Solo 460 Heat Detector Tester Baffle for Fike Detectors 15-0239 Solo 460 Heat Detector Tester Baffle for Fike Detectors 15-0239Due to the uniquely shaped detector chambers on Fike detectors the manufacturers developed a baffle to aid testing. the baffle is designed for the Solo 460 heat detector tester head unit and changes the direction of the direct heat flow to ensure a complete and effective test when testing Fike detectors. The baffle is inserted at the top of the Solo 460 as illustrated in the picture above.Please note Baffle only for use with Fike Detectors please remove when testing other detectors allowing for the direct heat flow to return to its standard format. GBP 11.76 1
Fike 204-0003 Twinflex Multipoint ASD Detector Fike 204-0003 Twinflex Multipoint ASD DetectorThe Multipoint and ASD detectors have set new standards in detector technology. The TWINFLEX Multipoint head is a 2-wire device used with the TWINFLEX and TWINFLEX Pro systems whereas the addressable ASD detector is used on the Sita200plus Duonet and Quadnet systems. Using microprocessor control these devices offer the installer a full range of detection capabilities with audible and visual warning in one compact device for full DDA compliance.The detectors can be matched to the environment in which they are installed and changed any time during the lifetime of the installation. The mode of detection required can be changed simply by configuring the DIL switch in the detector electronics module configurable via commissioning software on addressable systems. All modes are compliant with European detector type specifications.The TWINFLEX two-wire Multipoint detector can be set to any one of 3 smoke modes 3 heat modes as well as a Combined Mode Smoke 2 and Heat 2 where a smoke or heat source can trigger a fire decision - see opposite. The end user is given optimum fire protection even if the installer is unsure of the use of the particular area where the detector is sited. All TWINFLEX products including the Multipoint detector feature an End of Line switch negating the need for end-of-line resistors.The Multipoint and ASD detectors have the unique benefit of an optional full specification integral sounder where 90dBA output can be achieved. The two-wire Multipoint detector can be set to 3 different sound patterns as well as switched off with 2 sound output levels. The addressable ASD detector has 7 different sound patterns and 3 volume settings as well as the option of a combined strobe.Key FeaturesIntegral Strobe - The Multipoint ASD can be ordered with an optional integral strobe allowing the 2-wire installation of an advanced smokeheat detector sounder and strobe in a single cost-saving device.Base LED - When the detector head is removed a base mounted LED flashes allowing users to easily identify which head is missing even from considerable distance e.g. in a high-ceiling building.Head Removal Tool - The Multipoint ASD detector removal tool fits the Solo Detector Tester pole for easy testing and maintenance at height.Optical Chamber - The Multipoint ASD detector incorporates a new advanced optical chamber for enhanced smoke detection.Modes of DetectionSmoke 1 Used where ionisation detectors are normally fitted especially when there are high ceilings or a risk of free burning fires chemical stores etc. or fires that need to be detected extremely quickly.Smoke 2Used where optical detectors are normally fitted when there is a risk of a smouldering fire and for escape routes.Smoke 3Designed for use in areas that are prone to nuisance alarms. The reduced sensitivity linked with a time delay feature means that a higher concentration of smoke needs to be present for a constant time period before a fire decision is made. For example this setting is ideal for hotel bedrooms with en-suite shower rooms. The installer or service engineer can change the setting from smoke 2 to smoke 3 if nuisance alarms are a problem whilst still offering optimum protection of a smoke detection setting.Heat 1 Rate of RiseUsed where a standard rate of rise detector would normally be used.Heat 2 Standard Fixed Temperature - 58C approx. Used where a standard fixed temperature heat detector would normally be fitted suitable for kitchens etc.Heat 3 High Fixed Temperature - 90C approx. Used where a high fixed temperature heat detector would normally be fitted. Suitable for commercial kitchens boiler rooms etc. GBP 32.12 1
Fike 204-0003-B Twinflex Multipoint ASD Detector - Black Fike 204-0003-B Twinflex Multipoint ASD Detector - BlackThe Multipoint and ASD detectors have set new standards in detector technology. The TWINFLEX Multipoint head is a 2-wire device used with the TWINFLEX and TWINFLEX Pro systems whereas the addressable ASD detector is used on the Sita200plus Duonet and Quadnet systems. Using microprocessor control these devices offer the installer a full range of detection capabilities with audible and visual warning in one compact device for full DDA compliance.The detectors can be matched to the environment in which they are installed and changed any time during the lifetime of the installation. The mode of detection required can be changed simply by configuring the DIL switch in the detector electronics module configurable via commissioning software on addressable systems. All modes are compliant with European detector type specifications.The TWINFLEX two-wire Multipoint detector can be set to any one of 3 smoke modes 3 heat modes as well as a Combined Mode Smoke 2 and Heat 2 where a smoke or heat source can trigger a fire decision - see opposite. The end user is given optimum fire protection even if the installer is unsure of the use of the particular area where the detector is sited. All TWINFLEX products including the Multipoint detector feature an End of Line switch negating the need for end-of-line resistors.The Multipoint and ASD detectors have the unique benefit of an optional full specification integral sounder where 90dBA output can be achieved. The two-wire Multipoint detector can be set to 3 different sound patterns as well as switched off with 2 sound output levels. The addressable