Vesda Xtralis Calibration and Flow Cap for VEA XCL-VEA-CAL Vesda Xtralis Calibration and Flow Cap for VEA XCL-VEA-CALVesda Xtralis Sesnsepoint Calibration and Flow Cap for VEA. GBP 86.89 1
Vesda Xtralis Discreet Clear End Cap for 10mm OD Tube Pack of 10 Vesda Xtralis Discreet Clear End Cap for 10mm OD Tube Pack of 10Vesda Xtralis Capillary 10mm Discreet Endcap - with over 250000 aspirating smoke detectors installed worldwide the VESDA name has become synonymous with high quality and outstanding performance. An aspirating smoke detection system however only performs at its best with a well designed and installed quality pipework system. Xtralis manufacturer of VESDA detectors recognised this requirement and in 1997 launched its VESDA Pipe and Fittings range.Please note The 222-059 is equivalent to the REDCAP010N. GBP 5.22 1
Vesda Xtralis VLI-885 LaserINDUSTRIAL Detector with Relays VESDAnet and Ethernet Vesda Xtralis VLI-885 LaserINDUSTRIAL Detector with Relays VESDAnet and EthernetThe VESDA VLI by Xtralis is an industry first early warning aspirating smoke detection ASD system designed to protect industrial applications and harsh environments of up to 2000m2 20000 sq. ft..The VLI detector combines a fail-safe Intelligent Filter patent pending with an advanced clean-air barrier for optics protection allowing the use of absolute detection and a long detection chamber life without the need for recalibration.The Intelligent Filtereffectively reduces the level of pollution in the air sample before it enters the detection chamber which dramatically extends the operational life of the detector in harsh and polluted environments.is fully monitored therefore providing consistent sensitivity over the entire operational life of the detector.The VLI detector features a robust IP54-rated enclosure which provides protection against dust ingress and water splash. In the majority of applications this eliminates the need to use expensive external IP enclosures thus simplifying and reducing the cost of installation. The VLI detector is equipped with a powerful aspirator that provides a total pipe length of 360m 1200 ft. It is fully supported by the Xtralis ASPIRE2 VSC and VSM4 software applications which facilitate ease of pipe network design system commissioning and maintenance together with compatibility with existing VESDA installations.The AutoLearn commissioning assistant reduces setup time and ensures optimum alarm and flow thresholds in a range of environments. The VLI detector features a standardised industry BACnet over Ethernet communication protocol for remote monitoring and programming and connection to building management systems BMS and automation devices. This translates to direct cost savings on integration and monitoring. The VLI detector is inherently less prone to nuisance alarms due to the intelligent filter lint trap sub-sampling probe and secondary filter. Coupled with its modular design VLI offers a lower total cost of ownership over the life of the product.Key FeaturesSuitable for Class 1 Division 2 applications - Groups ABC DUp to 2000m2 20000 sq. ft. coverageUp to 4 inlet pipesTotal pipe length up to 360m 1200 ftFive 5 high intensity status LEDs for greater visibilityRobust absolute smoke detectionIntelligent Filter patent pendingLint Trap to capture fibrous particulatesSub-sampling Probe inertial separatorSecondary FilterClean air barrier for optics protectionReferencingAutoLearn Smoke and FlowClean Air ZeroAir-path monitoringFive 5 relays Fire Fault and 3 configurableRelays configurable as latching or nonlatchingExpandable GPI and relaysUltrasonic flow sensingXtralis VSC Xtralis VSM4 and ASPIRE2 software supportIP54 EnclosureEasy mounting through steel support bracketModular field replaceable parts for ease of servicingBACnet over EthernetLocal USB configuration portEasy cable termination accessImperial and metric pipe portsRubberized finish to external housing GBP 6726.62 1
Vesda Xtralis PIP-015 Flush Sample Point Head Only for 10mm OD Tube Vesda Xtralis PIP-015 Flush Sample Point Head Only for 10mm OD TubeDue to the aesthetic design of some buildings such as ornate ceilings or ceiling art-work a discreet unobtrusive smoke detection system is often desirable. Large open atria or voids feature stratified thermal layers that can prevent cooled smoke from reaching ceiling level. As such conventional systems will normally only respond when a fully-fledged fire condition is reached by which time significant damage has already occurred.VESDA provides the discreet detection required in heritage buildings by routing the sampling pipes in areas that are not visible from normal occupancy. Small-bore capillary pipes are used to provide detection at the required location. The room fabric often dictates the location of these capillary tubes. Hiding the capillary tubes behind light fittings blending in with ceiling paintings or forming part of the ceiling sculptures can all be used to provide invisible smoke detection. In high volume atria applications such as cathedrals capillary sample points can be routed into the area at intermediate vertical levels to good effect to overcome stratification. The higher potential sensitivity of the VESDA system means that less smoke is required at the sample points to provide an alarm condition.With over 250000 aspirating smoke detectors installed worldwide the VESDA name has become synonymous with high quality and outstanding performance. An aspirating smoke detection system however only performs at its best with a well designed and installed quality pipework system. Xtralis manufacturer of VESDA detectors recognised this requirement and in 1997 launched its VESDA Pipe and Fittings range.Key FeaturesFor use with Red or White ABSOperating temperature range -40C to 70CLPCB approvedEN54 testedApplications Used inChurchesHospitalsMuseums GalleriesPrisonsLibrariesArchivesConcert HallsPlease Note The PIP-015 is equivalent to the REDASP025F. GBP 9.07 1
