18 results (0,15174 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

C-Tec FiTT EVC Line Tester

C-Tec CFP Relay Output Card Reset Fault Aux amp Remote Relay Outputs CFP762

C-Tec Output Expansion Relay Board EP212

C-Tec CA734 CA Mini Input Output Module

C-Tec 24V 3A EN54-4 Switch Mode PSU BF562-3

C-Tec 24V 1.5A 5 Series Encased Power Supply PCB ONLY BF560-24E

C-Tec 24V 3A 5 Series Encased Power Supply PCB ONLY BF562-3E

C-Tec 24V 5A 5 Series Encased Power Supply PCB ONLY BF562-5E

C-Tec CFP763 Relay Output Card as per CFP762 8 outputs per zone relays

C-Tec CA730 CA Input Output Module

C-Tec CA731 CA Mains Switching Input Output Module

C-Tec QT603 Quantec Network Splitter

C-Tec QT603 Quantec Network Splitter

C-Tec QT603 Quantec Network SplitterQuantec utilises a unique data protocol that works down two wires andamaximum of 255 addressable devices can be connected to a Quantec Controller dependent on network topology.Addressable devices require 2 network connections. Slave devices such as slave ceiling pullsandslave overdoor lights connect to Quantec via a master call point master ceiling receiver monitoring point or universal programming device using 2 3 or 4 cores of stranded security cable.Wiring must bemade in a Spine and Limb configuration using one or more QT603 network splitters. This allowsthe use of ordinary unscreened cable which simplifies installation fault-finding and commissioning.Key FeaturesAn essential wiringinstallation aid for C-TECsQuantec Addressable Call System.Helps protect against open and short circuit faults and reduces the risk of volt drop.Includes one input and one output connection for Quantecs Spine wiring typically 1.5-2.5mm TE and sixfused 400mA limb connections for the wiring of individual circuits containing Quantecs fielddevices typically 4 core stranded security cable.At least one QT603 is required perQuantec system the more you use the easier it will beto program and fault-find.Install one QT603 per corridor junction locate at the end of the corridor nearest to the Quantec Controller.Ifthe corridor is longer than 50m install the splitter in the centre of the corridor to reduce wiring runs.Mounts on a standard 25mm UK double gang back box.Power and Fault indicators.Max.60 addressable devices per QT603.

GBP 29.40
1

C-Tec NC832KE Conventional 30 Zone Surface Emergency Master Panel

C-Tec NC832KE Conventional 30 Zone Surface Emergency Master Panel

C-Tec NC832KE Conventional 30 Zone Surface Emergency Master PanelNC812KE NC822KE and NC832KE indicator panels are fully compatible with all 800 Series call points ceiling pulls infrared ceiling receivers monitoring points overdoor lights and remote sounders.Depending on the devices wired to it Standard and Emergency calls can be indicated via its buzzer and zonal LEDs. An optional Mute button is also provided to allow the user to silence standard calls.Standard Calls when triggered by a calling device the indicator panels internal buzzer sounds continuously and the relevant zone indicators illuminate steady.Pressing the Indicator Panels Mute Button if fitted silences the Panels internal buzzer. However if a new call standard or emergency is triggered anywhere on the system the buzzer will resound.Emergency Calls when triggered by a calling device theIndicator Panels internal buzzer pulses and the relevant zone indicators flash. This level of call takes priority over standard calls and cannot be muted at the Panel. An emergency call can only be reset at the device from which it was triggered or via a reset point wired on the same zone.Key FeaturesFully compatible with C-TECs entire range of 800 Series Call System componentsCapable of indicating standard constant tone and emergency intermittent tone calls10 20 or 30 zonal alarm LEDs dependent on model purchased see below for parts listingOptional mute button2 volt-free relay contactsSurface mountingConnections for optional Repeater panels and sounders to increase call indication levels

