Kentec K719 Sigma CP Replacement Panel PCB Conventional Sigma CP 8 Zone 3 and 4 Kentec K719 Sigma CP Replacement Panel PCB Conventional Sigma CP 8 Zone 3 and 4A replacement Sigma CP panel PCB.Key Features8 zones 3 4Replacement or spare product GBP 229.68 1
Kentec K21083M4 Sigma XT 8 Zone 3 Area Extinguishing Control Panel Kentec K21083M4 Sigma XT 8 Zone 3 Area Extinguishing Control PanelSigma XT control panels are multi-area extinguishant control panels complying with EN12094-1 EN54-2 and EN54-4. Up to 8 zones of conventional detection with up to 4 extinguishant areas are available. Stand-alone extinguishant control units are also available with 2 monitored inputs to receive initiating signals from remote fire detection control panels or addressable modules. Each extinguishant area has a comprehensive set of inputs and outputs and is configurable via a simple programming interface.All extinguishant areas may have up to 7 serially connected Sigma Si status indication and control units or ancillary relay boards connected via a simple 4 core cable. The versatility of the control panel can be enhanced further by the fitting of up to 7 Sigma CP Ancillary boards K580 or Sigma CP Sounder boards K461 to the RS485 serial bus. See data sheet DS39 and DS48. For compatible status units see Sigma Si data sheet DS41.Key Features Approved to EN12094-1 EN54-2 and EN54-4 2 4 or 8 detection zones 1 to 4 extinguishant areas Dual extinguishant outputs for each area configurable as MainReserve First and second stage sounder outputs for each area First and second stage volt free changeover contacts for each area Released volt free contact per area Fault volt free contact per area Programmable extinguishant delays Programmable output duration Extract fan control Countdown indicator shows time until release in seconds Mode select and manual release controls per area Monitored remote manual release input Monitored remote Hold input Monitored remote Mode select door interlock input Monitored remote Released pressure switch input Monitored remote Low Pressure switch input Monitored Abort input Serial connection for Sigma Si status units and ancillary boards Dual action manual extinguishing release control AutoManual keyswitch 3 Amp power supply 230V AC input GBP 1667.65 1
Kentec K1848-00 Replacement Panel PCB - 8 Zones Kentec K1848-00 Replacement Panel PCB - 8 ZonesReplacement panel PCB with connections for 8 zone circuits. GBP 397.42 1
Kentec K583B Sigma CP-R Replacement Panel PCB 24V version 8 Zone E01080L2 Kentec K583B Sigma CP-R Replacement Panel PCB 24V version 8 Zone E01080L2Sigma CP-R Replacement Panel PCB 24V version 8 Zone E01080L2Key FeaturesReplacement Panel PCB for Sigma CP-R Fire Control Panel Repeaters.Available for 24V or 230V versions and either 2 4 or 8 zones. GBP 204.85 1
Kentec K575B Sigma CP-R Replacement Panel PCB 230V version 8 Zone K01080L2 Kentec K575B Sigma CP-R Replacement Panel PCB 230V version 8 Zone K01080L2Sigma CP-R Replacement Panel PCB 230V version 8 Zone K01080L2Key FeaturesReplacement Panel PCB for Sigma CP-R Fire Control Panel Repeaters.Available for 24V or 230V versions and either 2 4 or 8 zones. GBP 204.85 1
Kentec K446C Sigma CP Replacement Panel PCB Conventional Sigma CP 8 Zone K11080M2 Kentec K446C Sigma CP Replacement Panel PCB Conventional Sigma CP 8 Zone K11080M2The Kentec K446C is a replacement panel pcb for use with the Kentec 8 zone Sigma CP 4 wire conventional control panel Part code K11080M2. GBP 238.58 1
Kentec K764 Sigma CP-A Replacement Panel PCB - Two Wire Sigma CP-A 8 Zone Kentec K764 Sigma CP-A Replacement Panel PCB - Two Wire Sigma CP-A 8 ZoneThe K764 is a Sigma CP-A Replacement Panel PCB - Two Wire Sigma CP-A 8 Zone. GBP 303.08 1
Kentec K449C Sigma CP Replacement Panel PCB Two Wire Sigma CP 8 Zone T11080M2 Kentec K449C Sigma CP Replacement Panel PCB Two Wire Sigma CP 8 Zone T11080M2The Kentec K449C is a replacement panel PCB for use with the Kentec 8 zone Sigma CP two wire control panel Part code T11080M2. GBP 303.08 1
