26 results (0,14319 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

Cooper CIO351 3 Channel Input Output Unit MIO324 FXN510

Cooper Menvier CIO351SST Addressable 3 Channel IO Unit Triple Address

Cooper CIO351S 3 Channel Input Output Unit resets on silence alarms MIO324S FXN510S

Cooper EOLM-3 End of Line Module Bi-Wire Circuits Box of 8

Cooper Bi-Wire Wall Sounder EF009

Cooper Bi-Wire Wall Sounder Weatherproof VAD Beacon EF009SBWP

Cooper Bi-Wire Wall Sounder VAD Beacon EF009SB

Cooper Bi-Wire Weatherproof Wall Sounder EF009WP

Cooper Bi-Wire Detector 5 Detection Modes EFBW5IN1DET

Cooper Bi-Wire Conventional Repeater Panel EFBWCV-REPEATER

Cooper CF800PROG Intelligent Addressable Device Programmer

Cooper Bi-Wire Base Sounder EF5021BWS

Cooper Bi-Wire Base Sounder VAD Beacon EF5021BWSB

Cooper Menvier EF-CS6-130-ENP 130mm 6W Ceiling Loudspeaker EN54 PFD

Cooper Menvier EF-CS6-165-ENP 165mm 6W Ceiling Loudspeaker EN54 PFD

Cooper CAH330 Intelligent Addressable Multi-Mode Heat Sensor MAH830 FXN725 400003FIRE-0003X

Cooper CASB393 Open Class Wall Sounder VAD With Isolator Red Body White Flash FXN559LPS MASB880

Cooper CASB393-WP Wall Sounder Weatherproof VAD with Isolator White Flash FXN559LPSWP MASB880WP

Cooper EC0232 Lon to RS232 Adapter

Cooper Menvier 400003FIRE-0003X Addressable Multi-Mode Heat Sensor

Cooper Menvier 400003FIRE-0003X Addressable Multi-Mode Heat Sensor

Cooper Menvier 400003FIRE-0003X Addressable Multi-Mode HeatSensorThis range of intelligent addressable sensors have been specificallydesigned to operate with Eatons intelligent addressable fire systems.All sensors are third party approved to the relevant sectionof EN54 part 7 for smoke detectors part 5 for heat detectors and part 17 forshort circuit isolators. The optical sensor CAP320 is suitable for most applicationsgiving the fastest response to slow burning or smouldering fires which giverise to large visible smoke particles.The photo-thermal sensor CAPT340 will respond quickly tofast clean burning fires yet maintain the advantage of optical sensors whendetecting smouldering fires The thermal enhancement of this sensor allows ahigher alarm threshold which provides a greater rejection of false alarms. Thesensor will also raise an alarm at temperatures exceeding 60C.The CAPT340 has daynight modes available programmable fromthe site installer software. The day mode uses the heat aspect of the sensorfor areas which may have smoky environments during for example working hours.The night mode uses a combination of A2S and smoke detection. If notprogrammed the sensor defaults to dual mode.The heat sensor CAH330 can be set to one of 3 modes 77C 92C and rate of rise. These sensors are designed to be used in environmentswhere the ambient conditions might cause false alarms if smoke detection wereto be used for example where there is a high level of dust fumes steam orsmoke under normal conditions.Key FeaturesSoft addressedIntegral short circuit isolatorSingle addressWide range of sensor types360 visibility LED using lightpipe technologyDrift compensation

GBP 34.94
1

Cooper Menvier 400002FIRE-0002X Addressable Optical Smoke Sensor

Cooper Menvier 400002FIRE-0002X Addressable Optical Smoke Sensor

Cooper Menvier 400002FIRE-0002X Addressable Optical SmokeSensorThis range of intelligent addressable sensors have been specificallydesigned to operate with Eatons intelligent addressable fire systems.All sensors are third party approved to the relevant sectionof EN54 part 7 for smoke detectors part 5 for heat detectors and part 17 forshort circuit isolators. The optical sensor CAP320 is suitable for most applicationsgiving the fastest response to slow burning or smouldering fires which giverise to large visible smoke particles.The photo-thermal sensor CAPT340 will respond quickly tofast clean burning fires yet maintain the advantage of optical sensors whendetecting smouldering fires The thermal enhancement of this sensor allows ahigher alarm threshold which provides a greater rejection of false alarms. Thesensor will also raise an alarm at temperatures exceeding 60C.The CAPT340 has daynight modes available programmable fromthe site installer software. The day mode uses the heat aspect of the sensorfor areas which may have smoky environments during for example working hours.The night mode uses a combination of A2S and smoke detection. If notprogrammed the sensor defaults to dual mode.The heat sensor CAH330 can be set to one of 3 modes 77C 92C and rate of rise. These sensors are designed to be used in environmentswhere the ambient conditions might cause false alarms if smoke detection wereto be used for example where there is a high level of dust fumes steam orsmoke under normal conditions.Key FeaturesSoft addressedIntegral short circuit isolatorSingle addressWide range of sensor types360 visibility LED using lightpipe technologyDrift compensationAesthetically pleasingQuick and simple to installSingle multi-mode heat sensorWide viewing angle for increased LED visibilityCommon mounting basePositive lock indicationDiscreet design for incorporation into any dcorEasy to maintainservice

GBP 34.98
1

Cooper Menvier 400004FIRE-0004X Addressable Photo-Thermal Sensor

Cooper Menvier 400004FIRE-0004X Addressable Photo-Thermal Sensor

Cooper Menvier 400004FIRE-0004X Addressable Photo-ThermalSensor This range of intelligent addressable sensors have been specificallydesigned to operate with Eatons intelligent addressable fire systems.All sensors are third party approved to the relevant sectionof EN54 part 7 for smoke detectors part 5 for heat detectors and part 17 forshort circuit isolators. The optical sensor CAP320 is suitable for most applicationsgiving the fastest response to slow burning or smouldering fires which giverise to large visible smoke particles.The photo-thermal sensor CAPT340 will respond quickly tofast clean burning fires yet maintain the advantage of optical sensors whendetecting smouldering fires The thermal enhancement of this sensor allows ahigher alarm threshold which provides a greater rejection of false alarms. Thesensor will also raise an alarm at temperatures exceeding 60C.The CAPT340 has daynight modes available programmable fromthe site installer software. The day mode uses the heat aspect of the sensorfor areas which may have smoky environments during for example working hours.The night mode uses a combination of A2S and smoke detection. If notprogrammed the sensor defaults to dual mode.The heat sensor CAH330 can be set to one of 3 modes 77C 92C and rate of rise. These sensors are designed to be used in environmentswhere the ambient conditions might cause false alarms if smoke detection wereto be used for example where there is a high level of dust fumes steam orsmoke under normal conditions.Key FeaturesSoft addressedIntegral short circuit isolatorSingle addressWide range of sensor types360 visibility LED using lightpipe technologyDrift compensationAesthetically pleasingQuick and simple to installSingle multi-mode heat sensorWide viewing angle for increased LED visibilityCommon mounting basePositive lock indicationDiscreet design for incorporation into any dcorEasy to maintainservice

GBP 42.90