Morley Red Control Key for Horizon Panel Pack of 10 Morley Red Control Key for Horizon Panel Pack of 10Spare red controls key Pack of 10 for Horizon Fire Panel GBP 93.64 1
Morley EVCS-TAP Emergency Assist Alarm Stand Alone Kit with PSU Morley EVCS-TAP Emergency Assist Alarm Stand Alone Kit with PSUThis is a simple two wire system that has been specifically designed to meet the needs of disabled service users and conforms to all the relevant requirements. The use of combined high output blue LED indication and buzzer ensures a response to the call. The Emergency Assist Alarm Stand Alone Kit comprises of all the components needed to install a fully compliant system with additional parts available separately.Key FeaturesComplies with regulations recommendationsDual loop pull cordHigh contrast labelsBlue indicationQuick and simple installation with limited cabling requirementsHigh contrast printing for increased visibilityTactile braille signage to assist partially sighted people to easily operate the cancel plate GBP 98.66 1
Morley Network 16 Digital Master Panel EVCS-MPX-16 Morley Network 16 Digital Master Panel EVCS-MPX-16Network 16 is designed to ensure simplicity of future expansion a maximum of 16 outstations of various types can be controlled from one master panel. Loop wiring ensures the system is fault tolerant through the use of short circuit isolators and continuous fault monitoring ensures high availability.The system uses digital audio transmission to maintain audio quality and intelligibility when it matters most. The simplicity of operation ease of cabling and competitive pricing make the system suitable for a wide range of applications.In combination with our range of soft addressed digital outstations this stand-alone system reduces the labour and materials cost along with the potential for wiring errors associated with traditional spur systems. Extensive time stamped logs and records are stored internally on the SD cardKey FeaturesUp to 16 digital outstations per panel4 core loop configurationSoft addressing of outstationsSD card integrationStainless steel flush mounting optionEase of programmingLarge graphic user interfacePIN protected user levelsSimple to operateEnd user graphical interfaceFull range of compatible outstationsEasy to design systemSimple commissioningEasily maintained and backed upSecure access for standard usersQuick and simple identification of outstation in use GBP 2037.80 1
Morley ZX1Se Intelligent Single Loop Fire Alarm Control Panel Multi-Protocol Morley ZX1Se Intelligent Addressable Single Loop Fire Alarm Control Panel Multi-ProtocolOrder loop cards for the ZXSe panel separately. Please scroll down to see options below.The ZXSe range of analogue addressable fire alarm control panels have been designed and constructed around proven and reliable microprocessor technology. This simple approach has produced a modular scalable fire alarm platform suitable for protecting all types of premises. Supporting a total of five industry leading protocols Apollo Hochiki ESP Nittan Morley-IAS and System Sensor allows fire detection devices to be independently selected based on performance or aesthetic appeal.The ZXSe range of intelligent fire alarm control panels has been designed to assist with the normal operation of a fire detection system. Standard weekly testing is available through a simple menu structure allowing selection of the zones to be tested either with or without activation of the output relays or sounders.Additionally the status of individual devices can be analysed to determine whether cleaning or replacement is required. As the installation grows the ZXSe panel can expand with the building or site by adding additional devices loop cards printers or repeater panels. Additionally further ZXSe panels can be networked together allowing an even bigger system to be created.Key FeaturesAll major device manufacturers devices supportedOptional local or remote printersWalk test facilityProvide up to 72hr stand-by subject to verificationSupporting a total of five industry leading protocols Apollo Hochiki ESP Nittan Morley-IAS and System SensorSimple robust design to EN54 Parts 2 4Facility to print history and event logsReport Control System - For multiple building sites where information is presented at the local and master panels only99 panel network allows systems in excess of 60000 devices to be managed GBP 1133.96 1