Vesda 020-052 19quot Enclosure for Sub-Rack 2 Rows Vesda 020-052 19 Enclosure for Sub-Rack 2 RowsTo compliment the VESDA range of detectors displays and programmers a 19 inch Subrack enclosure is available. The 19 inch rack enclosure is designed to house up to 12 display andor programmer modules VESDAnet sockets or relay only modules in a wide variety of configurations to suit the particular requirements of a site where centralized control and monitoring of the VESDA system is required.19 Subracks can be installed in glass fronted enclosures and are mounted on a swing frame for convenient connection of all the cables. Cable entry for 24 VDC power VESDAnet connection and interfacing to the relays is provided by multiple knock-outs on all four sides of the box. 19 Subracks and blank panels must be ordered separately. Each enclosure will accommodate up to 3 subracks. If utilising only 1 or 2 racks the VESDA Power Supply VPS-100-US-xxx can also be mounted in the enclosure.A detector enclosure is also available which incorporates a small glass window to view an on-board display. The detector enclosure enables a single detector to be installed in challenging environments where a high IP rating is required.Key FeaturesDual hinged glass door provides easy access to VESDA modules and termination boardsSecond door provides access to the termination boardsDesigned for easy mountingMultiple knock-outs for easy cable entryHolds up to 3 subracksFull size lockable window and door GBP 2037.12 1
Vesda Xtralis VRT-E00 Remote Mount Relays for VLS 7 Relays Vesda Xtralis VRT-E00 Remote Mount Relays for VLS 7 RelaysTheVesda Xtralis LaserSACNNER Remote Relay Module is a VESDAnet ready programmable relay module and enclosure.Includes blank plate with a remote mounting box. 7 Relays version for VLS. GBP 769.24 1
Vesda Xtralis REDSTW100 Smoke Test Wire 100m Vesda Xtralis REDSTW100 Smoke Test Wire 100m100m of test wire designed for wire burn testing.Hot Wire TestThere are a number of tests that can be used to commission a VESDA system. For data centres a hot wire test is best this test is based on 1 metre of test wire with a high electric load passing through it. As the wire heats and the insulation melts the VESDA detector will respond.Please note The REDSTW100 is equivalent to the 251-001. GBP 34.58 1
Vesda Xtralis Smoke Test Wire 100m 251-001 Vesda Xtralis Smoke Test Wire 100m 251-001100m of test wire designed for wire burn testing.Hot Wire TestThere are a number of tests that can be used to commission a VESDA system. For data centres a hot wire test is best this test is based on 1 metre of test wire with a high electric load passing through it. As the wire heats and the insulation melts the VESDA detector will respond.Please note The 251-001 is equivalent to the REDSTW100. GBP 34.58 1
Vesda Xtralis 020-055 19quot Enclosure for Sub-Rack 5 Rows Vesda Xtralis 020-055 19 Enclosure for Sub-Rack 5 Rows19 Subrack and Detector Enclosures to complement the VESDA range of detectors displays and programmers a range of glass fronted enclosures are available.The 19-inch rack enclosures are designed to house up to 20 display and programmer modules in a wide variety of configurations to suit the particular requirements of a site where centralised control and monitoring of the VESDA system is required. Two versions are available 2 rack up to 8 Modules and 5 rack up to 20 Modules.19 Subracks ordered separately as VSR-xxxx are mounted on a swing frame for convenient connection of all the cables. Cable entry for 24VDC power VESDAnet connection and interfacing to the relays is provided by a removable gland plate which is drilled as required on site. 19 Subracks and 3U blank panels must be ordered separately.Detector or single remote display EnclosureA detector enclosure is also available which incorporates a small glass window to view an on-board display.This detector enclosure enables a single detector or remote module to be installed in challenging environments where a high IP rating is required.The enclosure can accommodate a single VESDA VLP VESDA VLS VESDA VLC or VESDA VLF detector or a single remote module such as a VRT-200. It is supplied with all appropriate cable and pipe entries pre-drilled for each device and enough plugs to blank off those holes not used.A kit of pipe fittings and instructions is supplied to ensure that the IP rating of the enclosure is maintained but cable glands are NOT supplied as they depend on the cable to be used. GBP 2294.89 1
Xtralis OSE-ACF OSID Anti-Condensation Film for Emitter Pack of 10 Xtralis OSE-ACF OSID Anti-Condensation Film for Emitter Pack of 10Pack of 10 anti-condensation films designed for OSID Emitters.Emitters are equipped with an acrylic lens and are therefore not normally prone to condensation. However in some extremely moist environments condensation may nevertheless occur on the lens. Slow forming condensation can produce an unacceptably large loss of signal. To prevent that from occurring the Emitter lens can be fitted with an anti-condensation film. The film can be quickly and easily applied to the lens without the need for special tools or adhesives.The film prevents condensation from forming and keeps the lens clear. Note however that the film causes a 10 reduction in maximum detection distance. A damp cloth can be used to clean the film if it becomes contaminated. The combination of the film and the algorithms in the Imager offer a cost-effective solution for condensation susceptible areas. The OSID Imager has a built-in heater and the film should not be used on Imagers.In harsh environments where the OSID-EH environmental housings are used and condensation is expected both Emitter and Imager housing can be fitted with an anti-condensation film. When applied on Emitter and Imager housing there is a 20 reduction in maximum detection distance.Key FeaturesPrevents condensationFast and easy installationSimple maintenanceLong lifetimeHighly scratch resistantDoes not crack peel or discolour from exposure to sunlightEasy to clean using cleaning solvents GBP 184.85 1
