SAS NET204M Remote Input Call Point Alarm Call Facility Push Button Reset SAS NET204M Remote Input Call Point Alarm Call Facility Push Button ResetA device designed to receive an input from an external alarm source for example a door bell push button or a lift alarm call point. Once activated it is reset by pressing the blue button. A red staff-to-staff alarm button is also provided and the same visit and presence facilities are included.The Nursecall System helps patients and staff to relax in the knowledge that should help be required either by the patient or by a member of staff assistance can be directed to the specific room at the touch of a button. GBP 115.84 1
SAS NET204 Remote Input Call Point Alarm Call Facility Magnetic Key Reset SAS NET204 Remote Input Call Point Alarm Call Facility Magnetic Key ResetThe NET204 shares the same features as the NET204M but uses a magnetic key for the reset and alarm functions.The Nursecall System helps patients and staff to relax in the knowledge that should help be required either by the patient or by a member of staff assistance can be directed to the specific room at the touch of a button. GBP 115.84 1
SAS RED245M Push Button Assistance Call Point with Push Button Reset SAS RED245M Push Button Assistance Call Point with Push Button ResetThis alarm call point is similar to the RED245 but is reset by the blue push button. A small red button is used to generate a higher priority attack call.The Red Alert system helps staff feel more secure knowing that in an emergency they can summon assistance at the touch of a button on their personal transmitter. GBP 115.84 1
SAS NET215 Slave Push Button Call Point SAS NET215 Slave Push Button Call PointThe NET215 are sometimes located in double bedrooms or en-suite bathrooms. This unit has a large orange call button and a socket for a push-to-call lead. As is does not have any reset or staff-to-staff alarm feature it is installed in conjunction with one of our nurse call units.The Nursecall System helps patients and staff to relax in the knowledge that should help be required either by the patient or by a member of staff assistance can be directed to the specific room at the touch of a button. GBP 73.72 1
SAS RED285M Battery Operated Call Point with Push Button Reset SAS RED285M Battery Operated Call Point with Push Button ResetThe RED285M is a battery operated call point which features a push button reset. GBP 114.75 1
SAS RED201 System Control amp Power Supply Unit PSU SAS RED201 System Control Power Supply Unit PSUThe HUB is the central control of the Red Alert system and has the ultimate capacity of 254 addressable call points and 26 LCD indicator panels. The cabinet has a lockable hinged door and houses the main control PCB HUB the power supply unit and has space for battery back-up if required.It should be installed centrally in the system layout normally in a secure location and requires a 240 mains supply from an un-switched fused spur. An input from a day night volume control switch is available to adjust the volume of the LCD indicator panels alternatively this can be set to automatically change at a certain time of day. A voltage free set of contacts is provided to trigger external devices in the event of a call an alarm call or an attack call. These contacts can be used to trigger tone pagers or additional voltage sounder or strobe lights etc.The Red Alert system helps staff feel more secure knowing that in an emergency they can summon assistance at the touch of a button on their personal transmitter. GBP 291.60 1
SAS NET201 System Control Hub and Power Supply Unit PSU SAS NET201 System Control Hub and Power Supply Unit PSUThe HUB is the central control of the Network II system and has the ultimate capacity of 254 addressable call points and 26 LCD indicator panels. The cabinet has a lockable hinged door and houses the main control PCB HUB the power supply unit and has space for battery back-up if required. It should be installed centrally in the system layout normally in a secure location and requires a 240 mains supply from an un-switched fused spur.An input from a day night volume control switch is available to adjust the volume of the LCD indicator panels alternatively this can be set to automatically change at a certain time of day. A voltage free set of contacts is provided to trigger external devices in the event of a call an alarm call or a crash call. These contacts can be used to trigger tone pagers or additional voltage sounder or strobe lights etc.The Nursecall System helps patients and staff to relax in the knowledge that should help be required either by the patient or by a member of staff assistance can be directed to the specific room at the touch of a button. GBP 486.00 1
SAS RED245 Push Button Assistance Call Point with Magnetic Reset SAS RED245 Push Button Assistance Call Point with Magnetic ResetA wall mounted call point with a large red actuator to activate an alarm call. These units are used in areas where staff or visitors may need to activate the alarm system but may not be carrying an infra-red transmitter. It is reset using a magnetic reset key RED216.The Red Alert system helps staff feel more secure knowing that in an emergency they can summon assistance at the touch of a button on their personal transmitter. GBP 115.84 1
SAS NET205M Patient Call Unit with Alarm amp Crash Call Facilities Push Button Reset SAS NET205M Patient Call Unit with Alarm Crash Call Facilities Push Button ResetUsually located at each bed-head they feature a large orange button which is used by patients when in need of assistance. Staff attending a call can raise a more urgent staff-to-staff call to summon help if necessary and a third call level crash call can be used for medical emergencies. They have a socket for a push-to-call extension lead NET206 that is monitored in case the lead is pulled out from its socket inadvertently.The staff operations are carried out using push buttons on this version. The blue reset button can also be used to log a visit to a room and also register the nurses presence within the room. A reassurance light is illuminated red to reassure a call has been made and green to inform the patient that staff are on their way.The Nursecall System helps patients and staff to relax in the knowledge that should help be required either by the patient or by a member of staff assistance can be directed to the specific room at the touch of a button. GBP 115.84 1
