Kidde KE-DBA-LABW-M Intelligent Addressable Detector Accessory - Label M Kidde KE-DBA-LABW-M Intelligent Addressable Detector Accessory - Label MA medium blank label for use with Excellence Series Smart Analog Detectors. GBP 4.82 1
Kidde KE-IO3101-M Excellence Series Intelligent Addressable 1 Output Mains Switching Unit With Isolator Kidde KE-IO3101-M Excellence Series Intelligent Addressable 1 Output Mains Switching Unit With IsolatorThe innovative Excellence series of intelligent addressable devices offers advanced features for reliability and peace of mind. Coupled with features for ease of installation and maintenance on new fire detection systems its a perfect match for exceptional overall performance.The Excellence series inputoutput devices are designed to provide much needed flexibility to input monitoring and output switching. These modules combined with the powerful features of a Kidde Excellence series addressable CIE give customers versatility for diverse applications.The KE-IO3101-M is an Excellence series addressable mains relay unit with integrated short circuit loop isolation. Powered directly from the Excellence loop it offers double pole potential free change-over relay contacts.Key FeaturesLoop powered saving external supply and installation costProvides an addressable mains rated output with double pole potential free change over contactsNormally Open Normally Closed programmable for full installation flexibilityFreely programmable to operate from any combination of input triggersDIN or wall mountedLocal test features for ease of validationLocal clear operation status indication for ease of use GBP 67.55 1
Kidde Airsense ADE78-0100 Digital Cable 78 Degree C - Low Smoke Zero Halogen - 100m Kidde Airsense ADE78-0100 Digital Cable 78 Degree C - Low Smoke Zero Halogen - 100mThe Kidde ADE78-0100 is a 100m roll of Digital Linear Heat Detection LHD cable with a 78C fixed temperature activation rating. The ADE range of digital sensor cables provides a very simple fixed temperature heat detection system which can be used in many applications where other forms of detection are not suitable.Alarm locationThe control unit can identify along the length of the sensor cable where an alarm condition has occurred. The alarm location is then indicated on the display of the controller. Both zones are displayed at the same time.OperationThe ADE range of digital LHD cables contains a pair of twisted low resistance tri-metallic conductors sheathed with advanced temperature sensitive polymers. The cable operates by softening the insulation of the conductors the tension of the twisted conductors then causes the two cores to fuse together. The sensor cable is used in combination with the controller and end-of-line EOL unit and can connected to any fire monitoring equipment through any monitored input i.e. conventional detection zone or addressable interface unit to signal an alarm condition.Cable fixings for all applicationsA range of edge A P and T clips allow the cable to be properly installed. The clips provide heat insulation as well as holding the cable at the correct distance from cable trays steel works ceilings and walls.Key FeaturesEN54-282016 approvedLow-Smoke Zero HalogenUp to 1000 mDetection along total cable lengthFlame retardant GBP 528.19 1
Kidde Airsense ADE88-0500 Digital Cable 88 Degree C - Low Smoke Zero Halogen - 500m - LSZH Coated Out Kidde Airsense ADE88-0100 Digital Cable 88 Degree C - Low Smoke Zero Halogen - 500m - LSZH Coated OutThe Kidde ADE88-0500 is a 500m roll of Digital Linear Heat Detection LHD cable with a 88C fixed temperature activation rating. The ADE range of digital sensor cables provides a very simple fixed temperature heat detection system which can be used in many applications where other forms of detection are not suitable.Alarm locationThe control unit can identify along the length of the sensor cable where an alarm condition has occurred. The alarm location is then indicated on the display of the controller. Both zone are displayed at the same time.OperationThe ADE range of digital LHD cables contains a pair of twisted low resistance tri-metallic conductors sheathed with advanced temperature sensitive polymers. The cable operates by softening the insulation of the conductors the tension of the twisted conductors then causes the two cores to fuse together. The sensor cable is used in combination with the controller and end-of-line EOL unit and can connected to any fire monitoring equipment through any monitored input i.e. conventional detection zone or addressable interface unit to signal an alarm condition.Cable fixings for all applicationsA range of edge A P and T clips allow the cable to be properly installed. The clips provide heat insulation as well as holding the cable at the correct distance from cable trays steel works ceilings and walls.Key FeaturesEN54-282016 approvedLow-Smoke Zero HalogenDetection along total cable lengthFlame retardant GBP 2640.92 1
