14 results (0,15240 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

Fireray 5000 Single Detector Pack 100m

Fireray 5000 Auto-Aligning Optical Beam Smoke Detector 50m

Fireray 5000 Single Detector Pack 50m

Fireray 5000 Auto-Aligning Optical Beam Smoke Detector 100m

Fireray 3000 End to End Infrared Optical Beam Detector

Fireray 3000 Transmitter amp Receiver

FFE Fireray 6010-300 Reflective Beam Detector UL

Fireray 3000-007 Fireray 3000 Controller

Fireray 3000-007 Fireray 3000 Controller

Fireray 3000-007 Fireray 3000 ControllerThe Fireray 3000 is ideal for applications where line of sight for the IR infra-red detection path is narrow and where the building structure uses reflective surfaces. It has also been designed to be aesthetically pleasing and thus can equally suit modern architectural buildings as well as heritage sites particularly where ornate ceilings exist.The Fireray 3000 optical beam smoke detectors together with a battery backed power supply can be connected to a zone of a conventional fire alarm control panel or interfaced to an analogue-addressable system via an addressable input module.The Fireray 3000 has been designed so that it can be installed by one operator with its laser assisted alignment methods combined with easy-to-use alignment LEDs offering a visual feedback. Integrated laser alignment aid can be activated at the controller or at the Receiver head.Key FeaturesAllows for 2 Detectors per System ControllerRange 5 to 120 metres configurable per set of DetectorsIntegral Laser Alignment in Receiver2-wire Interface between Controller and ReceiverSeparate Fire and Fault Relays per DetectorLow Level Controller with LCD displayProgrammable Sensitivity and FireFault delayAutomatic Gain Control AGC for drift compensationFirst Fix concept for Transmitter Receiver and ControllerMultiple cable gland knockouts for ease of wiringTransmitter can be powered from ControllerPatented Light Cancellation Technology LCT cancels unwanted light including sunlight sodium lamps and fluorescent lighting

GBP 1044.00
1

FFE Fireray 5000-031 Fireray 5000 Detector ULFM

FFE Fireray 5000-031 Fireray 5000 Detector ULFM

FFE Fireray 5000-031 Fireray 5000 Detector ULFMA spare Fireray 5000 detector.The Fireray 5000 System is an auto-aligning self-correcting infrared reflective beam smoke detector. Up to 2 detector heads can report to a single ground level controller. In addition each system controller houses two pairs of fire and trouble relays one per detector. Once the detector head is installed using the easyfit mounting system an integral LASER can be activated. This allows the reflective prism to be located quickly and with confidence.The Auto-Align function ensures proper alignment and maximum signal during the beam installation. AutoOptimise automatically steers and maintains the beam in the optimum position for reliable performance. The signal generated in the transmitter element and reflected by the prism back to the receiver element is analyzed for the presence of smoke. The internal microprocessor determines an alarm condition when a predetermined level obscuration is reached.The system is designed to be mounted so the beam will project between 19 0.5m and 24 0.6m below the ceiling. Lateral detection may be up to 30ft. 9.144m on either side of the beam providing a maximum total coverage area of up to 19800 square feet 60ft. x 330ft. or 18.29m x 100m. For installations complying with UL268NFPA72 the maximum distance of Detector and Reflector from the ceiling must be 10 of the distance between floor and ceiling.Key FeaturesUp to 2 Detector Heads reporting to One Ground Level ControllerRange of 26.2 ft to 328 ft 8 m to 100 mLong range prism kit extends range from 160ft 50m to 330ft 100mBuilt in Laser assisted prism mountingAuto-Alignment 2 to 4 minutes per headAutOptimise Auto-Correction due to building shiftBuilt-in electronic ULULCFM obscuration-acceptance fire testContamination compensationSeparate Trouble and Alarm relays for each of the 2 channelsPassword protected settingsLow current draw 5 to 8.5mABuilt-in 12M-20 conduit knock-outs on the system controllerProgrammable alarm thresholds 10 60 in 1 incrementsProgrammable Fault and Alarm delay 2-30 Seconds

GBP 948.30
1

FFE Fireray 5000-048 Fireray 5000 Detector NF

FFE Fireray 5000-048 Fireray 5000 Detector NF

FFE Fireray 5000-048 Fireray 5000 Detector NFA spare Fireray 5000 detector NF.The Fireray 5000 System is an auto-aligning self-correcting infrared reflective beam smoke detector. Up to 2 detector heads can report to a single ground level controller. In addition each system controller houses two pairs of fire and trouble relays one per detector. Once the detector head is installed using the easyfit mounting system an integral LASER can be activated. This allows the reflective prism to be located quickly and with confidence.The Auto-Align function ensures proper alignment and maximum signal during the beam installation. AutoOptimise automatically steers and maintains the beam in the optimum position for reliable performance. The signal generated in the transmitter element and reflected by the prism back to the receiver element is analyzed for the presence of smoke. The internal microprocessor determines an alarm condition when a predetermined level obscuration is reached.The system is designed to be mounted so the beam will project between 19 0.5m and 24 0.6m below the ceiling. Lateral detection may be up to 30ft. 9.144m on either side of the beam providing a maximum total coverage area of up to 19800 square feet 60ft. x 330ft. or 18.29m x 100m. For installations complying with UL268NFPA72 the maximum distance of Detector and Reflector from the ceiling must be 10 of the distance between floor and ceiling.Key FeaturesUp to 2 Detector Heads reporting to One Ground Level ControllerRange of 26.2 ft to 328 ft 8 m to 100 mLong range prism kit extends range from 160ft 50m to 330ft 100mBuilt in Laser assisted prism mountingAuto-Alignment 2 to 4 minutes per headAutOptimise Auto-Correction due to building shiftBuilt-in electronic ULULCFM obscuration-acceptance fire testContamination compensationSeparate Trouble and Alarm relays for each of the 2 channelsPassword protected settingsLow current draw 5 to 8.5mABuilt-in 12M-20 conduit knock-outs on the system controllerProgrammable alarm thresholds 10 60 in 1 incrementsProgrammable Fault and Alarm delay 2-30 Seconds

GBP 948.30
1