SAS NET205MNA Call Point with Push Button Reset - No Alarm Call Facility SAS NET205MNA Call Point with Push Button Reset - No Alarm Call FacilityThe NET205MNA is a Call Point with Push Button Reset.The Nursecall System helps patients and staff to relax in the knowledge that should help be required either by the patient or by a member of staff assistance can be directed to the specific room at the touch of a button.Key FeaturesNo Alarm Call Facility GBP 115.84 1
SAS NET207M Patient Call Unit with Alarm amp Infrared Sensor Push Button Reset SAS NET207M Patient Call Unit with Alarm Infrared Sensor Push Button ResetThis call point has the same features and functions as the NET205M with the addition of an infra-red sensor. This sensor can be activated using one of our transmitters. We have transmitters especially designed for a patient to use and also for staff to carry.This type of call point is often installed in lounge areas so particularly vulnerable patients can be given a transmitter enabling them to call for assistance from their chair. Staffs often carry a transmitter when they may be subject to an assault from visitors or patients in these circumstances this type of call point would be installed throughout the building.The Nursecall System helps patients and staff to relax in the knowledge that should help be required either by the patient or by a member of staff assistance can be directed to the specific room at the touch of a button. GBP 147.42 1
SAS NET208 Infrared Call Transmitter For Use With NET207 Range SAS NET208 Infrared Call Transmitter For Use With NET207 RangeA transmitter designed to be easy to operate. A large orange button activates an infra-red sensor with the lowest priority call level. It is ideal for use by residents or patients who are vulnerable and need the use of a call system. It can be supplied as a necklace pendant or as a hand held unit.The Nursecall System helps patients and staff to relax in the knowledge that should help be required either by the patient or by a member of staff assistance can be directed to the specific room at the touch of a button. GBP 97.20 1
SAS RED234 Datastore Software Package with RS232 Port with 3m Lead SAS RED234 Datastore Software Package with RS232 Port with 3m LeadThe software package enables all events on the Red Alert system to be logged on a PC. The date time location and type of alarm call will be recorded along with reset and fault reports. A dedicated PC and printer are not required and the programme can be minimised and run in the background.The Red Alert system helps staff feel more secure knowing that in an emergency they can summon assistance at the touch of a button on their personal transmitter.Key FeaturesIt is possible to print selected data using the PCs own printer.The information displayed can be filtered to only shown the data you are currently interested in i.e. all logged information for CONSULTING ROOM 2.An alert popup window or sound can be set to inform you of a new event.The colours of the text background and font can be altered to suit your requirements.Personal details can be entered for each identification in the log i.e. response procedures access requirements etc. GBP 567.00 1
SAS NET234 Data Store Software SAS NET234 Data Store SoftwareThe software package enables all events on the Network II system to be logged on a PC. The date time location and type of alarm call will be recorded along with reset and fault reports. A dedicated PC and printer are not required and the programme can be minimised and run in the background.Key FeaturesIt is possible to print selected data using the PCs own printer.The information displayed can be filtered to only shown the data you are currently interested in i.e. all logged information for 1st floor bedroom 6.An alert popup window or sound can be set to inform you of a new event.The colours of the text background and font can be altered to suit your requirements.Personal details can be entered for identification in the log i.e. family contact details or drugs information.The Nursecall System helps patients and staff to relax in the knowledge that should help be required either by the patient or by a member of staff assistance can be directed to the specific room at the touch of a button. GBP 729.00 1
SAS NET228 Pager Transmitter Alphanumeric Type SAS NET228 Pager Transmitter Alphanumeric TypeAlphanumeric paging transmitter used in conjunction with the NET229 pocket pagers. The pager is used to send text messages to the staff showing them the precise location where assistance is required. It can be configured to work as an on-site paging system with connections to a PC or telephone system. It is supplied with RS232 interface unit connection lead and wave aerial.The Nursecall System helps patients and staff to relax in the knowledge that should help be required either by the patient or by a member of staff assistance can be directed to the specific room at the touch of a button. GBP 1296.00 1
SAS RED228 Alphanumeric Paging Transmitter with Aerial SAS RED228 Alphanumeric Paging Transmitter with AerialAn alphanumeric paging transmitter used in conjunction with the RED229 pocket pagers. The pager is used to send text messages to the response staff showing them the precise location where assistance is required. It can be configured in many different ways for example allowing only the highest priority alarm calls to be paged or to link several Red Alert systems via a common paging system. It can also be configured to work as an on-site paging system with connections to a PC or telephone system. It is supplied with RS232 interface unit connection lead and aerial.The Red Alert system helps staff feel more secure knowing that in an emergency they can summon assistance at the touch of a button on their personal transmitter. GBP 1296.00 1
