SAS NET234 Data Store Software SAS NET234 Data Store SoftwareThe software package enables all events on the Network II system to be logged on a PC. The date time location and type of alarm call will be recorded along with reset and fault reports. A dedicated PC and printer are not required and the programme can be minimised and run in the background.Key FeaturesIt is possible to print selected data using the PCs own printer.The information displayed can be filtered to only shown the data you are currently interested in i.e. all logged information for 1st floor bedroom 6.An alert popup window or sound can be set to inform you of a new event.The colours of the text background and font can be altered to suit your requirements.Personal details can be entered for identification in the log i.e. family contact details or drugs information.The Nursecall System helps patients and staff to relax in the knowledge that should help be required either by the patient or by a member of staff assistance can be directed to the specific room at the touch of a button. GBP 729.00 1
SAS RED234 Datastore Software Package with RS232 Port with 3m Lead SAS RED234 Datastore Software Package with RS232 Port with 3m LeadThe software package enables all events on the Red Alert system to be logged on a PC. The date time location and type of alarm call will be recorded along with reset and fault reports. A dedicated PC and printer are not required and the programme can be minimised and run in the background.The Red Alert system helps staff feel more secure knowing that in an emergency they can summon assistance at the touch of a button on their personal transmitter.Key FeaturesIt is possible to print selected data using the PCs own printer.The information displayed can be filtered to only shown the data you are currently interested in i.e. all logged information for CONSULTING ROOM 2.An alert popup window or sound can be set to inform you of a new event.The colours of the text background and font can be altered to suit your requirements.Personal details can be entered for each identification in the log i.e. response procedures access requirements etc. GBP 567.00 1
SAS RED2086RF Radio Curo Alarm Unit SAS RED2086RF Radio Curo Alarm UnitThe RED2086RF is a Radio Curo Alarm Unit.The RED2086 alarm transmitter is carried by staff in establishments where they may feel at risk of an attack or might need to call for urgent assistance. This is our latest design of infra-red transmitter and it is powered a rechargeable battery.A full charge will last for months rather than weeks and a quick 2 hours is all it takes to get it back to a fully charged state.The transmitter incorporates a red alarm button and a unique emergency call pull activation that keeps the transmitter attached to your person.A pair of side buttons is provided to give a double action switch. A green button is pressed to check the battery condition indicated by an LED furthermore the nearest infra-red receivers reassurance light will flash to confirm a healthy signal.This is a confidence inspiring feature for the user who can quickly test the transmitter and receivers function when dealing with a potentially serious situation.As further backup a bleep will be heard from the transmitter when a battery requires a quick charge.The RED2096 reset transmitter has the same features as the alarm transmitter but has a blue button that is used to cancel alarm calls at their origin. This important feature means that calls must be dealt with by visiting the area of activation. GBP 153.90 1
SAS RED2086 Curo Alarm Unit SAS RED2086 Curo Alarm UnitThe RED2086 alarm transmitter is carried by staff in establishments where they may feel at risk of an attack or might need to call for urgent assistance. This is our latest design of infra-red transmitter and it is powered a rechargeable battery.A full charge will last for months rather than weeks and a quick 2 hours is all it takes to get it back to a fully charged state.The transmitter incorporates a red alarm button and a unique emergency call pull activation that keeps the transmitter attached to your person.A pair of side buttons is provided to give a double action switch. A green button is pressed to check the battery condition indicated by an LED furthermore the nearest infra-red receivers reassurance light will flash to confirm a healthy signal.This is a confidence inspiring feature for the user who can quickly test the transmitter and receivers function when dealing with a potentially serious situation.As further backup a bleep will be heard from the transmitter when a battery requires a quick charge.The RED2096 reset transmitter has the same features as the alarm transmitter but has a blue button that is used to cancel alarm calls at their origin. This important feature means that calls have to be dealt with by visiting the area of activation. GBP 113.40 1
SAS RED2096 Curo Reset Unit SAS RED2096 Curo Reset UnitThe RED2086 alarm transmitter is carried by staff in establishments where they may feel at risk of an attack or might need to call for urgent assistance. This is our latest design of infra-red transmitter and it is powered a rechargeable battery. A full charge will last for months rather than weeks and a quick 2 hours is all it takes to get it back to a fully charged state. The transmitter incorporates a red alarm button and a unique emergency call pull activation that keeps the transmitter attached to your person. A pair of side buttons is provided to give a double action switch. A green button is pressed to check the battery condition indicated by an LED furthermore the nearest infra-red receivers reassurance light will flash to confirm a healthy signal. This is a confidence inspiring feature for the user who can quickly test the transmitter and receivers function when dealing with a potentially serious situation. As further backup a bleep will be heard from the transmitter when a battery requires a quick charge.The RED2096 reset transmitter has the same features as the alarm transmitter but has a blue button that is used to cancel alarm calls at their origin. This important feature means that calls have to be dealt with by visiting the area of activation. GBP 113.40 1