Kidde Airsense ADE88-0100 Digital Cable 88 Degree C - Low Smoke Zero Halogen - 100m - LSZH Coated Out Kidde Airsense ADE88-0100 Digital Cable 88 Degree C - Low Smoke Zero Halogen - 100m - LSZH Coated OutThe Kidde ADE88-0100 is a 100m roll of Digital Linear Heat Detection LHD cable with a 88C fixed temperature activation rating. The ADE range of digital sensor cables provides a very simple fixed temperature heat detection system which can be used in many applications where other forms of detection are not suitable.Alarm locationThe control unit can identify along the length of the sensor cable where an alarm condition has occurred. The alarm location is then indicated on the display of the controller. Both zone are displayed at the same time.OperationThe ADE range of digital LHD cables contains a pair of twisted low resistance tri-metallic conductors sheathed with advanced temperature sensitive polymers. The cable operates by softening the insulation of the conductors the tension of the twisted conductors then causes the two cores to fuse together. The sensor cable is used in combination with the controller and end-of-line EOL unit and can connected to any fire monitoring equipment through any monitored input i.e. conventional detection zone or addressable interface unit to signal an alarm condition.Cable fixings for all applicationsA range of edge A P and T clips allow the cable to be properly installed. The clips provide heat insulation as well as holding the cable at the correct distance from cable trays steel works ceilings and walls.Key FeaturesEN54-282016 approvedLow-Smoke Zero HalogenDetection along total cable lengthFlame retardant GBP 528.19 1
Kidde Airsense ADE78-0500 Digital Cable 78 Degree C - Low Smoke Zero Halogen - 500m - LSZH Coated Out Kidde Airsense ADE78-0500 Digital Cable 78 Degree C - Low Smoke Zero Halogen - 500m - LSZH Coated OutThe ADE78-0500 is a 500m roll of Digital Linear Heat Detection LHD cable with a 78C fixed temperature activation rating. The ADE range of digital sensor cables provides a very simple fixed temperature heat detection system which can be used in many applications where other forms of detection are not suitable.Alarm locationThe control unit can identify along the length of the sensor cable where an alarm condition has occurred. The alarm location is then indicated on the display of the controller. Both zone are displayed at the same time.OperationThe ADE range of digital LHD cables contains a pair of twisted low resistance tri-metallic conductors sheathed with advanced temperature sensitive polymers. The cable operates by softening the insulation of the conductors the tension of the twisted conductors then causes the two cores to fuse together. The sensor cable is used in combination with the controller and end-of-line EOL unit and can connected to any fire monitoring equipment through any monitored input i.e. conventional detection zone or addressable interface unit to signal an alarm condition.Cable fixings for all applicationsA range of edge A P and T clips allow the cable to be properly installed. The clips provide heat insulation as well as holding the cable at the correct distance from cable trays steel works ceilings and walls.Key FeaturesEN54-282016 approvedLow-Smoke Zero HalogenUp to 1000 mDetection along total cable lengthFlame retardant GBP 2640.92 1
Kidde 1X-X3E-99 Conventional Fire amp Extinguishing Panel With UI - 3 Zone - Full Opt Eng Int Kidde 1X-X3E-99 Conventional Fire Extinguishing Panel With UI - 3 Zone - Full Opt Eng IntThe 1X-X3E-99 is a networkable enhanced conventional fire alarm and extinguishing control panel. It is supplied in local language with 3 fire zones that support up to 32 devices per zone. These zones may be configured for extinguishing in single zone or double zone configuration in any combination of zones. In addition the panel offers supervised outputs for first stage notification second stage notification as well as optical warning indicators and actuator activation. Standard relay outputs are provided for EN54 compliance and system status notification as well as multiple inputs for system control.The 1X fire control panels offer state of the art architecture in configurations that deliver an uncomplicated solution for small to mid-sized conventional applications. They feature an attractive contemporary design that fits with any dcor. The gently curved door front offers a distinctive flair. Operator controls are inset in a striking black lexan.With support for multiple lines of conventional detectors and accessories these quick-to-configure systems offer versatility that benefits building owners and installationmaintenance companies alike.OptionsThe panels support 2 types of auxiliary relay boards one with 4 standard relays and one with 4 supervised relays. With these boards the panel outputs may be expanded with up to 16 additional outputs. The 1X-X3E supports class A redundant ring and B standard bus networking with up to 32 nodes including conventional and addressable panels and repeaters via an optional network interface. This allows full remote control and inputs to and from other nodes in the system providing superior flexibility in system organization and planning.Key FeaturesSounders configurable for pulsing or continuous operationExtinguishing agent flow confirmationContinuous or resettable 24 VDC auxiliary supplyAuxiliary standard supervised relay output supportIntrinsically safe and EN54-13 zone support GBP 412.79 1
Kidde Airsense 1-21888-K030 Smoke Pellets Pack of 6 Kidde Airsense 1-21888-K030 Smoke Pellets Pack of 6Smoke pellets idea for testing Class C aspiration smoke detection systems.Key FeaturesPack of 6 x 13g pelletsEach pellet has a 40 sec burn time creating 18m3 of smoke GBP 11.95 1
