C-Tec APXO XLR Balanced Line Output Plate C-Tec APXO XLR Balanced Line Output PlateThe APXO balanced line output plate provides an adjustable balanced line output 12B max. on a standard 2 pin XLR connector. Typically used to connect an outreach chain to third-party audio equipment such as conventional amplifier. GBP 73.18 1
C-Tec APXM XLR 3 Pin Microphone Plate C-Tec APXM XLR 3 Pin Microphone PlateThe Outreach Plate audio input extension system comprises a range of wall ceiling and desk mountable plates specifically designed to increase the audio input capability of any audio system. Covering the most common variants of audio connectors they work by mixing the signals from various audio input sources into a single balanced line level input on a compatible amplifier. Each input plate features a built-in mixer preamp input level control and balanced output.Typically up to 10Outreach plates any mix can be daisy-chained to one balanced line level connection with cable lengths up to 100m easily achievable using standard two-pair audio cable i.e. Belden 8723. Each plate requires four wires two balanced line LineA LineA one ground GND and one power connection V 12-32V d.c..Most of C-TECs PDA Range induction loop amplifiers are fitted with an Outreach connection socket as standard. For audio systems that do not have an Outreach socket straightforward network connection can be achieved using an APV 24V 250mA d.c. regulated power supply and an APXO 3 pin XLR balanced line output plate.Key FeaturesAccepts balanced or unbalanced microphones with standard 3 pin XLR connectors.Part of C-TECs patented Outreach Plate audio input extension system.Compatible with C-TECs entire range of PDA102 200E Pro-Rangeand ML1 induction loop amplifiers.Can be connected to any third-party audio or induction loop amplifier using an APV 24V 250mA power supply.Mounts on a 25mm standard UK single gang back box. GBP 47.30 1
C-Tec APXL XLR 3 Pin Line Level Plate C-Tec APXL XLR 3 Pin Line Level PlateThe Outreach Plate audio input extension system comprises a range of wall ceiling and desk mountable plates specifically designed to increase the audio input capability of any audio system. Covering the most common variants of audio connectors they work by mixing the signals from various audio input sources into a single balanced line level input on a compatible amplifier. Each input plate features a built-in mixer preamp input level control and balanced output.Typically up to 10Outreach plates any mix can be daisy-chained to one balanced line level connection with cable lengths up to 100m easily achievable using standard two-pair audio cable i.e. Belden 8723. Each plate requires four wires two balanced line LineA LineA one ground GND and one power connection V 12-32V d.c..Most of C-TECs PDA Range induction loop amplifiers are fitted with an Outreach connection socket as standard. For audio systems that do not have an Outreach socket straightforward network connection can be achieved using an APV 24V 250mA d.c. regulated power supply and an APXO 3 pin XLR balanced line output plate.Key FeaturesAccepts stereo phono line-level input signals from sources such as TVs.Part of C-TECs patented Outreach Plate audio input extension system.Compatible with C-TECs entire range of PDA102 200E Pro-Rangeand ML1 induction loop amplifiers.Can be connected to any third-party audio or induction loop amplifier using an APV 24V 250mA power supply.Mounts on a 25mm standard UK single gang back box. GBP 47.64 1
C-Tec APQM Microphone Jack Plate 6.35mm C-Tec APQM Microphone Jack Plate 6.35mm The Outreach Plate audio input extension system comprises a range of wall ceiling and desk mountable plates specifically designed to increase the audio input capability of any audio system. Covering the most common variants of audio connectors they work by mixing the signals from various audio input sources into a single balanced line level input on a compatible amplifier.Each input plate features a built-in mixer preamp input level control and balanced output. Typically up to 10Outreach plates any mix can be daisy-chained to one balanced line level connection with cable lengths up to 100m easily achievable using standard two-pair audio cable i.e. Belden 8723.Each plate requires four wires two balanced line LineA LineA one ground GND and one power connection V 12-32V d.c.. Most of C-TECs PDA Range induction loop amplifiers are fitted with an Outreach connection socket as standard. For audio systems that do not have an Outreach socket straightforward network connection can be achieved using an APV 24V 250mA d.c. regulated power supply and an APXO 3 pin XLR balanced line output plate.Key FeaturesAccepts balanced or unbalanced electret microphones with 6.35mm 14 jack plugs.Part of C-TECs patented Outreach Plate audio input extension system.Compatible with C-TECs entire range of PDA102 200E Pro-Rangeand ML1 induction loop amplifiers.Can be connected to any third-party audio or induction loop amplifier using an APV 24V 250mA power supply.Mounts on a 25mm standard UK single gang back box. GBP 49.57 1
