59 results (0,15679 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

C-Tec RXTI2 Hearing Loop Listener

C-Tec BF330CTSR 24V Loop Sounder - Shallow Base - Red

C-Tec BF333CTDR 24V Loop Sounder VID Deep Base - Red

C-Tec APL Line Level Audio Plate

C-Tec APL Line Level Audio Plate

C-Tec APL Line Level Audio PlateThe Outreach Plate audio input extension system comprises a range of wall ceiling and desk mountable plates specifically designed to increase the audio input capability of any audio system. Covering the most common variants of audio connectors they work by mixing the signals from various audio input sources into a single balanced line level input on a compatible amplifier.Each input plate features a built-in mixer preamp input level control and balanced output. Typically up to 10Outreach plates any mix can be daisy-chained to one balanced line level connection with cable lengths up to 100m easily achievable using standard two-pair audio cable i.e. Belden 8723.Each plate requires four wires two balanced line LineA LineA one ground GND and one power connection V 12-32V d.c.. Most of C-TECs PDA Range induction loop amplifiers are fitted with an Outreach connection socket as standard. For audio systems that do not have an Outreach socket straightforward network connection can be achieved using an APV 24V 250mA d.c. regulated power supply and an APXO 3 pin XLR balanced line output plate.Key FeaturesAccepts stereo phono line-level input signals from sources such as TVs.Part of C-TECs patented Outreach Plate audio input extension system.Compatible with C-TECs entire range of PDA102 200E Pro-Rangeand ML1 induction loop amplifiers.Can be connected to any third-party audio or induction loop amplifier using an APV 24V 250mA power supply.Mounts on a 25mm standard UK single gang back box.

GBP 47.62
1

C-Tec APXL XLR 3 Pin Line Level Plate

C-Tec APXL XLR 3 Pin Line Level Plate

C-Tec APXL XLR 3 Pin Line Level PlateThe Outreach Plate audio input extension system comprises a range of wall ceiling and desk mountable plates specifically designed to increase the audio input capability of any audio system. Covering the most common variants of audio connectors they work by mixing the signals from various audio input sources into a single balanced line level input on a compatible amplifier. Each input plate features a built-in mixer preamp input level control and balanced output.Typically up to 10Outreach plates any mix can be daisy-chained to one balanced line level connection with cable lengths up to 100m easily achievable using standard two-pair audio cable i.e. Belden 8723. Each plate requires four wires two balanced line LineA LineA one ground GND and one power connection V 12-32V d.c..Most of C-TECs PDA Range induction loop amplifiers are fitted with an Outreach connection socket as standard. For audio systems that do not have an Outreach socket straightforward network connection can be achieved using an APV 24V 250mA d.c. regulated power supply and an APXO 3 pin XLR balanced line output plate.Key FeaturesAccepts stereo phono line-level input signals from sources such as TVs.Part of C-TECs patented Outreach Plate audio input extension system.Compatible with C-TECs entire range of PDA102 200E Pro-Rangeand ML1 induction loop amplifiers.Can be connected to any third-party audio or induction loop amplifier using an APV 24V 250mA power supply.Mounts on a 25mm standard UK single gang back box.

GBP 47.64
1

C-Tec BF459ACXW CX O Class Base - VAD - White

C-Tec PL1SHELF Wall Mounting Storage Shelf for PL1 Amplifier

C-Tec BF457ACXWLD CX C Class Base Voice Sounder - White Lockdown

C-Tec BF455ACXW CX O Class Base Voice Sounder - VAD - White

C-Tec BF455ACXW CX O Class Base Voice Sounder - VAD - White

C-Tec BF455ACXW CX O Class Base Voice Sounder - VAD - WhiteThe Base Mount range of addressable loop-powered basesincludes voice sounders and combined voice sounder visual alarm devices VADs.Their purpose is to visually and audibly alert building occupants of a firealarm. They are designed for use with C-TECs ZFPXFP Apollo Discovery protocolpanels and other third-party Apollo Discovery protocol panels. Howevercompatibility testing with third-party panels is recommended to ensure correctoperation.The bases offer low current consumption high sound outputhigh efficiency VADs seven selectable volume levels 15 selectable tone pairsand built-in short-circuit loop isolators.The combined sounder and VAD on the BF455ACXW andBF457ACXW bases can be set to operate independently of each other paneldependent function.All bases are designed to comply with all relevant sectionsof the fire alarm device standards EN 54-3 Sounders EN 54-23 Visual alarmdevices - VADs and EN 54-17 Short-circuit isolators.Key FeaturesSuperb sound intelligibilityIncludes three selectable voice message pairsIncludes the same electronics as our EN54-3 17certified base soundersOnboard short-circuit loop isolator550A quiescent current10mA alarm current 24V DC voice sounder on maxGroup addressing facility allows multiple devices to beoperated simultaneously7 selectable volume levelsOptional BF330CTLIDW white or BF330CTLIDR red cap availablefor stand-alone useIP21C ratedDetector spare wires includedPlease note This image is for illustrative purposes only