Kidde 1X-F8 Conventional Fire Panel With UI - 8 Zones Kidde 1X-F8 Conventional Fire Panel With UI - 8 Zones1X fire control panels offer state of the art architecture in configurations that deliver an uncomplicated solution for small to mi-sized conventional applications. They feature an attractive contemporary design that fits with any decor. The gently curved door front offers a distinctive flair. Operator controls are inset in a striking black lexan.With support for multiple lines of conventional detectors and accessories these quick-to-configure systems offer versatility that benefits building owners and installationmaintenance companies alike.The 1X-F8 is a conventional fire alarm control panel. It is supplied in local language with 8 zones that support up to 32 devices per zone as well as up to 4 supervised relay outputs dedicated to sounder control. In addition 2 conventional relay outputs dedicated to common fire and fault conditions as well as two user configurable inputs for monitoring and control available.Key FeaturesModern elegant designEasy removable parts for quick and clean installationDefault regional setup modesNormal head-out intrinsically safe zone supportSupervised alarm notification outputsEN54 compliant potential free fire fault relaysClass change daynight remote reset facilitiesAuxiliary 24VDC supply output with reset support GBP 237.38 1
Kidde NC-PX3E Conventional Fire amp Extinguishing Panel With UI - 3 Zone - Full Opt Kidde NC-PX3E Conventional Fire Extinguishing Panel With UI - 3 Zone - Full OptThe New Conventional fire control panels offer state of the art architecture in configurations that deliver an uncomplicated solution for small to mid-sized conventional applications. With their clean and attractive contemporary design they fits with any dcor. The basic and intuitive user interface with icons make easy their application everywhere without an additional language kit required.With support for multiple lines of conventional detectors and accessories these quick-to-configure systems offer versatility that benefits building owners and installationmaintenance companies alike.The panelThe NC-PX3E is a networkable enhanced conventional fire alarm and extinguishing control panel. It is supplied in local language with 3 fire zones that support up to 32 devices per zone. These zones may be configured for extinguishing in single zone or double zone configuration in any combination of zones. In addition the panel offers supervised outputs for first stage notification second stage notification as well as optical warning indicators and actuator activation. Standard relay outputs are provided for EN54 compliance and system status notification as well as multiple inputs for system control.OptionsThe panels support 2 types of auxiliary relay boards one with 4 standard relays and one with 4 supervised relays. With these boards the panel outputs may be expanded with up to 16 additional outputs.The NC-PX3E supports class A redundant ring and B standard bus networking with up to 32 nodes including conventional and addressable panels and repeaters via an optional network interface. This allows full remote control and inputs to and from other nodes in the system providing superior flexibility in system organisation and planning.Approvals ComplianceThe product line carries the following accreditationsEN542 EN544 and CE approvedCPD certifiedWEEE compliantRoHS compliantKey FeaturesModern elegant design with basic and intuitive user interface with icons.Easy removable parts for quick and easy installationNormal head-out supervision support per zoneThree detection zonesSingle zone double zone or any combination of zones configurable for release6 Pre-configured relays and 8 supervised inputs for extinguishing controlConfigurable fire routing sounder extinguishing reset and door monitoring delaysConfigurable Hold Mode type-A or type-BSounders configurable for pulsing or continuous operationExtinguishing agent flow confirmationContinuous or resetable 24 VDC auxiliary supplyAuxiliary standard supervised relay output supportDefault support for special functions such as - EN54 compliant user access levels - Basic Advanced level configuration - mixed zones - front panel diagnostics with test disable control - one-man walk testRedundant networking to 1X conventional and 2X addressable nodesIntrinsically safe and EN54-13 zone support GBP 478.92 1
Kidde KE-IU3111-ZME Excellence Series Intelligent Addressable InputOutput Unit With Isolator 1 Zone - Monitoring External Power Supply Kidde KE-IU3111-ZME Excellence Series Intelligent Addressable InputOutput Unit With Isolator 1 Zone - Monitoring External Power SupplyThe innovative Excellence series of intelligent addressable devices offers advanced features for reliability and peace of mind. Coupled with features for ease of installation and maintenance on new fire detection systems its a perfect match for exceptional overall performance.The Excellence series inputoutput devices are designed to provide much needed flexibility to input monitoring and output switching. These modules combined with the powerful features of a Kidde Excellence series addressable CIE give customers versatility for diverse applications.The KE-IU3111-ZME is an Excellence series addressable 2-wire zone monitor with integrated short circuit loop isolation. It offers an interface between conventional fire devices and an Excellence series addressable CIE and enables the CIE to monitor the operation of up to 32 conventional devices in standard or up to 20 detectors in intrinsically safe configurations.Key FeaturesExternally powered allowing for the maximum number of devices to be installed on the loopProvides an addressable convectional zone for standard or intrinsic safe applicationsProvides full zone supervision for standard EN54-13 and BS5839 zone operationSupports CleanMe for reporting maintenance alerts from conventional detectorsSupports detector only MCP only and mixed zonesSupports DIN or wall mounting for installation flexibilityLocal clear operation status indication for ease of maintenanceLocal test features for ease of validation GBP 80.60 1
