Cooper CIO351 3 Channel Input Output Unit MIO324 FXN510 Cooper CIO351 3 Channel Input Output Unit MIO324 FXN510An extensive range of interfaces are available to support the Cooper range of control panels providing solutions for most design requirements.The 3 channel IO unit CIO351 enables simple interfacing between the fire system and other equipment such as nurse call systems or access control systems. The inputs are fully monitored for open and short circuits.Three models of the 3 channel IO unit are availableCIO351 - resets on resetCIO351S - resets on silence alarmsCIO351T -resets on reset - recognised as 3 addressesKey FeaturesSoft addressedIntegral short circuit isolator3 separate inputs and 3 separate outputsInputs monitored for open and short circuitsBenefitsQuick and simple to installNo hard addressing required Plug and playUnit takes 3 inputs and 3 outputsOnly 1 address required to monitor and control saving on equipment and installation main unit GBP 129.73 1
Cooper Menvier CIO351SST Addressable 3 Channel IO Unit Triple Address Cooper Menvier CIO351SST Addressable 3 Channel IO Unit Triple AddressAn extensive range of interfaces are available to support the Cooper range of control panels providing solutions for most design requirements.The 3 channel IO unit CIO351 enables simple interfacing between the fire system and other equipment such as nurse call systems or access control systems.The inputs are fully monitored for open and short circuits.Two models of the 3 channel IO unit are available CIO351 - resets on reset CIO351S - resets on silence alarms CIO351SST - on reset recognised as 3 addressesKey Features Soft addressedIntegral short circuit isolator3 seperate inputs and 3 seperate outputsInputs monitored for open and short circuitsBenefits Quick and simple to installNo hard addressing required Plug and playUnit takes 3 inputs and 3 outputs - Only 1 address required to monitor and control saving on equipment and installation main unit GBP 167.03 1
Cooper ULBU 3 Position Mini Module Enclosure Cooper ULBU 3 Position Mini Module Enclosure3 Position Mini Module Enclosure supplied without micro units GBP 70.08 1
Cooper CIO351S 3 Channel Input Output Unit resets on silence alarms MIO324S FXN510S Cooper CIO351S 3 Channel Input Output Unit resets on silence alarms MIO324S FXN510SAn extensive range of interfaces are available to support the Cooper range of control panels providing solutions for most design requirements.The 3 channel IO unit CIO351 enables simple interfacing between the fire system and other equipment such as nurse call systems or access control systems. The inputs are fully monitored for open and short circuits.Three models of the 3 channel IO unit are availableCIO351 - resets on resetCIO351S - resets on silence alarmsCIO351T -resets on reset - recognised as 3 addressesKey FeaturesSoft addressedIntegral short circuit isolator3 separate inputs and 3 separate outputsInputs monitored for open and short circuitsBenefitsQuick and simple to installNo hard addressing required Plug and playUnit takes 3 inputs and 3 outputs- Only 1 address required to monitor and control saving on equipment and installation main unit GBP 169.63 1
Cooper EOLM-3 End of Line Module Bi-Wire Circuits Box of 8 Cooper EOLM-3 End of Line Module Bi-Wire Circuits Box of 8Each Zone on the panel that is configured for BiWire mode must have the intelligent end of line module EOLM-3 fitted to continually monitor each zone for the presence of fault conditions such as detector head removal open or short circuit and for end of line failures even when in a Fire condition.For new installations any Zone on the panel that is configured for Conventional mode can use the intelligent end of line module EOLM-3 to terminate the zone but the panel will be limited to only detecting the presence of open or short circuit conditions to make it backward compatible with the EOLM-1. All detector head removals will be seen as an open circuit condition. The EOLM-3 module can be placed into the base of the last manual call point or detector base. GBP 44.06 1
