Pepperl amp Fuchs KCD0-SD3-EX1.1045 Solenoid Driver Pepperl Fuchs KCD0-SD3-EX1.1045 Solenoid DriverThis isolated barrier is used for intrinsic safety applications. It supplies power to solenoids LEDs and audible alarms located in a hazardous area. It is loop powered so the available energy at the output is received from the input signal. The output signal has a resistive characteristic. As a result the output voltage and current are dependent on the load and the input voltage. At full load 11 V at 80 mA is available for the hazardous area application.Details2-channel isolated barrier24 V DC supply loop poweredOutput 45 mA at 12 V DCTest pulse immunityHousing width 12.5mmUp to SIL 3 acc. to IECEN 61508 GBP 193.61 1
Pepperl amp Fuchs KFD0-SD2-EX2.1545 Solenoid Driver Pepperl Fuchs KFD0-SD2-EX2.1545 Solenoid DriverThis isolated barrier is used for intrinsic safety applications. It supplies power to solenoids LEDs and audible alarms located in a hazardous area. It is loop powered so the available energy at the output is received from the input signal. The output signal has a resistive characteristic. As a result the output voltage and current are dependent on the load and the input voltage. At full load 11 V at 80 mA is available for the hazardous area application.Details2-channel isolated barrier24 V DC supply loop poweredOutput 45 mA at 12 V DCTest pulse immunityUp to SIL 3 acc. to IECEN 61508 GBP 362.21 1
Pepperl Fuchs KCD0-SD3-EX1.1245 Solenoid Driver Pepperl Fuchs KCD0-SD3-EX1.1245 Solenoid DriverThis isolated barrier is used for intrinsic safety applications.The device supplies power to solenoids LEDs and audible alarms located in a hazardous area.The device is loop powered so the available energy at the output is received from the input signal. The output signal has a resistive characteristic. As a result the output voltage and current are dependent on the load and the input voltageAt full load 12 V at 45 mA is available for the hazardous area application.Key Features1-channel isolated barrier24 V DC supply loop poweredCurrent limit 45 mA at 12 V DCTest pulse immunityHousing width 12.5 mmUp to SIL 3 acc. to IECEN 61508 GBP 240.50 1
Pepperl amp Fuchs KCD2-SLD-EX1.1065 Solenoid Driver Pepperl Fuchs KCD2-SLD-EX1.1065 Solenoid DriverThis isolated barrier is used for intrinsic safety applications. It supplies power to solenoids LEDs and audible alarms located in a hazardous area. The device is controlled with a loop powered signal or a bus powered logic signal. The device is immune to the test pulses of various control systems. The device simulates a minimum load at the input. The minimum load can be activated and de-activated. The line fault transparency function can display a line fault in the field by a change in impedance at the switching input of the solenoid driver. A line fault is indicated by a red LED and output via the fault indication output or a switch contact.Key Features1-channel isolated barrier24 V DC supply bus or loop poweredOutput 65 mA at 10 V DCLine fault transparency LFTTest pulse immunityHousing width 12.5 mmUp to SIL 3 acc. to IECEN 61508 GBP 341.28 1