Morley ZX2Se Intelligent 1-2 Loop Fire Alarm Control Panel Multi-Protocol Morley ZX2Se Intelligent Addressable 1-2 Loop Fire Alarm Control Panel Multi-ProtocolOrder loop cards for the ZX2Se panel separately. Please scroll down to see options below.The ZXSe range of analogue addressable fire alarm control panels have been designed and constructed around proven and reliable microprocessor technology. This simple approach has produced a modular scalable fire alarm platform suitable for protecting all types of premises. Supporting a total of five industry leading protocols Apollo Hochiki ESP Nittan Morley-IAS and System Sensor allows fire detection devices to be independently selected based on performance or aesthetic appeal.The ZXSe range of intelligent fire alarm control panels has been designed to assist with the normal operation of a fire detection system. Standard weekly testing is available through a simple menu structure allowing selection of the zones to be tested either with or without activation of the output relays or sounders.Additionally the status of individual devices can be analysed to determine whether cleaning or replacement is required. As the installation grows the ZXSe panel can expand with the building or site by adding additional devices loop cards printers or repeater panels. Additionally further ZXSe panels can be networked together allowing an even bigger system to be created.Key FeaturesAll major device manufacturers devices supportedOptional local or remote printersWalk test facilityProvide up to 72hr stand-by subject to verificationSupporting a total of five industry leading protocols Apollo Hochiki ESP Nittan Morley-IAS and System SensorSimple robust design to EN54 Parts 2 4Facility to print history and event logsReport Control System - For multiple building sites where information is presented at the local and master panels only99 panel network allows systems in excess of 60000 devices to be managed GBP 1516.76 1
Morley ZX5Se Intelligent 1-5 Loop Fire Alarm Control Panel Multi-Protocol Morley ZX5Se Intelligent Addressable 1-5 Loop Fire Alarm Control Panel Multi-ProtocolOrder loop cards for the ZX5Se panel separately. Please scroll down to see options below.The ZX5Se range of analogue addressable fire alarm control panels have been designed and constructed around proven and reliable microprocessor technology. This simple approach has produced a modular scalable fire alarm platform suitable for protecting all types of premises. Supporting a total of five industry leading protocols Apollo Hochiki ESP Nittan Morley-IAS and System Sensor allows fire detection devices to be independently selected based on performance or aesthetic appeal.The ZXSe range of intelligent fire alarm control panels has been designed to assist with the normal operation of a fire detection system. Standard weekly testing is available through a simple menu structure allowing selection of the zones to be tested either with or without activation of the output relays or sounders.Additionally the status of individual devices can be analysed to determine whether cleaning or replacement is required. As the installation grows the ZXSe panel can expand with the building or site by adding additional devices loop cards printers or repeater panels. Additionally further ZXSe panels can be networked together allowing an even bigger system to be created.Key FeaturesAll major device manufacturers devices supportedOptional local or remote printersWalk test facilityProvide up to 72hr stand-by subject to verificationSupporting a total of five industry leading protocols Apollo Hochiki ESP Nittan Morley-IAS and System SensorSimple robust design to EN54 Parts 2 4Facility to print history and event logsReport Control System - For multiple building sites where information is presented at the local and master panels only99 panel network allows systems in excess of 60000 devices to be managed GBP 2500.63 1
Morley Printer Roll amp Printer Ribbon for ZX Panel Internal Printers Morley Printer Roll Printer Ribbon for ZX Panel Internal PrintersSingle Printer paper roll and printer ribbon for ZXeZXSe internal printer. GBP 54.40 1
