Nursecall Intercall LCU Light Control Unit Nursecall Intercall LCU Light Control UnitThe LCU is a Light Control Unit. GBP 61.97 1
Nursecall Intercall L628 600700 Series LCD Display Unit Nursecall Intercall L628 600700 Series LCD Display UnitA display unit is required in every location where calls are to be shown and the alarm is to sound. It features LCD display with backlight multi-level adjustable alarm daynight volume control priority alarm tone for specific call locations configuration menus and an output which can be connected to trigger external equipment.All displays work identically but can be configured on site to operate independently. The L628 Large Style Display Unit illustrated operates in the same way as the L618 Standard Display Unit but features 30 larger LCD mounted in Intercall style housing. GBP 289.18 1
Nursecall Intercall L762 700 Series Call Display Unit with Integral Display Nursecall Intercall L762 700 Series Call Display Unit with Integral DisplayThe L762 is a combined speech call point and a built-in display. When staff are present it will display other calls on the system in full alphanumeric text so staff can accept calls and speak to other callers elsewhere on the system without having to leave the residents room. This feature is especially important in larger homes or at night time when the home is running on reduced staffing levels.The L762 CallDisplay Unit provides all the combined features of the L752 Audio call point and L758 Audio LCD display. It features seven levels of call hands free two way intercom integral infra-red receiver integral LCD display audio page facility audible call re-assurance re-assurance LED and another call sounder. The trigger socket will accept pear leads pressure mats portable radio triggers and a host of other triggering devices. The unit flush mounts into a standard double gang backbox or may be surface mounted using the Intercall BB1. All X1 to X5 remote trigger inputs feature a secondary description facility where details for the remote device may be programmed. For example En-Suite or Ceiling Pull Switch may be allocated to these inputs. GBP 268.51 1
Nursecall Intercall L634 600700 Series Network Input Output Unit Nursecall Intercall L634 600700 Series Network Input Output UnitThe L634 is used to interface an external device to the Intercall system network. The unit features three input triggers two non-latching and one remote reset and two outputs Re-assurance LED open collector which can be used to trigger external equipment for normal or emergency calls. Typical applications include telephone ring detectors contacts from fire alarm or other control panels or input from remote contacts etc. GBP 123.94 1
Nursecall Intercall L758 700 Series LCD Display Unit with Intercom Facility Nursecall Intercall L758 700 Series LCD DIsplay Unit with Intercol FacilityPositioned in areas where calls need to be shown and heard. Firstly and foremost it provides a two-way Speech communication with the caller. A secondary feature allows an audio page facility to all other displays and to other speech call point with staff members present. Following activation of a call point the display provides a description of the call type the location.Different tones identify the varying call types. A useful feature is the Find Staff button which allows the user to locate other staff member easily. Sound levels Day and night are adjustable individually and the menu offers multiple setups to the home including zoning of areas. GBP 440.64 1
Nursecall Intercall HD2 Handset Call and Bed Light Control Buttons Nursecall Intercall HD2 Handset Call and Bed Light Control ButtonsHandset Call and Bed Light control buttons combined within one unit to be used with Intercall LCU light control unit. GBP 67.48 1
Nursecall Intercall L733 600700 Series Door Monitoring amp Access Control Point Nursecall Intercall L733 600700 Series Door Monitoring Access Control PointIf you need to protect fire doors entrance exit doors or other sensitive areas the L733 is the ideal solution. The unit is controlled with a key token which performs all functions when brought near the token detection area on the front panel. The unit also features an integral 20-second exit timer with audible bleep and mode jumper to prevent sensitive or dangerous exit doors being permanently left open.The unit features standard call and emergency call generation integral 20 second exit timer with audible bleep and mode jumper to prevent sensitive or dangerous exit doors being permanently left open. In mode I II the unit automatically re-arms when the door is closed. In mode III the unit must be manually re-armed. GBP 117.05 1