SAS Caring Technology Touch-Wireless-CP Touch Wireless Call Point with Call Level No Reset SAS Caring Technology Touch-Wireless-CP Touch Wireless Call Point with CallLevel No ResetDesigned for challenging environments. The room unitmanufactured from injection molded Tritan Tx more resilient thanPolycarbonate is low profile and vandal resistant. The unit is touch buttonactuated and any of the above configuration of active buttons can be achieved.The patient touches the area denoted by the orange paddle to activate a patientcall. The hidden LED in the centre of the call point illuminates red when thebuttons are touched. A low battery warning will sound when the battery is low.Upon detection of a low battery a CALL signal is sent out this will not besent again until the battery has been changed. While the room units battery islow it will continue to flash its red LED every 15 seconds and sound its buzzerevery 2 minutes. Staff should be made aware of this. The buttons in the framestaff only can be used by the nurse to reset the call. Included 2x torx M3.5x 25mm security screws 3 x AAA batteries surface back box optionalThe wireless call points are a cost-effectiveapproach to add nurse call to an existing staff attack system. This helps keepdisruption to a minimum since no walls need to be chased and are easilyinstalled with an anti-ligature surface collar. The slave wireless call pointsyncs with a master IR receiver which is addressed to understand its location. GBP 186.30 1
SAS Caring Technology Touch-Wireless-CP-RU Touch Wireless Call Point with Call Reset Crash And Alarm Levels SAS Caring Technology Touch-Wireless-CP-RU Touch Wireless Call Point with Call Reset Crash And Alarm LevelsDesigned for challenging environments. The room unit manufactured from injection molded Tritan Tx more resilient than Polycarbonate is low profile and vandal resistant. The unit is touch button actuated and any of the above configuration of active buttons can be achieved. The patient touches the area denoted by the orange paddle to activate a patient call. The hidden LED in the centre of the call point illuminates red when the buttons are touched. A low battery warning will sound when the battery is low. Upon detection of a low battery a CALL signal is sent out this will not be sent again until the battery has been changed. While the room units battery is low it will continue to flash its red LED every 15 seconds and sound its buzzer every 2 minutes. Staff should be made aware of this. The buttons in the frame staff only can be used by the nurse to reset the call. Included 2x torx M3.5 x 25mm security screws 3 x AAA batteries surface back box optionalThe wireless call points are a cost effective approach to add nurse call to an existing staff attack system. This helps keep disruption to a minimum since no walls need to be chased and are easily installed with an anti-ligature surface collar. The slave wireless call point syncs with a master IR receiver which is addressed to understand its location.LED FunctionGreen Battery goodYellow Battery should be changedRed Change battery nowPlease note The image is for illustrative purposes only. GBP 202.50 1
SAS Caring Technology Touch-Wireless-CP-R Touch Wireless Call Point with Call Reset Reset And Test Levels SAS Caring Technology Touch-Wireless-CP-R Touch Wireless Call Point with Call Reset Reset And Test LevelsDesigned for challenging environments. The room unit manufactured from injection molded Tritan Tx more resilient than Polycarbonate is low profile and vandal resistant. The unit is touch button actuated and any of the above configuration of active buttons can be achieved. The patient touches the area denoted by the orange paddle to activate a patient call. The hidden LED in the centre of the call point illuminates red when the buttons are touched. A low battery warning will sound when the battery is low. Upon detection of a low battery a CALL signal is sent out this will not be sent again until the battery has been changed. While the room units battery is low it will continue to flash its red LED every 15 seconds and sound its buzzer every 2 minutes. Staff should be made aware of this. The buttons in the frame staff only can be used by the nurse to reset the call. Included 2x torx M3.5 x 25mm security screws 3 x AAA batteries surface back box optionalThe wireless call points are a cost effective approach to add nurse call to an existing staff attack system. This helps keep disruption to a minimum since no walls need to be chased and are easily installed with an anti-ligature surface collar. The slave wireless call point syncs with a master IR receiver which is addressed to understand its location.LED FunctionGreen Battery goodYellow Battery should be changedRed Change battery nowPlease note The image is for illustrative purposes only. GBP 186.30 1
SAS Caring Technology Touch-Wireless-CP-ATT Touch Wireless Call Point with Attack Level No Reset SAS Caring Technology Touch-Wireless-CP-ATT Touch Wireless Call Point with Attack Level No ResetDesigned for challenging environments. The room unit manufactured from injection molded Tritan Tx more resilient than Polycarbonate is low profile and vandal resistant. The unit is touch button actuated and any of the above configuration of active buttons can be achieved. The patient touches the area denoted by the orange paddle to activate a patient call. The hidden LED in the centre of the call point illuminates red when the buttons are touched. A low battery warning will sound when the battery is low. Upon detection of a low battery a CALL signal is sent out this will not be sent again until the battery has been changed. While the room units battery is low it will continue to flash its red LED every 15 seconds and sound its buzzer every 2 minutes. Staff should be made aware of this. The buttons in the frame staff only can be used by the nurse to reset the call. Included 2x torx M3.5 x 25mm security screws 3 x AAA batteries surface back box optionalThe wireless call points are a cost effective approach to add nurse call to an existing staff attack system. This helps keep disruption to a minimum since no walls need to be chased and are easily installed with an anti-ligature surface collar. The slave wireless call point syncs with a master IR receiver which is addressed to understand its location.LED FunctionGreen Battery goodYellow Battery should be changedRed Change battery nowPlease note The image is for illustrative purposes only. GBP 186.30 1