C-Tec APQL Line Level Jack Plate 6.35mm C-Tec APQL Line Level Jack Plate 6.35mmThe Outreach Plate audio input extension system comprises a range of wall ceiling and desk mountable plates specifically designed to increase the audio input capability of any audio system. Covering the most common variants of audio connectors they work by mixing the signals from various audio input sources into a single balanced line level input on a compatible amplifier. Each input plate features a built-in mixer preamp input level control and balanced output.Typically up to 10Outreach plates any mix can be daisy-chained to one balanced line level connection with cable lengths up to 100m easily achievable using standard two-pair audio cable i.e. Belden 8723. Each plate requires four wires two balanced line LineA LineA one ground GND and one power connection V 12-32V d.c..Most of C-TECs PDA Range induction loop amplifiers are fitted with an Outreach connection socket as standard. For audio systems that do not have an Outreach socket straightforward network connection can be achieved using an APV 24V 250mA d.c. regulated power supply and an APXO 3 pin XLR balanced line output plate.Key FeaturesAccepts 6.35mm 14 jack feeds from audio equipment such as stage or church mixing desks etc.Part of C-TECs patented Outreach Plate audio input extension system.Compatible with C-TECs entire range of PDA102 200E Pro-Rangeand ML1 induction loop amplifiers.Can be connected to any third-party audio or induction loop amplifier using an APV 24V 250mA power supply.Mounts on a 25mm standard UK single gang back box. GBP 49.57 1
C-Tec APJ Microphone Jack Outreach Plate 3.5mm C-Tec APJ Microphone Jack Outreach Plate 3.5mmThe Outreach Plate audio input extension system comprises a range of wall ceiling and desk mountable plates specifically designed to increase the audio input capability of any audio system. Covering the most common variants of audio connectors they work by mixing the signals from various audio input sources into a single balanced line level input on a compatible amplifier. Each input plate features a built-in mixer preamp input level control and balanced output.Typically up to 10Outreach plates any mix can be daisy-chained to one balanced line level connection with cable lengths up to 100m easily achievable using standard two-pair audio cable i.e. Belden 8723. Each plate requires four wires two balanced line LineA LineA one ground GND and one power connection V 12-32V d.c..Most of C-Tecs PDA Range induction loop amplifiers are fitted with an Outreach connection socket as standard. For audio systems that do not have an Outreach socket straightforward network connection can be achieved using an APV 24V 250mA d.c. regulated power supply and an APXO 3 pin XLR balanced line output plate.Key FeaturesAccepts unbalanced electret microphones with 3.5mm mono jack plugs.Part of C-Tecs patented Outreach Plate audio input extension system.Compatible with C-Tecs entire range of PDA102 200E Pro-Rangeand ML1 induction loop amplifiers.Can be connected to any third-party audio or induction loop amplifier using an APV 24V 250mA power supply.Mounts on a 25mm standard UK single gang back box. GBP 47.59 1
C-Tec QT636 Quantec Interface Unit with Remote Socket C-Tec QT636 Quantec Interface Unit with Remote SocketAllows any device with a normally open or normally closed 6.35mm 14 inch jack plug to be connected to Quantec. Particularly suited for use with our NC805MD Portable Movement Detector nooperation QT644 Floor Pressure mat nooperationQT633 Bed Exit mat ncoperationor QT634 Chair ExitMat nc operation. Must be wired as a slave to a QT602 or QT609 range addressable call point or QT630 dementia care controller.Key FeaturesWhen thedevice connected to the QT636 is operated a call will be generated on the Quantec call system as programmed.Mounts on a standard UK 25mm single gang back box. GBP 47.92 1
C-Tec QT602 Quantec Call Point with Button Reset C-Tec QT602 Quantec Call Point with Button ResetA programmable addressable call point cw remote jack socket for use with C-TECsQuantec Addressable Call System. Includes a Call button Resetbuttonand redgreen confidence light. Can make up to 5levels of call - Standard Ensuite Help Required Emergency Presence Attendance dependent on configuration and ancillary devices used. Attack and Attendance calls can also be made if connected to compatible slave infrared receiver.Key FeaturesRemote socket allows the connection of optional tail call leads pressure mats etc.Can be programmed to operate in a multitude of ways using a QT423 configurator.Connections provided for additional slave devices such as ceiling pulls overdoor lights slave infrared receivers and more.QT602M magnetic reset version also available. GBP 47.93 1
