Scope PZ10 10 Zone Expansion Unit for RX10 Receiver Scope PZ10 10 Zone Expansion Unit for RX10 ReceiverA 10 Zone Expansion Unit for the RX10 Receiver.Requires an external 12v DC amp PSU. GBP 276.12 1
Scope PZ10L 10 Zone Expansion Unit for RX10 Receiver Scope PZ10L 10 Zone Expansion Unit for RX10 ReceiverA 10 Zone Expansion Unit in a large case for the RX10 Receiver.Requires external 12v DC amp PSU. GBP 374.40 1
Scope FLXP30 30 Zone Relay Expansion Unit for F-Link 4 Master Scope FLXP30 30 Zone Relay Expansion Unit for F-Link 4 MasterA 30 zone relay expansion unit for the F-Link 4 Master. GBP 612.14 1
Scope FLXP15 15 Zone Relay Expansion Unit for F-Link 4 Master Scope FLXP15 15 Zone Relay Expansion Unit for F-Link 4 MasterA 15 zone relay expansion unit for the F-Link 4 Master. GBP 406.22 1
Scope F-Link 1224v Fully Monitored Telemetry Transceivers FLINK4KIT Scope F-Link FLINK4KIT 1224v Fully Monitored Telemetry TransceiversThe original Scope F-Link system has become a popular and secure way of remotely alerting and monitoring fire or security panels. The latest version adds even greater performance and improved functionality. F-Link is now housed in a larger case with plenty of cable entry points and an informative text display which provides status information and gives details of alarm messages.A system consists of two or more F-Link units working together to form a mesh network with each unit operating as both a transmitter and receiver. The radio link between units is monitored for faults in accordance with the relevant sections of BS5839-12017 24.2b and BSEN54-252008 4.2.6. There is an additional output on the Master unit for connection to an optional paging transmitter which sends alarm and fault messages to pocket pagers.Key FeaturesMesh network signalling technologyUp to 16 F-Link units can be networkedFully supervised with high immunitySelf-healing for quick and easy unit replacementInformative LCD text displayDIP switch configuration no bespoke factory programming necessaryLink monitoring in accordance with the relevant sections of BS5839-12017 24.2b and BSEN54-252008 4.2.6Comes with 14SMA quarter wave aerial - alternative aerials can be bought separatelyAdditional FeaturesThe front panel display indicates active zones unit status networkradio status and the received signal strength of incoming transmissions. A button is provided to mute the internal fault sounder and a key switch allows the unit to be reset or placed into test mode. The Identity and radio operating frequency of each unit is set using dip switches allowing for rapid and fuss-free installation.Software-configurable options include text descriptors for each Node and each zone event zone input type and output relay operating mode. Programmed settings are wirelessly distributed by the Master unit to all installed Nodes. An optional F-Link paging transmitter can be added to the system to send alarm and fault event descriptions to portable radio pagers. An optional interface can also be specified to provide a serial data output for logging purposes. GBP 1638.00 1
Scope F-Link 1224v Additional Fully Monitored Telemetry Transceiver FLINK4 Scope F-Link 1224v Additional Fully Monitored Telemetry Transceiver FLINK4The original Scope F-Link system has become a popular and secure way of remotely alerting and monitoring fire or security panels. The latest version adds even greater performance and improved functionality. F-Link is now housed in a larger case with plenty of cable entry points and an informative text display which provides status information and gives details of alarm messages.A system consists of two or more F-Link units working together to form a mesh network with each unit operating as both a transmitter and receiver. The radio link between units is monitored for faults in accordance with the relevant sections of BS5839-12017 24.2b and BSEN54-252008 4.2.6. There is an additional output on the Master unit for connection to an optional paging transmitter which sends alarm and fault messages to pocket pagers.Key FeaturesMesh network signalling technologyUp to 16 F-Link units can be networkedFully supervised with high immunitySelf-healing for quick and easy unit replacementInformative LCD text displayDIP switch configuration no bespoke factory programming necessaryLink monitoring in accordance with the relevant sections of BS5839-12017 24.2b and BSEN54-252008 4.2.6Comes with 14SMA quarter wave aerial - alternative aerials can be bought separatelyAdditional FeaturesThe front panel display indicates active zones unit status networkradio status and the received signal strength of incoming transmissions. A button is provided to mute the internal fault sounder and a key switch allows the unit to be reset or placed into test mode. The Identity and radio operating frequency of each unit is set using dip switches allowing for rapid and fuss-free installation.Software-configurable options include text descriptors for each Node and each zone event zone input type and output relay operating mode. Programmed settings are wirelessly distributed by the Master unit to all installed Nodes. An optional F-Link paging transmitter can be added to the system to send alarm and fault event descriptions to portable radio pagers. An optional interface can also be specified to provide a serial data output for logging purposes. GBP 819.00 1
