58 results (0,13891 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

Notifier S300PTU Programming Test Unit for PhD Detectors

Notifier Honeywell SCU System Communication Unit 583381.31

Notifier Honeywell PSU 24V-2 Emergency Power Supply Unit for VAPA System 581722

Notifier Honeywell PSU 24V-4 Emergency Power Supply Unit for VAPA System 581723

Notifier FAAST LT200 Smoke Aspirating Unit Single Channel NFXI-ASD11-HS-EB

Notifier FAAST LT200 Smoke Aspirating Unit Single Channel NFXI-ASD11-HS-EB

Notifier FAAST LT200 Smoke Aspirating Unit Single Channel NFXI-ASD11-HS-EBThe FAAST LT-200 Aspirating Smoke Detector is designed with the installer and end user in mind. It is a single channel loop which connects to the FAAST LT aspiration unit. It comes with 1 HSS detector and base and has a built in filter.It serves the wide variety of Class C applications where maintenance is difficult other smoke detection methods are inappropriate or prone to fail due to harsh environments or areas where aesthetics matters. FAAST LT-200 combines proven aspiration detection technologies to deliver reliable smoke detection and efficient installation and maintenance.The device comprises innovative and intelligent internal design features designed to protect vulnerable components. These include a high sensitivity LED detection chamber featuring a high-power output IR LED and high gain IR receiver amplifier along with ultrasonic flow sensors. The device is fast to install and easy to commission thanks to PIPE IQ LT pipe design and configuration software which is included as standard.FAAST LT-200 loop-based devices are available as single channel and dual channel devices offering flexibility for different detection strategies. A range of customisable settings are geared towards maximising device performance and meeting different application needs.Loop capability allows standard device integration maintenance and support consistent with other Notifier Opal devices.Key FeaturesRequires a 24V Power SupplyIncluded is an earth bar product code F-LT-EBHigh sensitivity LED Detection Chamber specially designed to cover Class C. Includes a high-power output IR LED and high gain IR receiver amplifierSingle Dual channel versions with independent channels including fan sensor and flow monitoringSupports CLIP and Opal protocolProvides pre-alarm functionality for graduated alarm thresholdsUltrasonic airflow sensing with expanded monitoring rangeA single device covers up to 2000m2Pipe-IQ software provides intuitive system layout and configuration all in one packageMultiple event logging up to 2244 eventsUser friendly air flow pendulum graph for verification of pipe network functionalityEasily replaceable and reusable filter without affecting the rest of the deviceProtected electronics from air flow and accidental damage during installation or maintenanceDesigned for efficient wiring and installation cable gland holes easy access to the wiring area and no special tools requiredEasy access to parts requiring routine maintenance filters and sensors.IP65 enclosure

GBP 2254.32
1

Notifier Honeywell ABT-ISLE Audio RS485 Interface

Notifier M5A-RP02FG-N026-01 Addressable Call Point cw Isolator

Notifier M5A-RP02FG-N026-01 Addressable Call Point cw Isolator

Notifier M5A-RP02FG-N026-01 Addressable Call Point cw IsolatorThis Notifier Manual Call Point Break Glass Unit M5A-RP02FG-N026-01 is specifically designed to be used on Notifier Protocol Fire Alarm Control Panels. The unit is designed to give a manual signal to the Notifier Fire Alarm Control panel which will operate the fire alarm system.This unit features an integral loop isolator built into the device.These units are based on the industry standard KAC manual call point. They have been designed specifically to give installation efficiency flexibility and compliance with the latest standards.The Notifier Manal Call Point Break Glass M5A-RP02FG-N026-01 features an Integral LED. This LED will illuminate once the break glass unit has been operated. This feature allows easy identification as to which Notifier Manual Call Point Break Glass has been operated.The Notifier Manual Call Point Break Glass Unit features a unique plug and play concept that is designed specifically to reduce installation time by using a terminal block which can be wired during the initial installation cabling with a link to provide continuity for testing. During the commissioning phase the links are removed and the terminal block is simply inserted into the connector at the back of the unit. No re-termination is required.This Notifier Manual Call Point uses one of 99 possible addresses which is simply dialled in using the two rotary decade switches on the rear of the unit.A specialist test key may be inserted into the bottom of the unit to lower the glass and release the micro-switch and thus a full functional test is achieved.It is supplied as a flush mounting unit. It requires a single gang back box for surface mounting not included.Key FeaturesGlass includedRequires PS031W for surface-mounting terminal tray TB011 and single gang backbox for semi-flushing mountingUnique plug and play installation conceptFlush Mounted Call Point requires backbox for Surface Mounting Please see related products belowResettable plastic element option available not includedNotifier Analogue Addressable Protocol CommunicationsFully compliant with EN54 Part 11Backward CompatibleEnhanced AestheticsIntegral LEDIntegral Isolator

GBP 61.66
1