Vesda VIC-010 VESDAnet Card for VLF-250 amp VLF-500 Vesda VIC-010 VESDAnet Card for VLF-250 VLF-500The VESDAnet Interface Card VN Card is a simple to install plug-in interface card for the range of VESDA LaserFOCUS VLF-250 and VLF-500 smoke detectors. The VN card provides seamless VESDAnet communication from the detector to VESDAnet devices and configuration and monitoring tools.What is VESDAnetVESDAnet is the comprehensive fault tolerant proprietary VESDA communications protocol. VESDAnet links the VESDA range of detectors displays programmers and remote units on the one network or remotely to enable sophisticated configuration monitoring and control from local or remote sites. Using a VESDA High Level Interface HLI VESDAnet also interfaces with systems external to the network such as building management systems and Fire Alarm Control Panels. Using a VESDA configuration tool such as VESDA System Configurator VSC or an LCD Programmer users can view and administer all devices via VESDAnet. The VN Card can be configured through the VESDA detector via its RS-232 Serial port or from the VESDAnet using VSC.Key FeaturesProvides seamless VESDAnet fault-tolerant communicationQuick and simple to installMinimal configuration requiredDiagnostic LEDs give visual indication of the cards statusFully transferrable between Xtralis VESDA VLF detectors GBP 355.75 1
Vesda Xtralis VSP-025 Filter Cartridge for VLP VLS VLC amp VLF Pack of 20 Vesda Xtralis VSP-025 Filter Cartridge for VLP VLS VLC VLF Pack of 20The VSP-025 is a VESDA replacement filter cartridge VSP-005 for single units and VSP-025 for a pack of 20 is used to replace filter cartridges in VESDA LaserCOMPACT LaserFOCUS LaserPLUS and LaserSCANNER detectors. One model fits all detectors.Key FeaturesEasy swap replacement filterFits VLC VLF VLP and VLS VESDA detectorsAvailable singly or in packs of 2090 mm x 63 mm x 30 mm 3.5 in. x 2.5 in. x 1.2 in.Two Stage FiltrationFirst stage removes particles in excess of 20 micronsSecond stage is ultra-fine and removes more than 99 of particles of 0.3 microns or larger to provide a clean air barrier for optics protection GBP 1392.68 1
Vesda VRT-500 Remote Mount Relays for VLP VLS amp VLC with 7 Relays Vesda VRT-500 Remote Mount Relays for VLP VLS VLC with 7 RelaysVRT-500 is a Remote Mount Relay Module designed for use with VLP VLS and VLC detectors.Key Features7 relaysIncludes blank plate with a remote mounting box GBP 725.50 1
Vesda VHX-0410 Modbus HLI for Darwish amp Honeywell Only Vesda VHX-0410 Modbus HLI for Darwish Honeywell OnlyThe VESDA ModBus High Level Interface HLI links your VESDAnet with PC software monitoring tools Building Management Systems BMSs or Fire Alarm Control Panels FACPs otherwise known as host that support the ModBus protocol. There are two models availableModBus HLI Type 1 VHX-0400 which echoes each character received on the RS232 link back to the host together with reply message.ModBus HLI Type 2 VHX-0410 which has the echoing function disabled.Key FeaturesDirect access and monitoring of your VESDAnet system.Seamless data transfer.Easily configured using Xtralis configuring and monitoring software packages.DescriptionOne ModBus HLI is used to interface to a VESDAnet. Modbus HLI supports up to a maximum of 40 VESDA detectors on a VESDAnet.The Modbus HLI supports VESDAnet detector zone numbers between 1 to 200. The Modbus HLI divides up the address range into to 7 logical networks. For example the first 30 addresses are considered in network 1 addresses between 31 to 60 are in network 2 and so on.Smoke and Alarm LevelsThe Smoke Level is reported relative to the Fire Alarm threshold where the full scale is 20. For example if the Fire Alarm threshold is 0.5 obsm a level of 0.1obsm is reported as 4. In other words the Actual Smoke level Reported smoke value Fire1 Threshold 20.FaultsAll VESDAnet faults are mapped on one or more of the Modbus HLI faults which are listed belowHead FaultHead Fault Battery and MainsHead Fault Scanner2 and Flow FaultVESDAnet faults categorised as network faults are mapped onto all zones whereas zone faults are mapped onto that particular zone. GBP 1328.53 1
Xtralis OSEH-ACF OSID Anti-Condensation Film for OSID-EH Housings Pack of 10 Xtralis OSEH-ACF OSID Anti-Condensation Film for OSID-EH Housings Pack of 10Anti-condensation film for OSID-EH environmental housings. An easy applicable film that provides condensation resistance for the lenses of OSID Environmental Housings.OSID Emitters are equipped with an acrylic lens and are therefore not normally prone to condensation. However in some extremely moist environments condensation may nevertheless occur on the lens. Slow forming condensation can produce an unacceptably large loss of signal. To prevent that from occurring the Emitter lens can be fitted with an anti-condensation film. The film can be quickly and easily applied to the lens without the need for special tools or adhesives.The film prevents condensation from forming and keeps the lens clear. Note however that the film causes a 10 reduction in maximum detection distance. A damp cloth can be used to clean the film if it becomes contaminated. The combination of the film and the algorithms in the Imager offer a cost-effective solution for condensation susceptible areas. The OSID Imager has a built-in heater and the film should not be used on Imagers.In harsh environments where the OSID-EH environmental housings are used and condensation is expected both Emitter and Imager housing can be fitted with an anti-condensation film. When applied on Emitter and Imager housing there is a 20 reduction in maximum detection distance.Key FeaturesPrevents condensationFast and easy installationSimple maintenanceLong lifetimeHighly scratch resistantDoes not crack peel or discolour from exposure to sunlightEasy to clean using cleaning solvents GBP 705.35 1