Scope CX6UDC 12VDC Powered Connexions Transmitter - Three Serial Inputs - USB 1.0W Output Scope CX6UDC 12VDC Powered Connexions Transmitter - Three Serial Inputs - USB 1.0W OutputThe CX6UDC is a 12VDC Powered Connexions Transmitter with three serial inputs.The Connexions System has always provided the latest in on-site paging technology at a realistic price its modular design concept allows you to buy the basic unit and to add to it as your companys needs change so the initial outlay is kept to a minimum.Flexibility has always been the key word with the Scope Connexions Systems with its modular high-performance interfaces enabling robust connectivity to many host devices. They include connection to internal telephone PC network RS232 RS485 USB dry-contacts and voltage triggers. There is also an internal protocol conversion option which enables the translation of incoming RS232 data from host hardware into paging data providing paging from various fire intruder nurse call building management systems etc.The basic unit has two RS232 ports and eight dry contact inputs which enables the system to be hard wired to anything from an alarm control panel to a front door bell to alert prescribed users in the event that required criteria occur. All Connexions systems are supplied configured with default settings and are able to support up to 4-digit pager numbers as standard 9999 so expansion is already built in.The transmitter is designed to work at UHF frequencies which give an incredibly high degree of reliability in terms of the signalling success within a commercial environment whilst using very small and unobtrusive aerials. It uses the same international standard digital signalling system POCSAG deployed by most wide area paging companies. This is accepted to be amongst the most sophisticated and reliable in the world.Key FeaturesUSB 1.0W outputComes with 14BNC quarter wave aerial - alternative aerials can be bought separately GBP 842.40 1
Scope CX6F4DC 1-Watt Output Connexions Paging Transmitter For F-Link System Scope CX6F4DC 1-Watt Output Connexions Paging Transmitter For F-Link SystemThe Connexions System has always provided the latest inon-site paging technology at a realistic price its modular design conceptallows you to buy the basic unit and to add to it as your companys needschange so the initial outlay is kept to a minimum.Flexibility has always been the key word with the ScopeConnexions Systems with its modular high-performance interfaces enablingrobust connectivity to many host devices. They include connection to internaltelephone PC network RS232 RS485 USB dry-contacts and voltage triggers.There is also an internal protocol conversion option which enables thetranslation of incoming RS232 data from host hardware into paging dataproviding paging from various fire intruder nurse call building managementsystems etc.The basic unit has two RS232 ports and eight dry contactinputs which enables the system to be hard wired to anything from an alarmcontrol panel to a front door bell to alert prescribed users in the event thatrequired criteria occur. All Connexions systems are supplied configured withdefault settings and are able to support up to 4-digit pager numbers asstandard 9999 so expansion is already built in.The transmitter is designed to work at UHF frequencies whichgive an incredibly high degree of reliability in terms of the signallingsuccess within a commercial environment whilst using very small andunobtrusive aerials. It uses the same international standard digital signallingsystem POCSAG deployed by most wide area paging companies. This is acceptedto be amongst the most sophisticated and reliable in the world.Key FeaturesBenchmark UHF radio paging systemAvailable with two or three serial portsEight on-board volt free trigger contactsOptional telephone interfaceOptional Ethernet cardCan be driven by a PC either standalone or via a networkOptional protocol conversion software allows connection toalmost any fire security or nursecall panelIncludes interface leadRequires a 12VDC 1A PSUComes with14BNC quarter wave aerial -alternative aerials can be bought separately GBP 702.00 1
