Patol 710-053 Metal Air Purge Blower 5051 230Vac Patol 710-053 Metal Air Purge Blower 5051 230VacA metal air purge blower 5051.Key Features230Vac GBP 887.04 1
Patol 710-217 Sensor 5730 ABS Metal Air Purge Blower 5051 230vac 2m Air Hose Patol 710-217 Sensor 5730 ABS Metal Air Purge Blower 5051 230vac 2m Air HoseA sensor 5730 ABSMetal Air Purge Blower 5051 230vac and 2m Air Hose. GBP 4378.08 1
Patol 710-040 Air Purge Unit 5040 230vac Patol 710-040 Air Purge Unit 5040 230vacThe 5040 Air Purge Unit is a single and multistage centrifugal blower that can be provided in a variety of configurations that accommodate differing application requirements such as air delivery volumepressure supply voltage and mounting arrangements. Where a suitable on site air supply is not readily available the Patol 5000 Series air purge units may be employed.The unit is provided with a 2m flexible supply cable for connection at an adjacent junction box.Some units are equipped with an easily removable and washable air filter however these filters are intended to preserve blower life in normal conditions.The blower should either be installed outside a dirtydusty area or the unit inlet piped to a clean air environment. Intermediate rigid ducting is most readily achieved by the use of standard PVC pipes and fittings.Key FeaturesMaterial Fan Case - White Polyester Resin Impellors - Aluminium 1200 H14IP Rating IP44Weight 8.5Kg GBP 1770.72 1
Patol 710-041 Air Purge Unit 5041 115vac Patol 710-041 Air Purge Unit 5041115vacThe 5041 Air Purge Unit is a single and multistage centrifugal blower that can be provided in a variety of configurations that accommodate differing application requirements such as air delivery volumepressure supply voltage and mounting arrangements. Where a suitable on site air supply is not readily available the Patol 5000 Series air purge units may be employed.The unit is provided with a 2m flexible supply cable for connection at an adjacent junction box.Some units are equipped with an easily removable and washable air filter however these filters are intended to preserve blower life in normal conditions.The blower should either be installed outside a dirtydusty area or the unit inlet piped to a clean air environment. Intermediate rigid ducting is most readily achieved by the use of standard PVC pipes and fittings.Key FeaturesMaterial Fan Case - White Polyester Resin Impellors - Aluminium 1200 H14IP Rating IP44Weight 8.5KgCompatible with Infra-red Transit Heat Sensor GBP 1770.72 1
Patol 4041F Air Purge Filter for 50405041 Patol 4041F Air Purge Filter for 50405041A replacement air purge filter for the 50405041 Air Purge Units.Air purge filters are intended to preserve blower life in normal conditions. They can be easily removed from an Air Purge Unit and are washable. GBP 126.00 1
Patol 5730 Infrared High Temperature Heat Sensor 115vAC Patol 5730 Infrared High Temperature Heat Sensor 115vACThe 5730 High Temperature Transit Flame Sensor monitors high temperature materials up to 240 on highest sensitivity being transported on conveyor systems at speeds of between 0.5 and 6ms and triggers as the material reaches the ember or flame condition.The sensor employs enhanced infra-red monitoring technology that analysis the levels of IR emission in the narrow band of 4.2-4.7m. As the sensor is tuned to this band it is solar blind meaning the background and transient IR spectra are discriminated. This provides enhanced false alarm immunity. Air purging from a mains operated Air Purged Blower APB air feed is used to maintain a positive air pressure in the sensor enclosure and ensures the prevention of dust settling on the sensor window. The air supply is monitored by a pressure switch which on air failure is signalled as a faultstatus. The 5730 incorporates within the unit a series of user programmable DIL switches. Option selection including detector sensitivity settings automanual reset sequence selection and single coincidence voting from the four individual internal detection channels for the alarm trip and shutdown outputs. The sensor air pressure and signal cable connections are fault monitored and fail safe. The controller incorporates an aux. fault input common fault output contact. GBP 5241.60 1