Cooper Bi-Wire Wall Sounder EF009 Cooper Bi-Wire Wall Sounder EF009The BiWire wall sounder and wall sounder VAD offers low current consumption and high sound output. The BiWire range has been designed to meet the European standards for EN54-3 for the sounder and EN54-23 for the beacon VAD. It is offered in two variants sounder only or a combined unit of sounder VAD.Key FeaturesCertified to EN54-3 and EN54-23High sound output and durable designWeatherproof optionCertified for Fire useIdeal for high noise environmentsSuitable for open areas as well as outdoor useEasy to maintain and service GBP 30.84 1
Cooper Menvier EF-DA200T Replacement Amplifier Card Cooper Menvier EF-DA200T Replacement Amplifier CardThe EF-DA200T is a replacement or spare Amplifier Card designed for use with the DAU500 panel.Key Features1 x 2 channel active amplifierProvides 2 x 100W per channelMax 3 x EF-DA200T per DAU500 panel GBP 862.51 1
Cooper Bi-Wire Wall Sounder Weatherproof VAD Beacon EF009SBWP Cooper Bi-Wire Wall Sounder Weatherproof VAD Beacon EF009SBWPThe BiWire wall sounder and wall sounder VAD offers low current consumption and high sound output. The BiWire range has been designed to meet the European standards for EN54-3 for the sounder and EN54-23 for the beacon VAD. It is offered in two variants sounder only or a combined unit of sounder VAD.Key FeaturesCertified to EN54-3 and EN54-23High sound output and durable designWeatherproof optionCertified for Fire useIdeal for high noise environmentsSuitable for open areas as well as outdoor useEasy to maintain and servicePlease Note This product is not compatible with the older Cooper Bi-Wire Range. GBP 43.78 1
Cooper Bi-Wire Wall Sounder VAD Beacon EF009SB Cooper Bi-Wire Wall Sounder VAD Beacon EF009SBThe BiWire wall sounder and wall sounder VAD offers low current consumption and high sound output. The BiWire range has been designed to meet the European standards for EN54-3 for the sounder and EN54-23 for the beacon VAD. It is offered in two variants sounder only or a combined unit of sounder VADKey FeaturesCertified to EN54-3 and EN54-23High sound output and durable designWeatherproof optionCertified for Fire useIdeal for high noise environmentsSuitable for open areas as well as outdoor useEasy to maintain and servicePlease Note This product is not compatible with the older Cooper Bi-Wire range. GBP 40.21 1
Cooper Bi-Wire Weatherproof Wall Sounder EF009WP Cooper Bi-Wire Weatherproof Wall Sounder EF009WPThe BiWire wall sounder and wall sounder VAD offers low current consumption and high sound output. The BiWire range has been designed to meet the European standards for EN54-3 for the sounder and EN54-23 for the beacon VAD. It is offered in two variants sounder only or a combined unit of sounder VAD.Key FeaturesCertified to EN54-3 and EN54-23High sound output and durable designWeatherproof optionCertified for Fire useIdeal for high noise environmentsSuitable for open areas as well as outdoor useEasy to maintain and servicePlease Note This product is not compatible with the old Cooper Bi-Wire range. GBP 37.84 1
Cooper Menvier EF-DAU500-RS422 Programming Lead Cooper Menvier EF-DAU500-RS422 Programming LeadThe EF-DAU500-RS422 is a RS422 serial L-NET adapter programming lead which has been designed for use with the DAU500 Pava System.Key FeaturesThe programming lead is supplied withGUI driverUSB to CAT5 L-NET interface moduleUSB cable 3 metresCrossed CAT5e cable 1 metre GBP 388.14 1
Cooper Bi-Wire Detector 5 Detection Modes EFBW5IN1DET Cooper Bi-Wire Detector 5 Detection Modes EFBW5IN1DETThe BiWire detector can be configured to one of 5 settings including 3 heat detector modes helping to prevent false alarms in areas with known high levels of dust fumes steam or smoke.DIL switch Mode Selection Optical Smoke 15m Range Multi-criteria opto-thermal 10.6m Range and 3 Thermistor base heat detection 10.6m Range Rate of Rise A2R characteristic60C Fixed medium temperature BS medium temperature77C Fixed high temperature CS high temperature92C.Key FeaturesDIL-switch mode selectionNon-latching mode for HMO useSchottky diode base optionRemote LED capability360 indicator LED light pipe technologyVersatile product allows for multiple applicationsHelps to prevent false alarms through choice of modesPlease Note This product is not compatible with the older Cooper Bi-Wire system. GBP 20.00 1