Morley DXc2 2 Loop Addressable Control Panel Multi-Protocol Morley DXc2 Addressable 2 Loop Fire Alarm Control Panel Multi-ProtocolThe DX Connexion is an enhancement of the Morley-IAS Dimension panel range connecting the traditional Morley-IAS qualities of reliability flexibility and value with advanced features and intuitive functionality.The multi-protocol DX Connexion range of fire alarm control panels has been developed to be the most time efficient fire panel on the market to install. DXc Control panels are supplied without zone LEDs. In order to connect panels together to create a network a DXc Network card and DXc Control panels are supplied without zone LEDs.Key FeaturesTwo Loop Control Panel 230Vac 2 sounder circuits.Supporting industry leading protocols Apollo Hochiki ESP and System SensorDims 391.5 x 390 x 147 H x W x DNetwork up to 16 loops 16x1 loop panels 8x2 loop panels 4x4 loop panels or any mix up to max 16 loopsTrue peer-to-peer and fault tolerant network for high system reliabilityBS5839 part 1 compliant networkDisable all relaysEasy 5 key-press set-upsLarge blue LCD displaySupports USB uploaddownloadAlpha-numeric style keypad and navigation keysOption to upload a company logo160 zone compact mimic supportPanel buzzer mute in engineering modeUp to 72-hour standby GBP 1308.16 1
Morley ZX5Se Addressable 1-5 Loop Stainless Steel Control Panel Multi-Protocol Morley ZX5Se Addressable 1-5 Loop Stainless Steel Control Panel Multi-ProtocolThe ZX5Se range of analogue addressable fire alarm control panels have been designed and constructed around proven and reliable microprocessor technology. This simple approach has produced a modular scalable fire alarm platform suitable for protecting all types of premises. Supporting a total of five industry leading protocols Apollo Hochiki ESP Nittan Morley-IAS and System Sensor allows fire detection devices to be independently selected based on performance or aesthetic appeal.The ZXSe range of intelligent fire alarm control panels has been designed to assist with the normal operation of a fire detection system. Standard weekly testing is available through a simple menu structure allowing selection of the zones to be tested either with or without activation of the output relays or sounders.Additionally the status of individual devices can be analysed to determine whether cleaning or replacement is required. As the installation grows the ZXSe panel can expand with the building or site by adding additional devices loop cards printers or repeater panels. Additionally further ZXSe panels can be networked together allowing an even bigger system to be created.Key FeaturesAll major device manufacturers devices supportedOptional local or remote printersWalk test facilityProvide up to 72hr stand-by subject to verificationSupporting a total of five industry leading protocols Apollo Hochiki ESP Nittan Morley-IAS and System SensorSimple robust design to EN54 Parts 2 4Facility to print history and event logsReport Control System - For multiple building sites where information is presented at the local and master panels only99 panel network allows systems in excess of 60000 devices to be managed GBP 3897.60 1
Morley 721-001-200 ZX5Se Addressable 1-5 Loop Control Panel 200 Zone LEDs Multi-Protocol Morley 721-001-200 ZX5Se Addressable 1-5 Loop Control Panel 200 Zone LEDs Multi-ProtocolOrder loop cards for the ZX5Se panel separately. Please scroll down to see options below.The ZX5Se range of analogue addressable fire alarm control panels have been designed and constructed around proven and reliable microprocessor technology. This simple approach has produced a modular scalable fire alarm platform suitable for protecting all types of premises. Supporting a total of five industry leading protocols Apollo Hochiki ESP Nittan Morley-IAS and System Sensor allows fire detection devices to be independently selected based on performance or aesthetic appeal.The ZXSe range of intelligent fire alarm control panels has been designed to assist with the normal operation of a fire detection system. Standard weekly testing is available through a simple menu structure allowing selection of the zones to be tested either with or without activation of the output relays or sounders.Additionally the status of individual devices can be analysed to determine whether cleaning or replacement is required. As the installation grows the ZXSe panel can expand with the building or site by adding additional