GBP 466.69
1

C-Tec NC910S Conventional 10 Zone Surface Master Call Controller

C-Tec NC910S Conventional 10 Zone Surface Master Call Controller

C-Tec NC910S Conventional 10 Zone Surface Master Call ControllerThe NC910S Call Controller is compatible with all 800 Series call points ceiling pulls infrared ceiling receivers monitoring points overdoor lights and remote sounders.Depending on how the Controller is configured and the devices connected to it Standard and Emergency calls can be indicated via its buzzer and zonal LEDs. Two buttons A and B are also provided to allow the user to Reset Mute or Accept standard calls as detailed below.Standard Calls when triggered by a calling device the Controllers internal buzzer sounds continuously and the relevant zone indicators illuminate steady.Pressing the Controllers Reset Button A if enabled cancels all standard calls.Pressing the Controllers Mute Button B if enabled silences the Controllers internal buzzer. However if a new call standard or emergency is triggered anywhere on the system the buzzer will resound.Alternatively instead of muting calls Button B can be configured as a CALL ACCEPT button.Pressing Call Accept sends a slow pulsing acknowledgement signal to overdoor lights and reset points cw sounders provided they are wired as shown on the example wiring diagram below. Should a new call standard or emergency be triggered anywhere on the system any zones in the acknowledgement state will revert to a standard call.Emergency Calls when triggered by a calling device the Controllers internal buzzer pulses and the relevant zone indicators flash. This level of call takes priority over standard calls and cannot be muted accepted or reset at the Controller. An emergency call can only be reset at the device from which it was triggered or via a reset point wired on the same zone.Key FeaturesCompatible with C-TECs entire range of 800 Series field devicesHoused in an attractive surface mounting plastic enclosure measuring just 214mm x 178mmTwo call levels - standard constant tone and emergency intermittent toneOptional mute and call acceptreset buttonsCall Accept functionality allows staff to send an intermittent call acknowledgment signal to calling zones to confirm help is on the way dependent on wiring and field devices usedIncludes a 12V 300mA PSU and 2 volt-free relay contacts which activate on a standard or emergency callInnovative slide-in labelling systemZones can be wired in 4 or 6 core 702 stranded security cableAdditional master controllers and expansion units available for use as repeaters on larger sitesOptional boxed PSUs cw with space for a 12V VRLA battery available for sites where a standby battery facility is required

GBP 234.98
1

C-Tec EP203 3 Zone Automatic Extinguisher Panel LPCB Certified - EP203

C-Tec EP203 3 Zone Automatic Extinguisher Panel LPCB Certified - EP203

C-Tec EP203 3 Zone Automatic Extinguisher Panel LPCB Certified - EP203The EP203 three zone automatic extinguisher panel has been specifically designed for use in areas housing expensive dangerous or irreplaceable items of equipment. Third-party approved by the LPCB to EN 12094-1 the European standard for Fixed Firefighting Systems - Components for Gas Extinguishing Systems and EN54 parts 2 and 4 the panel epitomises quality durability and reliability.Featuring an intuitive 128 x 64 pixel two-colour graphic display that gives clear and concise feedback to the user installer and commissioning engineer the panel also includes six monitored inputs including hold and abort a time stamped log adjustable flood times and volt-free changeover relays for fire local fire 1st stage active 2nd stage active extractor fan and fault.The panel is supplied in an elegantly styled durable enclosure with all of its electronics - apart from its powerful 3A EN54-4 switch mode PSU - mounted on a detachable metal bridge plate for ease of installation. A wide range of ancillaries are also available including remote status units hold-off and abort buttons line terminators and output expansion relay boards.Key FeaturesThird-party LPCB certificated to EN 12094 part 1 and EN54 parts 2 and 4Functions as a standard three zone fire panel with additional circuitry for controlling the release of fire-suppressing gas into protected areasUnique 128 x 64 pixel graphical display facilitates straightforward system programmingAny combination of activated zones can be programmed to automatically start the panels extinguishant release sequenceIncludes a pull-down front-panel manual release button and two keyswitches for accessing the panels functions and toggling between automanual modeThree conventional sounder circuits two x 1st stage one x 2nd stagePowerful 3A EN54-4 compliant switch mode PSULow quiescent current - less than 40mA on mains failWide range of monitored inputs and auxiliary outputs see schematicAbort and hold inputs allow the panels release sequence to be cancelled or suspended at any timeTime-stamped event logRS485 connections for up to eight flush or surface remote status units with their own LCDs manual release and mode automanual switches. Single gang economy status units without an LCD are also available.Extensive range of commissioning and engineering functionsOptional relay expansion boards and single gang abort and hold buttonsIdeal for use in computer rooms telecommunication centres archive storage areas chemical plants generator rooms museums etc..System line terminator included with all panels