Kentec K21084M4 Sigma XT 8 Zone 4 Area Extinguishing Control Panel 8 Zone Conventional Kentec K21084M4 Sigma XT 8 Zone 4 Area Extinguishing Control Panel 8 Zone ConventionalSigma XT control panels are multi-area extinguishantcontrol panels complying with EN12094-1 EN54-2 and EN54-4. Up to 8 zones ofconventional detection with up to 4 extinguishant areas are available.Standalone extinguishant control units are also availablewith 2 monitored inputs to receive initiating signals from remote firedetection control panels or addressable modules.Each Extinguishant area has a comprehensive set of inputsand outputs and is configurable via a simple programming interface. Allextinguishant areas may have up to 7 serially connected Sigma SI statusindication and control units or ancillary relay boards connected via a simple 4core cable. The versatility of the control panel can be enhanced further by thefitting of up to 7 Sigma CP Ancillary boards K580 or Sigma CP Sounder boards.Key FeaturesApproved to EN12094-1 EN54-2 and EN54-42 4 or 8 detection zones1 to 4 extinguishant areasDual extinguishant outputs for each area configurable as MainReserveFirst and second stage sounder outputs for each areaFirst and second stage volt free changeover contacts for each areaReleased volt free contact per areaFault volt free contact per areaProgrammable extinguishant delaysProgrammable output durationExtract fan controlCountdown indicator shows time until release in secondsMode select and manual release controls per areaMonitored remote manual release inputMonitored remote Hold inputMonitored remote Mode select door interlock inputMonitored remote Released pressure switch inputMonitored remote Low Pressure switch inputMonitored Abort input GBP 2019.97 1
Kentec Sigma XT Extinguishant Control Panel to BS EN12094-1 2 - 8 Zone Kentec Sigma XT Extinguishant Control Panel to BS EN12094-1 2 - 8 ZoneSigma XT control panels are multi-area extinguishant control panels complying with EN12094-1 EN54-2 and EN54-4. Up to 8 zones of conventional detection with up to 4 extinguishant areas are available. Stand-alone extinguishant control units are also available with 2 monitored inputs to receive initiating signals from remote fire detection control panels or addressable modules. Each extinguishant area has a comprehensive set of inputs and outputs and is configurable via a simple programming interface.All extinguishant areas may have up to 7 serially connected Sigma Si status indication and control units or ancillary relay boards connected via a simple 4 core cable. The versatility of the control panel can be enhanced further by the fitting of up to 7 Sigma CP Ancillary boards K580 or Sigma CP Sounder boards K461 to the RS485 serial bus. See data sheet DS39 and DS48. For compatible status units see Sigma Si data sheet DS41.Key FeaturesApproved to EN12094-1 EN54-2 and EN54-42 4 or 8 detection zones1 to 4 extinguishant areasDual extinguishant outputs for each area configurable as MainReserveFirst and second stage sounder outputs for each areaFirst and second stage volt free changeover contacts for each areaReleased volt free contact per areaFault volt free contact per areaProgrammable extinguishant delaysProgrammable output durationExtract fan controlCountdown indicator shows time until release in secondsMode select and manual release controls per areaMonitored remote manual release inputMonitored remote Hold inputMonitored remote Mode select door interlock inputMonitored remote Released pressure switch inputMonitored remote Low Pressure switch inputMonitored Abort inputSerial connection for Sigma Si status units and ancillary boards. K588Part NumberDescriptionK21021M3Sigma XT 2 Zone Extinguishant Control Panel 1 Area SurfaceK21041M3Sigma XT 4 Zone Extinguishant Control Panel 1 Area SurfaceK21042M3Sigma XT 4 Zone Extinguishant Control Panel 2 Area SurfaceK21081M3Sigma XT 8 Zone Extinguishant Control Panel 1 Area SurfaceK21082M3Sigma XT 8 Zone Extinguishant Control Panel 2 Area SurfaceK21083M4Sigma XT 8 Zone Extinguishant Control Panel 3 Area Surface larger PSU 5.25AK21084M4Sigma XT 8 Zone Extinguishant Control Panel 4 Area Surface larger PSU 5.25A GBP 734.00 1
