12 results (0,13990 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

Fireclass 508.033.751FC Prescient III Extinguishing Control Panel

Fireclass 508.033.751FC Prescient III Extinguishing Control Panel

Fireclass 508.033.751FC Prescient III Extinguishing Control PanelThe Prescient III gaseous extinguishant control panel is powerful yet user-friendly and is designed and manufactured to a high standard. The panel features approval to BSEN 12094-12003 BSEN 54-2 and 4 and is designed to BS7273 part 1.The panel has extensive configuration options but is easy to install programme and operate. The removable chassis enables the engineer to first fix an empty cabinet and then fit the chassis at the commissioning stage. This is supported by comprehensive documentation on commissioning operating maintenance and fault finding. In addition there is a comprehensive range of compatible accessories available to meet most customer requirements.Key FeaturesComprehensive facilities for gaseous extinguishing systemsApproval to BSEN 12094-12003 additional optionsApproval to BSEN 54-2 and 4Designed to BS7273-12000Monitored inputs for gas discharged gas low isolation valve closedabnormal gas trapped in manifoldControl inputs for automanual gas hold gas abort1 minute actuator cut off optionMonitored actuatorsolenoid releaseExtensive disablement optionsCommon fire fault relay monitored output facilities1st stage 2nd stage 3rd stage and gas discharged relay monitored output facilitiesReset relay facilitiesIntrinsically safe barrier settingsMetron or solenoid compatibleSingle or double knock operationPre-discharge delay adjustable from 0 to 60 secondsDischarged indication with or without pressure switchInhibit silence alarms until gas dischargedLatching or non latching fault indication optionOption for rapid buzzer pulse when gas imminentSemi-flush bezel and fully-flush cabinet options availableOne man zone and sounder testEasily removable chassis

GBP 671.05
1

Fireclass 509.030.113FC Extinguishing Release Manual Call Point EN12094

Fireclass 509.030.116FC Extinguishing Abort Weatherproof Manual Call Point EN12094

Fireclass 509.030.115FC Extinguishing Abort Manual Call Point EN12094

Fireclass 509.030.114FC Extinguishing Release Weatherproof Manual Call Point EN12094

Fireclass 516.016.028FC LHD Junction EOL Box

Fireclass 540.001.038FC XB8 Intrinsically Safe Xenon Beacon

Fireclass 576.501.053FC IS28 MK6 Banshee Sounder

Fireclass 516.016.018FC ProReact Analogue End Of Line Unit

Fireclass 540.001.039FC XB11 Flameproof Xenon Beacon

Fireclass 516.016.027FC Digital Interface 2-Zone Monitor Module

Fireclass 516.016.027FC Digital Interface 2-Zone Monitor Module

Fireclass 516.016.027FC Digital Interface 2-Zone Monitor ModuleA Unique and Flexible dual zone Digital LHD Interface Monitor Module offering advanced functionality to traditional Digital LHD systems.A further important addition to Thermocables world leading family of digital linear heat detection technologies the ProReact Interface Monitor Module is designed to work with the ProReact Digital Linear Heat Detection Cable and effectively monitor up to two zones at any one time.The Digital Interface Monitor Module is unique in being approved to the UL864 10th edition standard the most recent revision to the UL standard for fire alarm control panels and accessories. It has been designed and tested against the stringent requirements of the 10th edition including new tests to confirm the integrity of the software in the device. The Digital Interface Monitor Module simultaneously monitors two zones of Digital LHD cable for an alarm or fault condition. If an overheat or fire situation triggers either zone of the Digital LHD cable the Module automatically calculates and displays the distance along the cable in feet and metres to the alarm point. The two zones can operate independently of each other or in interlockcoincidence detection mode to eliminate the possibility of false alarms.The Module is intended to be installed between the Digital Linear Heat Detection cable and a conventional or addressable fire alarm control panel. An RS-485 Modbus RTU output also allows direct connection into a PLC or other process control system.Typical ApplicationsPower generation industriesOil and gas industriesMinesCold storage and industrial freezersFloating roof storage tanksTunnelsCable traysWarehousingKey FeaturesAdvanced functionality for traditional Digital LHD systemsPinpoints exact location of an incident and responds immediatelySimultaneous monitoring of up to two zonesPower indicator fault and alarm lights for each zoneVolt-free outputs for fault and alarm corresponding to each zoneCan be connected to an industrial process control system using the two-wire RS485 Modbus RTU outputBuilt-in sounder for audible annunciationInterlockCoincidence detection eliminates the possibility of false alarms by requiring both LHD cables to trigger before transmitting an alarmUL CE RoHS approved to meet end user specificationsSimultaneous monitoring of up-to two zones increases potential applications. For example pre-alarm on one zonealarm on the other fault-tolerant triggering of alarm both zones must activate before alarm at panelImmediately pinpoints exact location and responds to an incidentCompatible with Thermocables ProReact Digital LHD cableCan be retro-fitted to existing installationsCost effectively increases functionality and performanceConnects to addressable fire alarm control panels for fast response to faultsLow installation and maintenance costs reduce total cost of ownershipReliability through design approvals and 3 year warranty

GBP 515.16
1