Kidde NC-PF8-SC Conventional Fire Panel WUI SC - 8 Z Kidde NC-PF8-SC Conventional Fire Panel WUI SC - 8 ZThe New Conventional fire control panels offer state of the art architecture in configurations that deliver an uncomplicated solution for small to mid-sized conventional applications. With their clean and attractive contemporary design they fits with any decor. The basic and intuitive user interface with icons make easy their application everywhere without an additional language kit required.With support for multiple lines of conventional detectors and accessories these quick-to-configure systems offer versatility that benefits building owners and installationmaintenance companies alike.The PanelThe 1X-F8-SC is a conventional fire alarm control panel with Scandinavian key support. It is supplied with 8 zones that support up to 32 devices per zone as well as up to 4 supervised relay outputs dedicated to sounder control and fire routing. In addition 2 conventional relay outputs dedicated to common fire and fault conditions as well as two user configurable inputs for monitoring and control are available.OptionsThe panels support 2 types of auxiliary relay boards one with 4 standard relays and one with 4 supervised relays. With these boards the panel outputs may be expanded with up to 16 additional outputs.Key FeaturesModern elegant design with basic and intuitive user interface with icons.Easy removable parts for quick and clean installationDefault regional setup modesNormal head-out intrinsically safe zone supportSupervised alarm notification fire protection outputs GBP 317.26 1
Kidde NC-PF8 Conventional Fire Panel With UI - 8 Zone Kidde NC-PF8 Conventional Fire Panel With UI - 8 ZoneThe New Conventional fire control panels offer state of the art architecture in configurations that deliver an uncomplicated solution for small to mid-sized conventional applications. With their clean and attractive contemporary design they fits with any dcor. The basic and intuitive user interface with icons make easy their application everywhere without an additional language kit required.With support for multiple lines of conventional detectors and accessories these quick-to-configure systems offer versatility that benefits building owners and installationmaintenance companies alike.The panelThe NC-PF8 is a conventional fire alarm control panel. It is supplied with 8 zones that support up to 32 devices per zone as well as up to 4 supervised relay outputs dedicated to sounder control and fire routing. In addition 2 conventional relay outputs dedicated to common fire and fault conditions as well as two user configurable inputs for monitoring and control are available.OptionsThe panels support 2 types of auxiliary relay boards one with 4 standard relays and one with 4 supervised relays. With these boards the panel outputs may be expanded with up to 8 additional outputs.Approvals ComplianceThe product line carries the following accreditationsEN542 EN544 and CE approvedCPD certifiedWEEE compliantRoHS compliantType class conditions 3K5 of IEC 60721-3-3Key FeaturesModern elegant design with basic and intuitive user interface with icons.Easy removable parts for quick and clean installationDefault regional setup modesNormal head-out intrinsically safe zone supportSupervised alarm notification outputsEN54 compliant potential free fire fault relaysClass change daynight remote reset facilitiesAuxiliary 24 VDC supply output with reset supportDefault support for special functions such as - EN54 compliant user access levels - mixed zones - full front panel diagnostics - one-man walk test - CleanMeAuxiliary standard supervised relay output boardsNetworkable up to 64 zonesNo language kit inserts required GBP 317.26 1
Kidde NC-PF4 Conventional Fire Panel With UI - 4 Zone Kidde NC-PF4 Conventional Fire Panel With UI - 4 ZoneThe New Conventional fire control panels offer state of the art architecture in configurations that deliver an uncomplicated solution for small to mid-sized conventional applications. With their clean and attractive contemporary design they fits with any dcor. The basic and intuitive user interface with icons make easy their application everywhere without an additional language kit required.With support for multiple lines of conventional detectors and accessories these quick-to-configure systems offer versatility that benefits building owners and installationmaintenance companies alike.The panelThe NC-PF4 is a conventional fire alarm control panel. It is supplied with 4 zones that support up to 32 devices per zone as well as up to 4 supervised relay outputs dedicated to sounder control and fire routing. In addition 2 conventional relay outputs dedicated to common fire and fault