ASD detector has 7 different sound patterns and 3 volume settings as well as the option of a combined strobe.Key FeaturesIntegral Strobe - The Multipoint ASD can be ordered with an optional integral strobe allowing the 2-wire installation of an advanced smokeheat detector sounder and strobe in a single cost-saving device.Base LED - When the detector head is removed a base mounted LED flashes allowing users to easily identify which head is missing even from considerable distance e.g. in a high-ceiling building.Head Removal Tool - The Multipoint ASD detector removal tool fits the Solo Detector Tester pole for easy testing and maintenance at height.Optical Chamber - The Multipoint ASD detector incorporates a new advanced optical chamber for enhanced smoke detection.Colour- BlackModes of DetectionSmoke 1 Used where ionisation detectors are normally fitted especially when there are high ceilings or a risk of free burning fires chemical stores etc. or fires that need to be detected extremely quickly.Smoke 2Used where optical detectors are normally fitted when there is a risk of a smouldering fire and for escape routes.Smoke 3Designed for use in areas that are prone to nuisance alarms. The reduced sensitivity linked with a time delay feature means that a higher concentration of smoke needs to be present for a constant time period before a fire decision is made. For example this setting is ideal for hotel bedrooms with en-suite shower rooms. The installer or service engineer can change the setting from smoke 2 to smoke 3 if nuisance alarms are a problem whilst still offering optimum protection of a smoke detection setting.Heat 1 Rate of RiseUsed where a standard rate of rise detector would normally be used.Heat 2 Standard Fixed Temperature - 58C approx. Used where a standard fixed temperature heat detector would normally be fitted suitable for kitchens etc.Heat 3 High Fixed Temperature - 90C approx. Used where a high fixed temperature heat detector would normally be fitted. Suitable for commercial kitchens boiler rooms etc. GBP 46.84 1
Fike Twinflex Multipoint ASD Detector with Sounder Strobe - 204-0012 Fike Twinflex Multipoint ASD Detector with Sounder Strobe - 204-0012The Multipoint and ASD detectors have set new standards in detector technology. The TWINFLEX Multipoint head is a 2-wire device used with the TWINFLEX and TWINFLEX Pro systems whereas the addressable ASD detector is used on the Sita200plus Duonet and Quadnet systems. Using microprocessor control these devices offer the installer a full range of detection capabilities with audible and visual warning in one compact device for full DDA compliance. The detectors can be matched to the environment in which they are installed and changed any time during the lifetime of the installation. The mode of detection required can be changed simply by configuring the DIL switch in the detector electronics module configurable via commissioning software on addressable systems. All modes are compliant with European detector type specifications.The addressable ASD detector offers multiple choices for detection set to a single mode or a combination for a choice of up to 15 different settings. Programmable via a PC or at the panel Quadnet and Duonet only and also has an in-built loop isolator as well as IO for local control and switching.The TWINFLEX two-wire Multipoint detector can be set to any one of 3 smoke modes 3 heat modes as well as a Combined Mode Smoke 2 and Heat 2 where a smoke or heat source can trigger a fire decision - see opposite. The end user is given optimum fire protection even if the installer is unsure of the use of the particular area where the detector is sited. All TWINFLEX products including the Multipoint detector feature an End of Line switch negating the need for end-of-line resistors.The Multipoint and ASD detectors have the unique benefit of an optional full specification integral sounder where 90dBA output can be achieved. The two-wire Multipoint detector can be set to 3 different sound patterns as well as switched off with 2 sound output levels. The addressable ASD detector has 7 different sound patterns and 3 volume settings as well as the option of a combined strobe.Key FeaturesIntegral Strobe - The Multipoint ASD can be ordered with an optional integral strobe allowing the 2-wire installation of an advanced smokeheat detector sounder and strobe in a single cost-saving device.Base LED - When the detector head is removed a base mounted LED flashes allowing users to easily identify which head is missing even from considerable distance e.g. in a high-ceiling building.Head Removal Tool - The Multipoint ASD detector removal tool fits the Solo Detector Tester pole for easy testing and maintenance at height.Optical Chamber - The Multipoint ASD detector incorporates a new advanced optical chamber for enhanced smoke detection.Modes of DetectionSmoke 1 Used where ionisation detectors are normally fitted especially when there are high ceilings or a risk of free burning fires chemical stores etc. or fires that need to be detected extremely quickly.Smoke 2Used where optical detectors are normally fitted when there is a risk of a smouldering fire and for escape routes.Smoke 3Designed for use in areas that are prone to nuisance alarms. The reduced sensitivity linked with a time delay feature means that a higher concentration of smoke needs to be present for a constant time period before a fire decision is made. For example this setting is ideal for hotel bedrooms with en-suite shower rooms. The installer or service engineer can change the setting from smoke 2 to smoke 3 if nuisance alarms are a problem whilst still offering optimum protection of a smoke detection setting.Heat 1 Rate of RiseUsed where a standard rate of rise detector would normally be used.Heat 2 Standard Fixed Temperature - 58C approx. Used where a standard fixed temperature heat detector would normally be fitted suitable for kitchens etc.Heat 3 High Fixed Temperature - 90C approx. Used where a high fixed temperature heat detector would normally be fitted. Suitable for commercial kitchens boiler rooms etc. GBP 60.25 1