Kentec B1830 Replacement Enable Control Switch 3 position old K3000 range Kentec B1830 Replacement Enable Control Switch 3 position old K3000 rangeReplacement Enable Control Switch 3 position old K3000 range GBP 19.97 1
Kentec T11080M2 Sigma CP Two Wire Surface Panel - 8 Zones Kentec T11080M2 Sigma CP Two Wire Surface Panel - 8 Zones The Kentec T11080 M2 is a 8 Zone Two Wire Fire Alarm Control Panel from the Sigma CP range of two wire fire alarm control panels.This panel allows the installation of detectors call points sounders and beacons all on the same zone circuit. This allows a reduction in installation costs and time when compared to traditional conventional fire alarm systems that require separate detection and sounder circuits.The Kentec T11080 M2 is designed to be surface mounted panel ideal for installations where the cables for the system are to be on the surface of the fabric of the building.Key Features2-wire and standard versions in 2 4 or 8 zonesCompatible for use on BS5839Part 1 2002 installations2-wire repeaters and ancillary boardsFully programmable using simple menu optionsSimple single board constructionInstaller friendlyCompatible with a wide range of detection devicesTwo monitored sounder outputs3Amp power supplyAuxiliary power output GBP 386.92 1
Kentec Syncro 8 Way Relay Extender Board K547 Kentec Syncro 8 Way Relay Extender BoardK547To further enhance the versatility of the Syncro fire alarm system additional relay output capability can be added using Syncro relay boards. These boards have 8 voltage free changeover relay contacts each of which can be individually programmed. Up to 32 of these boards can be connected to the dedicated RS485 communications bus in the control panel giving the capability of up to 256 additional relay outputs. Consideration must be taken as to the loading on the main panel.Key Features8 volt free changeover relay contacts 1Amp 30V DCRelay operated indicationsRemote connection to panel via RS485 serial busCommon footprint to other Syncro IO board typesAll outputs programmable for cause and effectsCan be used with other Syncro IO modules on the same panelCompatible with Syncro AS panels GBP 287.72 1
Kentec K21082M3 Sigma XT 8 Zone 2 Area Extinguishing Control Panel Kentec K21082M3 Sigma XT 8 Zone 2 Area Extinguishing Control PanelSigma XT control panels are multi-area extinguishant control panels complying with EN12094-1 EN54-2 and EN54-4. Up to 8 zones of conventional detection with up to 4 extinguishant areas are available. Stand-alone extinguishant control units are also available with 2 monitored inputs to receive initiating signals from remote fire detection control panels or addressable modules. Each extinguishant area has a comprehensive set of inputs and outputs and is configurable via a simple programming interface.All extinguishant areas may have up to 7 serially connected Sigma Si status indication and control units or ancillary relay boards connected via a simple 4 core cable. The versatility of the control panel can be enhanced further by the fitting of up to 7 Sigma CP Ancillary boards K580 or Sigma CP Sounder boards K461 to the RS485 serial bus. See data sheet DS39 and DS48. For compatible status units see Sigma Si data sheet DS41.Key Features Approved to EN12094-1 EN54-2 and EN54-4 2 4 or 8 detection zones 1 to 4 extinguishant areas Dual extinguishant outputs for each area configurable as MainReserve First and second stage sounder outputs for each area First and second stage volt free changeover contacts for each area Released volt free contact per area Fault volt free contact per area Programmable extinguishant delays Programmable output duration Extract fan control Countdown indicator shows time until release in seconds Mode select and manual release controls per area Monitored remote manual release input Monitored remote Hold input Monitored remote Mode select door interlock input Monitored remote Released pressure switch input Monitored remote Low Pressure switch input Monitored Abort input Serial connection for Sigma Si status units and ancillary boards Extinguishing controls and status indicators Dual action manual extinguishing release control AutoManual keyswitch Integral 3 Amp power supply 230V AC input GBP 1350.56 1
