Scope MPA PEN4 Personal Radio Alarm Transmitter with Neck Cord Scope MPA PEN4 Personal Radio Alarm Transmitter with Neck CordThe Scope MPA personal pendant is just as suitable for Healthcare Workers as it is for elderly and vulnerable patients. It can form part of a sophisticated integrated system by transmitting to our fixed multi-zone receiver. This can then be integrated with OEM equipment or used in conjunction with our Connexions range of products.For simple plug-and-play applications just signal directly to any of our portable or wall-mounted range of pagers.The ergonomic design of the case makes it extremely easy to use even by people with arthritic hands and other disabilities.As well as by the push button an emergency alarm can also be raised by disconnecting the neck cord. The MPA has been designed to Scopes usual high standard and is rugged enough to cope with most environments.Key FeaturesRugged ergonomically designed casing IP64 rated2 trigger zones fall alarmNon-contact cancelinhibit functionFrequency Programmable 430MHz - 470MHz1Test call functionLow power sleep mode10mW maximum output powerIdeal ForElderly or disabled people as a distress alarmHealth care Workers as a panic or assistance alarmSwimming pool Attendants as an emergency alarm GBP 145.08 1
Scope PageTek 4 Mains Powered 5 Zone Paging Transmitter with Aerial Scope PageTek 4 Mains Powered 5 Zone Paging Transmitter with AerialScope PageTek 4 paging transmitters are available with either 5 or 10 programmable zone inputs which when triggered will automatically send the active zone message to portable or fixed pagers. This message can be repeated at predetermined intervals and a secondary message can be sent when the zone returns to its inactive state if required.Multiple transmitters can be deployed at various locations all signalling to the same pagerpager groups. Regular In Service calls can be automatically sent to the receiving devices which can indicate No Service on the pagers or trigger a fault zone on fixed receivers if the calls are not received. This gives the end-user confidence that the system is operating properly. The 10 zone version also has a special Burglar Alarm mode with configurable entryexit delay transit zones and entry zone.For advanced users who wish to program the unit themselves a Programming Kit can be purchased. This consists of Windows based application software and a USB cable for PC. This allows all functions to be programmed and stored in the system n secure non-volatile memory. 12VDC 24VDC and mains powered versions are available with an optional battery back-up facility for the mains version.Key Features5 and 10 zone input versionsMains powered 24V and 12V DC modelsAutomated In Service calls can be configured to alert pagers to the loss of radio signalFully programmable via USB with optional PC softwareProgrammable individual pager text messages for each zone and each zone stateAdjustable trigger times delays alarm repeats are all programmable options. In addition the 10 inputversion has a dedicated burglar alarm modeHigh quality high power 1w erp transmitter modules provide rock-solid RF performance.UHF POCSAG signalling format ensures excellent propagation even in difficult environmentsComes with14BNC quarter wave aerial -alternative aerials can be bought separately GBP 347.26 1
Scope PageTek 4 24v 10 Zone Paging Transmitter with Aerial Scope PageTek 4 24v 10 Zone Paging Transmitter with AerialScope PageTek 4 paging transmitters are available with either 5 or 10 programmable zone inputs which when triggered will automatically send the active zone message to portable or fixed pagers. This message can be repeated at predetermined intervals and a secondary message can be sent when the zone returns to its inactive state if required.Multiple transmitters can be deployed at various locations all signalling to the same pagerpager groups. Regular In Service calls can be automatically sent to the receiving devices which can indicate No Service on the pagers or trigger a fault zone on fixed receivers if the calls are not received. This gives the end-user confidence that the system is operating properly. The 10 zone version also has a special Burglar Alarm mode with configurable entryexit delay transit zones and entry zone.For advanced users who wish to program the unit themselves a Programming Kit can be purchased. This consists of Windows based application software and a USB cable for PC. This allows all functions to be programmed and stored in the system n secure non-volatile memory. 12VDC 24VDC and mains powered versions are available with an optional battery back-up facility for the mains version.Key Features5 and 10 zone input versionsMains powered 24V and 12V DC modelsAutomated In Service calls can be configured to alert pagers to the loss of radio signalFully programmable via USB with optional PC softwareProgrammable individual pager text messages for each zone and each zone stateAdjustable trigger times delays alarm repeats are all programmable options. In addition the 10 input version has a dedicated burglar alarm modeHigh quality high power 1w erp transmitter modules provide rock-solid RF performanceUHF POCSAG signalling format ensures excellent propagation even in difficult environmentsComes with14BNC quarter wave aerial -alternative aerials can be bought separately GBP 357.55 1