Cooper Bi-Wire Conventional Repeater Panel EFBWCV-REPEATER Cooper Bi-Wire Conventional Repeater Panel EFBWCV-REPEATEREatons new BiWire and Conventional repeater panel is compatible with our 2 zone 4 zone and 8 zone BiWire-Ultra EFBWxZONE BiWire-Flexi EFBWxZFLEXI and latest release of conventional panels EFCV8Z. The EFBWCV repeater panel can be daisy-chained up to 3 panels per control panels.It can repeat information from any zone of the panel it is cabled to. With an integral power supply the only wiring required for the repeater panel is the mains input to the power supply unit and the data cable between the fire control panel and each repeater panel.Key FeaturesCan be used with 2 4 and 8 zone control panelsInternal Power supplySimple unit cablingUp to 3 repeaters per control panelSame modern enclosure as control panelsRepeater panel not out of place in public areas GBP 201.05 1
Cooper CF800PROG Intelligent Addressable Device Programmer Cooper CF800PROG Intelligent Addressable Device ProgrammerSuitable for use with current range of devices the addressable device programmer CF800PROG is a versatile tool to aid the installation commissioning maintenance and servicing of current intelligent addressable devices and fire systems.This unit is light robust and easy to operate using a user friendly menu structure on 2 x 40 character LCD display. It is powered from a single PP3 size heavy duty battery or an external supply. This addressable device programmer has a built in addressable base as well as two external terminals for use with all other current addressable ancillary devices.Key FeaturesReads addressesWrites addressesReads analogue valuesTests devicesDeletes addressesProgrammes the 3 heat settingsBenefitsSimple re-programming of devicesPortable no power supply required GBP 588.85 1
Cooper Bi-Wire Base Sounder EF5021BWS Cooper Bi-Wire Base Sounder EF5021BWSThe BiWire base sounder and base sounder VAD can be used either with a sensor or as a standalone device. The base sounders are approved to EN54-23 and are compatible with the BiWire 5 in 1 detector as part of Eatons BiWire fire system. The base sounder and base sounder VAD both incorporate a sensor mounting base a sensor can be fitted directly to the base or alternatively an optional cover plate can be used to provide a dedicated discreetKey FeaturesStandalone deviceAvailable in both sounder only and sounder VADCertified to EN54-3 EN54-23Standalone base sounder or base sounder VAD offers the flexibility of use with or without the detectorCover plate optionalFirst fix base offers a compact design and reduces time of installation of the base with the detectorEasy to maintain and service GBP 25.96 1
Cooper Bi-Wire Base Sounder VAD Beacon EF5021BWSB Cooper Bi-Wire Base Sounder VAD Beacon EF5021BWSBThe BiWire base sounder and base sounder VAD can be used either with a sensor or as a standalone device. The base sounders are approved to EN54-23 and are compatible with the BiWire 5 in 1 detector as part of Eatons BiWire Ultra fire system. The base sounder and base sounder VAD both incorporate a sensor mounting base a sensor can be fitted directly to the base or alternatively an optional cover plate can be used to provide a dedicated discreetKey FeaturesStandalone deviceAvailable in both sounder only and sounder VADCertified to EN54-3 EN54-23Standalone base sounder or base sounder VAD offers the flexibility of use with or without the detectorCover plate optionalFirst fix base offers a compact design and reduces time of installation of the base with the detectorEasy to maintain and service GBP 38.76 1