Kentec K1420329 Relay Unit cw 3 x 2 Pole co 10 Amp Relay Surface Kentec K1420329 Relay Unit cw 3 x 2 Pole co 10 Amp Relay SurfaceRelay Unit cw 3 x 2 Pole co 10 Amp Relay Surface GBP 126.60 1
Kentec K21081M3 Sigma XT 8 Zone 1 Single Area Extinguishing Control Panel Kentec K21081M3 Sigma XT 8 Zone 1 Single Area Extinguishing Control PanelSigma XT control panels are multi-area extinguishant control panels complying with EN12094-1 EN54-2 and EN54-4. Up to 8 zones of conventional detection with up to 4 extinguishant areas are available. Stand-alone extinguishant control units are also available with 2 monitored inputs to receive initiating signals from remote fire detection control panels or addressable modules. Each extinguishant area has a comprehensive set of inputs and outputs and is configurable via a simple programming interface.All extinguishant areas may have up to 7 serially connected Sigma Si status indication and control units or ancillary relay boards connected via a simple 4 core cable. The versatility of the control panel can be enhanced further by the fitting of up to 7 Sigma CP Ancillary boards K580 or Sigma CP Sounder boards K461 to the RS485 serial bus. See data sheet DS39 and DS48. For compatible status units see Sigma Si data sheet DS41.Key Features Approved to EN12094-1 EN54-2 and EN54-4 2 4 or 8 detection zones 1 to 4 extinguishant areas Dual extinguishant outputs for each area configurable as MainReserve First and second stage sounder outputs for each area First and second stage volt free changeover contacts for each area Released volt free contact per area Fault volt free contact per area Programmable extinguishant delays Programmable output duration Extract fan control Countdown indicator shows time until release in seconds Mode select and manual release controls per area Monitored remote manual release input Monitored remote Hold input Monitored remote Mode select door interlock input Monitored remote Released pressure switch input Monitored remote Low Pressure switch input Monitored Abort input Serial connection for Sigma Si status units and ancillary boards Extinguishing controls and status indicators Dual action manual extinguishing release control AutoManual keyswitch Integral 3 Amp power supply 230V AC input GBP 1174.42 1
Kentec K41208FST Disabled Refuge 8 Line Central Unit with OLED Display - Loop Wired Flush Mounting Kentec K41208FST Disabled Refuge 8 Line Central Unit with OLED Display - Loop Wired Flush MountingThe Disabled Refuge 8 Line Central Unit can answer or call out to each multiple or all of the Safe-Point disabled refuge outstations by activating the corresponding fascia push-buttons. Once connected full duplex conversations can take place and calls are ended by simply replacing the integrated handset.Accompanying LED indicators and an internal buzzer notify of any disabled refuse alarms raised. A fascia located momentary push-button provides lamp-test and buzzer silence functionality. Added LEDs provide power health and system fault indications.The unit is wired to disabled refuge outstations by a loop type circuit. Any toilet alarm kit can be wired in line with an accompanying disable refuge callanswer point.There is space for 7Ah batteries provided within the cabinet these will provide 24 3 hours standby as specified by BS5839 Part 9.The unit is available in surface or flush mount enclosure options comprising a mild steel back box with stainless steel fascia plate including a tamper resistant vision window cover.Key Features8x Callanswer outstation inputsSimple handset operationAlarm indicators and internal buzzerPower on and system fault indicatorsLamp test and silence buzzer push buttonLoop or radial Outstation connection optionsEnable In Fire input to prevent non-essential callsIntegrated display to show custom alarm informationTamper resistant vision window cover GBP 2371.82 1