GBP 64.69
1

C-Tec BF432ACXW CX O Class Base Sounder VAD

C-Tec CA732 CA Zone Monitor Module

C-Tec APQL Line Level Jack Plate 6.35mm

C-Tec APQL Line Level Jack Plate 6.35mm

C-Tec APQL Line Level Jack Plate 6.35mmThe Outreach Plate audio input extension system comprises a range of wall ceiling and desk mountable plates specifically designed to increase the audio input capability of any audio system. Covering the most common variants of audio connectors they work by mixing the signals from various audio input sources into a single balanced line level input on a compatible amplifier. Each input plate features a built-in mixer preamp input level control and balanced output.Typically up to 10Outreach plates any mix can be daisy-chained to one balanced line level connection with cable lengths up to 100m easily achievable using standard two-pair audio cable i.e. Belden 8723. Each plate requires four wires two balanced line LineA LineA one ground GND and one power connection V 12-32V d.c..Most of C-TECs PDA Range induction loop amplifiers are fitted with an Outreach connection socket as standard. For audio systems that do not have an Outreach socket straightforward network connection can be achieved using an APV 24V 250mA d.c. regulated power supply and an APXO 3 pin XLR balanced line output plate.Key FeaturesAccepts 6.35mm 14 jack feeds from audio equipment such as stage or church mixing desks etc.Part of C-TECs patented Outreach Plate audio input extension system.Compatible with C-TECs entire range of PDA102 200E Pro-Rangeand ML1 induction loop amplifiers.Can be connected to any third-party audio or induction loop amplifier using an APV 24V 250mA power supply.Mounts on a 25mm standard UK single gang back box.

GBP 49.57
1

C-Tec APJ Microphone Jack Outreach Plate 3.5mm

C-Tec APJ Microphone Jack Outreach Plate 3.5mm

C-Tec APJ Microphone Jack Outreach Plate 3.5mmThe Outreach Plate audio input extension system comprises a range of wall ceiling and desk mountable plates specifically designed to increase the audio input capability of any audio system. Covering the most common variants of audio connectors they work by mixing the signals from various audio input sources into a single balanced line level input on a compatible amplifier. Each input plate features a built-in mixer preamp input level control and balanced output.Typically up to 10Outreach plates any mix can be daisy-chained to one balanced line level connection with cable lengths up to 100m easily achievable using standard two-pair audio cable i.e. Belden 8723. Each plate requires four wires two balanced line LineA LineA one ground GND and one power connection V 12-32V d.c..Most of C-Tecs PDA Range induction loop amplifiers are fitted with an Outreach connection socket as standard. For audio systems that do not have an Outreach socket straightforward network connection can be achieved using an APV 24V 250mA d.c. regulated power supply and an APXO 3 pin XLR balanced line output plate.Key FeaturesAccepts unbalanced electret microphones with 3.5mm mono jack plugs.Part of C-Tecs patented Outreach Plate audio input extension system.Compatible with C-Tecs entire range of PDA102 200E Pro-Rangeand ML1 induction loop amplifiers.Can be connected to any third-party audio or induction loop amplifier using an APV 24V 250mA power supply.Mounts on a 25mm standard UK single gang back box.

GBP 47.59
1

C-Tec APQM Microphone Jack Plate 6.35mm

C-Tec APQM Microphone Jack Plate 6.35mm

C-Tec APQM Microphone Jack Plate 6.35mm The Outreach Plate audio input extension system comprises a range of wall ceiling and desk mountable plates specifically designed to increase the audio input capability of any audio system. Covering the most common variants of audio connectors they work by mixing the signals from various audio input sources into a single balanced line level input on a compatible amplifier.Each input plate features a built-in mixer preamp input level control and balanced output. Typically up to 10Outreach plates any mix can be daisy-chained to one balanced line level connection with cable lengths up to 100m easily achievable using standard two-pair audio cable i.e. Belden 8723.Each plate requires four wires two balanced line LineA LineA one ground GND and one power connection V 12-32V d.c.. Most of C-TECs PDA Range induction loop amplifiers are fitted with an Outreach connection socket as standard. For audio systems that do not have an Outreach socket straightforward network connection can be achieved using an APV 24V 250mA d.c. regulated power supply and an APXO 3 pin XLR balanced line output plate.Key FeaturesAccepts balanced or unbalanced electret microphones with 6.35mm 14 jack plugs.Part of C-TECs patented Outreach Plate audio input extension system.Compatible with C-TECs entire range of PDA102 200E Pro-Rangeand ML1 induction loop amplifiers.Can be connected to any third-party audio or induction loop amplifier using an APV 24V 250mA power supply.Mounts on a 25mm standard UK single gang back box.

