C-Tec BF325 Alert Buddy Kit C-Tec BF325 Alert Buddy KitA portable deaf persons fire alarm alert system ideal foruse at home in hotel bedrooms and other residential settings.Works by monitoring and listening to the ambient sound in aroom and automatically detecting the presence of a fire alarm signal.When a fire signal is detected Alert Buddy will flash emita 1KHz low frequency tone 75dBa 1m and activate a vibrating pillow padavailable separately.The combination of light sound vibration helps maximisethe chances of someone being alerted to a fire alarm even if they are sleeping.Key FeaturesCan be wall mounted or will sit on top of a tableIncludes a combined Silence Test buttonVisual Alarm Indicator designed to the O Class requirementsof EN54-23Plugtop chargeradaptor supplied GBP 195.94 1
C-Tec CA737 EACIE 4 Way Flat Interface No PSU In Cabinet Extendable To 8 Way C-Tec CA737 EACIE 4 Way Flat Interface No PSU In Cabinet Extendable To 8 WayThe C-Tec CA737 is a loop powered 4-8 way flat interface for use on the C-TEC EVAC-ALERT system. It is supplied as a 4-circuit unit extendable to 8 using CA737PCBDetailsA loop-powered 4-8 way flat interface for use on a C-TEC EVAC-ALERT systemSupplied as a 4 circuit unit extendable to 8 using a CA737PCB.Provides 4 or 8 monitored 12.5mA sounder circuits to power up to 2 self-testing evacuation alert sounders per flatIncludes space and connections for an optional fully monitored auxiliary 24V 1A CA737PSU to power additional visual indicators andor vibrating pillow padsIncludes an onboard short circuit loop isolatorUses one loop address per 4 sounder circuitsSounder circuit test facility per circuitThe most practical and flexible device interfacing method for most new and refurb installations the unit is ideally mounted in a riser on each floorMaintains the independent open short circuit monitoring of all sounder circuits GBP 340.12 1
C-Tec CFP708-4 8 Zone Conventional Fire Panel LPCB Approved C-Tec CFP 8 Zone Conventional Fire Panel LPCB Approved - CFP708-4LPCB certified to EN54-24 C-TECs CFP 8 zone conventional fire alarm panel offers an array of user and installer-friendly features at a very competitive price. Supplied in an attractive flush or surface mountable plastic enclosure it includes two detector zones four conventional sounder circuits class change and alert inputs on-board fire and fault relays and combined keypadkey switch entry.A wide range of engineering functions are also provided including selectable zone delays coincidence and non-latching zone facilities. Comprehensive test and fault finding facilities are also provided. Optional repeaters relay expansion boards and EN54-13 system compliance devices are also available.Key FeaturesThird-party certified to EN54 parts 2 and 4 by the Loss Prevention Certification Board LPCB with optional EN54 part 13 compliance from the BSI.Intuitive user-friendly interface with colour-coded buttons and combined keypadkeyswitch entry.Manufactured by C-TEC in the UK.Two detector zone circuits.Four conventional sounder circuitsIntegral 1.5A EN54-4A2 compliant switch mode PSU.Wide range of engineering functions including zone test coincidence zone delay and non-latching zones.Two on-board relays Fire and Fault.Two open-collector outputs Remote and Reset.Class change and alert inputs.Installer-friendly design.Attractive flush or surface mountable plastic lid and enclosure - no bezel required.Low 25mA quiescent current.Multiple indicators.System expansion connections provided for up to eight two-wire repeaters one CFP761 network card required per system optional CFP relay boards and optional EN54-13 compliant sounder circuit boards.Space for two x 12V 3.3Ah VRLA batteries.Fully compatible with C-TECs ActiV range of conventional fire detectors. GBP 208.82 1
C-Tec CFP Two Wire 2 Zone AlarmSense Control Panel - CFP702-2 C-Tec CFP Two Wire 2 Zone AlarmSense Control Panel - CFP702-2C-TECs LPCB certified two-wire CFP AlarmSense fire panel is designed to work with Apollos AlarmSense range of detectors call points sounders and beacons. Most conventional fire systems are designed to work with two pairs of wires per zone one pair for detection devices such as smoke detectors heat detectors and manual call points the other for alarm devices such as bells sounders or strobes. By using different voltage bands for quiescent and alarm states AlarmSense components can be connected to the same pair of supply wires.When powered and controlled by the CFP two-wire fire panel this reliable technology takes all the complexity out of fire alarm system design leading to quicker less expensive and more flexible installation. Indeed research shows an AlarmSense two-wire system can achieve a 20-25 reduction of labour over a standard four wire conventional system. AlarmSense devices are acceptable for BS 5839-1 and BS 5839-6 systems making them particularly useful for fire protection in Houses of Multiple Occupation HMOs.Key FeaturesLPCB certified to EN54 parts 2 and 4Intuitive user-friendly interface with colour-coded buttons and combined keypadkeyswitch entry