devices loop cards printers or repeater panels. Additionally further ZXSe panels can be networked together allowing an even bigger system to be created.Key FeaturesAll major device manufacturers devices supportedOptional local or remote printersWalk test facilityProvide up to 72hr stand-by subject to verificationSupporting a total of five industry leading protocols Apollo Hochiki ESP Nittan Morley-IAS and System SensorSimple robust design to EN54 Parts 2 4Facility to print history and event logsReport Control System - For multiple building sites where information is presented at the local and master panels only99 panel network allows systems in excess of 60000 devices to be managed GBP 4959.26 1
Morley 721-001-140 ZX5Se Addressable 1-5 Loop Control Panel 140 Zone LEDs Multi-Protocol Morley 721-001-140 ZX5Se Addressable 1-5 Loop Control Panel 140 Zone LEDs Multi-ProtocolOrder loop cards for the ZX5Se panel separately. Please scroll down to see options below.The ZX5Se range of analogue addressable fire alarm control panels have been designed and constructed around proven and reliable microprocessor technology. This simple approach has produced a modular scalable fire alarm platform suitable for protecting all types of premises. Supporting a total of five industry leading protocols Apollo Hochiki ESP Nittan Morley-IAS and System Sensor allows fire detection devices to be independently selected based on performance or aesthetic appeal.The ZXSe range of intelligent fire alarm control panels has been designed to assist with the normal operation of a fire detection system. Standard weekly testing is available through a simple menu structure allowing selection of the zones to be tested either with or without activation of the output relays or sounders.Additionally the status of individual devices can be analysed to determine whether cleaning or replacement is required. As the installation grows the ZXSe panel can expand with the building or site by adding additional devices loop cards printers or repeater panels. Additionally further ZXSe panels can be networked together allowing an even bigger system to be created.Key FeaturesAll major device manufacturers devices supportedOptional local or remote printersWalk test facilityProvide up to 72hr stand-by subject to verificationSupporting a total of five industry leading protocols Apollo Hochiki ESP Nittan Morley-IAS and System SensorSimple robust design to EN54 Parts 2 4Facility to print history and event logsReport Control System - For multiple building sites where information is presented at the local and master panels only99 panel network allows systems in excess of 60000 devices to be managed GBP 4290.05 1
Morley DXc Control Panel Key Switch Kit Morley DXc Control Panel Key Switch KitDXc key switch kit Control panels can be fitted with an optional key switch kit fitted by removing the existing label and replacing with a new label supplied with the kit. The flying lead fitted with a plug pushes on to the two pins situated at the bottom of the main display PCB. GBP 99.83 1
Morley DXc1 Addressable Single Loop Fire Alarm Control Panel Multi-Protocol Morley DXc1 Addressable Single Loop Fire Alarm Control Panel Multi-ProtocolThe DX Connexion is an enhancement of the Morley-IAS Dimension panel range connecting the traditional Morley-IAS qualities of reliability flexibility and value with advanced features and intuitive functionality.The multi-protocol DX Connexion range of fire alarm control panels has been developed to be the most time efficient fire panel on the market to install. DXc Control panels are supplied without zone LEDs. In order to connect panels together to create a network a DXc Network card and DXc Control panels are supplied without zone LEDs.Key FeaturesSingle Loop Control Panel 230Vac 2 sounder circuits.Supporting industry leading protocols Apollo Hochiki ESP and System SensorDims 260 x 390 x 147mm H x W x DNetwork up to 16 loops 16x1 loop panels 8x2 loop panels 4x4 loop panels or any mix up to max 16 loopsTrue peer-to-peer and fault tolerant network for high system reliabilityBS5839 part 1 compliant networkDisable all relaysEasy 5 key-press set-upsLarge blue LCD displaySupports USB uploaddownloadAlpha-numeric style keypad and navigation keysOption to upload a company logo160 zone compact mimic supportPanel buzzer mute in engineering modeUp to 72-hour standby GBP 817.25 1