Vesda Xtralis VIC-020 Multi-Fuctional Control Card VLF for VLF-250 amp VLF-500 Vesda Xtralis VIC-020 Multi-Functional Control Card VLF for VLF-250 VLF-500The VESDA VLF MCC Multi-function Control Card is an interface card for the range of Xtralis VESDA VLF smoke detectors. An MCC expands the range of input and output communications a VLF detector can perform.Why use a VLF MCCInstalling a VLF MCC into a VLF detector provides a cost-effective solution for customers who need enhanced connectivity fault detection and monitoring and annunciation of alarms and faults. The principal benefits includeImproved FACP connectivityThe VLF is fitted with two 2 alarm relays in its standard form. With an extra two 2 relays the Multi-function Control Card allows reporting of all four 4 alarm levels on dry relay outputs.Enhanced annunciationAn MPO Monitored 24 V Powered Output is available on the VIC-030 version of the card. The MPO provides power to devices such as sirens or strobes and monitors the line integrity.Enhanced control and fault detectionWith a VLF MCC installed a VLF has two 2 General Purpose Inputs GPIs allowing for example one GPI to report on loss of mains power and the other GPI to be used as a reset input. The VIC-030 version of the card has a self-configuring GPI depending on the jumper selection for MPORelay3.If MPO is selected activation of the GPI will disable the MPO.If Relay3 is selected the GPI will be set to External Fault e.g. for mains power supply monitoring.Key FeaturesProvides two 2 additional relaysProvides an extra General-Purpose Input GPI with line monitoringQuick and simple to installOut-of-the-box operation with minimal configuration required for extra featuresDiagnostic LEDs give visual indication of the cards statusFully compatible with Xtralis VESDA VLF smoke detector GBP 246.11 1
Vesda Xtralis F-PC-5.5 Standard-Clip for ASD Pipework 5.5mm - Pack of 5 Vesda Xtralis F-PC-5.5 Standard-Clip for ASD Pipework 5.5mm - Pack of 5A standard clip for aspirating holes 5.5mm in the colour green.When installing an Aspirating Smoke Detection ASD system it is often almost impossible to identify the exact location of sampling point and more importantly identify if the sampling hole is the correct size creating unnecessary delays.The VESDA Sampling Hole Clip delivers reliable and accurate sampling hole sizes that are fast to install and easy to locate and identify. Each clip is colour-coded to indicate a specific hole diameter providing an instant visual guide and removing the need for closer inspection.This is particularly beneficial during commissioning and maintenance processes in applications like warehouses or large open spaces. The greatly simplified installation process helps deliver greater reliability in the correct setting of sampling hole size and a faster installation process. A 10mm 2764 diameter drill bit is all that is required by an installer to create each sampling hole rather than many different drill sizes to which the Sampling Hole Clip attaches to.This can help deliver quality installation in projects where installation is sub contracted or the installer is not familiar with the impact of sampling hole size. Use of a chamfered hole entry in the sampling hole clip design can help to reduce dust loading effects.Without using this type of technology a build-up of dust around a standard drilled sampling hole is likely to occur due to the friction created by the airflow through the sampling hole. By reducing dust loading effects and leveraging the additional protection provided by the pipe clips sites can help increase system uptime and potentially extend service and testing intervals.Unlike most contemporary solutions the pipe clip is installation-ready with no need for assembly any additional parts or tools clips are provided as a single ready-to-fit piece.The pipe clips are also available in two formats Standard and Harsh Environment. Harsh Environment Clip variants feature a flexi-lip design that changes its shape when subjected to compressed air.This helps any ice fibre or dust build-up on the supporting rubber structure be easily detached and broken up by the air Jetstream out of the clip hole providing additional protection in challenging locations like freezer applications.Key FeaturesPre-engineered sampling holes for faster more efficient commissioning and installationInstallation-ready design with no part assembly or tools required simply clicks into place for a firm non-slip positionVisual colour-coded guide to sampling point location and sampling hole sizeGreatly simplifies sampling hole drilling a single 10mm drill bit for all holes simply fit the relevant clip to set the hole sizeReduces dust loading effects through inclusion of a chamfered hole entry design helping to increase uptime and potentially extends test intervalsTwo formats available Standard and Harsh EnvironmentHarsh Environment Clip variants feature a flexi-lip design to help reduce sampling hole contamination under high air pressure GBP 21.32 1
Vesda Xtralis F-PC-4 Standard-Clip for ASD Pipework 4.0mm - Pack of 5 Vesda Xtralis F-PC-4 Standard-Clip for ASD Pipework 4.0mm - Pack of 5A standard clip for aspirating holes 4.0mm in the colour yellow.When installing an Aspirating Smoke Detection ASD system it is often almost impossible to identify the exact location of sampling point and more importantly identify if the sampling hole is the correct size creating unnecessary delays.The VESDA Sampling Hole Clip delivers reliable and accurate sampling hole sizes that are fast to install and easy to locate and identify. Each clip is colour-coded to indicate a specific hole diameter providing an instant visual guide and removing the need for closer inspection.This is particularly beneficial during commissioning and maintenance processes in applications like warehouses or large open spaces. The greatly simplified installation process helps deliver greater reliability in the correct setting of sampling hole size and a faster installation process. A 10mm 2764 diameter drill bit is all that is required by an installer to create each sampling hole rather than many different drill sizes to which the Sampling Hole Clip attaches to.This can help deliver quality installation in projects where installation is sub contracted or the