Nursecall Intercall AIRX8 External Addressable IR Receiver Nursecall Intercall AIRX8 External Addressable IR ReceiverThe Addressable Infra Red External Receivers use infrared technology to detect incidents in outside locations. The reliable design of the unit means that it is immune to interference from sunlight.This component of the personal alarm system is housed within an IP65 rated weatherproof case designed specifically to provide coverage for external areas such as courtyards patios and gardens.All cable entry points are made through knock-outs at the bottom and back of the unit where a conduit union can be fitted to ensure that no moisture ingresses into the electronics.The design of the AIRX8 along with the sun filter means that it is immune to interference from sunlight. The unit should be mounted high on an external wall to prevent tampering. In the event of tampering with the AIRX8 the unit has a tamper switch built into it which will alert the display units.As with all the Guardian addressable IR receivers the unit is addressable. It has a removable jumper to disable the two colour reassurance LED which when active indicates that the unit is operational.Key FeaturesProvides coverage for external areasDesigned to prevent interference from sunlightFully addressable GBP 426.88 1
Nursecall Intercall L722 600700 Series Non-Audio Call Point with IR Receiver Nursecall Intercall L722 600700 Series Non-Audio Call Point with IR ReceiverThe L722 is specifically developed for bathrooms toilets and other areas where the intercom facility is not required. This Non-Audio Call Point incorporates 3 levels of call Standard Assistance and Emergency. The unit also features an infra-red receiver and reassurance LED. The unit will accept inputs from a wide range of triggering devices including pear leads air switches pressure mats etc.Key FeaturesThe unit may be flush or surface-mounted using standard electrical back boxes GBP 99.14 1
Nursecall Intercall PM2 Heavy Duty Anti-Bacterial Pressure Mat Nursecall Intercall PM2 Heavy Duty Anti-Bacterial Pressure MatThe large anti-bacterial pressure mat is placed on the floor and simply connects to your nursecall system activating a standard call when a resident steps on it. The unit comes with a four metre lead and plugs onto the call unit jack socket.Key FeaturesDimensions 610mm x 910mmMat is foldable GBP 136.32 1
Nursecall Intercall LBAT 12V 2.1Ah Battery Nursecall Intercall LBAT 12V 2.1Ah BatteryThe TRF4 is a RF neck pendant designed for use with the L617 L717 and L737 power supply unit. GBP 34.43 1
Nursecall Intercall L737 500600700 Series Universal Booster Power Supply Nursecall Intercall L737 500600700 Series Universal Booster Power SupplyThe Booster Power Supply unit is designed to increase the permitted number of units and quantity of cable that can be used on any one system. Only one master power supply may be connected on any one system but several booster units may be connected as required.Key FeaturesBooster power supply unit to be used in conjunction with 617 and 717 power supply units GBP 895.06 1
Nursecall Intercall L748 Corridor LED Display with Illuminated 100mm Characters Nursecall Intercall L748 Corridor LED Display with Illuminated 100mm CharactersThe L748 Corridor LED Display is ideal for where calls need to be easily and clearly seen by staff on the move. It may be used in several applications including hospitals doctors surgeries and larger nursing homes. Call information is very clearly displayed on the illuminated 16 character display. The integral alarm is adjustable for day and night volumes the display may be configured to show a standing message or appear off when no calls are active on the system. The unit is compatible with the INTERCALL 700 protocol only and shows the same text as the LCD display units.The unit can either operate as the only type of display on the system or can be used in conjunction with the standard LCD units. Operation of the unit is similar to the standard LCD units with all calls numbered in queue order. Emergency and Attack calls are flashed on the display to show the higher priority while normal assistance and priority calls are stored in memory but not displayed until the higher priority calls are dealt with. There are no user controls on the unit however the display menus controls are available and the unit has a unique display menu structure for configuration. These menus are configured using the two buttons in a similar manor to the standard display.Key FeaturesThe unit can either operate as the only type of display on the system or can be used in conjunction with the standard LCD units GBP 998.33 1