Morley DXc4 Addressable 4 Loop Fire Alarm Control Panel Multi-Protocol Morley DXc4 Addressable 4 Loop Fire Alarm Control Panel Multi-ProtocolThe DX Connexion is an enhancement of the Morley-IAS Dimension panel range connecting the traditional Morley-IAS qualities of reliability flexibility and value with advanced features and intuitive functionality.The multi-protocol DX Connexion range of fire alarm control panels has been developed to be the most time efficient fire panel on the market to install. DXc Control panels are supplied without zone LEDs. In order to connect panels together to create a network a DXc Network card and DXc Control panels are supplied without zone LEDs.Key FeaturesFour Loop Control Panel 230Vac 2 sounder circuits.Supporting industry leading protocols Apollo Hochiki ESP and System SensorDims 391.5 x 390 x 147 H x W x DNetwork up to 16 loops 16x1 loop panels 8x2 loop panels 4x4 loop panels or any mix up to max 16 loopsTrue peer-to-peer and fault tolerant network for high system reliabilityBS5839 part 1 compliant networkDisable all relaysEasy 5 key-press set-upsLarge blue LCD displaySupports USB uploaddownloadAlpha-numeric style keypad and navigation keysOption to upload a company logo160 zone compact mimic supportPanel buzzer mute in engineering modeUp to 72-hour standby GBP 2124.71 1
Morley IAS Active Repeater Panel for DXc amp ZXSe Panels Morley IAS Active Repeater Panel for DXc ZXSe PanelsThe Morley-IAS repeaters are compact remote-control units for Morley-IAS intelligent multi-protocol fire alarm control panels. These units along with other IO peripheral devices and the external printer further enhance the flexibility and functionality of our fire alarm control panel range.The repeaters provide an extension to the operation of the fire alarm control panel. There are two types available - passive with indications only and no controls or active with both controls and indicators. Both display the operational state of the control panel using the 80-character LCD display and the 7 LED status indicators.In addition to the general status indicators the Active repeater is fitted with key operated Access Enable switch for the control functions. Individual buttons are provided for System Reset Mute Accept Sound Alarms SilenceRe-sound Alarms and Self-test. Thus enabling control functions to be duplicated in strategic locations around the installation.The Active repeater includes an integral self-test sequence guiding the operator through a pre-set sequence to test the functionality of the control buttons key-switch and display indicators. Each repeater is connected to the Morley-IAS fire alarm control panels using the RS485 peripheral data port as shown in the schematic overleaf.A maximum of 31 active repeaters can be connected to the peripheral data port. The fire alarm control panel supervises the connection between itself and the repeater proving the integrity of the cabling and indicating faults both on the repeater and the fire alarm control panel.Key FeaturesCompatible with all Morley-IAS intelligent multiprotocol fire alarm control panelsConnects to RS485 peripheral busActive or Passive optionsBacklit adjustable alphanumeric displayGeneral status LEDsControls for system reset accept mute silence alarms and self-test active repeater onlyAccess Enable key-switch on active repeater GBP 913.64 1
Morley IAS Passive Repeater Panel for DXc amp ZXSe Panels Morley IAS Passive Repeater Panel for DXc ZXSe PanelsThe Morley-IAS repeaters are compact remote-control units for Morley-IAS intelligent multi-protocol fire alarm control panels. These units along with other IO peripheral devices and the external printer further enhance the flexibility and functionality of our fire alarm control panel range. The repeaters provide an extension to the operation of the fire alarm control panel.There are two types available - passive with indications only and no controls or active with both controls and indicators. Both display the operational state of the control panel using the 80-character LCD display and the 7 LED status indicators. In addition to the general status indicators the Active repeater is fitted with key operated Access Enable switch for the control functions. Individual buttons are provided for System Reset Mute Accept Sound