installer is not familiar with the impact of sampling hole size. Use of a chamfered hole entry in the sampling hole clip design can help to reduce dust loading effects.Without using this type of technology a build-up of dust around a standard drilled sampling hole is likely to occur due to the friction created by the airflow through the sampling hole. By reducing dust loading effects and leveraging the additional protection provided by the pipe clips sites can help increase system uptime and potentially extend service and testing intervals.Unlike most contemporary solutions the pipe clip is installation-ready with no need for assembly any additional parts or tools clips are provided as a single ready-to-fit piece.The pipe clips are also available in two formats Standard and Harsh Environment. Harsh Environment Clip variants feature a flexi-lip design that changes its shape when subjected to compressed air.This helps any ice fibre or dust build-up on the supporting rubber structure be easily detached and broken up by the air Jetstream out of the clip hole providing additional protection in challenging locations like freezer applications.Key FeaturesPre-engineered sampling holes for faster more efficient commissioning and installationInstallation-ready design with no part assembly or tools required simply clicks into place for a firm non-slip positionVisual colour-coded guide to sampling point location and sampling hole sizeGreatly simplifies sampling hole drilling a single 10mm drill bit for all holes simply fit the relevant clip to set the hole sizeReduces dust loading effects through inclusion of a chamfered hole entry design helping to increase uptime and potentially extends test intervalsTwo formats available Standard and Harsh EnvironmentHarsh Environment Clip variants feature a flexi-lip design to help reduce sampling hole contamination under high air pressure GBP 21.32 1
Vesda Xtralis F-PC-2.5 Standard-Clip for ASD Pipework 2.5mm - Pack of 5 Vesda Xtralis F-PC-2.5 Standard-Clip for ASD Pipework 2.5mm - Pack of 5A standard clip for aspirating holes in the colour red 2.5mmWhen installing an Aspirating Smoke Detection ASD system it is often almost impossible to identify the exact location of sampling point and more importantly identify if the sampling hole is the correct size creating unnecessary delays.The VESDA Sampling Hole Clip delivers reliable and accurate sampling hole sizes that are fast to install and easy to locate and identify. Each clip is colour-coded to indicate a specific hole diameter providing an instant visual guide and removing the need for closer inspection.This is particularly beneficial during commissioning and maintenance processes in applications like warehouses or large open spaces. The greatly simplified installation process helps deliver greater reliability in the correct setting of sampling hole size and a faster installation process. A 10mm 2764 diameter drill bit is all that is required by an installer to create each sampling hole rather than many different drill sizes to which the Sampling Hole Clip attaches to.This can help deliver quality installation in projects where installation is sub contracted or the installer is not familiar with the impact of sampling hole size. Use of a chamfered hole entry in the sampling hole clip design can help to reduce dust loading effects.Without using this type of technology a build-up of dust around a standard drilled sampling hole is likely to occur due to the friction created by the airflow through the sampling hole. By reducing dust loading effects and leveraging the additional protection provided by the pipe clips sites can help increase system uptime and potentially extend service and testing intervals.Unlike most contemporary solutions the pipe clip is installation-ready with no need for assembly any additional parts or tools clips are provided as a single ready-to-fit piece.The pipe clips are also available in two formats Standard and Harsh Environment. Harsh Environment Clip variants feature a flexi-lip design that changes its shape when subjected to compressed air.This helps any ice fibre or dust build-up on the supporting rubber structure be easily detached and broken up by the air Jetstream out of the clip hole providing additional protection in challenging locations like freezer applications.Key FeaturesPre-engineered sampling holes for faster more efficient commissioning and installationInstallation-ready design with no part assembly or tools required simply clicks into place for a firm non-slip positionVisual colour-coded guide to sampling point location and sampling hole sizeGreatly simplifies sampling hole drilling a single 10mm drill bit for all holes simply fit the relevant clip to set the hole sizeReduces dust loading effects through inclusion of a chamfered hole entry design helping to increase uptime and potentially extends test intervalsTwo formats available Standard and Harsh EnvironmentHarsh Environment Clip variants feature a flexi-lip design to help reduce sampling hole contamination under high air pressure GBP 21.32 1
Vesda Xtralis F-PC-2 Standard-Clip for ASD Pipework 2.0mm - Pack of 5 Vesda Xtralis F-PC-2 Standard-Clip for ASD Pipework 2.0mm - Pack of 5A standard clip in red for aspirating holes 2.0mm.When installing an Aspirating Smoke Detection ASD system it is often almost impossible to identify the exact location of sampling point and more importantly identify if the sampling hole is the correct size creating unnecessary delays.The VESDA Standard Clip delivers reliable and accurate sampling hole sizes that are fast to install and easy to locate and identify. Each clip is colour-coded to indicate a specific hole diameter providing an instant visual guide and removing the need for closer inspection.This is particularly beneficial during commissioning and maintenance processes in applications like warehouses or large open spaces. The greatly simplified installation process helps deliver greater reliability in the correct setting of sampling hole size and a faster