Patol 700-575 EOL Terminator Box Without Test Switch To Suit DDL DIM28 Stainless Steel Patol 700-575 EOL Terminator Box Without Test Switch To Suit DDL DIM28 Stainless SteelAn EOL Terminator Box without Test Switch to suit DDL DIM28Key FeaturesStainless Steel GBP 431.76 1
Patol 700-573 EOL Terminator Box With Test To Suit DDL DIM28 - Cast Aluminium 10k Patol 700-573 EOL Terminator Box With Test To Suit DDL DIM28 - Cast Aluminium 10kAn EOL Terminator Box with Test to suit DDL DIM28 - Cast Aluminium 10k GBP 378.00 1
Patol 5000 Series IR Heat Wand Test Equipment Patol 5000 Series IR Heat Wand Test EquipmentPatols Infrared heat wand is used to test and commission the 5000 series sensors. The wand uses a rapid controllable thermal energy that provides no visible sign of heat by producing black body Infrared emissions.The Patol wand is passed underneath the detectors field of view triggering an alarm. It comes complete with a metal cage to protect users and surfaces.Key FeaturesDiameter 95mm Heating ElementTemperature Approx. 350CVoltage 230VacPlug 3 pin GB plug GBP 235.63 1
Patol 700-574 EOL Terminator Box With Fire amp Fault Test Key Switch To Suit DDL DIM Patol 700-574 EOL Terminator Box With Fire Fault Test Key Switch To Suit DDL DIMAn EOL Terminator Box with Fire Fault Test Key Switch to suit DDL DIM. GBP 710.64 1
Patol 700-576 EOL Terminator Box With Fire amp Fault Test Key Switch To Suit DDL DIM Patol 700-576 EOL Terminator Box With Fire Fault Test Key Switch To Suit DDL DIMAn EOL Terminator Box with Fire Fault Test Key Switch to suit DDL DIM. GBP 341.04 1
Patol LHDC 1 Meter Commissioning amp Maintenance Test Oven Patol LHDC 1 Meter Commissioning Maintenance Test OvenCommissioning and routine maintenance testing of the Patol Analogue Linear Heat Detection Cable systems can be conducted at site using a calibrated 1 metre test oven.The portable 1 metre test oven concept of testing allows accessible one metre installed lengths of sensor cable to be subjected to temperatures within the alarm range. Thus confirming correct calibration setting selection and alarm levels in accordance with project specification requirements.Where sensor cable is installed within hazardous classified areas or may be inaccessible for oven use an additional one metre length may be series wired with existing cable sensor andor interconnecting cables to allow testing to be carried out local to the electronic interface unit in the safe area. Without adversely affecting system performance levels.Key FeaturesDimensions 1070 x 150 x 130mmWeight 13.55kgOperating Voltage 230115V ac fuse rated 10ATemperature Range 0C to 200CMaterial Rugged Aluminium GBP 5196.24 1
Patol 700-520 Digital EOL Terminator Box without Test Switch Stainless Steel Patol 700-520 Digital EOL Terminator Box without Test Switch Stainless SteelAn End of Line terminator box without test facility for use with the Patol DIM digital LHDC monitors.The Patol End Of Line EOL junction boxes are designed to terminate either Analogue and Digital LHDC. The EOL unit provides fault monitoring on the cable.Digital EOLs monitor for open circuit faults.Key FeaturesStainless steelIP Rating IP65 GBP 415.30 1
Patol 700-519 Digital EOL Terminator Box without Test Switch Stainless Steel Patol 700-519 Digital EOL Terminator Box without Test Switch Stainless SteelAn End of Line terminator box with test facility for use with the Patol DIM digital LHDC monitors.The Patol End Of Line EOL junction boxes are designed to terminate either Analogue and Digital LHDC. The EOL unit provides fault monitoring on the cable.Digital EOLs monitor for open circuit faults.Key FeaturesStainless steelIP Rating IP65 GBP 415.30 1
Patol 700-513 Digital EOL Terminator Box with Test to Suit DDL - Cast Aluminium Patol 700-513 Digital EOL Terminator Box with Test to Suit DDL - Cast AluminiumAn End of Line terminator box with test facility for use with the Patol DDL digital LHDC monitors.The Patol End Of Line EOL junction boxes are designed to terminate either Analogue and Digital LHDC. The EOL unit provides fault monitoring on the cable.Analogue EOL units can monitor for both open and closed circuit faults. Digital EOLs monitor for open circuit faults.Key FeaturesCast aluminiumIP Rating IP66 GBP 362.64 1
