Carrier I-9403 Intelligent SounderVisual Indicator - 24VDC Carrier I-9403 Intelligent SounderVisual Indicator - 24VDCI-9403 Intelligent Sounder Strobe is an audible and visual alarm device installed in field which can be activated by fire alarm control panel in fire control centre. After activated it will generate strong audible and visual alarm signal to warn people in field.A 25.5mm high shallow base and a 40mm high deep base are available. The sounder strobe comes with the shallow base. The deep base C-94DB should be ordered separately.Key FeaturesProviding 16 tonesUsing ultra bright LEDs as source for light indicationOptional transparent colourless lens C-94WL availableLoop powered or external 24V poweredPower-saving consumption mode and normal consumption mode factory defaultSingledual address programmableWorking modes sounder strobe strobe only sounder onlyStandard EN 54-3 GBP 48.52 1
Carrier POE304-EX-4P-V2 POE-BT To Gigabit Ethernet 4-port Poe Extender Carrier POE304-EX-4P-V2 POE-BT To Gigabit Ethernet 4-port Poe ExtenderThe IFS POE304-EX-4P-V2 is remotely powered via Ethernet cable from a PoE-bt injecting device eliminating the need for local power requirements. The POE304-EX-4P-V2 can then transmit up to 4-ports of Ethernet data and PoE-afat power dependent on the Powered Devices PD power demand.The IFS PoE-bt solution facilitates easier network planning by eliminating restrictions of edge device placement near AC power outlets and reducing the need for AC wiring and installation costs.Key Features4-Port POE Switch powered by 1 x POE-bt input up to 95WUp to 75 watts shared POE powerPlug-and-play self-powered designCan be used with an IFS PoE-Ultra Injector or other POE-bt compliantPSE equipmentSupports 101001000Base-T EthernetAuto-detect of PoE equipment providing protection from incorrect installationCurrent overload detectionLED Indicators for PoE In PoE Out DataCan be daisy-chained to extend data and PoE on a single network cable a maximum of 300m GBP 229.66 1
Carrier 5150-W 2-Wire On-The-Glass Piezo Sensor With 30 cm Wire Leads NC Alarm Output Carrier 5150-W 2-Wire On-The-Glass Piezo Sensor With 30 cm Wire Leads NC Alarm OutputThe Sentrol 5150 series glass break detector has been designed using the latest electronic techniques. This enables the detector to contain all the necessary circuitry for excellent detection whilst filtering out and rejecting all unwanted signals that would normally result in a nuisance alarms e.g. ultra-sound radio frequency interference etc. The 5150 series will provide a 3 m radius of protection. Suitable for use on standard window glass plate wired tempered and laminated glass.Due to the design of the product the detector may be fitted as close as 2.5 cm from the window frame and still provide a full 3 m radius. The 5150 series detectors are passive sensors therefore any number of detectors may be installed on the same windowpane without the risk of interaction. The detectors use a fail-safe normally closed open to alarm relay contact enabling compatibility with any standard burglar alarm control equipment.The output from the relay contact should be connected via the alarm 24-hour tamper loop in order to provide early signalling at the control whether the alarm is switched on or off. The opening of the normally closed relay contact signals the alarm.Easily installs with pre-cut specially formulated 3M adhesive tape.Key Features3 m radius of coverage measured from the sensorProtects all glass types up to a standard thickness of 6.4 mm includingplate wired tempered and laminated glassIdeal for 24-hours loop protectionTwo wire sensor drawing no power from the loopCompatible with most wireless transmitters GBP 12.82 1
Carrier 5150-M 2-Wire On-The-Glass Piezo Sensor With 30 cm Wire Leads NC Alarm Output Carrier 5150-M 2-Wire On-The-Glass Piezo Sensor With 30 cm Wire Leads NC Alarm OutputThe Sentrol 5150 series glass break detector has been designed using the latest electronic techniques. This enables the detector to contain all the necessary circuitry for excellent detection whilst filtering out and rejecting all unwanted signals that would normally result in a nuisance alarms e.g. ultra-sound radio frequency interference etc. The 5150 series will provide a 3 m radius of protection. Suitable for use on standard window glass plate wired tempered and laminated glass.Due to the design of the product the detector may be fitted as close as 2.5 cm from the window frame and still provide a full 3 m radius. The 5150 series detectors are passive sensors therefore any number of detectors may be installed on the same windowpane without the risk of interaction. The detectors use a fail-safe normally closed open to alarm relay contact enabling compatibility with any standard burglar alarm control equipment.The output from the relay contact should be connected via the alarm 24-hour tamper loop in order to provide early signalling at the control whether the alarm is switched on or off. The opening of the normally closed relay contact signals the alarm.Easily installs with pre-cut specially formulated 3M adhesive tape.Key Features3 m radius of coverage measured from the sensorProtects all glass types up to a standard thickness of 6.4 mm includingplate wired tempered and laminated glassIdeal for 24-hours loop protectionTwo wire sensor drawing no power from the loopCompatible with most wireless transmitters GBP 13.24 1