installation process. A 10mm 2764 diameter drill bit is all that is required by an installer to create each sampling hole rather than many different drill sizes to which the Sampling Hole Clip attaches to.This can help deliver quality installation in projects where installation is sub contracted or the installer is not familiar with the impact of sampling hole size. Use of a chamfered hole entry in the sampling hole clip design can help to reduce dust loading effects.Without using this type of technology a build-up of dust around a standard drilled sampling hole is likely to occur due to the friction created by the airflow through the sampling hole. By reducing dust loading effects and leveraging the additional protection provided by the pipe clips sites can help increase system uptime and potentially extend service and testing intervals.Unlike most contemporary solutions the pipe clip is installation-ready with no need for assembly any additional parts or tools clips are provided as a single ready-to-fit piece.The pipe clips are also available in two formats Standard and Harsh Environment. Harsh Environment Clip variants feature a flexi-lip design that changes its shape when subjected to compressed air.This helps any ice fibre or dust build-up on the supporting rubber structure be easily detached and broken up by the air Jetstream out of the clip hole providing additional protection in challenging locations like freezer applications.Key FeaturesPre-engineered sampling holes for faster more efficient commissioning and installationInstallation-ready design with no part assembly or tools required simply clicks into place for a firm non-slip positionVisual colour-coded guide to sampling point location and sampling hole sizeGreatly simplifies sampling hole drilling a single 10mm drill bit for all holes simply fit the relevant clip to set the hole sizeReduces dust loading effects through inclusion of a chamfered hole entry design helping to increase uptime and potentially extends test intervalsTwo formats available Standard and Harsh EnvironmentHarsh Environment Clip variants feature a flexi-lip design to help reduce sampling hole contamination under high air pressure GBP 21.32 1
Vesda Xtralis F-PC-6 Standard-Clip for ASD Pipework 6.0mm - Pack of 5 Vesda Xtralis F-PC-6 Standard-Clip for ASD Pipework 6.0mm - Pack of 5A standard clip for aspirating holes 6.0mm in the colour blue.When installing an Aspirating Smoke Detection ASD system it is often almost impossible to identify the exact location of sampling point and more importantly identify if the sampling hole is the correct size creating unnecessary delays.The VESDA Sampling Hole Clip delivers reliable and accurate sampling hole sizes that are fast to install and easy to locate and identify. Each clip is colour-coded to indicate a specific hole diameter providing an instant visual guide and removing the need for closer inspection.This is particularly beneficial during commissioning and maintenance processes in applications like warehouses or large open spaces. The greatly simplified installation process helps deliver greater reliability in the correct setting of sampling hole size and a faster installation process. A 10mm 2764 diameter drill bit is all that is required by an installer to create each sampling hole rather than many different drill sizes to which the Sampling Hole Clip attaches to.This can help deliver quality installation in projects where installation is sub contracted or the installer is not familiar with the impact of sampling hole size. Use of a chamfered hole entry in the sampling hole clip design can help to reduce dust loading effects.Without using this type of technology a build-up of dust around a standard drilled sampling hole is likely to occur due to the friction created by the airflow through the sampling hole. By reducing dust loading effects and leveraging the additional protection provided by the pipe clips sites can help increase system uptime and potentially extend service and testing intervals.Unlike most contemporary solutions the pipe clip is installation-ready with no need for assembly any additional parts or tools clips are provided as a single ready-to-fit piece.The pipe clips are also available in two formats Standard and Harsh Environment. Harsh Environment Clip variants feature a flexi-lip design that changes its shape when subjected to compressed air.This helps any ice fibre or dust build-up on the supporting rubber structure be easily detached and broken up by the air Jetstream out of the clip hole providing additional protection in challenging locations like freezer applications.Key FeaturesPre-engineered sampling holes for faster more efficient commissioning and installationInstallation-ready design with no part assembly or tools required simply clicks into place for a firm non-slip positionVisual colour-coded guide to sampling point location and sampling hole sizeGreatly simplifies sampling hole drilling a single 10mm drill bit for all holes simply fit the relevant clip to set the hole sizeReduces dust loading effects through inclusion of a chamfered hole entry design helping to increase uptime and potentially extends test intervalsTwo formats available Standard and Harsh EnvironmentHarsh Environment Clip variants feature a flexi-lip design to help reduce sampling hole contamination under high air pressure GBP 21.32 1