Scope PageTek 4 24v 5 Zone Paging Transmitter with Aerial Scope PageTek 4 24v 5 Zone Paging Transmitter with AerialScope PageTek 4 paging transmitters are available with either 5 or 10 programmable zone inputs which when triggered will automatically send the active zone message to portable or fixed pagers. This message can be repeated at predetermined intervals and a secondary message can be sent when the zone returns to its inactive state if required.Multiple transmitters can be deployed at various locations all signalling to the same pagerpager groups. Regular In Service calls can be automatically sent to the receiving devices which can indicate No Service on the pagers or trigger a fault zone on fixed receivers if the calls are not received. This gives the end-user confidence that the system is operating properly. The 10 zone version also has a special Burglar Alarm mode with configurable entryexit delay transit zones and entry zone.For advanced users who wish to program the unit themselves a Programming Kit can be purchased. This consists of Windows based application software and a USB cable for PC. This allows all functions to be programmed and stored in the system n secure non-volatile memory. 12VDC 24VDC and mains powered versions are available with an optional battery back-up facility for the mains version.Key Features5 and 10 zone input versionsMains powered 24V and 12V DC modelsAutomated In Service calls can be configured to alert pagers to the loss of radio signalFully programmable via USB with optional PC softwareProgrammable individual pager text messages for each zone and each zone stateAdjustable trigger times delays alarm repeats are all programmable options. In addition the 10 inputversion has a dedicated burglar alarm modeHigh quality high power 1w erp transmitter modules provide rock-solid RF performance.UHF POCSAG signalling format ensures excellent propagation even in difficult environmentsComes with14BNC quarter wave aerial -alternative aerials can be bought separately GBP 305.14 1
Scope PageTek 4 12v 10 Zone Paging Transmitter with Aerial Scope PageTek 4 12v 10 Zone Paging Transmitter with AerialScope PageTek 4 paging transmitters are available with either 5 or 10 programmable zone inputs which when triggered will automatically send the active zone message to portable or fixed pagers. This message can be repeated at predetermined intervals and a secondary message can be sent when the zone returns to its inactive state if required.Multiple transmitters can be deployed at various locations all signalling to the same pagerpager groups. Regular In Service calls can be automatically sent to the receiving devices which can indicate No Service on the pagers or trigger a fault zone on fixed receivers if the calls are not received. This gives the end-user confidence that the system is operating properly. The 10 zone version also has a special Burglar Alarm mode with configurable entryexit delay transit zones and entry zone.For advanced users who wish to program the unit themselves a Programming Kit can be purchased. This consists of Windows based application software and a USB cable for PC. This allows all functions to be programmed and stored in the system n secure non-volatile memory. 12VDC 24VDC and mains powered versions are available with an optional battery back-up facility for the mains version.Key Features5 and 10 zone input versionsMains powered 24V and 12V DC modelsAutomated In Service calls can be configured to alert pagers to the loss of radio signalFully programmable via USB with optional PC softwareProgrammable individual pager text messages for each zone and each zone stateAdjustable trigger times delays alarm repeats are all programmable options. In addition the 10 inputversion has a dedicated burglar alarm modeHigh quality high power 1w erp transmitter modules provide rock-solid RF performance.UHF POCSAG signalling format ensures excellent propagation even in difficult environmentsComes with14BNC quarter wave aerial -alternative aerials can be bought separately GBP 328.54 1
Scope PageTek 4 12v 5 Zone Paging Transmitter with Aerial Scope PageTek 4 12v 5 Zone Paging Transmitter with AerialScope PageTek 4 paging transmitters are available with either 5 or 10 programmable zone inputs which when triggered will automatically send the active zone message to portable or fixed pagers. This message can be repeated at predetermined intervals and a secondary message can be sent when the zone returns to its inactive state if required.Multiple transmitters can be deployed at various locations all signalling to the same pagerpager groups. Regular In Service calls can be automatically sent to the receiving devices which can indicate No Service on the pagers or trigger a fault zone on fixed receivers if the calls are not received. This gives the end-user confidence that the system is operating properly. The 10 zone version also has a special Burglar Alarm mode with configurable entryexit delay transit zones and entry zone.For advanced users who wish to program the unit themselves a Programming Kit can be purchased. This consists of Windows based application software and a USB cable for PC. This allows all functions to be programmed and stored in the system n secure non-volatile memory. 12VDC 24VDC and mains powered versions are available with an optional battery back-up facility for the mains version.Key Features5 and 10 zone input versionsMains powered 24V and 12V DC modelsAutomated In Service calls can be configured to alert pagers to the loss of radio signalFully programmable via USB with optional PC softwareProgrammable individual pager text messages for each zone and each zone stateAdjustable trigger times delays alarm repeats are all programmable options. In addition the 10 input version has a dedicated burglar alarm modeHigh quality high power 1w erp transmitter modules provide rock-solid RF performance.UHF POCSAG signalling format ensures excellent propagation even in difficult environmentsComes with14BNC quarter wave aerial - alternative aerials can be bought separately GBP 281.74 1
