Nursecall Intercall AIRX4 Addressable IR Receiver Legacy Nursecall Intercall AIRX4 Addressable IR Receiver LegacyThe AIRX4 receiver is an addressable IR receiver for use on legacy systems. It is designed to receive signals from the staff activation device in the event of an attack.Key FeaturesInstallation Flush or surface mount in standard single gang electrical back boxSize 80 x 80 x 20 mm GBP 172.13 1
Nursecall Intercall DISP1 LCD Alphanumeric Display Nursecall Intercall DISP1 LCD Alphanumeric DisplayThe DISP1 LCD Corridor Display Unit is the device used to sound the alarm and identify the location of each incident along with the level of assistance required. The display can also show the identity of the staff member calling for assistance.The DISP1 features a two line 16 character back lit LCD display and a multi level adjustable alarm. The unit features different tones for different levels of call as well as having the capability of sounding a different tone for selected call points doors drugs cupboards telephone etc. The DISP1 can also be setup to display specific call points zoning if required.All DISP1 Display Units are identical but each can be configured to operate independently or as a slave display to a master unit.Key FeaturesSize 163 x 115 x 35 mmInstallation Flush mount in standard double gang electrical back box. Surface mount using Intercall BB1 back box GBP 392.45 1
Nursecall Intercall AIRX7 Addressable IR Receiver Nursecall Intercall AIRX7 Addressable IR ReceiverThe Guardian AIRX7 receiver is an addressable IR receiver for use on newer systems. It incorporates the latest HF technology to minimise the disruption caused to the signal transmission by high frequency lighting. It is designed to receive signals from the staff activation device in the event of an attack.Key FeaturesInstallation Flush or surface mount in standard single gang electrical back boxSize 80 x 80 x 20 mm GBP 151.48 1
Nursecall Intercall G822 Addressable Call Reset Nursecall Intercall G822 Addressable Call ResetThe G822 addressable call point can generate six levels of call. There is also a call follower sounder which sounds when the call point is in staff present mode to inform staff of another call on the system. The extended input terminals will accept any closing contact input including radio triggers pressure mats and a host of other triggering devices.Key FeaturesInstallation Flush or surface mount in standard single gang electrical back boxSize 85 x 85 x 20 mm GBP 103.27 1
Nursecall Intercall 924 Access Point Nursecall Intercall 924 Access PointThe Access Point is a simple cost effective wireless ID security system. Using Radio Frequency Identification technology RFID the Access Control Point allows hospitals and care facilities to control access to sensitive and restricted areas.The Access Control Point controls the door locking mechanism at a variety of entry points and raises an alarm on the call system should there be unauthorised access. Vulnerable patients and their family can rest assured knowing they are safe from unauthorised visitors 24 hours a day 7 days a week.ID cards can be programmed using individual staff identity information. Cards can be printed with your facilitys logo and brand colour palette making them instantly recognisable as belonging to your facility.With multiple programmable access levels entry to sensitive areas can be managed staff movement monitored and recorded on our data log database system - allowing for full accountability.The Access Control Point is installed on the simple Intercall Bus network and individually programmable via the Intercall Device Programming Software.Key FeaturesNetwork Intercall busInstallation Surface mount enclosure to UKEU fixing GBP 134.95 1
Nursecall Intercall 600700 Series IP Power Supply Controller Nursecall Intercall 600700 Series IP Power Supply ControllerThe L7700 has the capacity to power an entire Intercall system with provision in the enclosure to accommodate a 12V battery for system backup requirements.The unit features integrated IEEE 802.3 Ethernet controller with embedded web server permitting system configuration datalog access and remote monitoring using a standard web browser. Security is maintained as web access to the setup and configuration screens are password protected. The Ethernet port may be used to connect IP controllers together provide an interface to other Intercall IP devices and for connection to third party products such as IP DECT phones and message paging.The unit features onboard calendar clock and Secure Data flash disk drive which records all system activity and configuration settings. DayNight alarm settings may be automatically switched by the on-board clock without the need for a manual switch. Programmable volt free contact inputs and a volt free contact output are provided together with an RS232 interface which can be configured for many baud rate and data formats.An Audio Gateway VOIP expansion card may be used in addition to allow the audio voice channel conversations to be recorded andor integrated with other IP devices. The integral float charger supports a single 12Volt 12AH battery and the AC DC Battery and Earth continuity are monitored continuously.Please Note The L7700 is not compatible with the L737 booster power supply.Key FeaturesMain supply input 90-240VACRequired battery 12V 612AHOutput terminals 3 terminals providedEthernet IEEE 802.3 Compatible 10Base-T InterfaceInputOutputsInput 1Input 2Relay Out 1ARelay Out 1BSerial RS232 OutputOnboard Fuse 5Amp 20mm Quick BlowInstallation Self-contained surface mount caseSize 370mm x 260mm x 110mmWeight 4.5 Kg GBP 860.63 1