Vesda Xtralis F-PC-3.5 Standard-Clip for ASD Pipework 3.5mm - Pack of 5 Vesda Xtralis F-PC-3.5 Standard-Clip for ASD Pipework 3.5mm - Pack of 5A standard clip for aspirating holes 3.0mm in the colour orange.When installing an Aspirating Smoke Detection ASD system it is often almost impossible to identify the exact location of sampling point and more importantly identify if the sampling hole is the correct size creating unnecessary delays.The VESDA Sampling Hole Clip delivers reliable and accurate sampling hole sizes that are fast to install and easy to locate and identify. Each clip is colour-coded to indicate a specific hole diameter providing an instant visual guide and removing the need for closer inspection.This is particularly beneficial during commissioning and maintenance processes in applications like warehouses or large open spaces. The greatly simplified installation process helps deliver greater reliability in the correct setting of sampling hole size and a faster installation process. A 10mm 2764 diameter drill bit is all that is required by an installer to create each sampling hole rather than many different drill sizes to which the Sampling Hole Clip attaches to.This can help deliver quality installation in projects where installation is sub contracted or the installer is not familiar with the impact of sampling hole size. Use of a chamfered hole entry in the sampling hole clip design can help to reduce dust loading effects.Without using this type of technology a build-up of dust around a standard drilled sampling hole is likely to occur due to the friction created by the airflow through the sampling hole. By reducing dust loading effects and leveraging the additional protection provided by the pipe clips sites can help increase system uptime and potentially extend service and testing intervals.Unlike most contemporary solutions the pipe clip is installation-ready with no need for assembly any additional parts or tools clips are provided as a single ready-to-fit piece.The pipe clips are also available in two formats Standard and Harsh Environment. Harsh Environment Clip variants feature a flexi-lip design that changes its shape when subjected to compressed air.This helps any ice fibre or dust build-up on the supporting rubber structure be easily detached and broken up by the air Jetstream out of the clip hole providing additional protection in challenging locations like freezer applications.Key FeaturesPre-engineered sampling holes for faster more efficient commissioning and installationInstallation-ready design with no part assembly or tools required simply clicks into place for a firm non-slip positionVisual colour-coded guide to sampling point location and sampling hole sizeGreatly simplifies sampling hole drilling a single 10mm drill bit for all holes simply fit the relevant clip to set the hole sizeReduces dust loading effects through inclusion of a chamfered hole entry design helping to increase uptime and potentially extends test intervalsTwo formats available Standard and Harsh EnvironmentHarsh Environment Clip variants feature a flexi-lip design to help reduce sampling hole contamination under high air pressure GBP 21.32 1
Vesda Xtralis F-PC-6.5 Standard-Clip for ASD Pipework 6.5mm - Pack of 5 Vesda Xtralis F-PC-6.5 Standard-Clip for ASD Pipework 6.5mm - Pack of 5A standard clip for aspirating holes 6.5mm in the colour blue.When installing an Aspirating Smoke Detection ASD system it is often almost impossible to identify the exact location of sampling point and more importantly identify if the sampling hole is the correct size creating unnecessary delays.The VESDA Sampling Hole Clip delivers reliable and accurate sampling hole sizes that are fast to install and easy to locate and identify. Each clip is colour-coded to indicate a specific hole diameter providing an instant visual guide and removing the need for closer inspection.This is particularly beneficial during commissioning and maintenance processes in applications like warehouses or large open spaces. The greatly simplified installation process helps deliver greater reliability in the correct setting of sampling hole size and a faster installation process. A 10mm 2764 diameter drill bit is all that is required by an installer to create each sampling hole rather than many different drill sizes to which the Sampling Hole Clip attaches to.This can help deliver quality installation in projects where installation is sub contracted or the installer is not familiar with the impact of sampling hole size. Use of a chamfered hole entry in the sampling hole clip design can help to reduce dust loading effects.Without using this type of technology a build-up of dust around a standard drilled sampling hole is likely to occur due to the friction created by the airflow through the sampling hole. By reducing dust loading effects and leveraging the additional protection provided by the pipe clips sites can help increase system uptime and potentially extend service and testing intervals.Unlike most contemporary solutions the pipe clip is installation-ready with no need for assembly any additional parts or tools clips are provided as a single ready-to-fit piece.The pipe clips are also available in two formats Standard and Harsh Environment. Harsh Environment Clip variants feature a flexi-lip design that changes its shape when subjected to compressed air.This helps any ice fibre or dust build-up on the supporting rubber structure be easily detached and broken up by the air Jetstream out of the clip hole providing additional protection in challenging locations like freezer applications.Key FeaturesPre-engineered sampling holes for faster more efficient commissioning and installationInstallation-ready design with no part assembly or tools required simply clicks into place for a firm non-slip positionVisual colour-coded guide to sampling point location and sampling hole sizeGreatly simplifies sampling hole drilling a single 10mm drill bit for all holes simply fit the relevant clip to set the hole sizeReduces dust loading effects through inclusion of a chamfered hole entry design helping to increase uptime and potentially extends test intervalsTwo formats available Standard and Harsh EnvironmentHarsh Environment Clip variants feature a flexi-lip design to help reduce sampling hole contamination under high air pressure GBP 21.32 1
