17 results (0,14120 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

Fireclass FC500PS PSTN Board for FC500 Fire Panels

Fireclass FC410SNM Sounder Output Module

Fireclass 557.180.423FC TM520 Timer Module Non-Addressable

Fireclass FC440AVR Addressable Red Wall Sounder VAD

Fireclass FC445AVR Addressable Weatherproof Red Wall Sounder VAD

Fireclass FC440AVW Addressable White Wall Sounder VAD

Fireclass 576.440.016FC FC440CAVB Addressable Base Sounder VAD BC

Fireclass 576.440.016FC FC440CAVB Addressable Base Sounder VAD BC

Fireclass 576.440.016FC FC440CAVB Addressable Base Sounder VAD BCThe Visual Alarm Device VAD Sounder Beacons are loop powered units that are driven from an addressable controller panel. They are available in ceiling and outdoor wall mounted variants.The ceiling mounted variants provide a base for fitting a fire detector. Alternatively a blanking cap is fitted.All VAD Sounder Beacons have a built-in two port loop short circuit isolator. Settings for tones volume beacon flash and status monitoring are configurable using the control panel.Selectable flash rates are1Hz one flash every second0.5Hz one flash every two secondsKey FeaturesA compact and unobtrusive sounder solutionShorter Light Pulse for faster responseFC445CAV has an outdoor version with a deep surface back box for use with suitable IP-rated glands and cablingPower and data from the loop. No additional wiring or power supplies requiredBuilt-in line isolator15 selectable tones for FC440CAVBRealistic Conventional Bell Tone4 selectable volumes for FC440CAVB2 selectable flash ratesSelect the tone volume and flash rate using panel configuration softwareMounting orientation CeilingIndoor type AOutdoor type B IndoorWeight g 178Housing colour ClearOperating temperature C -25 to 70Storage temperature C -25 to 70Humidity Up to 95 non-condensingEN54-17 isolator YesEN54-3 sounder YesEN54-23 visual alarm YesVibration shock corrosion EMC Complies with EN54 series requirementsIngress protection rating IP21CFlash colour White

GBP 202.74
1

Fireclass 508.033.751FC Prescient III Extinguishing Control Panel

Fireclass 508.033.751FC Prescient III Extinguishing Control Panel

Fireclass 508.033.751FC Prescient III Extinguishing Control PanelThe Prescient III gaseous extinguishant control panel is powerful yet user-friendly and is designed and manufactured to a high standard. The panel features approval to BSEN 12094-12003 BSEN 54-2 and 4 and is designed to BS7273 part 1.The panel has extensive configuration options but is easy to install programme and operate. The removable chassis enables the engineer to first fix an empty cabinet and then fit the chassis at the commissioning stage. This is supported by comprehensive documentation on commissioning operating maintenance and fault finding. In addition there is a comprehensive range of compatible accessories available to meet most customer requirements.Key FeaturesComprehensive facilities for gaseous extinguishing systemsApproval to BSEN 12094-12003 additional optionsApproval to BSEN 54-2 and 4Designed to BS7273-12000Monitored inputs for gas discharged gas low isolation valve closedabnormal gas trapped in manifoldControl inputs for automanual gas hold gas abort1 minute actuator cut off optionMonitored actuatorsolenoid releaseExtensive disablement optionsCommon fire fault relay monitored output facilities1st stage 2nd stage 3rd stage and gas discharged relay monitored output facilitiesReset relay facilitiesIntrinsically safe barrier settingsMetron or solenoid compatibleSingle or double knock operationPre-discharge delay adjustable from 0 to 60 secondsDischarged indication with or without pressure switchInhibit silence alarms until gas dischargedLatching or non latching fault indication optionOption for rapid buzzer pulse when gas imminentSemi-flush bezel and fully-flush cabinet options availableOne man zone and sounder testEasily removable chassis

