27 results (0,12817 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

Haes HS-5201 1-2 Loop Analogue Control Panel with 1 Loop

Haes HS-5201 1-2 Loop Analogue Control Panel with 1 Loop

Haes HS-5201 1-2 Loop Analogue Control Panel with 1 LoopThe HS-5200 series of control panels are fully expandable from 1 - 2 loops and supplied with 2 on-board sounder circuits 20 programmable zonal LEDs with slide-in labels and 25 system LEDs for information purposes. There are also 4 programmable function buttons with LED indication for confirmation of operation. The control panel consists of the latest dual flash-based microprocessor technology combined with a high resolution high contrast graphical LCD display and tactile keypad providing a simple Select Click programming aid for engineer configuration and end-user operation.Powerful cause and effect programming coupled with DynamiX zoning and enhanced Trace Diagnostics makes the panel suitable for a wide range of site applications from small to large complex multi-area systems. The panel is fully programmable on-site via the on-board alphanumeric keypad or PC-NeT configuration software. An extensive suite of user-friendly Windows based PC software programs have been developed to enhance your experience when using the Elan series of fire panels.The suite incorporates a number of different programmes to include a Configuration Service Logo and Virtual Panel Tool to allow the flexibility of the equipment to be fully explored. Simply adding a network card allows the panel to communicate with any other Elan fire panel current range of Advanced Electronics fire panels Remote Terminal or Network Peripheral such as ipGateway or BMSGraphical Interface. The network operates as a true peer-to-peer system and can be configured in a fault-tolerant loop or radial format.Key FeaturesFully approved to EN54 part 2 4 13 and CE marked under the Construction Products Regulation CPRGlobal complianceOpen protocol system3 year warranty as standardLarge graphical LCD user interfacePowerful cause effects programmingTrue peer to peer networkingOn board printer option M enclosure only20 zonal LED indicatorsProgrammable push buttons

GBP 1373.53
1

Haes HS-5401 1-4 Loop Analogue Control Panel with 1 Loop

Haes HS-5401 1-4 Loop Analogue Control Panel with 1 Loop

Haes HS-5401 1-4 Loop Analogue Control Panel with 1 LoopThe HS-5400 series of control panels are fully expandable from 1 to 4 loops and supplied with 4 on-board sounder circuits 20 programmable zonal LEDs with slide-in labels and 25 systems LEDs for information purposes. There are also 4 programmable function buttons with LED indication for confirmation of operation. The control panel consists of the latest dual flash-based microprocessor technology combined with a high resolution high contrast graphical LCD display and tactile keypad providing a simple Select Click programming aid for engineer configuration and end-user operation.Powerful cause and effect programming coupled with DynamiX zoning and enhanced Trace Diagnostics makes the panel suitable for a wide range of site applications from small to large complex multi-area systems. The panel is fully programmable on-site via the on-board alphanumeric keypad or PC-NeT configuration software.An extensive suite of user-friendly Windows based PC software programs have been developed to enhance your experience when using the Elan series of fire panels.The suite incorporates a number of different programmes to include a Configuration Service Logo and Virtual Panel Tool to allow the flexibility of the equipment to be fully explored. Simply adding a network card allows the panel to communicate with any other Elan fire panel current range of Advanced Electronics fire panels Remote Terminal or Network Peripheral such as ipGateway or BMSGraphical Interface. The network operates as a true peer-to-peer system and can be configured in a fault-tolerant loop or radial format.Key FeaturesFully approved to EN54 part 2 4 13 and CE marked under the Construction Products Regulation CPRGlobal complianceOpen protocol system3 year warranty as standardLarge graphical LCD user interfacePowerful cause effects programmingTrue peer to peer networkingOn board printer option M enclosure only20 zonal LED indicators Programmable push buttons

GBP 1965.37
1

Haes HS-5401D 1-4 Loop Control Panel cw 1 Loop Card - Large Deep Enclosure

Haes HS-5401D 1-4 Loop Control Panel cw 1 Loop Card - Large Deep Enclosure

Haes HS-5401D 1-4 Loop Control Panel cw 1 Loop Card - Large Deep EnclosureThe HS-5400 series of control panels are fully expandable from 1 to 4 loops and supplied with 4 on-board sounder circuits 20 programmable zonal LEDs with slide-in labels and 25 systems LEDs for information purposes. There are also 4 programmable function buttons with LED indication for confirmation of operation. The control panel consists of the latest dual flash-based microprocessor technology combined with a high resolution high contrast graphical LCD display and tactile keypad providing a simple Select Click programming aid for engineer configuration and end-user operation.Powerful cause and effect programming coupled with DynamiX zoning and enhanced Trace Diagnostics makes the panel suitable for a wide range of site applications from small to large complex multi-area systems. The panel is fully programmable on-site via the on-board alphanumeric keypad or PC-NeT configuration software.An extensive suite of user-friendly Windows based PC software programs have been developed to enhance your experience when using the Elan series of fire panels.The suite incorporates a number of different programmes to include a Configuration Service Logo and Virtual Panel Tool to allow the flexibility of the equipment to be fully explored. Simply adding a network card allows the panel to communicate with any other Elan fire panel current range of Advanced Electronics fire panels Remote Terminal or Network Peripheral such as ipGateway or BMSGraphical Interface. The network operates as a true peer-to-peer system and can be configured in a fault-tolerant loop or radial format.Key FeaturesFully approved to EN54 part 2 4 13 and CE marked under the Construction Products Regulation CPRGlobal complianceOpen protocol system3 year warranty as standardLarge graphical LCD user interfacePowerful cause effects programmingTrue peer to peer networking20 zonal LED indicatorsProgrammable push buttonsLarge deep enclosure