GBP 49.57
1

C-Tec APXM XLR 3 Pin Microphone Plate

C-Tec APXM XLR 3 Pin Microphone Plate

C-Tec APXM XLR 3 Pin Microphone PlateThe Outreach Plate audio input extension system comprises a range of wall ceiling and desk mountable plates specifically designed to increase the audio input capability of any audio system. Covering the most common variants of audio connectors they work by mixing the signals from various audio input sources into a single balanced line level input on a compatible amplifier. Each input plate features a built-in mixer preamp input level control and balanced output.Typically up to 10Outreach plates any mix can be daisy-chained to one balanced line level connection with cable lengths up to 100m easily achievable using standard two-pair audio cable i.e. Belden 8723. Each plate requires four wires two balanced line LineA LineA one ground GND and one power connection V 12-32V d.c..Most of C-TECs PDA Range induction loop amplifiers are fitted with an Outreach connection socket as standard. For audio systems that do not have an Outreach socket straightforward network connection can be achieved using an APV 24V 250mA d.c. regulated power supply and an APXO 3 pin XLR balanced line output plate.Key FeaturesAccepts balanced or unbalanced microphones with standard 3 pin XLR connectors.Part of C-TECs patented Outreach Plate audio input extension system.Compatible with C-TECs entire range of PDA102 200E Pro-Rangeand ML1 induction loop amplifiers.Can be connected to any third-party audio or induction loop amplifier using an APV 24V 250mA power supply.Mounts on a 25mm standard UK single gang back box.

GBP 47.30
1

C-Tec CA730 CA Input Output Module

C-Tec APM Omni-Directional Plated Microphone

C-Tec APM Omni-Directional Plated Microphone

C-Tec APM Omni-Directional Plated MicrophoneThe Outreach Plate audio input extension system comprises a range of wall ceiling and desk mountable plates specifically designed to increase the audio input capability of any audio system. Covering the most common variants of audio connectors they work by mixing the signals from various audio input sources into a single balanced line level input on a compatible amplifier. Each input plate features a built-in mixer preamp input level control and balanced output.Typically up to 10Outreach plates any mix can be daisy-chained to one balanced line level connection with cable lengths up to 100m easily achievable using standard two-pair audio cable i.e. Belden 8723. Each plate requires four wires two balanced line LineA LineA one ground GND and one power connection V 12-32V d.c..Most of C-TECs PDA Range induction loop amplifiers are fitted with an Outreach connection socket as standard. For audio systems that do not have an Outreach socket straightforward network connection can be achieved using an APV 24V 250mA d.c. regulated power supply and an APXO 3 pin XLR balanced line output plate.Key FeaturesA self-contained omni-directional plated electret microphone complete with onboard mic to line level converter.Part of C-TECs patented Outreach Plate audio input extension system.Provides up to25m2 ambient coverage or 2.5m2 direct speechcoveragewhen located at a ceiling height of 2.5 to 3m.Compatible with C-TECs entire range of PDA102 200E Pro-Rangeand ML1 induction loop amplifiers.Can be connected to any third-party audio or induction loop amplifier using an APV 24V 250mA power supply.Mounts on a 25mm standard UK single gang back box.