GBP 671.05
1

Fireclass FC440AVB Addressable Sounder VAD Standard Power

Fireclass FC440AVB Addressable Sounder VAD Standard Power

Fireclass FC440AVB Addressable Sounder VAD Standard PoThe FC440AVB and FC441AVB are addressable sounder bases with a visual alarm device specifically for use with the FireClass addressable detectors. The bases are available as fire alarm sounders with visual alarm device VAD in two power outputs Standard and High.The High-power option provides more coverage for the VAD compared to Standard. Each has an address so they can be monitored and controlled from the fire alarm control panel which is independent of the detector fitted to the base. The power and communications for the sounder VAD and detector are provided by the digital loop. This helps to reduce installation costs as no additional wiring is required.Key FeaturesA compact and discrete solutionVAD approved to EN54-23 with two ranges standard power and high power availableHigh Power option provides a larger VAD coverage volume compared to StandardReflective Sound Monitoring RSMReflective Light Monitoring RLMSelf-testShorter Light Pulse for faster responseOptimise the system design for lowest power requirements and lowest cost installationTriple light sourceOne point of installation for detector sounder and visual indicator with no additional wiringIndependent addressable control of the sounder and beaconBuilt-in line isolatorSelect the tone volume and flash rate using panel configuration software15 selectable tones. Allows users to select the tone with which they are most familiar.Realistic Conventional Bell Tone2 selectable volumes2 selectable flash ratesDifferent tones can be used for fire alarm and class changeVADs and sounders are synchronised over the entire loopA locking pin supplied with the base which prevents the unauthorized removal of the detectorProvides an EN54-23 approved upgrade path for legacy systems

GBP 107.70
1

Fireclass FC441AVB Addressable Sounder VAD Base High Power

Fireclass FC441AVB Addressable Sounder VAD Base High Power

Fireclass FC441AVB Addressable Sounder VAD Base High PowerThe FC440AVB and FC441AVB are addressable sounder bases with a visual alarm device specifically for use with the FireClass addressable detectors. The bases are available as fire alarm sounders with visual alarm device VAD in two power outputs Standard and High. The High power option provides more coverage for the VAD compared to Standard.Each has an address so they can be monitored and controlled from the fire alarm control panel which is independent of the detector fitted to the base. The power and communications for the sounder VAD and detector are provided by the digital loop. This helps to reduce installation costs as no additional wiring is required.Key FeaturesA compact and discrete solutionVAD approved to EN54-23 with two ranges standard power and high power availableHigh Power option provides a larger VAD coverage volume compared to StandardReflective Sound Monitoring RSMReflective Light Monitoring RLMSelf-testShorter Light Pulse for faster responseOptimise the system design for lowest power requirements and lowest cost installationTriple light sourceOne point of installation for detector sounder and visual indicator with no additional wiringIndependent addressable control of the sounder and beaconBuilt-in line isolatorSelect the tone volume and flash rate using panel configuration software15 selectable tones. Allows users to select the tone with which they are most familiar.Realistic Conventional Bell Tone2 selectable volumes2 selectable flash ratesDifferent tones can be used for fire alarm and class changeVADs and sounders are synchronised over the entire loopA locking pin supplied with the base which prevents the unauthorized removal of the detectorProvides an EN54-23 approved upgrade path for legacy systems

GBP 146.15
1

Fireclass 557.200.954FC FC1DS Fully Functional Repeater

Fireclass 557.200.954FC FC1DS Fully Functional Repeater

Fireclass 557.200.954FC FC1DS Fully Functional RepeaterThe FC700 Fireclass range of repeaters include both AC and DC powered models with the option for single or multiple zonal displays. The FC700 FC1DS Fireclass fully functional Repeater is designed for applications where full functionality is required in a compact discrete and architecturally attractive package.FC700 FircClass panels and repeaters feature an advanced TFT colour touchscreen user interface that is ergonomically engineered specifically for fire alarm control. It is designed for operation with or without gloves and provides easy-to-use intuitive and flexible user controls including keyless log-on using RFID tags coded for different access levels.Up to seven FC700 touch screen repeaters can be connected to each FC700 control panel. Each repeater gives full user control and functionality interfacing with the control panel using an Ethernet connection. The FC700 Fireclass repeaters uses a direct network connection local network WiFi wireless or VPN with a maximum distance between the panel and the network point or repeater and network point of 100 m.Key Features8.4 TFT colour touch screen multilingual user interface - architecturally attractive and fully ProgrammableErgonomic Icon Display - Simple to operate user interface eliminates operator errorsTouch sensitive status LEDs provide event summaryInformation - Instant access to detailed event informationContext sensitive help and on screen operator instructions - reduces the need for user trainingUser configurable on screen site maps - No need for additional site plansProgrammable graphic quiescent display - Opportunity for customer brandingComprehensive point management and disable functions - Gives the user full control and reduces service and maintenance effortSelectively view or print from the extensive 10000 event log using dynamic filters Effective event diagnostics to quickly resolve site investigationsKeyless log-on using RFID tags - Identifies and logs user actionsFlush mount kit available