Alarms SilenceRe-sound Alarms and Self-test.Thus enabling control functions to be duplicated in strategic locations around the installation. The Active repeater includes an integral self-test sequence guiding the operator through a pre-set sequence to test the functionality of the control buttons key-switch and display indicators. Each repeater is connected to the Morley-IAS fire alarm control panels using the RS485 peripheral data port as shown in the schematic overleaf.Passive repeaters are not supervised but a loss of communication with the fire alarm control panel will be indicated on the passive repeater. The repeater requires an external power supply of 24Vdc nominal to operate. Power may be taken from the auxiliary supply of the control panel or from any other suitable dc power supply.Key FeaturesCompatible with all Morley-IAS intelligent multiprotocol fire alarm control panelsConnects to RS485 peripheral busActive or Passive optionsBacklit adjustable alphanumeric displayGeneral status LEDsControls for system reset accept mute silence alarms and self-test active repeater onlyAccess Enable key-switch on active repeater GBP 771.12 1
Morley DXc1 Addressable Single Loop Fire Alarm Control Panel Morley-IAS Protocol Morley DXc1 Addressable Single Loop Fire Alarm Control Panel Morley-IAS ProtocolThe DX Connexion is an enhancement of the Morley-IAS Dimension panel range connecting the traditional Morley-IAS qualities of reliability flexibility and value with advanced features and intuitive functionality.The Morley-IAS protocol DX Connexion range of fire alarm control panels has been developed to be the most time efficient fire panel on the market to install. DXc Control panels are supplied without zone LEDs. In order to connect panels together to create a network a DXc Network card and DXc Control panels are supplied without zone LEDs.Key FeaturesSingle Loop Control Panel 230Vac 2 sounder circuits.Supports the Morley-IAS protocolDims 260 x 390 x 147mm H x W x DNetwork up to 16 loops 16x1 loop panels 8x2 loop panels 4x4 loop panels or any mix up to max 16 loopsTrue peer-to-peer and fault tolerant network for high system reliabilityBS5839 part 1 compliant networkDisable all relaysEasy 5 key-press set-upsLarge blue LCD displaySupports USB uploaddownloadAlpha-numeric style keypad and navigation keysOption to upload a company logo160 zone compact mimic supportPanel buzzer mute in engineering modeUp to 72-hour standby GBP 978.36 1
Morley DXc2 Addressable 2 Loop Fire Alarm Control Panel Morley-IAS Protocol Morley DXc2 Addressable 2 Loop Fire Alarm Control Panel Morley-IAS ProtocolThe DX Connexion is an enhancement of the Morley-IAS Dimension panel range connecting the traditional Morley-IAS qualities of reliability flexibility and value with advanced features and intuitive functionality.The Morley-IAS protocol DX Connexion range of fire alarm control panels has been developed to be the most time efficient fire panel on the market to install. DXc Control panels are supplied without zone LEDs. In order to connect panels together to create a network a DXc Network card and DXc Control panels are supplied without zone LEDs.Key FeaturesTwo Loop Control Panel 230Vac 2 sounder circuits.Supports the Morley-IAS protocolDims 391.5 x 390 x 147 H x W x DNetwork up to 16 loops 16x1 loop panels 8x2 loop panels 4x4 loop panels or any mix up to max 16 loopsTrue peer-to-peer and fault tolerant network for high system reliabilityBS5839 part 1 compliant networkDisable all relaysEasy 5 key-press set-upsLarge blue LCD displaySupports USB uploaddownloadAlpha-numeric style keypad and navigation keysOption to upload a company logo160 zone compact mimic supportPanel buzzer mute in engineering modeUp to 72-hour standby GBP 1575.29 1