Scope CX6UMDC 12VDC Powered Connexions Transmitter - Three Serial amp USB Port with Third Party Panel Protocol. 1.0W Output Scope CX6UMDC 12VDC Powered Connexions Transmitter - Three Serial USB Port with Third Party Panel Protocol. 1.0W OutputThe CX6UMDC is a 12VDC Powered Connexions Transmitter - Three Serial USB Port with Third Party Panel Protocol.The Connexions System has always provided the latest in on-site paging technology at a realistic price its modular design concept allows you to buy the basic unit and to add to it as your companys needs change so the initial outlay is kept to a minimum.Flexibility has always been the key word with the Scope Connexions Systems with its modular high-performance interfaces enabling robust connectivity to many host devices. They include connection to internal telephone PC network RS232 RS485 USB dry-contacts and voltage triggers. There is also an internal protocol conversion option which enables the translation of incoming RS232 data from host hardware into paging data providing paging from various fire intruder nurse call building management systems etc.The basic unit has two RS232 ports and eight dry contact inputs which enables the system to be hard wired to anything from an alarm control panel to a front door bell to alert prescribed users in the event that required criteria occur. All Connexions systems are supplied configured with default settings and are able to support up to 4-digit pager numbers as standard 9999 so expansion is already built in.The transmitter is designed to work at UHF frequencies which give an incredibly high degree of reliability in terms of the signalling success within a commercial environment whilst using very small and unobtrusive aerials. It uses the same international standard digital signalling system POCSAG deployed by most wide area paging companies. This is accepted to be amongst the most sophisticated and reliable in the world.Key Features1.0W OutputComes with 14BNC quarter wave aerial - alternative aerials can be bought separately GBP 1263.60 1
Scope CX6U Mains Powered Connexions Transmitter - Three Serial Inputs - USB 1.0W Output Scope CX6U Mains Powered Connexions Transmitter - Three Serial Inputs - USB 1.0W OutputThe Connexions System has always provided the latest in on-site paging technology at a realistic price its modular design concept allows you to buy the basic unit and to add to it as your companys needs change so the initial outlay is kept to a minimum.Flexibility has always been the key word with the Scope Connexions Systems with its modular high-performance interfaces enabling robust connectivity to many host devices. They include connection to internal telephone PC network RS232 RS485 USB dry-contacts and voltage triggers. There is also an internal protocol conversion option which enables the translation of incoming RS232 data from host hardware into paging data providing paging from various fire intruder nurse call building management systems etc.The basic unit has two RS232 ports and eight dry contact inputs which enables the system to be hard wired to anything from an alarm control panel to a front door bell to alert prescribed users in the event that required criteria occur. All Connexions systems are supplied configured with default settings and are able to support up to 4-digit pager numbers as standard 9999 so expansion is already built in.The transmitter is designed to work at UHF frequencies which give an incredibly high degree of reliability in terms of the signalling success within a commercial environment whilst using very small and unobtrusive aerials. It uses the same international standard digital signalling system POCSAG deployed by most wide area paging companies. This is accepted to be amongst the most sophisticated and reliable in the world.Key FeaturesUSB 1.0W OutputComes with14BNC quarter wave aerial - alternative aerials can be bought separatelyBenchmark UHF radio paging systemAvailable with two or three serial port GBP 906.05 1
Scope CX6F4AC 1-Watt Output Connexions Paging Transmitter For F-Link System Scope CX6F4AC 1-Watt Output Connexions Paging Transmitter ForF-Link SystemThe Connexions System has always provided the latest inon-site paging technology at a realistic price its modular design conceptallows you to buy the basic unit and to add to it as your companys needschange so the initial outlay is kept to a minimum.Flexibility has always been the key word with the ScopeConnexions Systems with its modular high-performance interfaces enablingrobust connectivity to many host devices. They include connection to internaltelephone PC network RS232 RS485 USB dry-contacts and voltage triggers.There is also an internal protocol conversion option which enables thetranslation of incoming RS232 data from host hardware into paging dataproviding paging from various fire intruder nurse call building managementsystems etc.The basic unit has two RS232 ports and eight dry contactinputs which enables the system to be hard wired to anything from an alarmcontrol panel to a front door bell to alert prescribed users in the event thatrequired criteria occur. All Connexions systems are supplied configured withdefault settings and are able to support up to 4-digit pager numbers asstandard 9999 so expansion is already built in.The transmitter is designed to work at UHF frequencies whichgive an incredibly high degree of reliability in terms of the signallingsuccess within a commercial environment whilst using very small andunobtrusive aerials. It uses the same international standard digital signallingsystem POCSAG deployed by most wide area paging companies. This is acceptedto be amongst the most sophisticated and reliable in the world.Key FeaturesBenchmark UHF radio paging systemAvailable with two or three serial portsEight on-board volt free trigger contactsOptional telephone interfaceOptional Ethernet cardCan be driven by a PC either standalone or via a networkOptional protocol conversion software allows connection toalmost any fire security or nursecall panelIncludes interface leadMains poweredComes with14BNC quarter wave aerial -alternative aerials can be bought separately GBP 753.48 1