GBP 724.86
1

Fireclass 557.200.955FC FC1D2 Display Only Repeater

Fireclass 557.200.955FC FC1D2 Display Only Repeater

Fireclass 557.200.955FC FC1D2 Display Only RepeaterThe FC700 Fireclass range of repeaters include both AC and DC powered models with the option for single or multiple zonal displays. The FC700 FC1D2 Display Only Repeater offers basic functionality and overview of the system status of the Fireclass fire detection system.FC700 Fireclass panels and repeaters feature an advanced TFT colour touchscreen user interface that is ergonomically engineered specifically for fire alarm control. It is designed for operation with or without gloves and provides easy-to-use intuitive and flexible user controls including keyless log-on using RFID tags coded for different access levels.Up to seven FC700 touch screen repeaters can be connected to each FC700 control panel. Each repeater gives full user control and functionality interfacing with the control panel using an Ethernet connection. The FC700 Fireclass repeaters uses a direct network connection local network WiFi wireless or VPN with a maximum distance between the panel and the network point or repeater and network point of 100 m.Key Features8.4 TFT colour touch screen multilingual user interface - architecturally attractive and fully ProgrammableErgonomic Icon Display - Simple to operate user interface eliminates operator errorsTouch sensitive status LEDs provide event summaryInformation - Instant access to detailed event informationContext sensitive help and on screen operator instructions - reduces the need for user trainingUser configurable on screen site maps - No need for additional site plansProgrammable graphic quiescent display - Opportunity for customer brandingComprehensive point management and disable functions - Gives the user full control and reduces service and maintenance effortSelectively view or print from the extensive 10000 event log using dynamic filters Effective event diagnostics to quickly resolve site investigationsKeyless log-on using RFID tags - Identifies and logs user actionsFlush mount kit available

GBP 672.68
1

Fireclass 576.440.017FC FC445CAV Addressable Wall Sounder VAD BC

Fireclass 576.440.017FC FC445CAV Addressable Wall Sounder VAD BC

Fireclass 576.440.017FC FC445CAV Addressable Wall Sounder VAD BCThe 576.440.017FC is a FC445CAV Addressable Wall Sounder VAD BC.This model is compatible with FC510 and FC520 panels and should be used only with those panels. The panel display will show device type of the previous FC410LPBS and FC430LPBSB.The Visual Alarm Device VAD Sounder Beacons are loop powered units that are driven from an addressable controller panel. They are available in ceiling and outdoor wall mounted variants.The ceiling mounted variants provide a base for fitting a fire detector. Alternatively a blanking cap is fitted.All VAD Sounder Beacons have a built-in two port loop short circuit isolator. Settings for tones volume beacon flash and status monitoring are configurable using the control panel.Selectable flash rates are1Hz one flash every second0.5Hz one flash every two secondsKey FeaturesA compact and unobtrusive sounder solutionShorter Light Pulse for faster responseFC445CAV is outdoor versions with a deep surface back box for use with suitable IP-rated glands and cablingPower and data from the loop. No additional wiring or power supplies requiredBuilt-in line isolator16 selectable tones for FC445CAVRealistic Conventional Bell Tone2 selectable volumes for FC445CAV2 selectable flash ratesSelect the tone volume and flash rate using panel configuration softwareCoverage volume code Open ClassDevices per loop Up to 44Flash rate 0.5 1 HzDimensions WxHxD mm 105x153x 97 with I.P. BackBoxSound output 1m Up to 100dBABody colour RedFlash colour WhiteIP code IP55Approvals EN54-3 23 17Housing material PC-ABSOperating temperature C -25 to 70Storage temperature C -25 to 70Humidity Up to 95 non-condensingPressure Sounder SPL output quoted for 1000 mBarEN54-17 isolator YesEN54-3 sounder YesEN54-23 visual alarm YesBeacon intensity settings 1Vibration shock corrosion EMC Complies with EN54 series requirementsBeacon flash rates 0.5 and 1 Hz