Patol 710-207 5730 Infrared High Temperature Heat Sensor 230vAC Patol 710-207 5730 Infrared High Temperature Heat Sensor 230vACThe 5730 High Temperature Transit Flame Sensor monitors high temperature materials up to 240 on highest sensitivity being transported on conveyor systems at speeds of between 0.5 and 6ms and triggers as the material reaches the ember or flame condition.The sensor employs enhanced infra-red monitoring technology that analysis the levels of IR emission in the narrow band of 4.2-4.7m. As the sensor is tuned to this band it is solar blind meaning the background and transient IR spectra are discriminated. This provides enhanced false alarm immunity. Air purging from a mains operated Air Purged Blower APB air feed is used to maintain a positive air pressure in the sensor enclosure and ensures the prevention of dust settling on the sensor window. The air supply is monitored by a pressure switch which on air failure is signalled as a fault status.The 5730 incorporates within the unit a series of user programmable DIL switches. Option selection including detector sensitivity settings automanual reset sequence selection and single coincidence voting from the four individual internal detection channels for the alarm trip and shutdown outputs. The sensor air pressure and signal cable connections are fault monitored and fail safe. The controller incorporates an aux. fault input common fault output contact. GBP 5241.60 1
Patol 720-212 High Temp Heat amp Flame Sensor 5730 ABS incl Mounting Bracket Patol 720-212 High Temp Heat Flame Sensor 5730 ABS Including Mounting BracketThe 5730 High Temperature Transit Flame Sensor monitors high temperature materials up to 240 on highest sensitivity being transported on conveyor systems at speeds of between 0.5 and 6ms and triggers as the material reaches the ember or flame condition.The sensor employs enhanced infra-red monitoring technology that analysis the levels of IR emission in the narrow band of 4.2-4.7m. As the sensor is tuned to this band it is solar blind meaning the background and transient IR spectra are discriminated. This provides enhanced false alarm immunity.Air purging from a mains operated Air Purged Blower APB air feed is used to maintain a positive air pressure in the sensor enclosure and ensures the prevention of dust settling on the sensor window. The air supply is monitored by a pressure switch which on air failure is signalled as a fault status.The 5730 incorporates within the unit a series of user programmable DIL switches. Option selection including detector sensitivity settings automanual reset sequence selection and single coincidence voting from the four individual internal detection channels for the alarm trip and shutdown outputs.The sensor air pressure and signal cable connections are fault monitored and fail safe. The controller incorporates an auxiliary fault input and common fault output contact.Key FeaturesDetection of ember and flame of high temperature productAir purged system for dusty environments with air pressure monitoringFour Channels of Isolated Detectors for maximum reliabilitySingle Coincidence voting outputTimed auto reset coincidence analyser circuitTuned response solar blindVoting Logic Latching optionsAlarm Trip FunctionsFault Monitored with Test Reset push ButtonsField ProgrammableLocal IndicatorsComes with a Mounting Bracket GBP 3642.24 1
Patol Infra-Red Heat Sensor 5410 ABS cw Mounting Bracket 720-012 Patol Infra-Red Heat Sensor 5410 ABS cw Mounting Bracket 720-012The 5000 Series is an early warning infra-red transit heat sensor which can trigger at temperatures as low as 100C when monitoring materials being transported on conveyor systems before they have reached the ember or flame condition.Its unique dual detector enhanced Infra-red monitoring has been created to detect black heat. Black body emissions occur for all material the sensor is designed to detect a change in these emissions even at relatively low temperatures when the material moves through its field of view.Air purging from a mains operated Air Purged Blower APB feed is used to maintain a positive air pressure in the sensor enclosure and ensures the prevention of dust settling on the sensor window.The air supply is monitored by a pressure switch which on air failure is signalled as a fault status.The 5410 incorporates within the unit a series of user programmable SIL switches. Option selection including detector sensitivity settings automanual reset sequence selection and single coincidence voting from the two individual internal detectors for the alarm trip and shutdown outputs.The sensor air pressure and signal cable connections are fault monitored and fail safe. The controller incorporates an aux. fault input common fault output contact.Key FeaturesDetection of hazards at temperatures below flame point including both embers and buried hot spotsAir purged system for dusty environments with air pressure monitoringTwin high integrity detection circuit channels for maximum reliabilityTwo wire operation - Powered by direct connection to standard fire trigger circuits or addressable loop interfaceSingle Coincidence voting outputTimed auto reset coincidence analyser circuitTuned response solar blindVolt free relay contact output operation selectable as standardFault Monitored with Test Reset push buttonsField Programmable GBP 3642.24 1