also be expanded to include fire suppression using either integrated or externally attached extinguishing gas cylinders.Key Features050m sensitivity GBP 558.60 1