conditions as well as two user configurable inputs for monitoring and control are available.OptionsThe panels support 2 types of auxiliary relay boards one with 4 standard relays and one with 4 supervised relays. With these boards the panel outputs may be expanded with up to 8 additional outputs.Approvals ComplianceThe product line carries the following accreditationsEN542 EN544 and CE approvedCPD certifiedWEEE compliantRoHS compliantType class conditions 3K5 of IEC 60721-3-3Key FeaturesModern elegant design with basic and intuitive user interface with icons.Easy removable parts for quick and clean installationDefault regional setup modesNormal head-out intrinsically safe zone supportSupervised alarm notification outputsEN54 compliant potential free fire fault relaysClass change daynight remote reset facilitiesAuxiliary 24 VDC supply output with reset supportDefault support for special functions such as - EN54 compliant user access levels - mixed zones - full front panel diagnostics - one-man walk test - CleanMeAuxiliary standard supervised relay output boardsNetworkable up to 64 zonesNo language kit inserts required GBP 237.89 1
Kidde NC-PF4-SC Conventional Fire Panel With UI amp Scandinavian Key - 4 Zone Kidde NC-PF4-SC Conventional Fire Panel With UI Scandinavian Key - 4 ZoneThe New Conventional fire control panels offer state of the art architecture in configurations that deliver an uncomplicated solution for small to mid-sized conventional applications. With their clean and attractive contemporary design they fits with any decor. The basic and intuitive user interface with icons make easy their application everywhere without an additional language kit required.With support for multiple lines of conventional detectors and accessories these quick-to-configure systems offer versatility that benefits building owners and installationmaintenance companies alike.The PanelThe NC-PF4-SC is a conventional fire alarm control panel with Scandinavian key support. It is supplied with 4 zones that support up to 32 devices per zone as well as up to 4 supervised relay outputs dedicated to sounder control and fire routing. In addition 2 conventional relay outputs dedicated to common fire and fault conditions as well as two user configurable inputs for monitoring and control are available.OptionsThe panels support 2 types of auxiliary relay boards one with 4 standard relays and one with 4 supervised relays. With these boards the panel outputs may be expanded with up to 8 additional outputs.Approvals ComplianceThe product line carries the following accreditationsEN542 EN544 and CE approvedCPD certifiedNEN2535 NBNS21-100 and BS5839-1 compliantWEEE compliantRoHS compliantType class conditions 3K5 of IEC 60721-3-3Key FeaturesModern elegant design with basic and intuitive user interface with icons.Easy removable parts for quick and clean installationDefault regional setup modesNormal head-out intrinsically safe zone supportSupervised alarm notification outputsEN54 compliant potential free fire fault relaysClass change daynight remote reset facilitiesAuxiliary 24VDC supply output with reset supportDefault support for special functions such as - EN54 compliant user access levels - mixed zones - full front panel diagnostics - one-man walk test - CleanMeAuxiliary standard supervised relay output boardsNetworkable up to 64 zonesNo language kit inserts required GBP 237.89 1
Kidde NC-PF2 Conventional Fire Panel With UI - 2 Zone The New Conventional fire control panels offer state of the art architecture in configurations that deliver an uncomplicated solution for small to mid-sized conventional applications. With their clean and attractive contemporary design they fits with any dcor. The basic and intuitive user interface with icons make easy their application everywhere without an additional language kit required.With support for multiple lines of conventional detectors and accessories these quick-to-configure systems offer versatility that benefits building owners and installationmaintenance companies alike.The panelThe NC-PF2 is a conventional fire alarm control panel. It is supplied with 2 zones that support up to 32 devices per zone as well as up to 2 supervised relay outputs dedicated to sounder control. In addition 2 conventional relay outputs dedicated to common fire and fault conditions as well as two user configurable inputs for monitoring and control are available.No Language Kit required for localization.OptionsThe panels support 2 types of auxiliary relay boards one with 4 standard relays and one with 4 supervised relays. With these boards the panel outputs may be expanded with up to 8 additional outputs.Approvals ComplianceThe product line carries the following accreditationsEN542 EN544 and CE approvedCPD certifiedWEEE compliantRoHS compliantType class conditions 3K5 of IEC 60721-3-3Key FeaturesModern elegant design with basic and intuitive user interface with icons.Easy removable parts for quick and clean installationDefault regional setup modesNormal head-out intrinsically safe zone supportSupervised alarm notification outputsEN54 compliant potential free fire fault relaysClass change daynight remote reset facilitiesAuxiliary 24 VDC supply output with reset supportDefault support for special functions such as - EN54 compliant user access levels - mixed zones - full front panel diagnostics - one-man walk test - CleanMeAuxiliary standard supervised relay output boardsNetworkable up to 64 zonesNo language kit inserts required GBP 226.60 1