Scope CX6UM Mains Powered Connexions Transmitter - Three Serial amp USB Port with Third Party Panel Protocol. 1.0W Output Scope CX6UM Mains Powered Connexions Transmitter - Three Serial USB Port with Third Party Panel Protocol. 1.0W OutputThe CX6UM is a Mains Powered Connexions Transmitter with Three Serial USB Port and Third Party Panel Protocol.The Connexions System has always provided the latest in on-site paging technology at a realistic price its modular design concept allows you to buy the basic unit and to add to it as your companys needs change so the initial outlay is kept to a minimum.Flexibility has always been the key word with the Scope Connexions Systems with its modular high-performance interfaces enabling robust connectivity to many host devices. They include connection to internal telephone PC network RS232 RS485 USB dry-contacts and voltage triggers. There is also an internal protocol conversion option which enables the translation of incoming RS232 data from host hardware into paging data providing paging from various fire intruder nurse call building management systems etc.The basic unit has two RS232 ports and eight dry contact inputs which enables the system to be hard wired to anything from an alarm control panel to a front door bell to alert prescribed users in the event that required criteria occur. All Connexions systems are supplied configured with default settings and are able to support up to 4-digit pager numbers as standard 9999 so expansion is already built in.The transmitter is designed to work at UHF frequencies which give an incredibly high degree of reliability in terms of the signalling success within a commercial environment whilst using very small and unobtrusive aerials. It uses the same international standard digital signalling system POCSAG deployed by most wide area paging companies. This is accepted to be amongst the most sophisticated and reliable in the world.Key Features1.0W OutputComes with 14BNC quarter wave aerial - alternative aerials can be bought separately GBP 1327.25 1
Scope RX2 Mk2 Two Channel POCSAG Receiver with Logging Facilities Scope RX2 Mk2 Two Channel POCSAG Receiver with Logging FacilitiesThe new RX2 Mk2 is a complete re-design of the original RX2OEM. It is now supplied cased and programmed ready to go though there is still an OEM uncased version available. It has two zones with relay outputs a RS232 output and a USB port for programming. There is also a microSD slot with 8Gb card for recording event log data.The card also contains the programming software enabling complete control of the configuration of the unit from a PC and for downloading and analysing the data contained in the log. It is also possible to monitor live incoming data in text and graphical format.Key FeaturesReceives monitors and logs POCSAG dataTwo zone relay outputs RS232 output USB programming portMicroSD slot for event loggingPC software suppliedHigh quality category 1.5 receiver module EN 300 220-1 v3.1Frequency range of 430MHz to 470 MHzPower requirement is 12v - 13.8v DC maximum current draw is 126mA GBP 379.08 1
Scope Connexions CX6DC 12v Transmitter Scope Connexions CX6DC 12v TransmitterThe Connexions System has always provided the latest in on-site paging technology at a realistic price its modular design concept allows you to buy the basic unit and to add to it as your companys needs change so the initial outlay is kept to a minimum.Flexibility has always been the key word with the Scope Connexions Systems with its modular high-performance interfaces enabling robust connectivity to many host devices. They include connection to internal telephone PC network RS232 RS485 USB dry-contacts and voltage triggers. There is also an internal protocol conversion option which enables the translation of incoming RS232 data from host hardware into paging data providing paging from various fire intruder nurse call building management systems etc.The basic unit has two RS232 ports and eight dry contact inputs which enables the system to be hard wired to anything from an alarm control panel to a front door bell to alert prescribed users in the event that required criteria occur. All Connexions systems are supplied configured with default settings and are able to support up to 4-digit pager numbers as standard 9999 so expansion is already built in.The transmitter is designed to work at UHF frequencies which give an incredibly