C-Tec QT602EM Quantec Euro Call Point with Magnetic Reset C-Tec QT602EM Quantec Euro Call Point with Magnetic ResetA programmable addressable call point cw iconised label and remote jack socket for use with C-TECsQuantec Addressable Call System. Includes a Call button Resetbuttonand redgreen confidence light. Can make up to 5levels of call - Standard Ensuite Help Required Emergency Presence Attendance dependent on configuration and ancillary devices used. Attack and Attendance calls can also be made if connected to compatible slave infrared receiver.Key FeaturesRemote socket allows the connection of optional tail call leads pressure mats etc.Can be programmed to operate in a multitude of ways using a QT423 configurator.Connections provided for additional slave devices such as ceiling pulls overdoor lights slave infrared receivers and more.Magnetic reset version. GBP 52.49 1
C-Tec QT602E Quantec Euro Call Point with Button Reset C-Tec QT602E Quantec Euro Call Point with Button ResetA programmable addressable call point cw iconised label and remote jack socket for use with C-TECsQuantec Addressable Call System. Includes a Call button Resetbuttonand redgreen confidence light. Can make up to 5levels of call - Standard Ensuite Help Required Emergency Presence Attendance dependent on configuration and ancillary devices used. Attack and Attendance calls can also be made if connected to compatible slave infrared receiver.Key FeaturesRemote socket allows the connection of optional tail call leads pressure mats etc.Can be programmed to operate in a multitude of ways using a QT423 configurator.Connections provided for additional slave devices such as ceiling pulls overdoor lights slave infrared receivers and more.QT602EM magnetic reset version also available. GBP 52.49 1
C-Tec QT602ERSM Quantec Euro Call Point with Sounder IR Receiver and Magnetic Reset C-Tec QT602ERSM Quantec Euro Call Point with Sounder IR Receiver and Magnetic ResetA programmable Quantec addressable call point cw iconised label infrared receiver call follower sounder and remote jack socket. Includes a Call buttonResetbuttons and redgreen confidence light. Onboard infrared receiver accepts calls from compatible Quantecinfrared transmitters. Can make up to 7 levels of call - Standard Ensuite Help Required Emergency Attack Presence Attendance dependent on configuration and ancillary devices used.Key FeaturesRemote socket allows the connection of optional tail call leads pressure mats etc.Can be programmed to operate in a multitude of ways using a QT423 configurator.Connections provided for additional slave devices such as ceiling pulls overdoor lights slave infrared receivers and more.Call follower sounder can be optionally used to inform staff that other calls are waiting when the system is in Night modesee Technical Specifications for further details.Magnetic reset version. GBP 66.88 1
C-Tec QT602RS Quantec Call Point with Sounder IR Receiver and Button Reset C-Tec QT602RS Quantec Call Point with Sounder IR Receiver and Button ResetA programmable Quantec addressable call point cw infrared receiver call follower sounder and remote jack socket. Includes a Call button Resetbuttonand redgreen confidence light. Onboard infrared receiver accepts calls from compatible Quantecinfrared transmitters. Can make up to 7 levels of call - Standard Ensuite Help Required Emergency Attack Presence Attendance dependent on configuration and ancillary devices used.Key FeaturesRemote socket allows the connection of optional tail call leads pressure mats etc.Can be programmed to operate in a multitude of ways using a QT423 configurator.Connections provided for additional slave devices such as ceiling pulls overdoor lights slave infrared receivers and more.Call follower sounder can be optionally used to inform staff that other calls are waiting when the system is in Night mode.QT602RSM magnetic reset version also available. GBP 61.07 1
C-Tec APL Line Level Audio Plate C-Tec APL Line Level Audio PlateThe Outreach Plate audio input extension system comprises a range of wall ceiling and desk mountable plates specifically designed to increase the audio input capability of any audio system. Covering the most common variants of audio connectors they work by mixing the signals from various audio input sources into a single balanced line level input on a compatible amplifier.Each input plate features a built-in mixer preamp input level control and balanced output. Typically up to 10Outreach plates any mix can be daisy-chained to one balanced line level connection with cable lengths up to 100m easily achievable using standard two-pair audio cable i.e. Belden 8723.Each plate requires four wires