9 results (0,16053 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

Vox Ignis ViLX-IPA2 Lexicomm IP66 Weatherproof Type A Fire Telephone

Vox Ignis ViLX-IPA2-GS Lexicomm Weatherproof Type A Steward Phone With Hinged Door

Lexicomm ViLX-OSR Roaming Handset with Jack Plug

Lexicomm ViLX-OSA-GS Surface Type A Fire Telephone Handset - Green - Ral 6001

Lexicomm ViLX-OSJ Jack Point on a Single Gang Plate

Lexicomm ViLX-OSA Surface Type A Fire Telephone Handset

Vox Ignis VILX-OSB-SS Lexicomm Type B Refuge Point Stainless Steel

Lexicomm ViLX-IPB IP66 Weatherproof Type B Refuge Point

Lexicomm ViLX-IPB IP66 Weatherproof Type B Refuge Point

Lexicomm ViLX-IPB IP66 Weatherproof Type B Refuge PointThe ViLX-IPB is a type B EVCS outstation for use in outdoor or exposed areas and is compatible with the Lexicomm standalone and network EVCS systems. The outstation is supplied within an compact IP65 enclosure which is externally signed as required by Building Regulations Approved Document B. The enclosure is opened by operation of a lever lock exposing the handsfree unit and operating instructions.All Lexicomm Emergency Voice Communications Systems EVCS are designed to comply fully with the requirements of BS5839-92011 for use as a fire telephone system FT disabled refuge system DRS or as a combined system when both fire telephones and disabled refuge call points are required.An EVCS is a fixed secure bi-directional full duplex voice communication system to assist fire fighters during emergencies in high rise buildings or large sites where radio communication cannot be guaranteed to work due to interference from the fire corona. BS5839-92011 covers the design installation and operation of fire telephones and disabled refuge systems in buildings and where both systems are fitted to a building the standard specifies these should form a single system.Key FeaturesIP65 cased Hands free full duplex operationSurface mountFully Monitored to BS5839-92011Braille enhanced Call ButtonStandards compliant signage integrated in designRed status LEDSuitabilityThe ViLX-IPB is a Type B outstation as defined in BS5839-92011 and is designed to be used by the public as a disabled refuge call point in outdoor environments. Type B outstations should be placed in disabled refuge locations as described in Building Regulations Approved Document B and BS99992017.Mounting the UnitThe ViLX-IPB unit should be mounted at a height of 900mm to 1200mm from the centre line to the finished floor level to comply with the requirements of Building Regulations Document M Access for the Disabled. When drilling any holes for cable access ensure any bare metal is treated with an antioxidant primer and all cable glands meet IP65 and are correctly tightened. Ensure all mounting holes have the screw seals correctly fitted failure to ensure this will compromise the IP rating of the enclosure.

GBP 304.50
1

Lexicomm ViLX-228-0 Evacuation Voice Communication Master Station

Lexicomm ViLX-228-0 Evacuation Voice Communication Master Station

Lexicomm ViLX-228-0 Evacuation Voice Communication Master StationThis ViLX-228-0 is a Lexicomm master station to be used as a repeater and is supplied in a wall mount enclosure with space for batteries 2 x 12v 7AH VRSLA Not Supplied. Built in network allows for a master slave system or can be connected as a local master station as part of a 64 panel Lexicomm Network system for larger network projects. 8x front panel buttons with PGB LEDs and 7 status LEDs can be expanded to up to 8 lines using ViLX-LC2. This unit fully complies to BS5839 part 9 2011.The Lexicomm ViLX-228 Master station can accept up to eight lines of outstation type A fixed phones type B refuge hands free points emergency assist call point or jack points in Far East and Middle East applications as required. Lines auto identify by flashing Red for EVCS calls Blue for assist calls or flashing Green for Connected calls as detailed in BS5839pt92011 Assist Calls can be acknowledged by pressing the zone key as required by BS8300 and will return to alarm if not reset within two minutes.The case is made from powder coated zintec with a smoked perspex door covering the handset. 20mm cable knock-outs are provided for all necessary cables as well as space for the backup 12V 7AH VRSLA battery. The repeater station is microprocessor controlled it has an identical appearance to a LX228 master station and can control a maximum of 8 lines. Lines auto identify by flashing Red for EVCS calls Blue for assist calls or flashing Green for Connected calls as detailed in BS5839pt92011.The ViLX228 has inbuilt networking allowing it to form one of the 64 panels on a Lexicomm network installation or allowing a repeater using another ViLX228 where buildings have two points of control. Starting at two lines he ViLX228 is ideal for small buildings which are required to have an EVCS but which have a limited number of outstations.All Lexicomm Emergency Voice Communications Systems EVCS are designed to comply fully with the requirements of BS5839-92011 for use as a fire telephone system FT disabled refuge system DRS or as a combined system when both fire telephones and disabled refuge call points are required. An EVCS is a fixed secure bi-directional full duplex voice communication system to assist fire fighters during emergencies in high rise buildings or large sites where radio communication cannot be guaranteed to work due to interference from the fire corona.Key FeaturesCompact DesignFully Compliant to BS5839-9 2011Integrated Assist Call and acknowledge meeting BS83001.5A EN54-4A2 PSUFull Duplex operationWall mount enclosureLockable handset coverExpandable from 2 to 8 linesInbuilt networkingOptional Stainless right hand fascia is available for the ViLX-228 and ViLX-TSM controllers please choose from Drop-Down box.

GBP 816.94
1