high degree of reliability in terms of the signalling success within a commercial environment whilst using very small and unobtrusive aerials. It uses the same international standard digital signalling system POCSAG deployed by most wide area paging companies. This is accepted to be amongst the most sophisticated and reliable in the world.Key FeaturesBenchmark UHF radio paging systemAvailable with two or three serial portsEight on-board volt free trigger contactsOptional telephone interfaceOptional Ethernet cardCan be driven by a PC either standalone or via a networkOptional protocol conversion software allows connection to almost any fire security or nursecall panelMains powered and DC models are availableModels with 1 watt or 5 watt RF outputRanges of up to 2 kilometres from 1 watt transmitter with wave aerialUnits with internal PSU CX6 90-240V AC 0.5A 5060Hz Mains CX5 90-240V AC 0.8A 5060Hz MainsUnits without PSU CX6DC 12-14V DC 1.5A minimum CX5DC 12-14V DC 3.0A minimumRF Output Power CX6 Up to 1 watt max CX5 Up to 5 watts max 2W max ERP using 459MHz paging band in the UKFrequency Range CX6 446.000MHz - 469.700MHz CX5 446.000MHz - 464.000MHzComes with14BNC quarter wave aerial -alternative aerials can be bought separately GBP 683.28 1
Scope Connexions CX6M Mains Powered Transmitter with Protocol Module Scope Connexions CX6M Mains Powered Transmitter with Protocol ModuleThe Connexions System has always provided the latest in on-site paging technology at a realistic price its modular design concept allows you to buy the basic unit and to add to it as your companys needs change so the initial outlay is kept to a minimum.Flexibility has always been the key word with the Scope Connexions Systems with its modular high-performance interfaces enabling robust connectivity to many host devices. They include connection to internal telephone PC network RS232 RS485 USB dry-contacts and voltage triggers. There is also an internal protocol conversion option which enables the translation of incoming RS232 data from host hardware into paging data providing paging from various fire intruder nurse call building management systems etc.The basic unit has two RS232 ports and eight dry contact inputs which enables the system to be hard wired to anything from an alarm control panel to a front door bell to alert prescribed users in the event that required criteria occur. All Connexions systems are supplied configured with default settings and are able to support up to 4-digit pager numbers as standard 9999 so expansion is already built in.The transmitter is designed to work at UHF frequencies which give an incredibly high degree of reliability in terms of the signalling success within a commercial environment whilst using very small and unobtrusive aerials. It uses the same international standard digital signalling system POCSAG deployed by most wide area paging companies. This is accepted to be amongst the most sophisticated and reliable in the world.Key FeaturesBenchmark UHF radio paging systemAvailable with two or three serial portsEight on-board volt free trigger contactsOptional telephone interfaceOptional Ethernet cardCan be driven by a PC either standalone or via a networkOptional protocol conversion software allows connection to almost any fire security or nursecall panelMains powered and DC models are availableModels with 1 watt or 5 watt RF outputRanges of up to 2 kilometres from 1 watt transmitter with wave aerialUnits with internal PSU CX6 90-240V AC 0.5A 5060Hz Mains CX5 90-240V AC 0.8A 5060Hz MainsUnits without PSU CX6DC 12-14V DC 1.5A minimum CX5DC 12-14V DC 3.0A minimumRF Output Power CX6 Up to 1 watt max CX5 Up to 5 watts max 2W max ERP using 459MHz paging band in the UKFrequency Range CX6 446.000MHz - 469.700MHz CX5 446.000MHz - 464.000MHzComes with14BNC quarter wave aerial -alternative aerials can be bought separately GBP 1168.13 1
Scope Connexions CX6 Mains Powered Transmitter Scope Connexions CX6 Mains Powered TransmitterThe Connexions System has always provided the latest in on-site paging technology at a realistic price its modular design concept allows you to buy the basic unit and to add to it as your companys needs change so the initial outlay is kept to a minimum.Flexibility has always been the key word with the Scope Connexions Systems with its modular high-performance interfaces enabling robust connectivity to many host devices. They include connection to internal telephone PC network RS232 RS485 USB dry-contacts and voltage triggers. There is also an internal protocol conversion option which enables the translation of incoming RS232 data from host hardware into paging data providing paging from various fire intruder nurse call building management systems etc.The basic unit has two RS232 ports and eight dry contact inputs which enables the system to be hard wired to anything from an alarm control panel to a front door bell to alert prescribed users in the event that required criteria occur. All Connexions systems are supplied configured with default