to access level 22 4 or 8 AlarmSense zone circuits dependent on model purchasedFour conventional sounder circuitsIntegral 1.5A EN54-4A2 compliant switch mode PSUWide range of engineering functions including zone test coincidence zone delay and non- latching zonesTwo on-board relays Fire and FaultTwo open-collector outputs Remote and ResetClass change and alert inputsInstaller-friendly design accommodates easy first fix and straightforward maintenanceAttractive flush or surface mountable plastic lid and enclosure - no bezel requiredLow quiescent currentMultiple indicatorsEnd of line units included one per zoneAncillary system expansion connections provided for up to eight two-wire repeaters one CFP761 network driver card required per system and optional CFP relay boardsSpace for two x 12V 3.3Ah VRLA batteries GBP 182.66 1
C-Tec CFP704-2 CFP Two Wire 4 Zone AlarmSense Control Panel C-Tec CFP Two Wire 4 Zone AlarmSense Control Panel - CFP704-2C-TECs LPCB certified two-wire CFP AlarmSense fire panel is designed to work with Apollos AlarmSense range of detectors call points sounders and beacons. Most conventional fire systems are designed to work with two pairs of wires per zone one pair for detection devices such as smoke detectors heat detectors and manual call points the other for alarm devices such as bells sounders or strobes. By using different voltage bands for quiescent and alarm states AlarmSense components can be connected to the same pair of supply wires.When powered and controlled by the CFP two-wire fire panel this reliable technology takes all the complexity out of fire alarm system design leading to quicker less expensive and more flexible installation. Indeed research shows an AlarmSense two-wire system can achieve a 20-25 reduction of labour over a standard four wire conventional system. AlarmSense devices are acceptable for BS 5839-1 and BS 5839-6 systems making them particularly useful for fire protection in Houses of Multiple Occupation HMOs.Key FeaturesLPCB certified to EN54 parts 2 and 4Intuitive user-friendly interface with colour-coded buttons and combined keypadkeyswitch entry to access level 22 4 or 8 AlarmSense zone circuits dependent on model purchasedFour conventional sounder circuitsIntegral 1.5A EN54-4A2 compliant switch mode PSUWide range of engineering functions including zone test coincidence zone delay and non- latching zonesTwo on-board relays Fire and FaultTwo open-collector outputs Remote and ResetClass change and alert inputsInstaller-friendly design accommodates easy first fix and straightforward maintenanceAttractive flush or surface mountable plastic lid and enclosure - no bezel requiredLow quiescent currentMultiple indicatorsEnd of line units included one per zoneAncillary system expansion connections provided for up to eight two-wire repeaters one CFP761 network driver card required per system and optional CFP relay boardsSpace for two x 12V 3.3Ah VRLA batteries GBP 226.68 1
C-Tec CFP708-2 CFP Two Wire 8 Zone AlarmSense Control Panel C-Tec CFP Two Wire 8 Zone AlarmSense Control Panel - CFP708-2C-TECs LPCB certified two-wire CFP AlarmSense fire panel is designed to work with Apollos AlarmSense range of detectors call points sounders and beacons. Most conventional fire systems are designed to work with two pairs of wires per zone one pair for detection devices such as smoke detectors heat detectors and manual call points the other for alarm devices such as bells sounders or strobes. By using different voltage bands for quiescent and alarm states AlarmSense components can be connected to the same pair of supply wires.When powered and controlled by the CFP two-wire fire panel this reliable technology takes all the complexity out of fire alarm system design leading to quicker less expensive and more flexible installation. Indeed research shows an AlarmSense two-wire system can achieve a 20-25 reduction of labour over a standard four wire conventional system. AlarmSense devices are acceptable for BS 5839-1 and BS 5839-6 systems making them particularly useful for fire protection in Houses of Multiple Occupation HMOs.Key FeaturesLPCB certified to EN54 parts 2 and 4Intuitive user-friendly interface with colour-coded buttons and combined keypadkeyswitch entry to access level 22 4 or 8 AlarmSense zone circuits dependent on model purchasedFour conventional sounder circuitsIntegral 1.5A EN54-4A2 compliant switch mode PSUWide range of engineering functions including zone test coincidence zone delay and non- latching zonesTwo on-board relays Fire and FaultTwo open-collector outputs Remote and ResetClass change and alert inputsInstaller-friendly design accommodates easy first fix and straightforward maintenanceAttractive flush or surface mountable plastic lid and enclosure - no bezel requiredLow quiescent currentMultiple indicatorsEnd of line units included one per zoneAncillary system expansion connections provided for up to eight two-wire repeaters one CFP761 network driver card required per system and optional CFP relay boardsSpace for two x 12V 3.3Ah VRLA batteries GBP 272.59 1