C-Tec CFP Relay Output Card Reset Fault Aux amp Remote Relay Outputs CFP762 C-Tec CFP Relay Output Card Reset Fault Aux Remote Relay Outputs CFP762An optional system expansion device for use withCFP Standard 2-8 Zone Fire PanelsorCFP AlarmSense 2-8 Zone Fire Panels.Key FeaturesProvides four panel-controlled volt free relay outputs reset fault aux. fire and remote.PCB mounts inside the CFP fire panel.Reset relay is active during the panels reset cycle.Fault relay is active in any fault condition. This relay is failsafe and normally energised - if power is removed from the panel the relay will changeover to produce a fault signal.Aux. fire relay is active in an alarm condition provided all relevant delays have expired.Remote relay is active during any Alarm Condition provided all relevant delays have expired.Outputs are NOT designed to switch mains voltages. GBP 46.63 1
C-Tec 24V 1.5A 5 Series Encased Power Supply PCB ONLY BF560-24E C-Tec 24V 1.5A 5 Series Encased Power Supply PCB ONLY BF560-24EThe BF560-24E can be optionally customised to suit your exact requirements using a BF423 configurator and PC. Configurable parameters includeFloat voltage temperature compensation Battery charge rate mA Battery impedance Configurable InputOutputsettings.Key FeaturesApowerful switch modedigital hybrid PSU that can be customised to suit your exact requirementsPlasticcoveron PSU PCB guards against touching live parts to VDE 0100-410Includes the same electronics as our BF560-24LPCBcertified EN54-4A2 boxed 24V 1.5A PSUMetal base platefacilitatesstraightforwardmountinginside third-party OEMenclosuresIncludes a single-pole volt-free changeover relay that switches for any fault conditionIncludes afault type hazardous voltages present LEDTwo selectable battery charge currentsBattery fault impedance limits can be optimised to suit load current helps extend battery lifeMains fail simulation modeImproved on-board temperature sensor with optional remote sensorElectronic functions comply with EN50131-6 grades 1-4 for security applicationsOptional PCB-only versionwithout a metal base plate available GBP 78.17 1
C-Tec CFP763 Relay Output Card as per CFP762 8 outputs per zone relays C-Tec CFP Relay Output Card as per CFP762 8 outputs per zone relays CFP763An optional system expansion device for use withCFP Standard 2-8 Zone Fire PanelsorCFP AlarmSense 2-8 Zone Fire Panels.Key FeaturesProvides four panel-controlled volt free relay outputs reset fault aux. fire and remote and eight output per zone relays.PCB mounts inside the CFP fire panel.Reset relay is active during the panels reset cycle.Fault relay is active in any fault condition. This relay is failsafe and normally energised - if power is removed from the panel the relay will changeover to produce a fault signal.Aux. fire relay is active in an alarm condition provided all relevant delays have expired.Remote relay is active during any Alarm Condition provided all relevant delays have expired.Output per zone relays will changeover when the corresponding zone is in alarm subject to certain conditions - for full details refer to the instructions downloadable below.Outputs are NOT designed to switch mains voltages. GBP 67.02 1
C-Tec CA730 CA Input Output Module C-Tec CA730 CA Input Output ModuleThe C-Tec CA730 is an addressable input output interfacemodule using the C-Tec CAST analogue addressable protocol.CAST is the worlds most-advanced distributedintelligence fire alarm system protocol. Conceived designed and realised byC-TEC as part of a five-year multi-million pound project it involved thecreation of a powerful proprietary communication protocol C-TEC AddressableSystem Technology CAST and multiple control panels field devices.Key FeaturesLPCB certified to EN54-17 18 and Kiwa Teleficationcertified to EN54-13Incorporates the functions of a switch monitor zone monitorand output unitUp to 20 conventional detectors 10 MCPsAny normally open switch with an EOL resistor fittedA simple normally open or closed switch non-faultmonitoredOnboard short-circuit loop isolator5.5mA typical alarm current 1.3mA typical quiescentcurrent 22-40V DCIndicators for Loop polling input faults and relay statusCan switch 1A30V DC or 0.3A125V ACIncludes volt free changeover contacts that can be used totrigger rollershutter doors gas shut-off valves smoke vents etcMountable on a C-TEC NCP-26 surface box or a standard UK25mm double gang back box not supplied GBP 51.37 1
C-Tec CA731 CA Mains Switching Input Output Module C-Tec CA731 CA Mains Switching Input Output Module The C-Tec CA731 is a mains switching input output interfacemodule using the C-Tec CAST analogue addressable protocol.CAST is the worlds most-advanced distributedintelligence fire alarm system protocol. Conceived designed and realised byC-TEC as part of a five-year multi-million pound project it involved thecreation of a powerful proprietary communication protocol C-TEC AddressableSystem Technology CAST and multiple control panels field devices.Key FeaturesLPCB certified to EN54-17 18 and Kiwa Teleficationcertified to EN54-13A mains-switching version of our CA730 input output moduleCapable of switching 5A 230 V AC or 5A 30V DCIncorporates the functions of a switch monitor zone monitorand output unitUp to 20 conventional detectors and 10 MCPsAny normally open switch with an EOL resistor fittedA simple normally open or closed switch non-faultmonitoredOnboard short-circuit loop isolator6mA typical alarm current 1.7mA typical quiescent current 22-40V DCIndicators for Loop polling input faults and relay statusIncludes volt free changeover contacts that can be used totrigger rollershutter doors gas shut-off valves smoke vents etcMountable on a C-TEC NCP-26 surface box or a standard UK25mm double gang back box not supplied GBP 60.32 1