Kentec Sigma CP 8 Zone Conventional Fire Alarm Panel K11080M2 Kentec Sigma CP 8 Zone Conventional Fire Alarm Panel K11080M2The Sigma CP range consists of a series of conventional fire alarm control panels designed in accordance with European standards BS EN54-2 and BS EN54-4 Fire Detection and Fire Alarm systems - Control and Indicating Equipment. The range consists of 2 4 and 8 zone control panels.All control panels are available in two versionsSigma K11range in which detectors and call points are wired on separate circuits to sounders two sounder circuits are provided.Sigma T11range in which detectors call points and sounders are wired to the same pair of cables. Commonly referred to as a two-wire system.Wiring sounders to the detection circuits eliminates the need to install sounder circuit cables and also offers the ability to provide zoned or two stage sounder operation. T series only All control panels have an integral mains powered battery charger and power supply designed in accordance with the requirements of BS EN54-4.Key FeaturesFully certified to BS EN54-2 and BS EN54-42-wire and standard versions in 2 4 or 8 zonesCompatible for use on BS5839 Part 1 2002 installations2-wire repeaters and ancillary boardsSimple single board constructionInstaller friendlyCompatible with wide range of detection devicesTwo monitored sounder outputs3 Amp power supplyAuxiliary power outputFully programmable using simple menu optionsAdjustable sounder delay timeSounder configuration optionsZonal sounder delay detectors onlyZonal sounder delay call points onlyCoincidence input selectionI.S Barrier selection by zoneShort circuit fire by zoneNon latching zonesSilent zonesZone input delayGeneral panel configuration GBP 361.14 1
Kentec K41208SST Disabled Refuge 8 Line Central Unit with OLED Display - Loop Wired Surface Mounting Kentec K41208SST Disabled Refuge 8 Line Central Unit with OLED Display - Loop Wired Surface MountingThe Disabled Refuge 8 line Central Unit can answer or call out to each multiple or all of the Safe-Point disabled refuge outstations by activating the corresponding fascia push-buttons. Once connected full duplex conversations can take place and calls are ended by simply replacing the integrated handset.Accompanying LED indicators and an internal buzzer notify of any disabled refuse alarms raised. A fascia located momentary push-button provides lamp-test and buzzer silence functionality. Added LEDs provide power health and system fault indications.The unit is available in two installation versions allowing wiring to disabled refuge outstations to be made either radially or over a loop. Any toilet alarm kit can be wired in line with an accompanying disable refuge callanswer point.Space for 7Ah batteries is provided within the cabinet these will provide 24 3 hours standby as specified by BS5839 Part 9.The unit is available in surface or flush mount enclosure options comprising a mild steel back box with stainless steel fascia plate including a tamper resistant vision window cover.Key FeaturesDisable Refuge Combined Master Panel8x Callanswer outstation inputsSimple handset operationAlarm indicators and internal buzzerPower on and system fault indicatorsLamp test and silence buzzer push buttonLoop or radial Outstation connection optionsEnable In Fire input to prevent non-essential callsIntegrated display to show custom alarm informationTamper resistant vision window cover GBP 2714.06 1