Vesda Xtralis F-PC-5 Standard-Clip for ASD Pipework 5.0mm - Pack of 5 Vesda Xtralis F-PC-5 Standard-Clip for ASD Pipework 5.0mm - Pack of 5A standard clip for aspirating holes 5.0mm in the colour green.When installing an Aspirating Smoke Detection ASD system it is often almost impossible to identify the exact location of sampling point and more importantly identify if the sampling hole is the correct size creating unnecessary delays.The VESDA Sampling Hole Clip delivers reliable and accurate sampling hole sizes that are fast to install and easy to locate and identify. Each clip is colour-coded to indicate a specific hole diameter providing an instant visual guide and removing the need for closer inspection.This is particularly beneficial during commissioning and maintenance processes in applications like warehouses or large open spaces. The greatly simplified installation process helps deliver greater reliability in the correct setting of sampling hole size and a faster installation process. A 10mm 2764 diameter drill bit is all that is required by an installer to create each sampling hole rather than many different drill sizes to which the Sampling Hole Clip attaches to.This can help deliver quality installation in projects where installation is sub contracted or the installer is not familiar with the impact of sampling hole size. Use of a chamfered hole entry in the sampling hole clip design can help to reduce dust loading effects.Without using this type of technology a build-up of dust around a standard drilled sampling hole is likely to occur due to the friction created by the airflow through the sampling hole. By reducing dust loading effects and leveraging the additional protection provided by the pipe clips sites can help increase system uptime and potentially extend service and testing intervals.Unlike most contemporary solutions the pipe clip is installation-ready with no need for assembly any additional parts or tools clips are provided as a single ready-to-fit piece.The pipe clips are also available in two formats Standard and Harsh Environment. Harsh Environment Clip variants feature a flexi-lip design that changes its shape when subjected to compressed air.This helps any ice fibre or dust build-up on the supporting rubber structure be easily detached and broken up by the air Jetstream out of the clip hole providing additional protection in challenging locations like freezer applications.Key FeaturesPre-engineered sampling holes for faster more efficient commissioning and installationInstallation-ready design with no part assembly or tools required simply clicks into place for a firm non-slip positionVisual colour-coded guide to sampling point location and sampling hole sizeGreatly simplifies sampling hole drilling a single 10mm drill bit for all holes simply fit the relevant clip to set the hole sizeReduces dust loading effects through inclusion of a chamfered hole entry design helping to increase uptime and potentially extends test intervalsTwo formats available Standard and Harsh EnvironmentHarsh Environment Clip variants feature a flexi-lip design to help reduce sampling hole contamination under high air pressure GBP 21.32 1
Vesda Xtralis F-PC-3 Standard-Clip for ASD Pipework 3.0mm - Pack of 5 Vesda Xtralis F-PC-3 Standard-Clip for ASD Pipework 3.0mm - Pack of 5A standard-clip for aspirating holes in the colour orange. 3.0mmWhen installing an Aspirating Smoke Detection ASD system it is often almost impossible to identify the exact location of sampling point and more importantly identify if the sampling hole is the correct size creating unnecessary delays.The VESDA Sampling Hole Clip delivers reliable and accurate sampling hole sizes that are fast to install and easy to locate and identify. Each clip is colour-coded to indicate a specific hole diameter providing an instant visual guide and removing the need for closer inspection.This is particularly beneficial during commissioning and maintenance processes in applications like warehouses or large open spaces. The greatly simplified installation process helps deliver greater reliability in the correct setting of sampling hole size and a faster installation process. A 10mm 2764 diameter drill bit is all that is required by an installer to create each sampling hole rather than many different drill sizes to which the Sampling Hole Clip attaches to.This can help deliver quality installation in projects where installation is sub contracted or the installer is not familiar with the impact of sampling hole size. Use of a chamfered hole entry in the sampling hole clip design can help to reduce dust loading effects.Without using this type of technology a build-up of dust around a standard drilled sampling hole is likely to occur due to the friction created by the airflow through the sampling hole. By reducing dust loading effects and leveraging the additional protection provided by the pipe clips sites can help increase system uptime and potentially extend service and testing intervals.Unlike most contemporary solutions the pipe clip is installation-ready with no need for assembly any additional parts or tools clips are provided as a single ready-to-fit piece.The pipe clips are also available in two formats Standard and Harsh Environment. Harsh Environment Clip variants feature a flexi-lip design that changes its shape when subjected to compressed air.This helps any ice fibre or dust build-up on the supporting rubber structure be easily detached and broken up by the air Jetstream out of the clip hole providing additional protection in challenging locations like freezer applications.Key FeaturesPre-engineered sampling holes for faster more efficient commissioning and installationInstallation-ready design with no part assembly or tools required simply clicks into place for a firm non-slip positionVisual colour-coded guide to sampling point location and sampling hole sizeGreatly simplifies sampling hole drilling a single 10mm drill bit for all holes simply fit the relevant clip to set the hole sizeReduces dust loading effects through inclusion of a chamfered hole entry design helping to increase uptime and potentially extends test intervalsTwo formats available Standard and Harsh EnvironmentHarsh Environment Clip variants feature a flexi-lip design to help reduce sampling hole contamination under high air pressure GBP 21.32 1