Cooper Menvier EF-CS6-130-ENP 130mm 6W Ceiling Loudspeaker EN54 PFD Cooper Menvier EF-CS6-130-ENP 130mm 6W Ceiling Loudspeaker EN54 PFDEN54 certified 6 W flush mount ceiling loudspeaker provides excellent sound quality for speech and background music. The speaker is fitted with a 100 V70 V transformer which has three power adjustment tappings.This modern speaker has a powder coated metal chassis and grill that provides long term resistance to corrosion.The rear of the speaker is protected by an antistatic shock resistant plastic housing.The flat construction allows a low mounting depth of only 70 mm. Quick and easy ceiling mounting is provided using spring clamps suitable for ceiling thickness of 3 mm to 45 mm. Perfect for areas where the installation depth is limited.Please note Because of the many different types of ceiling materials and ceiling strengths it should be ensured that the ceiling strength is suitable for the weight of the speaker.Key FeaturesEN54-24 certifiedAntistatic shock resistant housingExcellent sound qualityQuick mount easy installation100V70V line transformer GBP 21.82 1
Cooper Menvier EF-CS6-165-ENP 165mm 6W Ceiling Loudspeaker EN54 PFD Cooper Menvier EF-CS6-165-ENP 165mm 6W Ceiling Loudspeaker EN54 PFDEN54 certified 6 W flush mount ceiling loudspeaker provides excellent sound quality for speech and background music. The speaker is fitted with a 100 V70 V transformer which has three power adjustment tappings.This modern speaker has a powder coated metal chassis and grill that provides long term resistance to corrosion.The rear of the speaker is protected by an antistatic shock resistant plastic housing.The flat construction allows a low mounting depth of only 70 mm. Quick and easy ceiling mounting is provided using spring clamps suitable for ceiling thickness of 3 mm to 45 mm. Perfect for areas where the installation depth is limited.Please note Because of the many different types of ceiling materials and ceiling strengths it should be ensured that the ceiling strength is suitable for the weight of the speaker.Key FeaturesEN54-24 certifiedAntistatic shock resistant housingExcellent sound qualityQuick mount easy installation100V70V line transformer GBP 24.83 1
Cooper CAH330 Intelligent Addressable Multi-Mode Heat Sensor MAH830 FXN725 400003FIRE-0003X Cooper CAH330 Intelligent Addressable Multi-Mode Heat Sensor MAH830 FXN725 400003FIRE-0003XThese ranges of intelligent addressable sensors have been specifically designed to operate with Cooper intelligent addressable fire systems.All sensors are third party approved to the relevant section of EN54 part 7 for smoke detectors part 5 for heat detectors.The heat sensor CAH330 can be set to one of 3 modes 77C 92C and rate of rise. These sensors are designed to be used in environments where the ambient conditions might cause false alarms if smoke detection were to be used for example where there is a high level of dust fumes steam or smoke under normal conditions.Key FeaturesSoft addressedIntegral short circuit isolatorSingle addressWide range of sensor types360 visibility LED using lightpipe technologyDrift compensationRemovable detector chamberAesthetically pleasingBenefitsQuick and simple to installSingle multi-mode heat sensorWide viewing angle for increased LED visibilityCommon mounting basePositive lock indicationDiscreet design for incorporation into any decorEasy to maintainservice GBP 34.94 1
Cooper CASB393 Open Class Wall Sounder VAD With Isolator Red Body White Flash FXN559LPS MASB880 Cooper CASB393 Open Class Wall Sounder VAD With Isolator Red Body White Flash FXN559LPS MASB880The new intelligent addressable open class visual alarm device CASB393 combines the high output sound of the wall sounders with a brighter LED. It is compliant to EN54-23 3 and 17 making it suitable for use as a Fire notification device within Europe. The CASB393 offers low current consumption maximising the number of devices that can be fitted on a loop and provides a flexible solution due to it soft addressing multiple tone and body options. The open class VAD comes in two variants the standard CASB393 and the weatherproof CASB393WP which is IP66 rated meaning it is ideal for outdoor locations.With both variants the open class VAD is suitable for all markets where EN54-23 VADs are now a requirement.Key FeaturesIntegral short circuit isolatorLoop poweredSoft addressedQuick and simple to installSelectable tones controlled by the panelAdjustable volume controlled by the panelIP66 version available as both an internal and weather-proof variant availableEasy to maintainservice GBP 114.18 1