Kentec Sigma CP-R 24v Repeater Panel with Low Profile Enclosure 2 - 8 Zone Kentec Sigma CP-R 24v Repeater Panel with Low Profile Enclosure 2 - 8 ZoneThe Sigma CP-R Repeater is compatible with all Sigma CP control panels which have operating software version V2.0 or above. Repeaters are available with 2 4 or 8 zones and in mains powered K versions or 24V powered E versions. Mains powered repeaters require only a two core data cable from the main control panel. 24V DC versions require an additional two cores for power either from the main panel or from another 24V DC source.A mixture of Repeaters Ancillary boards or Sounder Boards up to a maximum of 7 of each type can be connected to a control panel and each is allocated an address from 1 to 7 using a binary coded DIL switch. The total length of the data cable from the main panel to the last repeater must not exceed 1200 metres.Key FeaturesTwo wire serial connectionUp to 7 panels per system230V AC or 24V DC powered versionsFull control over main panelVolt free fire and fault contact outputsPart NumberDescriptionE01020L2Sigma CP-R Conventional Repeater Panel 24V version low profile enclosure 2 Zones SurfaceE01040L2Sigma CP-R Conventional Repeater Panel 24V version low profile enclosure 4 Zones SurfaceE01080L2Sigma CP-R Conventional Repeater Panel 24V version low profile enclosure 8 Zones Surface GBP 201.43 1
Kentec K41108FST Disabled Refuge 8 Line Central Unit with OLED Display Kentec K41108FST Disabled Refuge 8 Line Central Unit with OLED DisplayThe master panel can answer or call out to each multiple or all of the Safe-Point disabled refuge outstations by activating the corresponding fascia push-buttons. Once connected full duplex conversations can take place and calls are ended by simply replacing the integrated handset.Accompanying LED indicators and an internal buzzer notify of any disabled refuse alarms raised. A fascia located momentary push-button provides lamp-test and buzzer silence functionality. Added LEDs provide power health and system fault indications.The unit is available in two installation versions allowing wiring to disabled refuge outstations to be made either radially or over a loop. Any toilet alarm kit can be wired inline with an accompanying disable refuge callanswer point.Space for 7Ah batteries is provided within the cabinet these will provide 24 3 hours standby as specified by BS5839 Part 9.The unit is available in surface or flush mount enclosure options comprising a mild steel back box with stainless steel fascia plate including a tamper resistant vision window cover.Key FeaturesRadial WiredFlush mounting8x Callanswer outstation inputsSimple handset operationAlarm indicators and internal buzzerPower on and system fault indicatorsLamp test and silence buzzer push buttonLoop or radial Outstation connection optionsEnable In Fire input to prevent non-essential callsIntegrated display to show custom alarm informationTamper resistant vision window cover GBP 2450.78 1
Kentec RIM100M-3-K InputOutput Module For RIM100-E Ethernet LinkTwo Inputs To Monitor Kentec RIM100M-3-K InputOutput Module For RIM100-E Ethernet LinkTwo Inputs To MonitorThe RIM100M-3-K provides a bi-directional InputOutput interface for relaying system states to RIM100E-K Ethernet modules. The RIM100M-3-K links to the RIM100E-K modules via an RS485 interface. The RIM100M-3-K supports two signal inputs and three relay outputs.The two inputs can typically be used to transfer the status of Fire and Fault states from a fire panel across a monitored link between twoRIM100E-K modules. All relay outputs are driven by signal states presented by the RIM100E-K module.The RIM100M-3-K activates an external relay contact based on the state of the monitored communication link between local and remote paired RIM100E-K modules.The module is housed in a DIN rail mountable enclosure with LED status indication visible on the front fascia of the module.Key FeaturesTwo bi-directional InputOutput signal states communicated across a link with RIM100E-K modulesSupports a simple monitored communication channel with configurable latencyAn effective solution for introducing a remote conventional Fire Alarm Control Panel to an existing network via a monitored communication channelSupport for debug via laptop with simple USB interfaceProduct is DIN rail mountableSimple LED system status indication for fire fault and monitored link GBP 1022.52 1