Nursecall Intercall L717 600700 Series Budget Power Supply Nursecall Intercall L717 600700 Series Budget Power SupplyThe L717 is the main power and control unit for the Intercall 600 system. It connects to the mains supply and incorporates full battery back up to safeguard the system in the event of a mains supply failure. It also stores the text programming information and can be used to configure the system by simply connecting a laptop computer. An alternative power supply unit is required for larger installations and is designed to increase the permitted number of units and quantity of cable allowed on one system. GBP 619.66 1
Nursecall Intercall RB1 Relay Board Nursecall Intercall RB1 Relay BoardThe RB1 Relay board converts the OC output from the LCD Displays L628L758 and L746 Over door Light into Normally Open and Normally Closed contact sets. The unit may also be configured by the factory to provide time delays for some access door applications. It may also be used to trigger a call point from a external voltage such as door bells etc. The unit is fitted with a T 12v output which may be used to drive low current devices from the network. GBP 61.97 1
Nursecall Intercall M1 Door Contact Reed Switch Nursecall Intercall Door Contact Reed SwitchNormally open door contact for use with Intercall door monitoring points L733 and L744.Key FeaturesInstalled in conjunction with door monitoring unit or call point and isolation switchesActivates paired call point when door is opened GBP 12.49 1
Nursecall Intercall L746S 600700 Series Overdoor Light with Sounder Nursecall Intercall L746S 600700 Series Overdoor Light with SounderOver door lights are an optional item normally positioned above the door in a corridor to indicate the status of the call points within the room. The L746 can be used to monitor several call point addresses and are ideal for end of corridor indication. The L746S Unit is fitted with an integral sounder.It is fitted with Red and Green LEDs which mimic the re-assurance indicator on the call points. The unit is addressable and requires no separate connection to the call points. It is set to the address range of the call points it is required to indicate. There are with two banks of DIL switches one set to the lowest call point address and another set to the highest address. GBP 79.87 1
Nursecall Intercall DISP1 LCD Alphanumeric Display Nursecall Intercall DISP1 LCD Alphanumeric DisplayThe DISP1 LCD Corridor Display Unit is the device used to sound the alarm and identify the location of each incident along with the level of assistance required. The display can also show the identity of the staff member calling for assistance.The DISP1 features a two line 16 character back lit LCD display and a multi level adjustable alarm. The unit features different tones for different levels of call as well as having the capability of sounding a different tone for selected call points doors drugs cupboards telephone etc. The DISP1 can also be setup to display specific call points zoning if required.All DISP1 Display Units are identical but each can be configured to operate independently or as a slave display to a master unit.Key FeaturesSize 163 x 115 x 35 mmInstallation Flush mount in standard double gang electrical back box. Surface mount using Intercall BB1 back box GBP 392.45 1
Nursecall Intercall 700 Series Dementia Controller Nursecall Intercall 700 Series Dementia ControllerThe Intercall Dementia Controller is designed as a non-intrusive system to monitor resident rooms. The call system detects when a resident is out of bed and activates room lighting helping to reduce the risk of a fall. Staff are alerted through the Intercall nurse call system in the event of abnormal behaviour.By controlling the lighting in the bedroom and ensuite WC areas the unit helps guide a confused resident to the bathroom and back to bed without the need for staff intervention. In the event that the residents movements do not represent normal behaviour an alarm is automatically raised and staff are alerted through the nurse call system. In addition the unit can be congured to monitor bedroom and patio doors to alert staff immediately should the resident leave the bedroom.Key FeaturesSimple non-intrusive monitoring without restriction to residentEasy to use two button operations with clear LCD screenControls bed WC lights to guide confused residentResident activity recorded using the IP Power SupplyFully compatible with Intercall 600700 Nursecall SystemOn site configurable options for specific client requirements GBP 330.48 1