Patol 700-514 Digital EOL Terminator Box with Test to suit DIM - Cast Aluminium Patol 700-514 Digital EOL Terminator Box with Test to suit DIM - Cast AluminiumAn End of Line terminator box with test facility for use with the Patol DIM digital LHDC monitors.The Patol End Of Line EOL junction boxes are designed to terminate either Analogue and Digital LHDC.The EOL unit provides fault monitoring on the cable. Analogue EOL units can monitor for both open and closed circuit faults. Digital EOLs monitor for open circuit faults.Key FeaturesCast aluminiumIP Rating IP66 GBP 362.64 1
Patol Analogue EOL ABS Termination Box with Fire amp Fault Test Key Switch Patol Analogue EOL ABS Termination Box with Fire Fault Test Key SwitchThe Patol End of Line EOL junction boxes are designed to terminate either Analogue and Digital LHDC. The EOL unit provides fault monitoring on the cable. Analogue EOL units can monitor for both open and closed circuit faults. Digital EOLs monitor for open circuit faults.Key FeaturesABS PlasticIP66120mm x 120mm x 80mm1 x PG7 Gland GBP 329.28 1
Patol 700-511 Analogue EOL Terminator Box with Test - Cast Aluminium Patol 700-511 Analogue EOL Terminator Box with Test - Cast AluminiumThe Patol End of Line EOL junction boxes are designed to terminate either Analogue and Digital LHDC. The EOL unit provides fault monitoring on the cable. Analogue EOL units can monitor for both open and closed-circuit faults. Digital EOLs monitor for open circuit faults.Analogue LHDC is designed to provide early detection of fire and overheating in circumstances where other forms of detection would not be viable either due to inability to sustain the environmental requirements or through prohibitive costs.Key FeaturesIP Rating IP66Cast Aluminium GBP 378.00 1
Patol Analogue EOL Stainless Steel Termination Box with Fire amp Fault Test Key Switch Patol Analogue EOL Stainless Steel Termination Box with Fire Fault Test Key SwitchThe Patol End of Line EOL junction boxes are designed to terminate either Analogue and Digital LHDC. The EOL unit provides fault monitoring on the cable. Analogue EOL units can monitor for both open and closed circuit faults. Digital EOLs monitor for open circuit faults.Key FeaturesStainless Steel 316IP65126mm x 126mm x 80mm1 x M16 Stainless Steel Gland GBP 710.64 1
Patol Digital EOL ABS Termination Box for DIM Range with Fire amp Fault Test Key Switch Patol Digital EOL ABS Termination Box for DIM Range with Fire Fault Test Key SwitchThe Patol End of Line EOL junction boxes are designed to terminate either Analogue and Digital LHDC. The EOL unit provides fault monitoring on the cable. Analogue EOL units can monitor for both open and closed circuit faults. Digital EOLs monitor for open circuit faults.Key FeaturesABS PlasticIP66120mm x 120mm x 80mm1 x PG7 Gland GBP 328.03 1
Patol Digital EOL ABS Termination Box for DDL Range with Fire amp Fault Test Key Switch Patol Digital EOL ABS Termination Box for DDL Range with Fire Fault Test Key SwitchThe Patol End of Line EOL junction boxes are designed to terminate either Analogue and Digital LHDC. The EOL unit provides fault monitoring on the cable. Analogue EOL units can monitor for both open and closed circuit faults. Digital EOLs monitor for open circuit faults.Key FeaturesABS PlasticIP66120mm x 120mm x 80mm1 x PG7 Gland GBP 328.03 1
Patol 700-518 Analogue EOL Terminator Box without Test Switch - Stainless Steel 316 Patol 700-518 Analogue EOL Terminator Box without Test Switch - Stainless Steel 316The Patol End of Line EOL junction boxes are designed to terminate either Analogue and Digital LHDC. The EOL unit provides fault monitoring on the cable. Analogue EOL units can monitor for both open and closed-circuit faults. Digital EOLs monitor for open circuit faults.Analogue LHDC is designed to provide early detection of fire and overheating in circumstances where other forms of detection would not be viable either due to inability to sustain the environmental requirements or through prohibitive costs.Key FeaturesIP Rating IP65Stainless steel GBP 431.76 1
Patol Digital EOL Stainless Steel Termination Box for DIM Range with Fire amp Fault Test Key Switch Patol Digital EOL Stainless Steel Termination Box for DIM Range with Fire Fault Test Key SwitchThe Patol End of Line EOL junction boxes are designed to terminate either Analogue and Digital LHDC. The EOL unit provides fault monitoring on the cable. Analogue EOL units can monitor for both open and closed circuit faults. Digital EOLs monitor for open circuit faults.Key FeaturesStainless Steel 316IP65126mm x 126mm x 80mm1 x M16 Stainless Steel Gland GBP 683.09 1