GBP 399.43
1

C-Tec NC910F Conventional 10 Zone Flush Master Call Controller

C-Tec NC910F Conventional 10 Zone Flush Master Call Controller

C-Tec NC910F Conventional 10 Zone Flush Master Call ControllerThe NC910FCall Controller is compatible with all 800 Series call points ceiling pulls infrared ceiling receivers monitoring points overdoor lights and remote sounders.Depending on how the Controller is configured and the devices connected to it Standard and Emergency calls can be indicated via its buzzer and zonal LEDs. Two buttons A and B are also provided to allow the user to Reset Mute or Accept standard calls as detailed below.Standard Calls when triggered by a calling device the Controllers internal buzzer sounds continuously and the relevant zone indicators illuminate steady.Pressing the Controllers Reset Button A if enabled cancels all standard calls.Pressing the Controllers Mute Button B if enabled silences the Controllers internal buzzer. However if a new call standard or emergency is triggered anywhere on the system the buzzer will resound.Alternatively instead of muting calls Button B can be configured as a CALL ACCEPT button.Pressing Call Accept sends a slow pulsing acknowledgement signal to overdoor lights and reset points cw sounders provided they are wired as shown on the example wiring diagram below. Should a new call standard or emergency be triggered anywhere on the system any zones in the acknowledgement state will revert to a standard call.Emergency Calls when triggered by a calling device the Controllers internal buzzer pulses and the relevant zone indicators flash. This level of call takes priority over standard calls and cannot be muted accepted or reset at the Controller. An emergency call can only be reset at the device from which it was triggered or via a reset point wired on the same zone.Key FeaturesCompatible with C-TECs entire range of 800 Series field devicesHoused in an attractive flush mounting plastic enclosure measuring just 214mm x 178mmTwo call levels - standard constant tone and emergency intermittent toneOptional mute and call acceptreset buttonsCall Accept functionality allows staff to send an intermittent call acknowledgment signal to calling zones to confirm help is on the way dependent on wiring and field devices usedIncludes a 12V 300mA PSU and 2 volt-free relay contacts which activate on a standard or emergency callInnovative slide-in labelling systemZones can be wired in 4 or 6 core 702 stranded security cableAdditional master controllers and expansion units available for use as repeaters on larger sitesOptional boxed PSUs cw with space for a 12V VRLA battery available for sites where a standby battery facility is required