GBP 53.39
1

C-Tec BF446ACXDRLD CX Wall Voice Sounder Deep Base Red Lockdown

C-Tec XFP508H Hush Button Hochiki ESP Protocol

C-Tec XFP508H Hush Button Hochiki ESP Protocol

C-Tec XFP508H Hush Button Hochiki ESP ProtocolThe XFP508H Hush Button has been specifically designed to reduce the incidence of false alarms in houses of multiple occupation by providing reliable fully monitored fire detection alarm and silencing facilities inside each individual flat or apartment.It can be looked upon as a miniature loop-powered single zone fire alarm controller that sits and is addressed on an Hochiki ESP analogue loop with the ability to communicate its status back to the host panel. On a typical system one Hush Button is fitted in each dwelling complete with conventional detectors and conventional sounders to provide occupants with a simple means of invoking two types of hushed period.By providing occupants with this level of control over their fire alarm systems it helps reduce false alarms and prevent unnecessary building evacuations system vandalism and the likelihood of a true alarm signal being ignored.Key FeaturesUpgrades the level of protection offered in a flat or apartment from the Grade D minimum mainsbattery smoke alarms to Grade A or BProvides each individual dwelling with a 2 minute silence facility and 15 minute isolate facility to BS 5839 pt 6 clause 12.2Can be operated by building occupants whilst standing at floor levelIncludes a built-in loop isolator conventional sounder circuit conventional detector circuit and three status LEDsFully monitored for open and short circuit faults logging facilities at the host panel give full traceability of any problemsFailsafe operation - a general fire condition at the host panel will override any silencedisolated state at the hush button and immediately turn on its local soundersOperation of a manual call point fitted with a resistor of less than 400 ohm will immediately trigger the host panel a 330 Ohm resistor is suppliedCommon OV line allows sounders and detectors to be wired in three core cable

GBP 74.52
1

C-Tec XFP508X Hush Button Apollo XP95 Discovery Protocol

C-Tec XFP508X Hush Button Apollo XP95 Discovery Protocol

C-Tec XFP508X Hush Button Apollo XP95 Discovery ProtocolThe XFP508X Hush Button has been specifically designed to reduce the incidence of false alarms in houses of multiple occupation by providing reliable fully monitored fire detection alarm and silencing facilities inside each individual flat or apartment.It can be looked upon as a miniature loop-powered single zone fire alarm controller that sits and is addressed on an XP95 Discovery or Xplorer analogue loop with the ability to communicate its status back to the host panel. Typically one Hush Button is fitted in each dwelling complete with conventional detectors and conventional sounders to provide occupants with a simple means of invoking two types of hushed period.By providing occupants with this level of control over their fire alarm systems it helps reduce false alarms and prevent unnecessary building evacuations system vandalism and the likelihood of a true alarm signal being ignored.Key FeaturesUpgrades the level of protection offered in a flat or apartment from the Grade D minimum mainsbattery smoke alarms to Grade A or BProvides each individual dwelling with a 2-minute silence facility and 15 minute isolate facility to BS 5839 pt 6 clause 12.2Can be operated by building occupants whilst standing at floor levelIncludes a built-in loop isolator conventional sounder circuit conventional detector circuit and three status LEDsFully monitored for open and short circuit faults logging facilities at the host panel give full traceability of any problemsFailsafe operation - a general fire condition at the host panel will override any silencedisolated state at the hush button and immediately turn on its local soundersOperation of a manual call point fitted with a resistor of less than 400 ohm will immediately trigger the host panel a 330 Ohm resistor is suppliedCommon OV line allows sounders and detectors to be wired in three core cable

GBP 74.52
1

C-Tec BF365SC Sounder Isolator Controller

C-Tec BF365SC Sounder Isolator Controller

BF365SC Sounder Isolator ControllerBF365SC Conventional Sounder Controller and its associated BF365IM Isolator Modules are designed to interface to a fire alarm panels conventional sounder circuit. The Modules each of which would typically have a conventional sounder connected to it are wired in a loop arrangement beginning and ending at the controller. The Controller transforms the conventional sounder circuits monitoring and triggering voltages into its own unique control voltages which it uses to trigger the Isolator Modules and monitor the sounder loop wiring.Each Module has smart sensing which means if a wiring fault should occur the Modules nearest to the faulty section of cabling will if needed isolate this section. As the Modules are driven from each direction any loss of cable integrity will have no effect on the functionality of the actual sounders. Having a fault tolerant arrangement such as this means that low cost cabling can be used for the sounder circuit subject to the fire officers approval leading to significant savings in installation.Key FeaturesDesigned to meet requirement 17.9.2c of Dutch standard NEN2575BSI certified to EN54 parts 17 18Easily interfaced to a conventional fire alarm sounder circuitAllows low-cost non-fire resistant sounder circuit cabling to be used when used in conjunction with our BF365IM Isolator Modules subject to fire officer approval.Wiring must be made in a loop arrangement beginning and ending at the controllerIf a wiring fault should occur the Modules nearest to the faulty section of cabling will if needed isolate this section. As the Modules are driven from each direction any loss of cable integrity will have no effect on the functionality of the actual soundersFits on standard UK 25mm flush or surface mount back boxesNot suitable for use in the UK

GBP 77.21
1