Kidde NC-PF2-SC Conventional Fire Panel With UI amp Scandinavian Key - 2 Zone Kidde NC-PF2-SC Conventional Fire Panel With UI Scandinavian Key - 2 ZoneThe New Conventional fire control panels offer state of the art architecture in configurations that deliver an uncomplicated solution for small to mid-sized conventional applications. With their clean and attractive contemporary design they fits with any decor. The basic and intuitive user interface with icons make easy their application everywhere without an additional language kit required.With support for multiple lines of conventional detectors and accessories these quick-to-configure systems offer versatility that benefits building owners and installationmaintenance companies alike.The PanelThe NC-PF2-SC is a conventional fire alarm control panel with Scandinavian key support. It is supplied with 2 zones that support up to 32 devices per zone as well as up to 2 supervised relay outputs dedicated to sounder control. In addition 2 conventional relay outputs dedicated to common fire and fault conditions as well as two user configurable inputs for monitoring and control are available.OptionsThe panels support 2 types of auxiliary relay boards one with 4 standard relays and one with 4 supervised relays. With these boards the panel outputs may be expanded with up to 8 additional outputs.Approvals ComplianceThe product line carries the following accreditationsEN542 EN544 and CE approvedCPD certifiedNEN2535 NBNS21-100 and BS5839-1 compliantWEEE compliantRoHS compliantType class conditions 3K5 of IEC 60721-3-3Key FeaturesModern elegant design with basic and intuitive user interface with icons.Easy removable parts for quick and clean installationDefault regional setup modesNormal head-out intrinsically safe zone supportSupervised alarm notification outputsEN54 compliant potential free fire fault relaysClass change daynight remote reset facilitiesAuxiliary 24VDC supply output with reset supportDefault support for special functions such as - EN54 compliant user access levels - mixed zones - full front panel diagnostics - one-man walk test - CleanMeAuxiliary standard supervised relay output boardsNetworkable up to 64 zonesNo language kit inserts required GBP 226.60 1
Kidde NC-PX3 Conventional Fire amp Extinguishing Panel With UI - 3 Zone Kidde NC-PX3 Conventional Fire Extinguishing Panel With UI - 3 ZoneThe New Conventional fire control panels offer state of the art architecture in configurations that deliver an uncomplicated solution for small to mid-sized conventional applications. With their clean and attractive contemporary design they fits with any dcor. The basic and intuitive user interface with icons make easy their application everywhere without an additional language kit required.With support for multiple lines of conventional detectors and accessories these quick-to-configure systems offer versatility that benefits building owners and installationmaintenance companies alike.The panelThe NC-PX3 is a conventional fire alarm and extinguishing control panel. It is supplied in local language with 3 fire zones that support up to 32 devices per zone. These zones may be configured for extinguishing in single zone or double zone configuration in any combination of zones. In addition the panel offers supervised outputs for first stage notification second stage notification as well as optical warning indicators and actuator activation. Standard relay outputs are provided for EN54 compliance and system status notification as well as multiple inputs for system control.OptionsThe panels support 2 types of auxiliary relay boards one with 4 standard relays and one with 4 supervised relays. With these boards the panel outputs may be expanded with up to 16 additional outputs.Approvals ComplianceThe product line carries the following accreditationsEN542 EN544 and CE approvedCPD certifiedWEEE compliantRoHS compliantKey FeaturesModern elegant design with basic and intuitive user interface with icons.Easy removable parts for quick and easy installationNormal head-out supervision support per zoneThree detection zonesSingle zone double zone or any combination of zones configurable for release6 Pre-configured relays and 8 supervised inputs for extinguishing controlConfigurable fire routing sounder extinguishing reset and door monitoring delaysConfigurable Hold Mode type-A or type-BSounders configurable for pulsing or continuous operationExtinguishing agent flow confirmationContinuous or resettable 24 VDC auxiliary supplyAuxiliary standard supervised relay output supportDefault support for special functions such as - EN54 compliant user access levels - Basic Advanced level configuration - mixed zones - front panel diagnostics with test disable control - one-man walk test GBP 349.60 1
Kidde Airsense AAECU EN 54-22 Analogue LHD Composite Control Unit Alarmline II EN54 Kidde Airsense AAECU EN 54-22 Analogue LHD Composite Control Unit Alarmline II EN54The AAECU analogue control unit is provided with an LCD and internal control buttons to be able to calibrate and configure the control unit without a laptop.Key FeaturesSensor cable length - Min 30.5m Max 500mSupply voltage 20-28VDCCurrent consumption Quiescent - 70mA maxAlarm - 100mA max 2 x Volt free outputs Alarm Pre-Alarm rated 2A 30VDC0.25A 250VAC1 x Opto Isolated output Fault rated 20mA 50VDC1 x Isolated input Reset requires 20-28VDC pulse for min 5sAlarm and Pre-Alarm temperature range 54 - 100 Deg C 129 - 212 Deg F4 LED indicators Red - Alarm Red Pre-Alarm Amber - Fault Power GreenPolycarbonate enclosureIngress rating IP66 Dimensions mm 182w x 182h x 90d MUST be used with AAE cable GBP 1309.99 1