two balanced line LineA LineA one ground GND and one power connection V 12-32V d.c.. Most of C-TECs PDA Range induction loop amplifiers are fitted with an Outreach connection socket as standard. For audio systems that do not have an Outreach socket straightforward network connection can be achieved using an APV 24V 250mA d.c. regulated power supply and an APXO 3 pin XLR balanced line output plate.Key FeaturesAccepts stereo phono line-level input signals from sources such as TVs.Part of C-TECs patented Outreach Plate audio input extension system.Compatible with C-TECs entire range of PDA102 200E Pro-Rangeand ML1 induction loop amplifiers.Can be connected to any third-party audio or induction loop amplifier using an APV 24V 250mA power supply.Mounts on a 25mm standard UK single gang back box. GBP 47.62 1
C-Tec QT602ERS Quantec Euro Call Point with Sounder IR Receiver and Button Reset C-Tec QT602ERS Quantec Euro Call Point with Sounder IR Receiver and Button ResetA programmable Quantec addressable call point cw iconised label infrared receiver call follower sounder and remote jack socket. Includes a Call buttonResetbuttons and redgreen confidence light. Onboard infrared receiver accepts calls from compatible Quantecinfrared transmitters. Can make up to 7 levels of call - Standard Ensuite Help Required Emergency Attack Presence Attendance dependent on configuration and ancillary devices used.Key FeaturesRemote socket allows the connection of optional tail call leads pressure mats etc.Can be programmed to operate in a multitude of ways using a QT423 configurator.Connections provided for additional slave devices such as ceiling pulls overdoor lights slave infrared receivers and more.Call follower sounder can be optionally used to inform staff that other calls are waiting when the system is in Night modesee Technical Specifications for further details.QT602ERSM magnetic reset version also available. GBP 66.88 1
C-Tec NC802DERM Conventional Infrared Call Point with Magnetic Reset and Remote Socket C-Tec NC802DERM Conventional Infrared Call Point with Magnetic Reset and Remote SocketA button operated call point which comes with an infrared receiver capable of generating Standard and Emergency calls on an 800 Series Call System. Includes a magnetic reset target that requires an NC803M magnetic reset key to operate.Onboard infrared receiver will accept Standard Emergency calls from compatible 800 Series infrared transmitters. Calls can also be made by activating the call points CALL button to make a Standard call and the call points CALL RESET target together for an emergency call.Key FeaturesIncludes a6.35mm jack plug socket for the connection of an optional tail call lead or other ancillary calling deviceRed reassurance LED confirms a call has been madeOnboardmagentic reset target cancels Standard and Emergency calls made from the NC802DEWM and Standard calls made from other devices on the same zoneCan be connected to up to 3 NC302RXCS slave infrared ceiling receivers to increase coverageMounts on a standard UK 25mm single gang flush or surface back box GBP 63.59 1
C-Tec APM Omni-Directional Plated Microphone C-Tec APM Omni-Directional Plated MicrophoneThe Outreach Plate audio input extension system comprises a range of wall ceiling and desk mountable plates specifically designed to increase the audio input capability of any audio system. Covering the most common variants of audio connectors they work by mixing the signals from various audio input sources into a single balanced line level input on a compatible amplifier. Each input plate features a built-in mixer preamp input level control and balanced output.Typically up to 10Outreach plates any mix can be daisy-chained to one balanced line level connection with cable lengths up to 100m easily achievable using standard two-pair audio cable i.e. Belden 8723. Each plate requires four wires two balanced line LineA LineA one ground GND and one power connection V 12-32V d.c..Most of C-TECs PDA Range induction loop amplifiers are fitted with an Outreach connection socket as standard. For audio systems that do not have an Outreach socket straightforward network connection can be achieved using an APV 24V 250mA d.c. regulated power supply and an APXO 3 pin XLR balanced line output plate.Key FeaturesA self-contained omni-directional plated electret microphone complete with onboard mic to line level converter.Part of C-TECs patented Outreach Plate audio input extension system.Provides up to25m2 ambient coverage or 2.5m2 direct speechcoveragewhen located at a ceiling height of 2.5 to 3m.Compatible with C-TECs entire range of PDA102 200E Pro-Rangeand ML1 induction loop amplifiers.Can be connected to any third-party audio or induction loop amplifier using an APV 24V 250mA power supply.Mounts on a 25mm standard UK single gang back box. GBP 53.39 1