Cooper Bi-Wire Conventional Repeater Panel EFBWCV-REPEATER Cooper Bi-Wire Conventional Repeater Panel EFBWCV-REPEATEREatons new BiWire and Conventional repeater panel is compatible with our 2 zone 4 zone and 8 zone BiWire-Ultra EFBWxZONE BiWire-Flexi EFBWxZFLEXI and latest release of conventional panels EFCV8Z. The EFBWCV repeater panel can be daisy-chained up to 3 panels per control panels.It can repeat information from any zone of the panel it is cabled to. With an integral power supply the only wiring required for the repeater panel is the mains input to the power supply unit and the data cable between the fire control panel and each repeater panel.Key FeaturesCan be used with 2 4 and 8 zone control panelsInternal Power supplySimple unit cablingUp to 3 repeaters per control panelSame modern enclosure as control panelsRepeater panel not out of place in public areas GBP 201.05 1
Cooper EOLM-3 End of Line Module Bi-Wire Circuits Box of 8 Cooper EOLM-3 End of Line Module Bi-Wire Circuits Box of 8Each Zone on the panel that is configured for BiWire mode must have the intelligent end of line module EOLM-3 fitted to continually monitor each zone for the presence of fault conditions such as detector head removal open or short circuit and for end of line failures even when in a Fire condition.For new installations any Zone on the panel that is configured for Conventional mode can use the intelligent end of line module EOLM-3 to terminate the zone but the panel will be limited to only detecting the presence of open or short circuit conditions to make it backward compatible with the EOLM-1. All detector head removals will be seen as an open circuit condition. The EOLM-3 module can be placed into the base of the last manual call point or detector base. GBP 44.06 1
Cooper CASB393 Open Class Wall Sounder VAD With Isolator Red Body White Flash FXN559LPS MASB880 Cooper CASB393 Open Class Wall Sounder VAD With Isolator Red Body White Flash FXN559LPS MASB880The new intelligent addressable open class visual alarm device CASB393 combines the high output sound of the wall sounders with a brighter LED. It is compliant to EN54-23 3 and 17 making it suitable for use as a Fire notification device within Europe. The CASB393 offers low current consumption maximising the number of devices that can be fitted on a loop and provides a flexible solution due to it soft addressing multiple tone and body options. The open class VAD comes in two variants the standard CASB393 and the weatherproof CASB393WP which is IP66 rated meaning it is ideal for outdoor locations.With both variants the open class VAD is suitable for all markets where EN54-23 VADs are now a requirement.Key FeaturesIntegral short circuit isolatorLoop poweredSoft addressedQuick and simple to installSelectable tones controlled by the panelAdjustable volume controlled by the panelIP66 version available as both an internal and weather-proof variant availableEasy to maintainservice GBP 114.18 1
Cooper CASB393-WP Wall Sounder Weatherproof VAD with Isolator White Flash FXN559LPSWP MASB880WP Cooper CASB393-WP Open Class Wall Sounder Weatherproof VAD with Isolator White Flash FXN559LPSWP MASB880WPThe new intelligent addressable open class visual alarm device CASB393 combines the high output sound of the wall sounders with a brighter LED. It is compliant to EN54-23 3 and 17 making it suitable for use as a Fire notification device within Europe. The CASB393 offers low current consumption maximising the number of devices that can be fitted on a loop and provides a flexible solution due to its soft addressing multiple tone and body options. The open class VAD comes in two variants the standard CASB393 and the weather-proof CASB393WP which is IP66 rated meaning it is ideal for outdoor locations.With both variants the open class VAD is suitable for all markets where EN54-23 VADs are now a requirement.Key FeaturesIntegral short circuit isolatorLoop poweredSoft addressedQuick and simple to installSelectable tones controlled by the panelAdjustable volume controlled by the panelIP66 version available as both an internal and weather-proof variant availableEasy to maintainservice GBP 116.93 1
Cooper LP800KIT Loop Tester Kit Cooper LP800KIT Loop Tester KitThe loop tester kit LP800KIT is a hardware software combination that can be used to test commission and fault find a loop of up to 200 intelligent addressable devices sensors sounders ancillary devices without having to connect the loop to Eatons intelligent addressable control panel. The loop tester is connected between the loop and PC.It allows the engineer to quickly identify and locate any loop device that is operating outside its operating conditions by varying the alarm threshold of any loop device alarm pre-alarm and fault.The Loop tester hardware requires a free serial port on the PC either internet or via a USB extension a mains power supply and a direct connection to the device loop.Key FeaturesPre-addressing Identifies all field devices and determines their address and device type.Analogue values Constantly displays in real time the analogue value of all loop devices in order to determine their status.Test LED This command operates the LED of any inputs sensorscall points as well as controls the outputs of sounders and output modules.Device settings Analogue values of all devices can be interpreted according to ranges which can be set and altered by the user OK pre-alarm fire.Event Log A history of events can be stored from the date the application was started.Soft addressing Automatically assigns a new and potentially different address to every device found on the loop. GBP 623.41 1