Cooper Bi-Wire External Relay 24v BWEXTR24V Cooper Bi-Wire External Relay 24v BWEXTR24VThe BiWire Ultra output relay module is designed to provide a simple means of interfacing BiWire Ultra systems with external equipment such as door retainers. It is simple to install and can provide additional flexibility to an installer as external switching can be achieved without having to wire back to the main fire alarm control panel. The module range is available in 24V and 230V variants.Key FeaturesQuick and simple to installProvides flexibility at system installation24V and 230V variants provide for low or mains voltage switchingInstallationRemove the lid from the back box.Unclip the PCB from the mounting pillars to prevent damage during drilling.Remove the mounting plate via the two screws so you can gain access to the base of the back box.Mark on the back box where the glands will be fitted making sure there is sufficient space between glands so they can be tightened properly.Using the appropriate sized cutting drill for the gland size used drill out the marked gland points on the back-box.Fit the glands to the newly drilled holes in the back box.Drill the holes in the wall to match the holes in the back box see picture on right.Screw the back-box in position see picture on right.Screw the mounting plate back into the back box.Clip the PCB into the mounting pillars on the mounting plate.Pass the wires through the glands and secure to the PCB as outlined in the wiring instructions.Secure the lid to the back box. GBP 100.50 1
Cooper Bi-Wire Option Board 8 Relay BWOB8Z Cooper Bi-Wire Option Board 8 Relay BWOB8ZEatons BiWire Ultra Option is an additional daughter card that provides outputs to Fire Protection Equipment FPE Fire Alarm Routing Equipment FRE and Zone Relays. The FRE output is design to activate during a fire event and is connected to phone diallers andor Building Management Systems - the output complies with EN54-2.The FPR output is designed to activate during a fire event and when connected to an external device drive door release mechanism fire screens sprinkler system and gas release systems. Zone relay contacts are volt free and do not provide any voltage. The relays are selectable to be either set to CNO or CNC. The zonal relays are designed to follow the fire condition of the associated zone circuits on the Main Board. GBP 44.39 1
Cooper Bi-Wire Option Board 4 Relay BWOB4Z Cooper Bi-Wire Option Board 4 Relay BWOB4ZEatons BiWire Ultra Option is an additional daughter card that provides outputs to Fire Protection Equipment FPE Fire Alarm Routing Equipment FRE and Zone Relays. The FRE output is design to activate during a fire event and is connected to phone diallers andor Building Management Systems - the output complies with EN54-2.The FPR output is designed to activate during a fire event and when connected to an external device drive door release mechanism fire screens sprinkler system and gas release systems. Zone relay contacts are volt free and do not provide any voltage. The relays are selectable to be either set to CNO or CNC. The zonal relays are designed to follow the fire condition of the associated zone circuits on the Main Board. GBP 34.52 1
Cooper Bi-Wire Option Board 2 Relay BWOB2Z Cooper Bi-Wire Option Board 2 Relay BWOB2ZEatons BiWire Ultra Option is an additional daughter card that provides outputs to Fire Protection Equipment FPE Fire Alarm Routing Equipment FRE and Zone Relays. The FRE output is design to activate during a fire event and is connected to phone diallers andor Building Management Systems - the output complies with EN54-2.The FPR output is designed to activate during a fire event and when connected to an external device drive door release mechanism fire screens sprinkler system and gas release systems. Zone relay contacts are volt free and do not provide any voltage. The relays are selectable to be either set to CNO or CNC. The zonal relays are designed to follow the fire condition of the associated zone circuits on the Main Board. GBP 29.59 1
Cooper Bi-Wire Conventional Repeater Panel EFBWCV-REPEATER Cooper Bi-Wire Conventional Repeater Panel EFBWCV-REPEATEREatons new BiWire and Conventional repeater panel is compatible with our 2 zone 4 zone and 8 zone BiWire-Ultra EFBWxZONE BiWire-Flexi EFBWxZFLEXI and latest release of conventional panels EFCV8Z. The EFBWCV repeater panel can be daisy-chained up to 3 panels per control panels.It can repeat information from any zone of the panel it is cabled to. With an integral power supply the only wiring required for the repeater panel is the mains input to the power supply unit and the data cable between the fire control panel and each repeater panel.Key FeaturesCan be used with 2 4 and 8 zone control panelsInternal Power supplySimple unit cablingUp to 3 repeaters per control panelSame modern enclosure as control panelsRepeater panel not out of place in public areas GBP 201.05 1
Cooper Bi-Wire Base Sounder VAD Beacon EF5021BWSB Cooper Bi-Wire Base Sounder VAD Beacon EF5021BWSBThe BiWire base sounder and base sounder VAD can be used either with a sensor or as a standalone device. The base sounders are approved to EN54-23 and are compatible with the BiWire 5 in 1 detector as part of Eatons BiWire Ultra fire system. The base sounder and base sounder VAD both incorporate a sensor mounting base a sensor can be fitted directly to the base or alternatively an optional cover plate can be used to provide a dedicated discreetKey FeaturesStandalone deviceAvailable in both sounder only and sounder VADCertified to EN54-3 EN54-23Standalone base sounder or base sounder VAD offers the flexibility of use with or without the detectorCover plate optionalFirst fix base offers a compact design and reduces time of installation of the base with the detectorEasy to maintain and service GBP 38.76 1
