Global Fire CHAMELEON-REPBLK Chameleon Control Repeater cw RS422 Network Card - Black Global Fire CHAMELEON-REPBLK Chameleon Control Repeater cw RS422 Network Card - BlackThe CHAMELEON REP is the best solution when you need full control of a networked system. In a Chameleon Network the CHAMELEON REPEATER is used as a System Repeater.It works as an addressed networked control panel without loops and has the ability to process and register Event-log all system info.For connection diagrams and project commissioning please refer to the Chameleon Network manual as well as the manual of the Communication Interface being used.The graphical backlit LCD display can accommodate any type of custom characters or graphic symbols allowing multi-language support as well as pictorial and customisable elements.The CHAMELEON REP is supplied without battery management capability. It is intended to be connected to an external power supply.The Cause-and-Effect programming of the whole system as well as all customer specific configuration can be downloaded or uploaded using the CHAMELEON CONNECTOR software and later broadcast to other networked control panels.Key FeaturesNetwork Compatibility with the OCTO NODE and GEKKO range of control panelsConnection to the control panels via RS422 Fibre-Optic or TCPIPEvent log 10000 eventsBacklit graphical LCD display of 240 x 64 pixelsProgramming by integrated keypad or Loader PC softwareMultiple language support menu selectableColour Black GBP 487.16 1
Global Fire CHAMELEON-REP Chameleon Control Repeater cw RS422 Network Card Global Fire CHAMELEON-REP Chameleon Control Repeater cw RS422 Network CardThe CHAMELEON REP is the best solution when you need full control of a networked system. In a Chameleon Network the CHAMELEON REPEATER is used as a System Repeater.It works as an addressed networked control panel without loops and has the ability to process and register Event-log all system info.For connection diagrams and project commissioning please refer to the Chameleon Network manual as well as the manual of the Communication Interface being used.The graphical backlit LCD display can accommodate any type of custom characters or graphic symbols allowing multi-language support as well as pictorial and customisable elements.The CHAMELEON REP is supplied without battery management capability. It is intended to be connected to an external power supply.The Cause-and-Effect programming of the whole system as well as all customer specific configuration can be downloaded or uploaded using the CHAMELEON CONNECTOR software and later broadcast to other networked control panels.Key FeaturesNetwork Compatibility with the OCTO NODE and GEKKO range of control panelsConnection to the control panels via RS422 Fibre-Optic or TCPIPEvent log 10000 eventsBacklit graphical LCD display of 240 x 64 pixelsProgramming by integrated keypad or Loader PC softwareMultiple language support menu selectable. GBP 462.80 1
Global Fire GEKKO-2 2 Loop Control Panel Global Fire GEKKO-2 2 Loop Control PanelThe GEKKO Fire Alarm Control Panel is the successor of the enormously popular GFE JUNIOR panel.The GEKKO can have from 1 to 4 addressable loops. It is housed in a functional ABS plastic enclosure with only two screws used to close and secure the lid.The new graphic backlit LCD display can accommodate any type of custom characters or graphic symbols allowing multi-language support as well as pictorial and customisable elements.It can naturally also communicate with our proprietary ODYSSEY Graphics Interface as well as with third party Building Management Systems through a Modbus output. It is also capable to communicate with a Repeater unit using any of the networking interfaces of the CHAMELEON protocol.Inside the cabinet there is space for installing up to 7 AH 24V DC Sealed Lead Acid backup batteries providing battery supply to the GEKKO and ZEOS associated devices which boast extremely low current consumption.The Cause and Effect programming as well as all customer specific configuration is introduced in the GEKKO using the CHAMELEON CONNECTOR software which is then downloaded to the Flash Memory of the unit.Key Features2 loop panelNetworkable panel compatible with OCTO and NODE range of panelsSupports connection to Repeaters via RS422 Fibre-Optic or TCPIP250 devices per loop 125 address limitUp to 95 VULCAN 2 addressable ultra low current base sounders 32 address limit32 individually programmable sounder addressesFull Self-Addressable Devices support2 Fire output relays change-over and 1 Fault relay NC - opens on fault2 conventional alarm outputs individually programmableBoth detection loops monitored for integrity384 fully programmable zones512 fully programmable sounder groups512 IO groupsEvent log rolling 10000 entriesAvailable only with ZEOS protocolCompatible with all our own low cost ancillary modulesBacklit graphical LCD display of 240x64 pixelsProgramming by integrated keypad or Loader PC softwareMultiple language support menu selectableIntegrated 16 zone LED fire zone indication GBP 671.47 1
Global Fire Equipment GEKKO-2BLK GEKKO 2 Loop Control Panel Anthracite Global Fire Equipment GEKKO-2BLK GEKKO 2 Loop ControlPanel AnthraciteThe GEKKO Fire Alarm Control Panel is the successor to GFEswell-known JUNIOR V4 panel.The GEKKO can have from 1 to 4 addressable loops. It ishoused in a functional ABS plastic enclosure with only two screws used toclose and secure the lid.The new graphic backlit LCD display can accommodate any typeof custom characters or graphic symbols allowing multi-language support aswell as visual and customisable elements.It can communicate with our proprietary ODYSSEY GraphicsInterface as well as with third party Building Management Systems through aModbus output. It is also capable of communicating with a repeater unit usingany of the networking interfaces of the CHAMELEON protocol.Inside the cabinet there is space to install up to 7 AH 24VDC Sealed Lead Acid backup batteries providing battery supply to the GEKKO andZEOS associated devices which boast extremely low energy consumption.The Cause and Effect programming as well as allcustomer-specific configuration is introduced in the GEKKO using the CHAMELEONCONNECTOR software which is then downloaded to the flash memory of the unit.Key FeaturesSuccessor to GFEs JUNIOR V4 panel1 to 4 loop panel 2 loop cards installedSupports connection to Repeaters via RS422 Fibre-Optic orTCPIPNetworkable panel compatible with OCTO and NODE range ofpanelsUp to 250 devices per loop only 125 addresses availableUp to 95 VULCAN 2 addressable ultra low current basesounders 32 address limit32 individually programmable sounder addressesFull self-addressable devices support2 Fire output relays change-over and 1 fault relay NC -opens on fault2 conventional alarm outputs Individually programmableBoth detection loops monitored for integrity512 fully programmable sounder and IO groups384 fully programmable zonesEvent log rolling 10000 entriesAvailable only with ZEOS protocolCompatible with all GFE manufactured ancillary modulesBacklit graphical LCD display of 240x64 pixelsProgramming by integrated keypad or Loader PC softwareMultiple language support menu selectableIntegrated 16 zone LED fire zone indicationEN54-13 EN54-2 EN54-4 1328-CPR-0737 certified GBP 671.47 1