Hochiki TCH-B200 New ESP Address Programmer Hochiki TCH-B200 New ESP Address ProgrammerModel TCH-B200 is a hand held address programmer designed to address the ESP range of Sensors and all other addressable devices such as wall sounders mini-modules and manual call points.The unit is designed to be light robust and easy to use and operates from a single PP3 size battery which gives the capacity for up to 8000 operations. The programmer is also capable of displaying the sensor analogue values.The TCH-B200 ESP Programmer is designed for use with the following productsALK ALG-ALNcAnalogue Photoelectric SensorsAIE-EcAnalogue Ionisation SensorATG-EcAnalogue Heat SensorCHQ-WS2cWall SounderATJ ACB-Ec ACB-EW2Analogue Multi-Heat SensorsCHQWSBWSB2cWall Sounder BeaconsACC ACA-EcAnalogue Multi-SensorsYBO-BScBase SounderYBO-BSBBSB2cBase Sounder BeaconsHCP Range3Analogue Manual Call PointsCHQ-CBWBABcAddressable BeaconsCHQ-POM3Powered Output ModuleCHQ-SIM3Single Input ModuleCHQ-ARIcAddressable Remote Indicator C device clips straight onto Programmer 2 in conjunction with PL-2 Programming Lead 3 in conjunction with PL-3 Programming LeadThe programmer is used to set the address of the above products for use with Hochiki ESP systems. The unit is designed to be light robust and easy to use and operates from a single PP3 size heavy-duty battery which gives the capacity for up to 8000 operations. Please Note the TCH-B200 comes complete with the PL-3 lead. GBP 96.80 1
Hochiki Plant Control Module with SCI CHQ-PCMSCI Hochiki CHQ-PCMSCI Plant Control Module with SCIThe CHQ-PCMSCI is a loop powered inputoutput module with four independent change-over relay outputs and four monitored inputs. The outputs feature NO and NC volt free contacts and can be driven separately under the control of the fire alarm panel to be used for the control of devices such as dampers or for plant and equipment shutdown. The four inputs are provided for local fire and fault monitoring and these are fully monitored for open and short circuit which if required can be enabled or disabled in pairs using a two-way DIL switch.The unit is also available in a DIN Rail mountable enclosure CHQ-PCMDINSCI. A back box is also available CHQ-BACKBOX which when used in conjunction with the CHQ-PCMSCI increases the IP rating to IP65. When using heavy cables we recommend the use of the SMB-1 Module Enclosure in conjunction with the SMB-ADAPTOR plate.Key FeaturesSingle loop addressLoop powered4 change-over relay outputs4 independent inputs for monitoring of volt-free contactsEach input can be configured to monitor either Normally Open or Normally Closed contactsDIN rail version availableBoth models feature an integral short-circuit isolatorApproved by LPCBPlease Note The state of the relay contacts will be indeterminate until the unit is powered. GBP 124.74 1