Scope PageTek 4 Mains Powered 10 Zone Paging Transmitter with Aerial Scope PageTek 4 Mains Powered 10 Zone Paging Transmitter with AerialScope PageTek 4 paging transmitters are available with either 5 or 10 programmable zone inputs which when triggered will automatically send the active zone message to portable or fixed pagers. This message can be repeated at predetermined intervals and a secondary message can be sent when the zone returns to its inactive state if required.Multiple transmitters can be deployed at various locations all signalling to the same pagerpager groups. Regular In Service calls can be automatically sent to the receiving devices which can indicate No Service on the pagers or trigger a fault zone on fixed receivers if the calls are not received. This gives the end-user confidence that the system is operating properly. The 10 zone version also has a special Burglar Alarm mode with configurable entryexit delay transit zones and entry zone.For advanced users who wish to program the unit themselves a Programming Kit can be purchased. This consists of Windows based application software and a USB cable for PC. This allows all functions to be programmed and stored in the system n secure non-volatile memory. 12VDC 24VDC and mains powered versions are available with an optional battery back-up facility for the mains version.Key Features5 and 10 zone input versionsMains powered 24V and 12V DC modelsAutomated In Service calls can be configured to alert pagers to the loss of radio signalFully programmable via USB with optional PC softwareProgrammable individual pager text messages for each zone and each zone stateAdjustable trigger times delays alarm repeats are all programmable options. In addition the 10 input version has a dedicated burglar alarm modeHigh quality high power 1w erp transmitter modules provide rock-solid RF performance.UHF POCSAG signalling format ensures excellent propagation even in difficult environmentsComes with14BNC quarter wave aerial -alternative aerials can be bought separately GBP 412.78 1
Scope F-Link 1224v Fully Monitored Telemetry Transceivers FLINK4KIT Scope F-Link FLINK4KIT 1224v Fully Monitored Telemetry TransceiversThe original Scope F-Link system has become a popular and secure way of remotely alerting and monitoring fire or security panels. The latest version adds even greater performance and improved functionality. F-Link is now housed in a larger case with plenty of cable entry points and an informative text display which provides status information and gives details of alarm messages.A system consists of two or more F-Link units working together to form a mesh network with each unit operating as both a transmitter and receiver. The radio link between units is monitored for faults in accordance with the relevant sections of BS5839-12017 24.2b and BSEN54-252008 4.2.6. There is an additional output on the Master unit for connection to an optional paging transmitter which sends alarm and fault messages to pocket pagers.Key FeaturesMesh network signalling technologyUp to 16 F-Link units can be networkedFully supervised with high immunitySelf-healing for quick and easy unit replacementInformative LCD text displayDIP switch configuration no bespoke factory programming necessaryLink monitoring in accordance with the relevant sections of BS5839-12017 24.2b and BSEN54-252008 4.2.6Comes with 14SMA quarter wave aerial - alternative aerials can be bought separatelyAdditional FeaturesThe front panel display indicates active zones unit status networkradio status and the received signal strength of incoming transmissions. A button is provided to mute the internal fault sounder and a key switch allows the unit to be reset or placed into test mode. The Identity and radio operating frequency of each unit is set using dip switches allowing for rapid and fuss-free installation.Software-configurable options include text descriptors for each Node and each zone event zone input type and output relay operating mode. Programmed settings are wirelessly distributed by the Master unit to all installed Nodes. An optional F-Link paging transmitter can be added to the system to send alarm and fault event descriptions to portable radio pagers. An optional interface can also be specified to provide a serial data output for logging purposes. GBP 1638.00 1
Scope F-Link 1224v Additional Fully Monitored Telemetry Transceiver FLINK4 Scope F-Link 1224v Additional Fully Monitored Telemetry Transceiver FLINK4The original Scope F-Link system has become a popular and secure way of remotely alerting and monitoring fire or security panels. The latest version adds even greater performance and improved functionality. F-Link is now housed in a larger case with plenty of cable entry points and an informative text display which provides status information and gives details of alarm messages.A system consists of two or more F-Link units working together to form a mesh network with each unit operating as both a transmitter and receiver. The radio link between units is monitored for faults in accordance with the relevant sections of BS5839-12017 24.2b and BSEN54-252008 4.2.6. There is an additional output on the Master unit for connection to an optional paging transmitter which sends alarm and fault messages to pocket pagers.Key FeaturesMesh network signalling technologyUp to 16 F-Link units can be networkedFully supervised with high immunitySelf-healing for quick and easy unit replacementInformative LCD text displayDIP switch configuration no bespoke factory programming necessaryLink monitoring in accordance with the relevant sections of BS5839-12017 24.2b and BSEN54-252008 4.2.6Comes with 14SMA quarter wave aerial - alternative aerials can be bought separatelyAdditional FeaturesThe front panel display indicates active zones unit status networkradio status and the received signal strength of incoming transmissions. A button is provided to mute the internal fault sounder and a key switch allows the unit to be reset or placed into test mode. The Identity and radio operating frequency of each unit is set using dip switches allowing for rapid and fuss-free installation.Software-configurable options include text descriptors for each Node and each zone event zone input type and output relay operating mode. Programmed settings are wirelessly distributed by the Master unit to all installed Nodes. An optional F-Link paging transmitter can be added to the system to send alarm and fault event descriptions to portable radio pagers. An optional interface can also be specified to provide a serial data output for logging purposes. GBP 819.00 1