GBP 251.53
1

Fireclass 517.001.301FC MTL7728 Zener Safety Barrier for Conventional Detection Circuits

Fireclass 517.001.301FC MTL7728 Zener Safety Barrier for Conventional Detection Circuits

Fireclass 517.001.301FC MTL7728 Zener Safety Barrier for Conventional Detection CircuitsThe MTL7728 is an intrinsically safe zone-powered Zener-diode barrier for use in conventional fire detection systems for protection within hazardous areas.Each Zone contains two stages of pulse-tested Zener or forward- connected diodes and an infallible terminating resistor. In the event of an electrical fault in the safe area the diodes limit the voltage that can reach the hazardous area and the resistor limits the current. A fuse protects the diodes and the two stages of voltage limitation ensure continued safety if either stage should fail. No active output-current limiting circuits are employed.Model MTL7728 is certified ia for all zones and IIC for all explosive atmospheres.The MTL7700 Series intrinsically safe shunt-diode safety barriers are innovative devices designed to provide exceptionally high packing densities straightforward installation and simplified connection commissioning and maintenance facilities. The MTL7700 Series include secondary replaceable fuses. These are useful where there is the possibility of faults occurring during commissioning which would otherwise blow the barriers internal safety fuses.One secondary replaceable fuse for each barrier channel is provided and is lower in value than the safety related fuse. Fuses are packaged in small mouldings which can be latched in a disconnect position to break the safe and hazardous areas during commissioning maintenance and fault finding thus avoiding the need for additional disconnect terminals.Key FeaturesRemovable colour-coded terminalsBussed power feed to other modulesRelay and solid state switch modulesDual channel variants - 6.3mm per channelProximity detector inputsCompatible terminal numbering and safety descriptionsDimensions 105 x 90 x 12.6mmNumber of Channels 1Supply Voltage 28 V dcSafety Voltage Maximum 26 V dcSafety Current Resistance 300ohmSafety Current Maximum 93mASignal Type AnalogueMinimum Operating Temperature -20CMaximum Operating Temperature 65CHazardous Area Certification ATEXOperating Temperature Range Maximum of 65 C

GBP 77.08
1

Fireclass 557.200.956FC FC8AS 80 Zone AC Repeater

Fireclass 557.200.956FC FC8AS 80 Zone AC Repeater

Fireclass 557.200.956FC FC8AS 80 Zone AC RepeaterThe FC700 FireClass range of repeaters include both AC and DC powered models with the option for single or multiple zonal displays. The FC8AS repeater is designed to match the performance and style of the FC708D 80 zone control panel however it can be used with any FireClass FC700 detection panel.The FC700 FC1DS FireClass fully functional Repeater is designed for applications where full functionality is required in a compact discrete and architecturally attractive package. The FC700 FC1D2 Display Only Repeater offers basic functionality and overview of the system status of the FireClass fire detection system. The optional matching slim-line 40 way and 80-way zonal LED displays are available.FC700 FireClass panels and repeaters feature an advanced TFT colour touchscreen user interface that is ergonomically engineered specifically for fire alarm control. It is designed for operation with or without gloves and provides easy-to-use intuitive and flexible user controls including keyless log-on using RFID tags coded for different access levels.Up to seven FC700 touch screen repeaters can be connected to each FC700 control panel. Each repeater gives full user control and functionality interfacing with the control panel using an Ethernet connection. The FC700 FireClass repeaters uses a direct network connection local network WiFi wireless or VPN with a maximum distance between the panel and the network point or repeater and network point of 100 m.Key Features8.4 TFT colour touch screen multilingual user interface - architecturally attractive and fully programmableErgonomic Icon Display - Simple to operate user interface eliminates operator errorsTouch sensitive status LEDs provide event summaryInformation - Instant access to detailed event informationContext sensitive help and on-screen operator instructions - reduces the need for user trainingUser configurable on-screen site maps - No need for additional site plansProgrammable graphic quiescent display - Opportunity for customer brandingComprehensive point management and disable functions - Gives the user full control and reduces service and maintenance effortSelectively view or print from the extensive 10000 event log using dynamic filters Effective event diagnostics to quickly resolve site investigationsKeyless log-on using RFID tags - Identifies and logs user actionsFlush mount kit available

GBP 1526.54
1