Cooper CASB393-WP Wall Sounder Weatherproof VAD with Isolator White Flash FXN559LPSWP MASB880WP Cooper CASB393-WP Open Class Wall Sounder Weatherproof VAD with Isolator White Flash FXN559LPSWP MASB880WPThe new intelligent addressable open class visual alarm device CASB393 combines the high output sound of the wall sounders with a brighter LED. It is compliant to EN54-23 3 and 17 making it suitable for use as a Fire notification device within Europe. The CASB393 offers low current consumption maximising the number of devices that can be fitted on a loop and provides a flexible solution due to its soft addressing multiple tone and body options. The open class VAD comes in two variants the standard CASB393 and the weather-proof CASB393WP which is IP66 rated meaning it is ideal for outdoor locations.With both variants the open class VAD is suitable for all markets where EN54-23 VADs are now a requirement.Key FeaturesIntegral short circuit isolatorLoop poweredSoft addressedQuick and simple to installSelectable tones controlled by the panelAdjustable volume controlled by the panelIP66 version available as both an internal and weather-proof variant availableEasy to maintainservice GBP 116.93 1
Cooper EC0232 Lon to RS232 Adapter Cooper EC0232 Lon to RS232 AdapterThe Lon to RS232adapter EC0232allows connection of the Cooper system network LonWorks devices to PC based applications such as site monitor site graphics.The EC0232PAVA offers a similar interfacing facility to the HMX PAVA public addressvoice alarm system by withholding the handshaking functionality and if required the EC0232PAVA3D offers an additional 3 minute time delay before the voice alarm function is actuated. The bi-directional link allows the status of the HMX PAVA system to be displayed and monitored at the control panel. Different messages may be played depending on the configuration of the cause and effect programming.The interface may be located anywhere on the Cooper peer to peer network allowing information from any intelligent addressable control panel to be routed through the bi-directional RS232 port to PC or PAVA system.Key FeaturesAllows connection of Cooper system network devices to PC based applicationsCan be connected at any point on peer to peer networkAllows Cooper system network to be connected to PC or PAVABenefitsIntegrates PC based applicationsIntegrates PAVA systems site monitor and graphpackFlexibility to use any PC application GBP 406.33 1
Cooper Menvier 400003FIRE-0003X Addressable Multi-Mode Heat Sensor Cooper Menvier 400003FIRE-0003X Addressable Multi-Mode HeatSensorThis range of intelligent addressable sensors have been specificallydesigned to operate with Eatons intelligent addressable fire systems.All sensors are third party approved to the relevant sectionof EN54 part 7 for smoke detectors part 5 for heat detectors and part 17 forshort circuit isolators. The optical sensor CAP320 is suitable for most applicationsgiving the fastest response to slow burning or smouldering fires which giverise to large visible smoke particles.The photo-thermal sensor CAPT340 will respond quickly tofast clean burning fires yet maintain the advantage of optical sensors whendetecting smouldering fires The thermal enhancement of this sensor allows ahigher alarm threshold which provides a greater rejection of false alarms. Thesensor will also raise an alarm at temperatures exceeding 60C.The CAPT340 has daynight modes available programmable fromthe site installer software. The day mode uses the heat aspect of the sensorfor areas which may have smoky environments during for example working hours.The night mode uses a combination of A2S and smoke detection. If notprogrammed the sensor defaults to dual mode.The heat sensor CAH330 can be set to one of 3 modes 77C 92C and rate of rise. These sensors are designed to be used in environmentswhere the ambient conditions might cause false alarms if smoke detection wereto be used for example where there is a high level of dust fumes steam orsmoke under normal conditions.Key FeaturesSoft addressedIntegral short circuit isolatorSingle addressWide range of sensor types360 visibility LED using lightpipe technologyDrift compensation GBP 34.94 1