Patol Digital EOL Stainless Steel Termination Box for DDL Range with Fire amp Fault Test Key Switch Patol Digital EOL Stainless Steel Termination Box for DDL Range with Fire Fault Test Key SwitchThe Patol End of Line EOL junction boxes are designed to terminate either Analogue and Digital LHDC. The EOL unit provides fault monitoring on the cable. Analogue EOL units can monitor for both open and closed circuit faults. Digital EOLs monitor for open circuit faults.Key FeaturesStainless Steel 316IP65126mm x 126mm x 80mm1 x M16 Stainless Steel Gland GBP 683.09 1
Patol 700-005LS0H FRPE Red Analogue Resettable LHDC Chemical amp UV Resistant - Stainless Steel Braid Patol 700-005LS0H FRPE Red Analogue Resettable LHDC Chemical UV Resistant - Stainless Steel BraidAFRPE Red Analogue Resettable LHDC Chemical UV Resistant with stainless steel braid. For use with the Resettable Analogue LHDC 1m Portable Test Oven.Commissioning and routine maintenance testing of the Patol Resettable Analogue Linear Heat Detection Cable systems can be conducted at site by the use of a calibrated One Metre Test Oven.The portable One Metre Test Oven concept of testing allows accessible one metre installed lengths of sensor cable to be subjected to temperatures within the Alarm range. Thus confirming correct calibration setting selection and Alarm levels in accordance with project specification requirements.Where sensor cable is installed within hazardous classified areas or may be inaccessible for oven use an additional one metre length may be series wired with existing cable sensor and or interconnecting cables to allow testing to be carried out local to the electronic interface unit in the safe area. Without adversely affecting system performance levels. GBP 10.58 1
Patol Digital LDM-519-DIM Din Rail Mounted LHDC Monitor 2km Patol Digital LDM-519-DIM Din Rail Mounted LHDC Monitor 2kmThe LDM-519-DIM module is designed to monitor a length of Digital Linear Heat Detection Cable LHDC for both a fire condition and fault status open circuit. The DIM module is certified to be fully compatible with SIL 2 certified systems.Digital LHDC may be employed in lengths up to 2Km when using the LDM-519-DIM module. Signalling of fire and fault status is generated by means of volt free contacts.The module has been specifically designed in a DIN rail format to allow it to be used in a variety of discrete housings or integrated multi zone control panels.Patol offer a complete range of special build panels which can incorporate this module for projects that require unique and tailored solutions.Key FeaturesLHDC Hazardous Area use by means of Intrinsically Safe Zener BarrierSIL 2 certifiedFault monitoring of LHDC for open circuit conditionsLED indication of Fire Fault Supply statusIntegral test reset push-buttonsVolt free contact outputs for Fire and Fault conditionsIndicator and control switch connections for local fascia implementationDin rail mounting GBP 654.29 1
Patol Infra-Red Heat Sensor 5610SS Stainless Steel 316 ATEX Approved 722-009 Patol Infra-Red Heat Sensor 5610SS Stainless Steel 316 ATEX ApprovedCompressed Air Lens Clean Purging cw Mounting Bracket 722-009The 5000 Series is an early warning infra-red heat sensor which can trigger at temperatures as low as 100C when monitoring materials being transported on conveyor systems before they have reached the ember or flame condition.Its unique dual detector enhanced Infra-red monitoring has been created to detect black heat. Black body emissions occur for all material the sensor is designed to detect a change in these emissions even at relatively low temperatures when the material moves through its field of view.The 5610SS is specifically designed for hazardous areas and is ATEX approved.Air purging from a compressed air feed is used to maintain a lens cleaning system that ensures the prevention of dust settling on the sensor window.The 5610SS incorporates within the unit a user programmable SIL switch. Option selection includes detector sensitivity settings automanual reset sequence selection and singlecoincidence voting from the two individual internal detectors for the alarm trip shutdown outputs.Key FeaturesCompressed air lens clean purgingStainless steelDetection of hazards at temperatures below flame point including both embers and buried hot spotsATEX approvedTwin high integrity detection circuit channels for maximum reliabilityTwo wire operation - Can be powered by direct connection to standard fire trigger circuits or addressable loop interfaceSingle Coincidence voting outputTimed auto reset coincidence analyser circuitTuned response solar blindVolt free relay contact output operation selectable as standardFault Monitored with Test Reset push ButtonsField Programmable GBP 5770.80 1