settings and are able to support up to 4-digit pager numbers as standard 9999 so expansion is already built in.The transmitter is designed to work at UHF frequencies which give an incredibly high degree of reliability in terms of the signalling success within a commercial environment whilst using very small and unobtrusive aerials. It uses the same international standard digital signalling system POCSAG deployed by most wide area paging companies. This is accepted to be amongst the most sophisticated and reliable in the world.Key FeaturesBenchmark UHF radio paging systemAvailable with two or three serial portsEight on-board volt free trigger contactsOptional telephone interfaceOptional Ethernet cardCan be driven by a PC either standalone or via a networkOptional protocol conversion software allows connection to almost any fire security or nursecall panelMains powered and DC models are availableModels with 1 watt or 5 watt RF outputRanges of up to 2 kilometres from 1 watt transmitter with wave aerialUnits with internal PSU CX6 90-240V AC 0.5A 5060Hz Mains CX5 90-240V AC 0.8A 5060Hz MainsUnits without PSU CX6DC 12-14V DC 1.5A minimum CX5DC 12-14V DC 3.0A minimumRF Output Power CX6 Up to 1 watt max CX5 Up to 5 watts max 2W max ERP using 459MHz paging band in the UKFrequency Range CX6 446.000MHz - 469.700MHz CX5 446.000MHz - 464.000MHzComes with14BNC quarter wave aerial -alternative aerials can be bought separately GBP 746.93 1
Scope Connexions CX6MDC 12v Transmitter with Protocol Module Scope Connexions CX6MDC 12v Transmitter with Protocol ModuleThe Connexions System has always provided the latest in on-site paging technology at a realistic price its modular design concept allows you to buy the basic unit and to add to it as your companys needs change so the initial outlay is kept to a minimum.Flexibility has always been the key word with the Scope Connexions Systems with its modular high-performance interfaces enabling robust connectivity to many host devices. They include connection to internal telephone PC network RS232 RS485 USB dry-contacts and voltage triggers. There is also an internal protocol conversion option which enables the translation of incoming RS232 data from host hardware into paging data providing paging from various fire intruder nurse call building management systems etc.The basic unit has two RS232 ports and eight dry contact inputs which enables the system to be hard wired to anything from an alarm control panel to a front door bell to alert prescribed users in the event that required criteria occur. All Connexions systems are supplied configured with default settings and are able to support up to 4-digit pager numbers as standard 9999 so expansion is already built in.The transmitter is designed to work at UHF frequencies which give an incredibly high degree of reliability in terms of the signalling success within a commercial environment whilst using very small and unobtrusive aerials. It uses the same international standard digital signalling system POCSAG deployed by most wide area paging companies. This is accepted to be amongst the most sophisticated and reliable in the world.Key FeaturesBenchmark UHF radio paging systemAvailable with two or three serial portsEight on-board volt free trigger contactsOptional telephone interfaceOptional Ethernet cardCan be driven by a PC either standalone or via a networkOptional protocol conversion software allows connection to almost any fire security or nursecall panelMains powered and DC models are availableModels with 1 watt or 5 watt RF outputRanges of up to 2 kilometres from 1 watt transmitter with wave aerialUnits with internal PSU CX6 90-240V AC 0.5A 5060Hz Mains CX5 90-240V AC 0.8A 5060Hz MainsUnits without PSU CX6DC 12-14V DC 1.5A minimum CX5DC 12-14V DC 3.0A minimumRF Output Power CX6 Up to 1 watt max CX5 Up to 5 watts max 2W max ERP using 459MHz paging band in the UKFrequency Range CX6 446.000MHz - 469.700MHz CX5 446.000MHz - 464.000MHzComes with14BNC quarter wave aerial -alternative aerials can be bought separately GBP 1104.48 1
Scope CX5RUM Mains Powered Connexions Transmitter Three Serial USB Port With Third Party Panel Protocol 2.0w Output Scope CX5RUM Mains Powered Connexions Transmitter Three Serial USB Port With Third Party Panel Protocol 2.0w OutputThe Scope Connexions System provides the latest in on-sitepaging technology at a realistic price. Its modular design concept allowsexpansion as needs change keeping the initial outlay to a minimum.The basic Scope Connexions CX5 AC unit has two RS232 portsand eight dry contact inputs which enables the system to be hard wired toanything from an alarm control panel to a front door bell to alert prescribedusers in the event that required criteria occur. All Connexions systems aresupplied configured with default settings and are able to support up to 4 digitpager numbers as standard 9999 so expansion is already built in.The transmitter is designed to work at UHF frequencies whichgive an incredibly high degree of reliability in terms of the signallingsuccess within a commercial environment whilst using very small andunobtrusive aerials. It uses the same international standard digital signallingsystem POCSAG deployed by most wide area paging companies. This is acceptedto be amongst the most sophisticated and reliable in the world.Key FeaturesThree serial inputsUSB portMains poweredThird party panel protocl2.0w outputComes with 14BNC quarter wave aerial - alternative aerials can be bought separately GBP 1566.86 1