SAS NET255M External Mounting Call Point With Manual Reset SAS NET255M External Mounting Call Point WithManual ResetIdeal when a nurse call point is required in an outdoor environment for example a garden or a patio area. A large green push button is used to call for assistance and another button resets the call. GBP 234.90 1
SAS NET255 External Mounting Call Point With Magnetic Reset SAS NET255 External Mounting Call Point With Magnetic ResetIdeal when a nurse call point is required in an outdoor environment for example a garden or a patio area. A large green push button is used to call for assistance and another button resets the call. GBP 234.90 1
SAS NET235 Printer Package SAS NET235 Printer PackageThe printer enables senior staff to monitor each and every call alarm and reset. The date and time of each event is recorded for future review. The printer has an on board battery in case of mains failure. The printer package also includes a plug top power supply RS232 port spare rolls of paper and a spare printer ribbon.The Nursecall System helps patients and staff to relax in the knowledge that should help be required either by the patient or by a member of staff assistance can be directed to the specific room at the touch of a button. GBP 648.00 1
SAS NET218 Door Monitoring Unit with Key Switch for Isolation Reset SAS NET218 Door Monitoring Unit with Key Switch for Isolation ResetLocated adjacent to doors or drug cabinets these units generate an alarm call if the door is breached. A key switch is provided to isolate the door monitor when a door needs to be opened the same key is used to reset following activation. A red reassurance light shows its status. A timed override feature is provided to allow staff to exit a door without it activating. This can be done by a simple magnetic key swipe see NET216 staff key or if a higher level of security is required by a coded access keypad.The Nursecall System helps patients and staff to relax in the knowledge that should help be required either by the patient or by a member of staff assistance can be directed to the specific room at the touch of a button. GBP 115.84 1
SAS RED290 Charger for Curo SAS RED290 Charger for CuroThe RED290 is a charger designed for use with the SAS Curo. GBP 32.40 1
SAS RED2081 Single Alarm Infrared Unit SAS RED2081 Single Alarm Infrared UnitThe original transmitters from SAS. The RED2081 alarm transmitter is battery operated and incorporates a red alarm button and a clothing clip with pull activation for emergency calls. It can be tested using our RED2501 test station.The RED2092 is a reset transmitter. It has a blue reset signal button and a clothing clip with pull activation for emergence calls.The RED208T is a test transmitter. It has a white button and is used by staff to periodically test the infra-red receivers. Activating the transmitter in the vicinity of a receiver causes its LED to flash proving that it is working correctly. GBP 97.20 1
SAS RED2092 Single Reset Infrared Unit SAS RED2092 Single Reset Infrared UnitThe original transmitters from SAS. The RED2081 alarm transmitter is battery operated and incorporates a red alarm button and a clothing clip with pull activation for emergency calls. It can be tested using our RED2501 test station.The RED2092 is a reset transmitter. It has a blue reset signal button and a clothing clip with pull activation for emergency calls.The RED208T is a test transmitter. It has a white button and is used by staff to periodically test the infra-red receivers. Activating the transmitter in the vicinity of a receiver causes its LED to flash proving that it is working correctly. GBP 97.20 1
SAS RED200 12-24V DC Infrared Receiver with Relay Output Stand Alone Non-Addressable SAS RED200 12-24V DC Infrared Receiver with Relay Output Stand Alone Non-AddressableIt is similar in appearance to the RED205 sensor and has been designed to operate as a stand-alone sensor. This means that with a supply voltage between 12 and 24 volt d.c. to power it any activation by a transmitter from our range will activate an on-board relay. These sensors are used to integrate with other call systems providing them with the flexibility of infra-red technologyThe Red Alert system helps staff feel more secure knowing that in an emergency they can summon assistance at the touch of a button on their personal transmitter. GBP 97.20 1
SAS ReconRED208 Reconditioned RED208 Infrared Unit SAS ReconRED208 Reconditioned RED208 Infrared UnitThe ReconRED208 is a Reconditioned RED208 Infrared Unit.Carried by staff in establishments where they may feel at risk of an attack or who might need to call for urgent assistance. An alarm button is used to unobtrusively activate an alarm call on the nearest infra-red sensor. Pulling the transmitter away from its clothing clip activates an attack call. The unit is battery operated and it is easily replaced by the user. IA button is provided to check the battery health indicated by an LED array on the transmitter furthermore the nearest infra-red sensors reassurance light will flash to confirm a healthy signal. This is a confidence inspiring feature for the user who can quickly test the transmitter and sensors function in an environment when dealing with a potentially serious situation. All transmitters have a serial number and the facility to personalise the label.The Red Alert system helps staff feel more secure knowing that in an emergency they can summon assistance at the touch of a button on their personal transmitter. GBP 64.80 1