Patol 720-212 High Temp Heat amp Flame Sensor 5730 ABS incl Mounting Bracket Patol 720-212 High Temp Heat Flame Sensor 5730 ABS Including Mounting BracketThe 5730 High Temperature Transit Flame Sensor monitors high temperature materials up to 240 on highest sensitivity being transported on conveyor systems at speeds of between 0.5 and 6ms and triggers as the material reaches the ember or flame condition.The sensor employs enhanced infra-red monitoring technology that analysis the levels of IR emission in the narrow band of 4.2-4.7m. As the sensor is tuned to this band it is solar blind meaning the background and transient IR spectra are discriminated. This provides enhanced false alarm immunity.Air purging from a mains operated Air Purged Blower APB air feed is used to maintain a positive air pressure in the sensor enclosure and ensures the prevention of dust settling on the sensor window. The air supply is monitored by a pressure switch which on air failure is signalled as a fault status.The 5730 incorporates within the unit a series of user programmable DIL switches. Option selection including detector sensitivity settings automanual reset sequence selection and single coincidence voting from the four individual internal detection channels for the alarm trip and shutdown outputs.The sensor air pressure and signal cable connections are fault monitored and fail safe. The controller incorporates an auxiliary fault input and common fault output contact.Key FeaturesDetection of ember and flame of high temperature productAir purged system for dusty environments with air pressure monitoringFour Channels of Isolated Detectors for maximum reliabilitySingle Coincidence voting outputTimed auto reset coincidence analyser circuitTuned response solar blindVoting Logic Latching optionsAlarm Trip FunctionsFault Monitored with Test Reset push ButtonsField ProgrammableLocal IndicatorsComes with a Mounting Bracket GBP 3642.24 1
Patol Infra-Red Heat Sensor 5410 ABS cw Mounting Bracket 720-012 Patol Infra-Red Heat Sensor 5410 ABS cw Mounting Bracket 720-012The 5000 Series is an early warning infra-red transit heat sensor which can trigger at temperatures as low as 100C when monitoring materials being transported on conveyor systems before they have reached the ember or flame condition.Its unique dual detector enhanced Infra-red monitoring has been created to detect black heat. Black body emissions occur for all material the sensor is designed to detect a change in these emissions even at relatively low temperatures when the material moves through its field of view.Air purging from a mains operated Air Purged Blower APB feed is used to maintain a positive air pressure in the sensor enclosure and ensures the prevention of dust settling on the sensor window.The air supply is monitored by a pressure switch which on air failure is signalled as a fault status.The 5410 incorporates within the unit a series of user programmable SIL switches. Option selection including detector sensitivity settings automanual reset sequence selection and single coincidence voting from the two individual internal detectors for the alarm trip and shutdown outputs.The sensor air pressure and signal cable connections are fault monitored and fail safe. The controller incorporates an aux. fault input common fault output contact.Key FeaturesDetection of hazards at temperatures below flame point including both embers and buried hot spotsAir purged system for dusty environments with air pressure monitoringTwin high integrity detection circuit channels for maximum reliabilityTwo wire operation - Powered by direct connection to standard fire trigger circuits or addressable loop interfaceSingle Coincidence voting outputTimed auto reset coincidence analyser circuitTuned response solar blindVolt free relay contact output operation selectable as standardFault Monitored with Test Reset push buttonsField Programmable GBP 3642.24 1