Scope CX5RUDC 12VDC Powered Connexions Transmitter - Three Serial Inputs - USB 2.0w Output Scope CX5RUDC 12VDC Powered Connexions Transmitter - Three Serial Inputs - USB 2.0w OutputThe Scope Connexions System provides the latest in on-sitepaging technology at a realistic price. Its modular design concept allowsexpansion as needs change keeping the initial outlay to a minimum.The basic Scope Connexions CX5 AC unit has two RS232 portsand eight dry contact inputs which enables the system to be hard wired toanything from an alarm control panel to a front door bell to alert prescribedusers in the event that required criteria occur. All Connexions systems aresupplied configured with default settings and are able to support up to 4 digitpager numbers as standard 9999 so expansion is already built in.The transmitter is designed to work at UHF frequencies whichgive an incredibly high degree of reliability in terms of the signallingsuccess within a commercial environment whilst using very small andunobtrusive aerials. It uses the same international standard digital signallingsystem POCSAG deployed by most wide area paging companies. This is acceptedto be amongst the most sophisticated and reliable in the world.Key FeaturesThree serial inputsUSB 2.0w output12VDC poweredComes with 14BNC quarter wave aerial - alternative aerials can be bought separately GBP 1108.22 1
Scope CX5RM Mains Powered Connexions Transmitter With Third Party Panel Protocol - 2.0W Output Scope CX5RM Mains Powered Connexions Transmitter With Third Party Panel Protocol - 2.0W OutputThe Scope Connexions System provides the latest in on-sitepaging technology at a realistic price. Its modular design concept allowsexpansion as needs change keeping the initial outlay to a minimum.The basic Scope Connexions CX5 AC unit has two RS232 portsand eight dry contact inputs which enables the system to be hard wired toanything from an alarm control panel to a front door bell to alert prescribedusers in the event that required criteria occur. All Connexions systems aresupplied configured with default settings and are able to support up to 4 digitpager numbers as standard 9999 so expansion is already built in.The transmitter is designed to work at UHF frequencies whichgive an incredibly high degree of reliability in terms of the signallingsuccess within a commercial environment whilst using very small andunobtrusive aerials. It uses the same international standard digital signallingsystem POCSAG deployed by most wide area paging companies. This is acceptedto be amongst the most sophisticated and reliable in the world.Key Features2.0w outputMains poweredThird party panel protocolComes with 14BNC quarter wave aerial - alternative aerials can be bought separately GBP 1405.87 1
Scope CX5RU Mains Powered Connexions Transmitter - Three Serial Inputs - USB 2.0w Output Scope CX5RU Mains Powered Connexions Transmitter - Three Serial Inputs - USB 2.0w OutputThe Scope Connexions System provides the latest in on-sitepaging technology at a realistic price. Its modular design concept allowsexpansion as needs change keeping the initial outlay to a minimum.The basic Scope Connexions CX5 AC unit has two RS232 portsand eight dry contact inputs which enables the system to be hard wired toanything from an alarm control panel to a front door bell to alert prescribedusers in the event that required criteria occur. All Connexions systems aresupplied configured with default settings and are able to support up to 4 digitpager numbers as standard 9999 so expansion is already built in.The transmitter is designed to work at UHF frequencies whichgive an incredibly high degree of reliability in terms of the signallingsuccess within a commercial environment whilst using very small andunobtrusive aerials. It uses the same international standard digital signallingsystem POCSAG deployed by most wide area paging companies. This is acceptedto be amongst the most sophisticated and reliable in the world.Key FeaturesThree serial inputsUSB 2.0w outputMains poweredComes with 14BNC quarter wave aerial - alternative aerials can be bought separately GBP 1138.18 1