GBP 2024.94
1

Haes ESA-1007 1 to 4 Loops Apollo Addressable Panel

Haes ESA-1006 1 to 2 Loops Apollo Addressable Panel

Haes ESA-1002 1 to 4 Loops Argus Addressable Panel

Haes ESA-1001 1 to 2 Loops Argus Addressable Panel

Haes Red Fire Alarm Mains Isolate Switch with Back Box - FAIS-R-B

Haes ESG-1003 Esprit Ext Control Panel Dual Flood Area 3.4A PSU

Haes ESG-1001 Esprit-G Extinguishant Control Panel Single Flood Area 1.2A PSU

Haes ESG-1001 Esprit-G Extinguishant Control Panel Single Flood Area 1.2A PSU

Haes ESG-1001 Esprit-G Extinguishant Control Panel SingleFlood Area 1.2A PSUThe Esprit extinguishant release control panels are fullyconfigurable to control automatic extinguishant release scenarios. The single flood area control panel has 3 detection circuitsand support for metron and solenoid type actuators. Programmable countdowntimers are provided for Extinguishant Delay Extinguishant Duration FloodingTime and Extract Time. The control panel has a large graphical display witheasy to navigate menus. Remote status units are available as well as remoteHold Off Abort Buttons.Esprit-G panelssupport a large range of conventional detectors including Apollo Hochiki Nittan. The panels are supplied with a 1.2 or 3.4 amp internal switchmode power supply module. This module complies with the requirements of EN54-4 1988 and provides temperature compensated battery management charging.Esprit-G panels are approved to European standards EN12094-1 EN54-2 EN54-4.Key FeaturesSingle flooding area3 detection zonesApproved to EN12094-1 EN54- 2 EN54-4Fully configurable zone voting for gas release4 programmable sounder circuitsConfigurable sounder delaysZero time delay option for manual call pointsCompatible with IS barriersNon-latching zone input optionExtinguishant delay 0-60 secondsExtinguishant duration 1-300 secondsFlooding time 60-1800secondsExtract time 1-90 minutesGraphical back lit LCD displayAccess controls via key switch or code entryTime and date stamped event logAlarm counterCompany logo can be programmed in displayRS 485 communications for remote status unitsKey switch status controlFire fault stage signal relays2 amp actuator circuitHold abort flow switch manual release mode control andpressure switch monitoring inputs1.2 amp PSU for 7Ah batteries

GBP 432.04
1

Haes ESEN-2MAR-B MED Approved Esento 2 Zone Control Panel - Black

Haes Lockdown Alert Alarm Relay

Haes TPCA01-E4MAR Marine Approved TPC Esento 4 Zone Main Processor Zone PCB

Haes ESG-1002 Esprit Extinguishant Control Panel Single Flood Area 3.4A PSU

Haes ESEN-4MAR 4 Zone Conventional Esento MED Marine Approved Control Panel

Haes ESEN-4MAR 4 Zone Conventional Esento MED Marine Approved Control Panel

Haes ESEN-4MAR 4 Zone Conventional Esento MED Marine Approved Control PanelThe Esento Marine 2-4 panel is available with 2 or 4 conventional zones. The programming features include programmable muster alarm zones and a false alarm management mode. As standard all Esento Marine 2-4 panels provide two monitored sounder circuits Fire Fault VFCO relays and inputs to ring and pulse the sounder circuits. A separate interface card is also available to connect the panel to a ships voyage data recorder system.The panels are supplied with a 1.25 amp internal power supply module. This module complies with the requirements of EN54-4 1988 and provides temperature compensated battery management charging. Esento Marine panels are approved to European standards EN54-2 4 Fire Detection and Alarm Systems Control Indicating Equipment.Essento Marine OverviewThe Esento Marine range from Haes has been exclusively developed to address the issues of limited form and function in the conventional panels market for use at sea. Designed with the severity of the potential situation in mind these new panels are equipped with programmable delays to outputs which allow time for an investigation before invoking a full evacuation or muster alarm.Not only does this new feature-rich panel mitigate false alarms with three false alarm management mode options it also contains additional components within the casing to ensure its not disrupted by increased vibrations encountered during a journey.The panels are available from 2 - 12 zones and offer a fully comprehensive suite of programmable features for the engineer. The display uses super bright clearly labelled LED indicators and the simple colour coded buttons give the end user the confidence to correctly manage their fire alarm system.Key Features2 or 4 zonesActivate controls via keyswitch or code entryCompatible with Apollo Orbis Marine detectorsIntegral detector removal monitoringEarth fault monitoring1.25 Amp switch mode power supply Nom 27V DC2 monitored sounder outputs2 Aux CO relays 1 x Fire 1 x Fault. voltage freeClass change IPAlert IPFire fault switched -ve outputsFalse alarm modeMuster alarm featureTest mode with or without soundersDisable zones sounder OPs aux OPsAlarm load 800mA shared between all sounder outputsAll sounder circuits are fused 500mA with resettable fuses.N.B. No networking or repeater panels