Patol N4587A-R01 Fibresense LHD - 1km LHD Interrogator Multimode MM Sensor Patol N4587A-R01 Fibresense LHD - 1km LHD Interrogator Multimode MM SensorThe Linear Heat Detection LHD N45 Series technology detects fire quickly and identifies the location of the fire with maximum accuracy and reliability by using a fibre optic cable as a precise distributed heat sensor.The advanced LHD N45 Series goes far beyond conventional fire detection systems. This technology measures an accurate temperature profile every few seconds along a fibre optic cable up to 16km varies by model. It is unaffected by air currents and hence accurately determines the size and direction of a spreading fire. In large scale infrastructures the sensor cable typically runs through different areas under various temperature conditions. The fibre optic LHD solution lets you configure the appropriate alarm criteria in hundreds of zones along the same cable run regardless of how long your sensor cable actually is. The industrys fastest fire detection and lowest false alarm rate are in balance even under challenging conditions regardless of the application. The system is immune to dirt dust corrosive environments organic vapours extreme temperatures or radiation. Larger facilities have challenging installation and commissioning requirements and higher maintenance efforts. LHD N45 addresses these problems by using a standard fibre optic cable as a precise distributed heat sensor.With LHD N45 Series fire-fighting countermeasures can be used effectively before and throughout the fire event.Ideal for use in infrastructures and buildings such as rail and road tunnels airports mining shafts parking stations and warehouses.Each fibre optic LHD instrument is individually tested before shipping and must pass strict test limits. This ensures that every fibre optic LHD unit will meet or exceed the specifications in this data sheet. Adhering to our stringent quality control measures guarantees optimal performance and a long product life. Key FeaturesLHD InterrogatorMultimode MM Sensor SystemMeasurement Range 1 KmDTS Web Configurator2X LAN2X USBSD10X Relay GBP 27224.40 1
Patol N4587A-R04 Fibresense LHD - 4km LHD Interrogator Multimode MM Sensor Patol N4587A-R04 Fibresense LHD - 4km LHD Interrogator Multimode MM SensorThe Linear Heat Detection LHD N45 Series technology detects fire quickly and identifies the location of the fire with maximum accuracy and reliability by using a fibre optic cable as a precise distributed heat sensor.The advanced LHD N45 Series goes far beyond conventional fire detection systems. This technology measures an accurate temperature profile every few seconds along a fibre optic cable up to 16km varies by model. It is unaffected by air currents and hence accurately determines the size and direction of a spreading fire. In large scale infrastructures the sensor cable typically runs through different areas under various temperature conditions. The fibre optic LHD solution lets you configure the appropriate alarm criteria in hundreds of zones along the same cable run regardless of how long your sensor cable actually is. The industrys fastest fire detection and lowest false alarm rate are in balance even under challenging conditions regardless of the application. The system is immune to dirt dust corrosive environments organic vapours extreme temperatures or radiation. Larger facilities have challenging installation and commissioning requirements and higher maintenance efforts. LHD N45 addresses these problems by using a standard fibre optic cable as a precise distributed heat sensor.With LHD N45 Series fire-fighting countermeasures can be used effectively before and throughout the fire event.Ideal for use in infrastructures and buildings such as rail and road tunnels airports mining shafts parking stations and warehouses.Each fibre optic LHD instrument is individually tested before shipping and must pass strict test limits. This ensures that every fibre optic LHD unit will meet or exceed the specifications in this data sheet. Adhering to our stringent quality control measures guarantees optimal performance and a long product life. Key FeaturesLong range coverageGapless fire detectionPrecise temperature monitoring fast fire detectionContinuously monitors the temperature at every point along the assetRack wall mounted optionUp to 4 channels0.5m spatial resolutionWeb based programming wit state of the art IT security standardsRugged housing design for outdoor and heavy duty applications GBP 35169.12 1