Kidde KE-DP3020W Excellence Series Intelligent Addressable Dual Optical Smoke Detector - White Kidde KE-DP3020W Excellence Series Intelligent Addressable Dual Optical Smoke Detector - WhiteThe innovative Excellence range of intelligent addressable devices offers advanced features for reliability and peace of mind. Coupled with features for ease of installation and maintenance on new fire detection systems its a perfect match for exceptional overall performance.The DP3020W is a Kidde Excellence series signal white addressable dual optical detector. It combines a low profile design with tri-colour status indication with 360 visibility. A remote indicator output is available as standard that supports a remote indicator up to 30 m away. Detection reliability is ensured by combining dual optical wavelengths with multiple detection angles. This allows for state-of-the-art particle size detection that differentiates between real sources of alarm or nuisance sources such as dust and steam.Key FeaturesRemote indicator output with short circuit isolation for additional device protectionNuisance alarm steam dust discrimination for peace of mindTri-colour indicators for alarm pre alarm isolation fault. ItsMe and communications takes the guesswork out of operational status360 indicator visibility means no device alignment to ensure visibilityNew mechanical rotary addressing for easy addressingAll alarm levels EN54 certified GBP 32.36 1
Kidde Airsense EST-XCTRLINE-4 Function Card 4 IN 8 OUT Audio RS485 Kidde Airsense EST-XCTRLINE-4 Function Card 4 IN 8 OUT Audio RS485EST-xCTRLN-4 provides 4 independent speaker line outputs A B C D. Card allows to switch between main and spare amplifiers. Line measurement methods can be made by Impedance Loop or End of Line Module EOL. The measurement method is selected from the software configuration.EST-xCTRLN-4 provides fault detection opening ground leakage and surveillance amplifiers on common 100 V Buses.Key FeaturesCurrent consumption 152 mA max. for 48 VPower supply Internal form the Control Unit backplaneType of connector 10 pin screw terminal type PHOENIX 5.08 mmImpedance measurement frequency 1 kHz to 48 kHzFrequency of the signal for EOL modules 18 kHz to 24 kHzMaximum measured current 20 AMaximum measured voltage 200 VAccuracy of measurement Up to 5Physical dimensions 70 x 215 x 30 mm W x H x D GBP 638.90 1
Kidde KE-DT3101W-HAB Excellence Series Intelligent Addressable Category AB Heat With ISO - White Kidde KE-DT3101W-HAB Excellence Series Intelligent Addressable Category AB Heat With ISO - WhiteThe innovative Excellence range of intelligent addressable devices offers advanced features for reliability and peace of mind. Coupled with features for ease of installation and maintenance on new fire detection systems its a perfect match for exceptional overall performance.The DT3101W-HAB is a Kidde Excellence series signal white addressable heat detector with integrated short circuit isolation. It supports EN54 Class A with static and rate-of-rise temperature response as well as Class B with rate-of-rise response. It combines a low profile design with tri-colour status indication with 360 visibility. A remote indicator output is available as standard that supports a remote indicator up to 30 m away.Key FeaturesIntegrated loop short circuit isolation ensures operation during a single short circuit on the loopShort circuit isolation on remote output for additional device protectionStatic and rate-of-rise temperature supportTri-colour indicators for alarm pre alarm isolation fault. ItsMe and communications takes the guesswork out of operational status360 indicator visibility means no device alignment to ensure visibilityNew mechanical rotary addressing for easy addressingEvent logging in the device for diagnostics purposes when neededAll alarm levels EN54 certified GBP 41.39 1
Kidde Airsense EST-S136 Complete Fire Ceiling Speaker - Power 6W 100V - Diameter 13 cm Kidde Airsense EST-S136 Complete Fire Ceiling Speaker - Power 6W 100V - Diameter 13 cmCeiling-mounted fire alarm loudspeakers EST-S106 and EST-S136 are designed for applications which require the minimum size at the maximum sound quality. Their parameters have been carefully selected to match the operating requirements in the rooms exposed to after-sound and high-humidity. Thanks to the most advanced technologies the EST-S series loudspeakers combine excellent acoustic parameters and high aesthetics with resistance to mechanical damages and varying weather conditions.They are distinguished by easy and quick installation. Quality standards and audio characteristics have been confirmed through multiple tests and trials employing such facilities as e.g. echo proof chamber resistance and integrity testing equipment as well as chambers for resistance to weather and air humidity testing. The need to maintain the best acoustic parameters even with easily installed fire-protecting screens was the idea underlying the design process.The EST-S series loudspeakers ensure a balanced sound which is extremely important in