Fireclass 557.202.080FC TLI800EN EN54 Approved Network Card Fireclass 557.202.080FC TLI800EN EN54 Approved Network CardThe use of the FireClass Network allows the fragmentation of a number of fire controllers to be drawn into a network system.The Fireclass Net communications network comprises a collection of network interface modules and peripheral equipment that together form a fault resistant and flexible peer-to-peer network for the Fireclass Digital addressable fire systems controllers.One TLI800EN is required per FireClass and is installed onto the FireClass Main Processor board.The TLI800EN is used toConnect up to 24 Fireclass panels or other nodes to a single networkConnect the Emergency display used to display an alarm in case of a System faultSupported network communications mediaShielded twisted pair copper cable RS485 standardFibre optic cable multimode 50125m or 62.5125 mKey FeaturesAll field wiring terminations connect via removable terminal blocksTwo RS-485 connections for twisted pair network communicationsEarth fault detection and isolationOnboard diagnostic LEDs. These indicate network communications activity and TLI800EN module faultsTwo Micro Controller Units. One is used as a backup microprocessor. These provide MCU fault detection and Emergency Mode fire alarm monitoring in the case of MCU failureFire Alarm input Fire Alarm output and RS-485 Emergency Display connections for use in Emergency Mode GBP 564.25 1
Fireclass 557.200.039FC TLI800ENG with PSU Fireclass 557.200.039FC TLI800ENG with PSUThe use of the FireClass Network allows the fragmentation of a number of fire controllers to be drawn into a network system.The Fireclass Net communications network comprises a collection of network interface modules and peripheral equipment that together form a fault resistant and flexible peer-to-peer network for the Fireclass Digital addressable fire systems controllers.One TLI800ENG is required per FireClass and is installed onto the FireClass Main Processor board. It is provided boxed complete with PSU.The TLI800ENG is used toConnect up to 24 Fireclass panels or other nodes to a single networkConnect the Emergency display used to display an alarm in case of a System faultSupported network communications mediaShielded twisted pair copper cable RS485 standardFibre optic cable multimode 50125m or 62.5125mKey FeaturesAll field wiring terminations connect via removable terminal blocksTwo RS-485 connections for twisted pair network communicationsEarth fault detection and isolationOnboard diagnostic LEDs. These indicate network communications activity and TLI800EN module faultsTwo Micro Controller Units. One is used as a backup microprocessor. These provide MCU fault detection and Emergency Mode fire alarm monitoring in the case of MCU failureFire Alarm input Fire Alarm output and RS-485 Emergency Display connections for use in Emergency Mode GBP 922.07 1