Morley DXc4 Addressable 4 Loop Fire Alarm Control Panel Morley-IAS Protocol Morley DXc4 Addressable 4 Loop Fire Alarm Control Panel Morley-IAS ProtocolThe DX Connexion is an enhancement of the Morley-IAS Dimension panel range connecting the traditional Morley-IAS qualities of reliability flexibility and value with advanced features and intuitive functionality.The Morley-IAS protocol DX Connexion range of fire alarm control panels has been developed to be the most time efficient fire panel on the market to install. DXc Control panels are supplied without zone LEDs. In order to connect panels together to create a network a DXc Network card and DXc Control panels are supplied without zone LEDs.Key FeaturesFour Loop Control Panel 230Vac 2 sounder circuits.Supports the Morley-IAS protocolDims 391.5 x 390 x 147 H x W x DNetwork up to 16 loops 16x1 loop panels 8x2 loop panels 4x4 loop panels or any mix up to max 16 loopsTrue peer-to-peer and fault tolerant network for high system reliabilityBS5839 part 1 compliant networkDisable all relaysEasy 5 key-press set-upsLarge blue LCD displaySupports USB uploaddownloadAlpha-numeric style keypad and navigation keysOption to upload a company logo160 zone compact mimic supportPanel buzzer mute in engineering modeUp to 72-hour standby GBP 2559.84 1
Morley PL-1000 Morley-IAS Plus Single Loop Control Panel Expandable To Two Loops Morley PL-1000 Morley-IAS Plus Single Loop Control Panel Expandable To Two LoopsThe PL-1000 control panel includes Honeywells Advanced AP protocol which maximises the speed and efficiency of alarm detection as well as providing maximum information to the installer. The 4.3 480x272 pixel touchscreen provides an intuitive user interface via its menus with quick and easy system operation. The PL-1000 control panel allows full system configuration from the screen itself.The PL-1000 is a single loop addressable panel expandable to two loops with an optional loop card PL-LIB01S. Each loop supports 159 detectors and 159 input output modules.The analogue addressable PL-1000 is designed for small to medium sized installations. The PL-1000 is very easy to install and configure. The system is designed to manage both traditional wired field devices and Agile wireless equipment. Installation and commissioning time is reduced to a minimum since the user interface allows in few steps to commission and test field devices.Due to its size and power it is the ideal analogue addressable control panel for small to medium sites where maximum information is required from the installed devices. The control panel allows the identification of each of the intelligent sensors in order to verify the state of the system before carrying out any evacuation or transmission to the alarm receiving station or to the building management system.Key Features4.3 109.2 cm touchscreen graphical colour display 480 x 272 pixel resolution with back illumination and back-lit membrane buttonsMultiple language selectionsIntuitive colour event indication tab for an overview of system status at a glanceSimple DOT Matrix Cause Effect rule builderQuick configuration of the unit from the same displayOn-screen 16 Virtual Zonal LED indicators with event colour coding to increase situational awarenessSingle loop expandable to 2 loops. 318 addresses per loop 159 detector 159 ModulesCertified to EN54-2 EN54-4 EN54-13 LVD 62.368-12014A11Morley-IAS Advanced Protocol and enhanced Agile wireless features including on-screen device battery and signal strengthsIncludes serial communication ports for TPP including Connected Life Safety Services CLSS and repeaters GBP 516.37 1
Morley 795-142 ZX5SE Door Metal Work Only Morley 795-142 ZX5SE Door Metal Work OnlyThe Morley IAS 795-142 is a replacement panel metal door for the Morley ZX5Se fire alarm control panel. GBP 766.30 1
Morley 795-004-001 ZX RS485 Communication Module Morley 795-004-001 ZX RS485 Communication ModuleRS 485 Communication module which is used with the Morley ZX panel range. The module will allow the ZX panel to communicate with peripheral panels such as repeater panels. GBP 276.08 1
Morley 795-067-001 External Paging Interface Module Morley 795-067-001 External Paging Interface Module175 x 250 x 75mm H x W x D. Supports SCOPE ASCOMTELENOVA and HLS UK Paging products and requires RS485 card to be fitted in control panel. Requires 24 Vdc supply and an RS485 card to be fitted in control panel. GBP 1628.99 1
Morley 797-064 Glass Door Kit for ZX5e Morley 797-064 Glass Door Kit for ZX5eGlass front door kit for use with the ZX5e intelligent addressable control panel. The front door is fitted with a plaxiglass window allowing protection suitable for applications what are open to the public. The front door kit is recessed within the existing panel enclosure. GBP 497.78 1
Morley DXc24 Spare Power Supply Unit 795-107 Morley DXc24 Spare Power Supply Unit 795-107DXc24 Spare Power supply unit PSU 24 loop panel GBP 727.74 1