Cooper Bi-Wire Weatherproof Call Point EF203BWCPWP Cooper Bi-Wire Weatherproof Call Point EF203BWCPWPTwo versions of the BiWire call points are available in this range the EF201BWCP which can be either surface or flush mounted and the EF203BWCPWP which is a weather-proof version. Both the EF201BWCP and the EF203BWCPWP are compatible with the Eatons BiWire Ultra range of fire systems.These call points are design for fast and simple installation and are supplied as standard with a frangible glass element and a test key for ease of maintenance. A comprehensive range of accessories is available to maximise the functionality of the call point for particular applications.Key FeaturesFast fit clip on front coverWide range of accessoriesHeavy duty terminalsTwo models availableSingle tool for test and accessRobust constructionIP65 version availableQuick and simple to installEasy to maintain and serviceVersatile installationWeather-proof variant suitable for outside usePlease Note This product is not compatible with the older Cooper Bi-Wire range. GBP 22.03 1
Cooper Bi-Wire Flexi 4 Zone Panel EFBW4ZFLEXI Cooper Bi-Wire Flexi 4 Zone Panel EFBW4ZFLEXIBiWire Flexi combines two technologies to provide a truly versatile fire safety solution. The panel can be configured to allow either two-wire or conventional devices to work on a zone. Each zone is individually configurable so a mixture of types can therefore be installed on the same system. This provides you with the flexibility to utilise all the time-saving benefits of a two-wire system with the ability to use a wide range of conventional devices where required.It shares the same straightforward intuitive interface as the BiWire Ultra and EFCV8Zone conventional panels providing a proven solution for simple programming and maintenance. The BiWire Flexi fire alarm system is certified to EN54 part2 and part 4 and is designed to meet the recommendations of BS5839.Key FeaturesConfigure zone wiring to work as either a conventional or two-wire systemAvailable in 2 4 and 8 zone variantsAllows the connection of an existing conventional system to a BiWire systemCompatible with two-wire and conventional EN 54-23 certified visual alarm devices VADsReduces stock-holding and enables the fire system to adapt to the demands of the customer or applicationSimple to sell and specify Flexi can be used in a wide variety of applications and is very simple to installSave time money and effort when undertaking system extensions and upgradesUp-to-date with latest regulations GBP 247.78 1
Cooper Bi-Wire Flexi 8 Zone Panel EFBW8ZFLEXI Cooper Bi-Wire Flexi 8 Zone Panel EFBW8ZFLEXIBiWire Flexi combines two technologies to provide a truly versatile fire safety solution. The panel can be configured to allow either two-wire or conventional devices to work on a zone. Each zone is individually configurable so a mixture of types can therefore be installed on the same system. This provides you with the flexibility to utilise all the time-saving benefits of a two-wire system with the ability to use a wide range of conventional devices where required.It shares the same straightforward intuitive interface as the BiWire Ultra and EFCV8Zone conventional panels providing a proven solution for simple programming and maintenance. The BiWire Flexi fire alarm system is certified to EN54 part2 and part 4 and is designed to meet the recommendations of BS5839.Key FeaturesConfigure zone wiring to work as either a conventional or two-wire systemAvailable in 2 4 and 8 zone variantsAllows the connection of an existing conventional system to a BiWire systemCompatible with two-wire and conventional EN 54-23 certified visual alarm devices VADsReduces stock-holding and enables the fire system to adapt to the demands of the customer or applicationSimple to sell and specify Flexi can be used in a wide variety of applications and is very simple to installSave time money and effort when undertaking system extensions and upgradesUp-to-date with latest regulations GBP 290.23 1
Cooper Bi-Wire Flexi 2 Zone Panel EFBW2ZFLEXI Cooper Bi-Wire Flexi 2 Zone Panel EFBW2ZFLEXIBiWire Flexi combines two technologies to provide a truly versatile fire safety solution. The panel can be configured to allow either two-wire or conventional devices to work on a zone. Each zone is individually configurable so a mixture of types can therefore be installed on the same system. This provides you with the flexibility to utilise all the time-saving benefits of a two-wire system with the ability to use a wide range of conventional devices where required.It shares the same straightforward intuitive interface as the BiWire Ultra and EFCV8Zone conventional panels providing a proven solution for simple programming and maintenance. The BiWire Flexi fire alarm system is certified to EN54 part2 and part 4 and is designed to meet the recommendations of BS5839Key FeaturesConfigure zone wiring to work as either a conventional or two-wire systemAvailable in 2 4 and 8 zone variantsAllows the connection of an existing conventional system to a BiWire systemCompatible with two-wire and conventional EN 54-23 certified visual alarm devices VADsReduces stock-holding and enables the fire system to adapt to the demands of the customer or applicationSimple to sell and specify Flexi can be used in a wide variety of applications and is very simple to installSave time money and effort when undertaking system extensions and upgradesUp-to-date with latest regulations GBP 220.32 1