Nursecall Intercall SCP Slave Call Point Nursecall Intercall SCP Slave Call PointDesigned for use in one room or ward where each individual bed doesnt need a separate identity on the call system. The unit features a call button pear lead jack socket and re-assurance indicator. Units must be connected to a standard call point to generate the call identity and to provide the reset. Slave call points can only generate a standard call from either the call button or pear lead socket. GBP 42.68 1
Nursecall Intercall L753 700 Series Call Point with IR Receiver amp Intercom Facility D Gang Size Nursecall Intercall L753 700 Series Call Point with IR Receiver Intercom Facility D Gang SizeThe L753 is an Audio call point which gives the facility of hands free speech. It incorporates 3 levels of call i.e. Standard Assistance and Emergency. Other features include an infra-red receiver reassurance LED and call follower sounder. It will also accept a host of triggering devices including pear leads air switches and pressure mats etc.Key FeaturesThe unit may be flush or surface-mounted using the Intercall BB1 Back box. GBP 185.89 1
Nursecall Intercall L714 600700 Series Remote Sounder and Relay Output Board Nursecall Intercall L714 600700 Series Remote Sounder and Relay Output BoardIf you need an audible alarm to attract attention but dont need an indication of the call location the L714 is the simple solution. The sounder is similar in operation to a display unit with a multi-level alarm but has limited zoning facilities. Any assistance or emergency call on the system will over-ride the standard call tone. A built-in relay provides normally open and normally closed dry contacts which can be used to trigger auxiliary devices. GBP 136.32 1
Nursecall Intercall LimKit Configuration Software Kit includes Connection Leads Nursecall Intercall LimKit Configuration Software Kit includes Connection Leads for L717 L747 TIR4The LIMK Limprog USB programming kit is used to program the Intercall nurse call systems. The Intercall power supply no longer contains pre-set addresses such as Bedroom 1 or Lounge. To achieve custom text in this way it is necessary to program this information into the power supply using the Limprog software.Simply install the software to your computer and connect it to the Intercall power supply unit with the provided connection cable. Using the Limprog software you can then choose to assign custom text to each address on the system by selecting the address number and typing your chosen text. Once this address list has been completed and uploaded to the power supply unit the custom text will now be shown on the display panels whenever a call is made.The software is also used to program Intercall TIR4 neck pendants worn by clients who need to make calls remotely from their bed or chair as well as the Guardian STC staff attack triggers. Programming the triggers and pendants allows you to set what call type is made when the device is activated e.g. standard call emergency call or even configuring the trigger to reset the system. GBP 468.18 1
Nursecall Intercall L7322 Stainless Steel Addressable Call Button Nursecall Intercall L7322 Stainless Steel Addressable Call ButtonThe Intercall L7322 is an addressable fixed point push button unit for applications where a fixed point call button is required for anyone to use. The device connects to the network like any other network device and has its own unique address to give a location when activated.Key FeaturesStainless steel constructionFeatures a shrouded push button to prevent accidental activationMultiple alert levelsAssigned its own text address to display on the systemBuilt in reassurance LED giving the user an immediate visual indication that help is on the wayFeatures an external auxiliary input GBP 151.48 1
Nursecall Ceiling Pull Switch with Wipe Clean Cord amp Re-Assurance Light Nursecall Ceiling Pull Switch with Wipe Clean Cord Re-Assurance LightSpecifically developed to give alarms from bathrooms toilets and en-suites. The unit is ceiling mounted and features a floor length cord terminated with two easy to use to pull handles. It also incorporates a reassurance indicator which flash to confirm a call has been generated.Key FeaturesWipe clean plastic cord helps to control infectionTwo easy to grip handles providedRe-assurance LED confirms the call has gone throughCan be configured as normally open or normally closed to suit the systemCompatible with Intercall 600 Intercall 700 Encompass Nurse Call and SAS Nurse Call GBP 16.52 1