Kentec Sigma CP-R Repeater Panel with 230v PSU amp Standard Enclosure 2 - 8 Zone Kentec Sigma CP-R Repeater Panel with 230v PSU Standard Enclosure 2 - 8 ZoneThe Sigma CP-R Repeater is compatible with all Sigma CP control panels which have operating software version V2.0 or above. Repeaters are available with 2 4 or 8 zones and in mains powered K versions or 24V powered E versions. Mains powered repeaters require only a two core data cable from the main control panel. 24V DC versions require an additional two cores for power either from the main panel or from another 24V DC source.A mixture of Repeaters Ancillary boards or Sounder Boards up to a maximum of 7 of each type can be connected to a control panel and each is allocated an address from 1 to 7 using a binary coded DIL switch. The total length of the data cable from the main panel to the last repeater must not exceed 1200 metres.Key FeaturesSigma CP-R Two wire serial connectionUp to 7 panels per system230V AC or 24V DC powered versionsFull control over main panelVolt free fire and fault contact outputsAncillary PCB Two wire serial connectionUp to 7 boards per system230V AC or 24V DC powered versionsOpen collector zonal fault outputsVolt free fire coincidence and common fault contact outputsVariants AvailablePart NumberDescriptionK01020M2Sigma CP-R Conventional Repeater Panel with PSU 230V standard enclosure 2 Zones SurfaceK01040M2Sigma CP-R Conventional Repeater Panel with PSU 230V standard enclosure 4 Zones SurfaceK01080M2Sigma CP-R Conventional Repeater Panel with PSU 230V standard enclosure 8 Zones Surface GBP 295.45 1
Kentec K01080M2 Sigma CP-R 8 - Zone Conventional Repeater Panel with PSU2 Kentec K01080M2 Sigma CP-R 8 - Zone Conventional Repeater Panel with PSU2The Sigma CP-R Repeater is compatible with all Sigma CP control panels which have operating software version V2.0 or above. Repeaters are available with 2 4 or 8 zones and in mains powered K versions or 24V powered E versions. Mains powered repeaters require only a two core data cable from the main control panel. 24V DC versions require an additional two cores for power either from the main panel or from another 24V DC source.A mixture of Repeaters Ancillary boards or Sounder Boards up to a maximum of 7 of each type can be connected to a control panel and each is allocated an address from 1 to 7 using a binary coded DIL switch. The total length of the data cable from the main panel to the last repeater must not exceed 1200 metres.Key Features Sigma CP-R Two wire serial connection Up to 7 panels per system 230V AC or 24V DC powered versions Full control over main panel Volt free fire and fault contact outputs Ancillary PCB Two wire serial connection Up to 7 boards per system 230V AC or 24V DC powered versions Open collector zonal fault outputs Volt free fire coincidence and common fault contact outputs GBP 366.24 1
Kentec E01080L2 Sigma CP-R Low Profile Enclosure Conventional Repeater Panel 8 Zone No PSU2 Kentec E01080L2 Sigma CP-R Low Profile Enclosure Conventional Repeater Panel 8 Zone No PSU2The Sigma CP-R Repeater is compatible with all Sigma CP control panels which have operating software version V2.0 or above. Repeaters are available with 2 4 or 8 zones and in mains powered K versions or 24V powered E versions. Mains powered repeaters require only a two core data cable from the main control panel. 24V DC versions require an additional two cores for power either from the main panel or from another 24V DC source.A mixture of Repeaters Ancillary boards or Sounder Boards up to a maximum of 7 of each type can be connected to a control panel and each is allocated an address from 1 to 7 using a binary coded DIL switch. The total length of the data cable from the main panel to the last repeater must not exceed 1200 metres.Key Features Two wire serial connection Up to 7 panels per system 230V AC or 24V DC powered versions Full control over main panel Volt free fire and fault contact outputs GBP 254.51 1