emission of highly understandable speech and reliable music reproduction. The series of ceiling-mounted EST-S loudspeakers is noticeable thanks to its elegant looks. The loudspeaker part which becomes visible after the installation is protected by means of electroplating and covered by a common and aesthetic white paint coat RAL 9003 optionally available other colours RAL palette.The entire EST-S series is equipped with a standardized fire dome made of soft steel and supplied with two cable penetrations with rubber glands. Special jig for sling assembling facilitates quick installation. The delivery comprises the 1 m long sling. Two ceramic blocks and fireproof wiring coupled with temperature limit fuse are located under the screen. This solution ensures 100 protection of the sound transmitting line from any break or short-circuits which may be produced as a result of loudspeaker burn. The EST-S loudspeakers have been successfully tested by means of the most rigorous trials at the temperature of 822C. The individual power rating is selected by means of connection with applicable transformer branch.EST-S series loudspeakers equipped with fire dome and thermal protections entirely comply with EN 54-24 Standards. In order to ensure 100 consistency with the highest quality standards we test our loudspeakers following the most meticulous procedures that warrant high parameters of sound emission safety and reliability. In spite of the fact our loudspeakers are designed for the highest reliability under fire conditions their acoustic parameters and attractive low prices make them successful in any and all public address systems.Key FeaturesCompliance with EN 54-24Certificate of Conformity 1438-CPR-XXXXMinimum dimensionsA and C working environment ideal for bathroomsThe highest level of verbal communication understandingElegant looks6 W transformer allowing a precise selection of loudspeaker output power100 protection of line from breaks and short-circuits at the temperature of 822C GBP 46.09 1
NC-DBO Conventional Beam Detector - Reflective NC-DBO Conventional Beam Detector - ReflectiveThe NC-DBO is a reflective infrared beam smoke detector for use in conventional fire detection systems. Being microprocessor based the detector offers extensive algorithms for analysis and decision making. Taking ambient operating conditions into consideration system adjustments such as drift compensation and alarm and fault analysis are automatic. The sensitivity of the detector is adjustable to suit various application conditions.InstallationThe number of reflectors in a system varies depending on the required operating distance detection range of the detector. Optical reflectors from 1 to 4 provide an effective range of the detector between 5 and 100m. Four reflectors are supplied with the beam. The detection range of the beam can be selected from 4 levels with the hand held programmer NC-D-PT. For very short range detection 10 m a non reflective mask NRM9105 is recommended to attenuate the reflector.Key FeaturesWide operating voltage rangeLarge protection areaCombination of transmitter receiver in one housingallows for easy installation and optical alignmentIntelligent microprocessor based decision making on fire andfault statusesEasy alignment and commissioning with onboard laser andsignal level indicationSelf-diagnostics for monitoring reporting internalfailuresAutomatic drift compensation compensates for changingenvironmental conditions dust and dirt accumulation building movement andchanging internal component specifications due to ageingOnboard NO fire and NC fault dry contact outputs for easysupervisionFour selectable sensitivity levels for wideapplication coverage GBP 426.44 1
Kidde KE-DP3021W Excellence Series Intelligent Addressable Dual Optical SmokeHeat Detector - White Kidde KE-DP3021W Excellence Series Intelligent Addressable Dual Optical SmokeHeat Detector - WhiteThe innovative Excellence range of intelligent addressable devices offers advanced features for reliability and peace of mind. Coupled with features for ease of installation and maintenance on new fire detection systems its a perfect match for exceptional overall performance.The DP3021B is a Kidde Excellence series graphite black addressable dual optical and heat detector. It combines a low profile design with tri-colour status indication with 360 visibility. A remote indicator output is available as standard that supports a remote indicator up to 30 m away.Detection reliability is ensured by combining dual optical wavelengths with multiple detection angles. This allows for state-of-the-art particle size detection that differentiates between real sources of alarm or nuisance sources such as dust and steam. As a temperature detector Class A static and rate-of-rise modes are supported to further widen the application footprint.Key FeaturesRemote indicator output with short circuit isolation for additional device protectionNuisance alarm steam dust discrimination for peace of mindStatic and rate-of-rise temperature supportTri-colour indicators for alarm pre alarm isolation fault. ItsMe and communications takes the guesswork out of operational status360 indicator visibility means no device alignment to ensure visibilityNew mechanical rotary addressing for easy addressingEvent logging in the device for diagnostics purposes when neededAll levels sensitivity EN54 certified GBP 40.76 1