GBP 228.82
1

C-Tec NC920F Conventional 20 Zone Flush Master Call Controller

C-Tec NC920F Conventional 20 Zone Flush Master Call Controller

C-Tec NC920F Conventional 20 Zone Flush Master Call ControllerThe NC920FCall Controller is compatible with all 800 Series call points ceiling pulls infrared ceiling receivers monitoring points overdoor lights and remote sounders.Depending on how the Controller is configured and the devices connected to it Standard and Emergency calls can be indicated via its buzzer and zonal LEDs. Two buttons A and B are also provided to allow the user to Reset Mute or Accept standard calls as detailed below.Standard Calls when triggered by a calling device the Controllers internal buzzer sounds continuously and the relevant zone indicators illuminate steady.Pressing the Controllers Reset Button A if enabled cancels all standard calls.Pressing the Controllers Mute Button B if enabled silences the Controllers internal buzzer. However if a new call standard or emergency is triggered anywhere on the system the buzzer will resound.Alternatively instead of muting calls Button B can be configured as a CALL ACCEPT button.Pressing Call Accept sends a slow pulsing acknowledgement signal to overdoor lights and reset points cw sounders provided they are wired as shown on the example wiring diagram below. Should a new call standard or emergency be triggered anywhere on the system any zones in the acknowledgement state will revert to a standard call.Emergency Calls when triggered by a calling device the Controllers internal buzzer pulses and the relevant zone indicators flash. This level of call takes priority over standard calls and cannot be muted accepted or reset at the Controller. An emergency call can only be reset at the device from which it was triggered or via a reset point wired on the same zone.Key FeaturesCompatible with C-TECs entire range of 800 Series field devicesHoused in an attractive flush mounting plastic enclosure measuring just 214mm x 178mmTwo call levels - standard constant tone and emergency intermittent toneOptional mute and call acceptreset buttonsCall Accept functionality allows staff to send an intermittent call acknowledgment signal to calling zones to confirm help is on the way dependent on wiring and field devices usedIncludes a 12V 300mA PSU and 2 volt-free relay contacts which activate on a standard or emergency callInnovative slide-in labelling systemZones can be wired in 4 or 6 core 702 stranded security cableAdditional master controllers and expansion units available for use as repeaters on larger sitesOptional boxed PSUs cw with space for a 12V VRLA battery available for sites where a standby battery facility is required

GBP 309.20
1

C-Tec NC920S Conventional 20 Zone Surface Master Call Controller

C-Tec NC920S Conventional 20 Zone Surface Master Call Controller

C-Tec NC920S Conventional 20 Zone Surface Master Call ControllerThe NC920S Call Controller is compatible with all 800 Series call points ceiling pulls infrared ceiling receivers monitoring points overdoor lights and remote sounders.Depending on how the Controller is configured and the devices connected to it Standard and Emergency calls can be indicated via its buzzer and zonal LEDs. Two buttons A and B are also provided to allow the user to Reset Mute or Accept standard calls as detailed below.Standard Calls when triggered by a calling device the Controllers internal buzzer sounds continuously and the relevant zone indicators illuminate steady.Pressing the Controllers Reset Button A if enabled cancels all standard calls.Pressing the Controllers Mute Button B if enabled silences the Controllers internal buzzer. However if a new call standard or emergency is triggered anywhere on the system the buzzer will resound.Alternatively instead of muting calls Button B can be configured as a CALL ACCEPT button.Pressing Call Accept sends a slow pulsing acknowledgement signal to overdoor lights and reset points cw sounders provided they are wired as shown on the example wiring diagram below. Should a new call standard or emergency be triggered anywhere on the system any zones in the acknowledgement state will revert to a standard call.Emergency Calls when triggered by a calling device the Controllers internal buzzer pulses and the relevant zone indicators flash. This level of call takes priority over standard calls and cannot be muted accepted or reset at the Controller. An emergency call can only be reset at the device from which it was triggered or via a reset point wired on the same zone.Key FeaturesCompatible with C-TECs entire range of 800 Series field devicesHoused in an attractive surface mounting plastic enclosure measuring just 214mm x 178mmTwo call levels - standard constant tone and emergency intermittent toneOptional mute and call acceptreset buttonsCall Accept functionality allows staff to send an intermittent call acknowledgment signal to calling zones to confirm help is on the way dependent on wiring and field devices usedIncludes a 12V 300mA PSU and 2 volt-free relay contacts which activate on a standard or emergency callInnovative slide-in labelling systemZones can be wired in 4 or 6 core 702 stranded security cableAdditional master controllers and expansion units available for use as repeaters on larger sitesOptional boxed PSUs cw with space for a 12V VRLA battery available for sites where a standby battery facility is required

GBP 315.38
1