Scope CX5RDC 12VDC Powered Connexions Transmitter - Two Serial Inputs - 2.0w Output Scope CX5RDC 12VDC Powered Connexions Transmitter - Two Serial Inputs - 2.0w OutputThe Scope Connexions System provides the latest in on-sitepaging technology at a realistic price. Its modular design concept allowsexpansion as needs change keeping the initial outlay to a minimum.The basic Scope Connexions CX5 AC unit has two RS232 portsand eight dry contact inputs which enables the system to be hard wired toanything from an alarm control panel to a front door bell to alert prescribedusers in the event that required criteria occur. All Connexions systems aresupplied configured with default settings and are able to support up to 4 digitpager numbers as standard 9999 so expansion is already built in.The transmitter is designed to work at UHF frequencies whichgive an incredibly high degree of reliability in terms of the signallingsuccess within a commercial environment whilst using very small andunobtrusive aerials. It uses the same international standard digital signallingsystem POCSAG deployed by most wide area paging companies. This is acceptedto be amongst the most sophisticated and reliable in the world.Key FeaturesTwo serial inputs2.0w output12DVC poweredComes with 14BNC quarter wave aerial - alternative aerials can be bought separately GBP 947.23 1
Scope CX5RUMDC 12VDC Powered Connexions Transmitter Three Serial USB Port With Third Party Panel Protocol 2.0w Output Scope CX5RUMDC 12VDC Powered Connexions Transmitter Three Serial USB Port With Third Party Panel Protocol 2.0w OutputThe Scope Connexions System provides the latest in on-sitepaging technology at a realistic price. Its modular design concept allowsexpansion as needs change keeping the initial outlay to a minimum.The basic Scope Connexions CX5 AC unit has two RS232 portsand eight dry contact inputs which enables the system to be hard wired toanything from an alarm control panel to a front door bell to alert prescribedusers in the event that required criteria occur. All Connexions systems aresupplied configured with default settings and are able to support up to 4 digitpager numbers as standard 9999 so expansion is already built in.The transmitter is designed to work at UHF frequencies whichgive an incredibly high degree of reliability in terms of the signallingsuccess within a commercial environment whilst using very small andunobtrusive aerials. It uses the same international standard digital signallingsystem POCSAG deployed by most wide area paging companies. This is acceptedto be amongst the most sophisticated and reliable in the world.Key FeaturesThree serial inputsUSB port12VDC poweredThird party panel protocol2.0w output GBP 1537.85 1
Scope CX5R Mains Powered Connexions Transmitter - Two Serial Inputs - 2.0w Output Scope CX5R Mains Powered Connexions Transmitter - Two SerialInputs - 2.0w OutputThe Scope Connexions System provides the latest in on-sitepaging technology at a realistic price. Its modular design concept allowsexpansion as needs change keeping the initial outlay to a minimum.The basic Scope Connexions CX5 AC unit has two RS232 portsand eight dry contact inputs which enables the system to be hard wired toanything from an alarm control panel to a front door bell to alert prescribedusers in the event that required criteria occur. All Connexions systems aresupplied configured with default settings and are able to support up to 4 digitpager numbers as standard 9999 so expansion is already built in.The transmitter is designed to work at UHF frequencies whichgive an incredibly high degree of reliability in terms of the signallingsuccess within a commercial environment whilst using very small andunobtrusive aerials. It uses the same international standard digital signallingsystem POCSAG deployed by most wide area paging companies. This is acceptedto be amongst the most sophisticated and reliable in the world.Key FeaturesTwo serial inputs2.0w outputMains poweredComes with 14BNC quarter wave aerial - alternative aerials can be bought separately GBP 978.12 1
Scope CX5RMDC 12VDC Powered Connexions Transmitter With Third Party Panel Protocol - 2.0W Output Scope CX5RMDC 12VDC Powered Connexions Transmitter With Third Party Panel Protocol - 2.0W OutputThe Scope Connexions System provides the latest in on-sitepaging technology at a realistic price. Its modular design concept allowsexpansion as needs change keeping the initial outlay to a minimum.The basic Scope Connexions CX5 AC unit has two RS232 portsand eight dry contact inputs which enables the system to be hard wired toanything from an alarm control panel to a front door bell to alert prescribedusers in the event that required criteria occur. All Connexions systems aresupplied configured with default settings and are able to support up to 4 digitpager numbers as standard 9999 so expansion is already built in.The transmitter is designed to work at UHF frequencies whichgive an incredibly high degree of reliability in terms of the signallingsuccess within a commercial environment whilst using very small andunobtrusive aerials. It uses the same international standard digital signallingsystem POCSAG deployed by most wide area paging companies. This is acceptedto be amongst the most sophisticated and reliable in the world.Key Features2.0w output12vdc poweredThird party panel protocolComes with14BNC quarter wave aerial -alternative aerials can be bought separately GBP 1374.98 1