GBP 379.13
1

Haes ESEN-2MAR 2 Zone Conventional Esento MED Marine Approved Control Panel

Haes ESEN-2MAR 2 Zone Conventional Esento MED Marine Approved Control Panel

Haes ESEN-2MAR 2 Zone Conventional Esento MED Marine Approved Control PanelThe Esento Marine 2-4 panel is available with 2 or 4 conventional zones. The programming features include programmable muster alarm zones and a false alarm management mode. As standard all Esento Marine 2-4 panels provide two monitored sounder circuits Fire Fault VFCO relays and inputs to ring and pulse the sounder circuits. A separate interface card is also available to connect the panel to a ships voyage data recorder system.The panels are supplied with a 1.25 amp internal power supply module. This module complies with the requirements of EN54-4 1988 and provides temperature compensated battery management charging. Esento Marine panels are approved to European standards EN54-2 4 Fire Detection and Alarm Systems Control Indicating Equipment.Essento Marine OverviewThe Esento Marine range from Haes has been exclusively developed to address the issues of limited form and function in the conventional panels market for use at sea. Designed with the severity of the potential situation in mind these new panels are equipped with programmable delays to outputs which allow time for an investigation before invoking a full evacuation or muster alarm.Not only does this new feature-rich panel mitigate false alarms with three false alarm management mode options it also contains additional components within the casing to ensure its not disrupted by increased vibrations encountered during a journey.The panels are available from 2 - 12 zones and offer a fully comprehensive suite of programmable features for the engineer. The display uses super bright clearly labelled LED indicators and the simple colour coded buttons give the end user the confidence to correctly manage their fire alarm system.Key Features2 or 4 zonesActivate controls via keyswitch or code entryCompatible with Apollo Orbis Marine detectorsIntegral detector removal monitoringEarth fault monitoring1.25 Amp switch mode power supply Nom 27V DC2 monitored sounder outputs2 Aux CO relays 1 x Fire 1 x Fault. voltage freeClass change IPAlert IPFire fault switched -ve outputsFalse alarm modeMuster alarm featureTest mode with or without soundersDisable zones sounder OPs aux OPsAlarm load 800mA shared between all sounder outputsAll sounder circuits are fused 500mA with resettable fuses.

GBP 318.82
1

Haes ESEN-12MAR 12 Zone Conventional Esento MED Marine Approved Control Panel

Haes ESEN-12MAR 12 Zone Conventional Esento MED Marine Approved Control Panel

Haes ESEN-12MAR 12 Zone Conventional Esento MED Marine Approved Control PanelThe Esento Marine 8-12 panel is available from 8 to 12 conventional zones. All inputs and outputs are fully programmable and there are options to have delays to the outputs. The programming features also include a muster alarm feature and 3 different modes to help reduce false alarms. As standard all Esento Marine 8-12 panels provide four monitored sounder circuits Fire Fault VFCO relays Fire Fault switched negative outputs and inputs to ring and pulse the sounder circuits.A fully functional repeater panel is available via a plug in comms PCB. A separate interface card is also available to connect the panel to a ships voyage data recorder system. The panels are supplied with a 3.0 amp internal power supply module. This module complies with the requirements of EN54-4 1988 and provides temperature compensated battery management charging. Esento Marine panels are approved to European standards EN54-2 4 Fire Detection and Alarm Systems Control Indicating Equipment.Essento Marine OverviewThe Esento Marine range from Haes has been exclusively developed to address the issues of limited form and function in the conventional panels market for use at sea. Designed with the severity of the potential situation in mind these new panels are equipped with programmable delays to outputs which allow time for an investigation before invoking a full evacuation or muster alarm.Not only does this new feature-rich panel mitigate false alarms with three false alarm management mode options it also contains additional components within the casing to ensure its not disrupted by increased vibrations encountered during a journey.The panels are available from 2 - 12 zones and offer a fully comprehensive suite of programmable features for the engineer. The display uses super bright clearly labelled LED indicators and the simple colour coded buttons give the end user the confidence to correctly manage their fire alarm system.Key Features8 - 12 zonesActivate controls via keyswitch or code entryCompatible with Apollo Orbis Marine detectorsIntegral detector removal monitoringEarth fault monitoring3 Amp switch mode power supply Nom 27V DC4 monitored sounder outputs2 Aux CO relays 1 x Fire 1 x Fault. voltage freeClass change IPAlert pulsing IPFire fault switched -ve outputsProgram delays to ouputsFalse alarm modes A B CMuster alarmTest mode with or without soundersDisable zones sounder OPs aux OPs delaysAlarm load 2.4A shared between all sounder outputsAll sounder circuits are fused 500mA with resettable fuses.

GBP 789.85
1