Cooper Menvier 400002FIRE-0002X Addressable Optical Smoke Sensor Cooper Menvier 400002FIRE-0002X Addressable Optical SmokeSensorThis range of intelligent addressable sensors have been specificallydesigned to operate with Eatons intelligent addressable fire systems.All sensors are third party approved to the relevant sectionof EN54 part 7 for smoke detectors part 5 for heat detectors and part 17 forshort circuit isolators. The optical sensor CAP320 is suitable for most applicationsgiving the fastest response to slow burning or smouldering fires which giverise to large visible smoke particles.The photo-thermal sensor CAPT340 will respond quickly tofast clean burning fires yet maintain the advantage of optical sensors whendetecting smouldering fires The thermal enhancement of this sensor allows ahigher alarm threshold which provides a greater rejection of false alarms. Thesensor will also raise an alarm at temperatures exceeding 60C.The CAPT340 has daynight modes available programmable fromthe site installer software. The day mode uses the heat aspect of the sensorfor areas which may have smoky environments during for example working hours.The night mode uses a combination of A2S and smoke detection. If notprogrammed the sensor defaults to dual mode.The heat sensor CAH330 can be set to one of 3 modes 77C 92C and rate of rise. These sensors are designed to be used in environmentswhere the ambient conditions might cause false alarms if smoke detection wereto be used for example where there is a high level of dust fumes steam orsmoke under normal conditions.Key FeaturesSoft addressedIntegral short circuit isolatorSingle addressWide range of sensor types360 visibility LED using lightpipe technologyDrift compensationAesthetically pleasingQuick and simple to installSingle multi-mode heat sensorWide viewing angle for increased LED visibilityCommon mounting basePositive lock indicationDiscreet design for incorporation into any dcorEasy to maintainservice GBP 34.98 1
Cooper Menvier 400004FIRE-0004X Addressable Photo-Thermal Sensor Cooper Menvier 400004FIRE-0004X Addressable Photo-ThermalSensor This range of intelligent addressable sensors have been specificallydesigned to operate with Eatons intelligent addressable fire systems.All sensors are third party approved to the relevant sectionof EN54 part 7 for smoke detectors part 5 for heat detectors and part 17 forshort circuit isolators. The optical sensor CAP320 is suitable for most applicationsgiving the fastest response to slow burning or smouldering fires which giverise to large visible smoke particles.The photo-thermal sensor CAPT340 will respond quickly tofast clean burning fires yet maintain the advantage of optical sensors whendetecting smouldering fires The thermal enhancement of this sensor allows ahigher alarm threshold which provides a greater rejection of false alarms. Thesensor will also raise an alarm at temperatures exceeding 60C.The CAPT340 has daynight modes available programmable fromthe site installer software. The day mode uses the heat aspect of the sensorfor areas which may have smoky environments during for example working hours.The night mode uses a combination of A2S and smoke detection. If notprogrammed the sensor defaults to dual mode.The heat sensor CAH330 can be set to one of 3 modes 77C 92C and rate of rise. These sensors are designed to be used in environmentswhere the ambient conditions might cause false alarms if smoke detection wereto be used for example where there is a high level of dust fumes steam orsmoke under normal conditions.Key FeaturesSoft addressedIntegral short circuit isolatorSingle addressWide range of sensor types360 visibility LED using lightpipe technologyDrift compensationAesthetically pleasingQuick and simple to installSingle multi-mode heat sensorWide viewing angle for increased LED visibilityCommon mounting basePositive lock indicationDiscreet design for incorporation into any dcorEasy to maintainservice GBP 42.90 1